Search PubMed⌕ Search

Biomedical subjects

A Loria

Publications and source records attributed to A Loria.

At least 37 records · Page 2Linked to original sources

Red blood cell indices in a high altitude hospital population.

It is currently accepted that the red blood cell indices (MCV, MCH and MCHC) are the same in general care hospital populations throughout the world. The aim of the study was to explore whether the internationally accepted values for red cell indices are the same in a hospital located in Mexico City at 2240 meters above sea level (7352 feet). The setting for the study was a third level specialized care hospital for adults with chronic degenerative problems (trauma and obstetric cases were not seen). Each day, for a period of 139 working days, 120 EDTA blood samples of patients were assayed within 3h of extraction in a flow cytometer analyzer (Coulter STKR). Using the moving average approach of Bull (Reference 3) in batches of 20 samples, a raw daily value for each indice was obtained with the mean of the six daily moving averages. The daily raw value was multiplied by a ratio (assigned/observed ratio) of the corresponding daily value obtained in a normal preserved blood control (Coulter's 4C): we refer to them as corrected values in this paper. A total of seven batches of the Coulter control were used to obtain the corrected values during the 139 days of observation. The results were as follows. The mean (SD) of correction values in the 139 days were: MCV = 90.33 (.810) fl, MCH = 30.75 (.582) pg, MCHC = 33.38 (.630) g/dl. The indices showed significant changes in mean as a function of batch of the Coulter control used (F tests, p < 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effect of liver transplantation on sex-hormone disorders in male patients with alcohol-induced or post-viral hepatitis advanced liver disease.

The effects of liver transplantation on the pituitary-gonadal axis and sex-hormone metabolism were evaluated by studying hormonal status (androgens, oestrogens, and gonadotropins) and sex-hormone-binding globulin levels in men with advanced liver disease of both alcoholic and viral origins. Comparison of the results prior to and 6 months after liver transplantation showed that successful liver transplantation in men induced significant differences in sex-hormone levels and in pituitary-gonadal function in both alcoholic and post-hepatitis patients. Plasma testosterone and dihydrotestosterone levels increased, oestrogen (oestrone and oestradiol) and androstenedione levels fell while gonadotropin (FSH and LH) levels increased. There was also a fall in plasma prolactin levels. Sex-hormone binding globulin plasma levels were elevated prior to transplantation and decreased thereafter. These data show that male patients with advanced liver disease have biological hypogonadism and feminization, irrespective of the aetiology, and that these abnormalities rapidly improve after successful liver transplantation. Therefore in men with advanced liver disease the biochemical signs of sex hormone disturbance are reversible and may be largely related to the liver disease.

Adult↗

Factors predictive of the response to interferon in patients with chronic hepatitis C.

Factors predictive of the response to interferon in patients with chronic hepatitis C remain to be identified. In this study, we investigated factors predictive of the short-term response, defined as a return to normal alanine aminotransferase activity after treatment, and the long-term response defined as normal alanine aminotransferase activity 1 year after completing treatment, in 75 patients with chronic hepatitis C virus treated with recombinant alpha interferon (either 6 MU x 3/week for 3 months then 3 MU x 3/week for 3 months (n = 27) or 3 MU x 3/week for 6 months (n = 48)). At the end of treatment, 42 patients (56%) had normal alanine aminotransferase activity ("responders") and 33 (44%) had high alanine aminotransferase activity ("non-responders"). Twenty (48%) of the 42 responders had normal alanine aminotransferase activity 1 year after treatment ("sustained responders"), while 22 (52%) had high alanine aminotransferase activity ("transient responders"). The dosage of interferon was not predictive of the short-term and the long-term response to treatment. The responders differed significantly from the non-responders in terms of age, i.v. drug abuse, aspartate aminotransferase, gammaglutamyltranspeptidase and alkaline phosphatase activities, bilirubinemia, serum bile acid concentrations, prothrombin time, platelet count, ferritinemia, hyaluronic acid levels, positivity for the antibody to 5.1.1 of the recombinant immunoblot assay band and the histological fibrosis score. The following parameters were independently correlated with the short-term response in a multivariate analysis: gammaglutamyltranspeptidase activity, serum bile acid concentrations and positivity for the antibody to 5.1.1 of the recombinant immunoblot assay band.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Hepatitis C].

Hepatitis C virus (HCV), identified in 1989, is the main agent of Non-A, Non-B hepatitis. The number of HCV carriers in France is estimated between 500,000 and 2 millions. The main risk factors for HCV infection are blood products transfusion and i.v. drug abuse. Cirrhosis occurs in 30% of cases with a delay ranging from 10 to 30 years, and hepatocellular carcinoma in 2.5% of cases. Interferon is, for instance, the only effective therapy in patients with chronic hepatitis C; however, prolonged response (in terms of transaminase normalization) after stopping treatment occurs only in 20% of patients.

Acute Disease↗

The use of centrally prepared reagents in an external quality experimental trial.

The authors provide the results of a short-term experimental trial in external quality assessment in 42 clinical laboratories conducted by the Mexican Ministry of Health. Assay kits for glucose, urea, and creatinine were prepared by the Ministry. The results may prove useful to organizers of external quality assessments in third-world countries who may opt for this strategy to improve performance. The laboratories performed the tests on reconstituted lyophilized control serum, also prepared by the Ministry. All three assays were performed manually using colorimetric methods. On the basis of their intralaboratory precision (coefficients of variation less than 8%, 8-12%, and greater than 12% for high, medium, and low precision, respectively), 12 laboratories demonstrated high precision for all three tests. Eight laboratories showed medium and low precision for different tests, while the other 22 fell in between. The results showed that the strategy of using centrally prepared reagents to improve interlaboratory agreement did not work well for urea and creatinine, but met expectations for glucose. The laboratories achieved an interlaboratory coefficient of variation of 10% for glucose in this first trial.

Blood Glucose↗

Serum ferritin and mean corpuscular volume measurement in the diagnosis of beta-thalassaemia minor and iron deficiency.

The value of serum ferritin and mean corpuscular volume (MCV) measurement in distinguishing between iron deficient, beta-thalassaemia trait and normal subjects has been studied. Normal subjects had normal ferritin and MCV, iron-deficient ones had low ferritin and low or normal MCV, and thalassaemics had normal ferritin and low MCV. By the combined use of these two measurements it was possible to identify individuals belonging to one of the three categories with an accuracy of over 95%. Although definitive diagnosis of beta-thalassaemia trait requires the demonstration of abnormal haemoglobin A2 levels or reduced beta-chain synthesis, serum ferritin and MCV measurements are useful screening procedures for the initial diagnosis of beta-thalassaemia trait and iron deficiency. Because of the very small amounts of blood required for both of these measurements, they are particularly suitable for surveying large numbers of subjects in populations with a high prevalence of hypochromic-microcytic anaemias.

Adult↗

Serum ferritin in beta-thalassemia trait.

The diagnostic value of serum ferritin measurements in discriminating iron-deficiency anemia from thalassemia trait has been studied. In contrast to serum iron, percent transferrin saturation and total iron-binding capacity, where a high degree of overlap existed between the two groups, a clear-cut difference in serum ferritin levels was found between iron deficiency and thalassemia trait. The best separation of iron deficiency, thalassemia and normal controls was given by the combination of mean corpuscular volume and serum ferritin. Although definitive diagnosis of beta-thalassemia trait requires the demonstration of abnormal Hb A2 levels or beta-chain synthesis, serum ferritin is a useful screening test for the initial diagnosis of thalassemia trait. Because of the very small amounts of serum required for the measurement of ferritin, it is particularly suitable for surveying populations with a high prevalence of hypochromic-microcytic anemias.

Anemia, Hypochromic↗

External quality control program of four blood cell counters.

OBJECTIVE: To evaluate an internal-external quality control program of four automated counters. METHODS: Every one or two weeks during 14 months, six direct cell parameters were measured in three fresh blood samples in four Coulter counters. The median per parameter of the working day was used to detect inaccuracies and if the participants' internal control program confirmed it, a recalibration of the parameter was performed. RESULTS: In 21 of 22 instances, the internal program confirmed an inaccuracy and a recalibration was done (4 leukocyte and 5 erythrocyte counts, 5 hemoglobins, 7 red-cell volumes). In these four parameters there were no large differences between the lowest and highest counter upon analyzing all results whereas all counters differed from one another in the parameters that cannot be recalibrated by the user (platelet volume, red-cell distribution width). CONCLUSIONS: 1. The program contributed to good accuracy and precision within-counters and good concordancy between-counters in the parameters that can be recalibrated. 2. The counter differences in red-cell distribution width were sufficiently large (up to 9%) to affect clinical interpretation. This poses the need of width distribution reference ranges for each counter.

Blood Cell Count↗

Increasing frequency of gastric lymphoma in two national institutes of health in Mexico.

BACKGROUND: Some studies performed in developed countries with caucasian population have suggested an increase in the frequency of primary gastric lymphoma (PGL) in the past two decades. OBJECTIVE: To establish the frequency of PGL in two National Institutes of Health in Mexico in an interval of 18 years. METHODS: We reviewed 1,854 gastric malignant neoplasms diagnosed between 1979-1996 in mestizo patients seen at two different institutions. One of them (INC) is an oncological hospital, whereas the other one (INN) is a general hospital which treats patients with benign as well as malignant gastrointestinal diseases. RESULTS: A hundred and sixty three (8.8%) gastric lymphomas were identified from 1,854 gastric malignant tumors. The incidence of PGL showed a two to three-fold increase in the last years of the study in both institutions. The increased frequency was highly significant when compared to the initial rate. This increase does not appear to be due to patient selection criteria nor to the number of malignant gastric tumors in our institutions. CONCLUSIONS: Our results indicate an increased frequency of PGL the patient population of two National Institutes of Health in Mexico during the last years. Additional studies are necessary in order to define in the increase in PGL is limited to certain geographical areas or ethnic groups.

Humans↗