Search PubMed⌕ Search

Biomedical subjects

A Langenbucher

Publications and source records attributed to A Langenbucher.

At least 73 records · Page 4Linked to original sources

Nonmechanical excimer laser penetrating keratoplasty for perforated or predescemetal corneal ulcers.

OBJECTIVE: To review the authors' results using nonmechanical excimer laser trephination in penetrating keratoplasty for perforated or predescemetal corneal ulcers. DESIGN: Noncomparative, consecutive, interventional case series. PARTICIPANTS: Thirty-two patients with perforated (17) or deep (15) corneal ulcers (9 bacterial, 5 acanthamoebal, 10 herpetic, 3 associated with rheumatoid arthritis, 5 other) necessitating immediate tectonic keratoplasty. INTERVENTION: Penetrating tectonic keratoplasty with excimer laser trephination was performed along metal aperture masks in donor and recipient corneas. MAIN OUTCOME MEASURES: Clinical results including intraoperative and postoperative complications were evaluated. RESULTS: Trephination was possible in all eyes without perforation of predescemetal ulcers or extrusion of intraocular contents. No eyes with bacterial or acanthamoebal ulcers showed persistence or recurrence of infection. One eye showed recurrent epithelial herpetic keratitis. Best-corrected postoperative visual acuity ranged from 20/700 to 20/20 (median, 20/58), with 30 of 32 eyes achieving improvement of best visual acuity during follow-up (mean, 22.4 months) and with 12 of 32 eyes reaching a visual acuity of 20/40 or greater. Eyes with bacterial or acanthamoebal ulcers showed best results. Episodes of graft rejection occurred in nine eyes and resulted in irreversible opacity of the graft in seven cases. None of the eyes lost all vision, developed endophthalmitis, or had to be enucleated. CONCLUSIONS: Nonmechanical trephination is a useful technical refinement of tectonic penetrating keratoplasty à chaud for perforated or deep progressive corneal ulcers. This technique greatly facilitates exact trephination under these difficult surgical conditions and might possibly improve the prognosis of this procedure.

Adult↗

[Calculating the localization and dimension of the real pupil in keratoconus with ray tracing of corneal topography data].

BACKGROUND: It is crucial to center surgical procedures for optical indications on the pupil or the optical axis of the eye. In keratoconus the pupil appears to be dislocated due to optical aberrations of corneal topography. The purpose of this study was to evaluate the real pupil structure from the virtual image using exact raytracing techniques. PATIENTS AND METHODS: Eighty-eight patients with keratoconus (46 with mild and 42 with severe clinical signs) and a control group of 40 normal subjects were included in this study. Topographic height data were calculated from refraction data of a commercially available topographer (TMS-1) using a local approximation algorithm and a convex surface was modelled using a subdivision scheme. For the posterior corneal surface we postulated an aspherical surface with a central radius of curvature of 6.5 mm using Navarro's model eye. At the virtual pupil outline a bundle of parallel rays were intersected with the anterior and posterior corneal surface and refracted into the anterior chamber. The intersections of these rays with the pupil plane was defined as the real pupil outline. We assessed the amount and direction of pupil dislocation, the ratio between the virtual and real pupil size for each group and correlated these parameters with the central corneal power. RESULTS: The size of the virtual pupil exceeded the reference value of the real pupil in the normal group by 11%, in the group with mild keratoconus by 19% and in the group with severe keratoconus by 35%. The center of the virtual pupil was decentered 0.06 mm in the normal group, 0.49 in the group with mild keratoconus and 1.24 mm in the group with severe keratoconus. Whereas the direction of decentration was randomly in the normal group, we measured a preferred decentration to the inferior quadrants in mild keratoconus and a systematic decentration to the temporal inferior quadrant in severe keratoconus. Correlation of the optical dislocation did not correlate with central corneal power in any group. CONCLUSIONS: In keratoconic eyes the pupil outline is distorted and dislocated due to optical aberrations of the cornea. Exact raytracing technique allows the calculation of the real pupil outline from the virtual image and the topographic height of both corneal surfaces. Knowledge about the real pupil position may have an impact on adequate centration of keratorefractive surgery and penetrating keratoplasty.

Adult↗

[Transplant endothelium and measuring corneal thickness after non-high-risk keratoplasty with briefly or long-term preserved corneal donor tissue].

PURPOSE: The corneal endothelial cell density is essential for the pump function and the transparency of grafts after penetrating keratoplasty (PK). The purpose of this study was to assess corneal endothelial cell density after non-high-risk PK and to check for possible correlations with storage parameters of the donor corneas using two different storage methods. PATIENTS AND METHODS: Endothelial cell density (specular microscope EM 1100, TOMEY, Erlangen) and central corneal thickness (ultrasonic pachymetry SP-2000, TOMEY, Erlangen) were assessed 6 weeks, 3, 6, 9 months and one year postoperatively in 168 non-high-risk PKs. Short-term-preserved donor corneas were used in 89 patients, whereas in 79 patients organ-cultured corneas were used. The donor trephination was performed from the epithelial side using an artificial anterior chamber. The postoperative treatment with topical steroids was standardized. The mean donor post-mortem time was 9.6 +/- 8.0 hours for short-term-preserved and 17.6 +/- 10.5 hours for organ-cultured corneas (p < 0.0001). The storage time was 71 +/- 49 and 380 +/- 167 hours (p < 0.0001), respectively. RESULTS: Endothelial cell density did not differ significantly between the two storage methods (p > 0.05). At 6 weeks postoperatively, the mean endothelial cell density was 2042 +/- 675 cells/mm2 for short-term-preserved corneas and 1972 +/- 522 cells/mm2 for organ-cultured corneas (p = 0.7). Endothelial cell density did not decrease significantly (p > 0.05) within the observation period of 12 months in both groups (after 12 months: 1868 +/- 957 cells/mm2 and 1638 +/- 643 cells/mm2, respectively). The mean corneal thickness was 542 +/- 50 microns for short-term-preserved and 541 +/- 55 microns for organ-cultured corneas and remainded unchanged during the follow-up of 12 months (542 +/- 42 microns and 521 +/- 43 microns, respectively). Neither the group of short-term-preserved corneas nor organ-cultured corneas showed a significant correlation between endothelial cell density or central cornea thickness with post-mortem time or with storage time of the donor corneas at any postoperative stage (p > 0.1). CONCLUSION: During the first year after PK, only a small decrease in endothelial cell density was observed in comparison with the 6-weeks finding. The storage method does not seem to affect the short-term changes of endothelial cell density. Further long-term studies are necessary to assess the clinical relevance of these observations.

Adult↗

[Development of visual acuity in the early phase after photorefractive keratectomy in myopia].

BACKGROUND: Photorefractive keratectomy (PRK) using the excimer laser is an accepted surgical technique for correction of myopic refraction errors in case of spectacle or contact lens incompatibility. The purpose of this study was to assess the development of uncorrected (UVA) and best-corrected visual acuity (CVA) in the early course following PRK. PATIENTS AND METHODS: 48 eyes of 29 patients that underwent myopic photorefractive keratectomy using 193 nm excimer laser (MEL 60, Aesculap-Meditec) were included in this study. The mean preoperative spherical equivalent was -5.3 +/- 2.4 diopters (D) (range -1.75 to -9.5 D). Pre-, intra- and postoperative treatment was standardized. The median time interval to complete epithelial closure was 2 days. According to their spherical equivalent, patients were divided in two groups: group 1 with myopia < or = 6 D (n = 28), group 2 with myopia more than 6 D (n = 20). Examination of UVA and CVA were performed preoperatively and on days 3, 7 as well as 1 month, 3 and 6 months postoperatively. RESULTS: On day 3 after surgery UVA was 0.43 +/- 0.21 for group 1 with myopia < or = 6 D, and 0.36 +/- 0.14 for group 2 with myopia more than 6 D. The UVA was stable after 3 months (0.92 +/- 0.29 and 0.66 +/- 0.20, respectively), the CVA was stable after 1 month (1.04 +/- 0.18 and 0.86 +/- 0.19, respectively). After surgery, the UVA increased by +0.73 +/- 0.25, whereas the CVA increased by +0.05 +/- 0.10 for the whole group. The difference comparing pre- and postoperative UVA was significantly higher in group 1 (0.81 +/- 0.22) than in group 2 (0.60 +/- 0.26) (p = 0.002). However, postoperative CVA values were not significantly different from preoperative values in both groups after 6 months (p = 0.3). CONCLUSION: Useful uncorrected visual acuity is normally achieved at day 3 after PRK in eyes with mild to moderate myopia. With higher degrees of myopia the uncorrected visual acuity does increase slower towards a lower level. One of the reasons for this phenomenon might be a significant regression of the refractive effects during the first half year after surgery.

Adult↗

[Keratoconus screening with wave-front parameters based on topography height data].

BACKGROUND: The image-forming properties of a keratoconus eye are degraded even in the early stage of this disease. The purpose of this study was to develop keratoconus detection scheme based on topography height data independent of the currently used system which avoids the disadvantages of detection algorithms currently used in clinical practice. PATIENTS AND METHODS: Eighty-eight patients with keratoconus (46 with mild and 42 with severe clinical signs) and a control group of 40 normal subjects were included in this study. A decomposition of corneal topography height data into orthogonal Zernike polynomials was performed using the commercially available corneal topographer TMS-1. Expansion coefficients of the different groups were compared to evaluate significant differences. Elevated terms were used to detect the disease. The statistical significance of this detection scheme was compared to those given by the keratoconus detection software of the TMS-1. From the elevated Zernike terms a neural network was constructed and optimized for dividing keratoconus patients and normal controls. RESULTS: Some low-order Zernike coefficients with a radial order n < 8 were found to be elevated in patients with keratoconus and were used to define a new detection algorithm. This index performed at least as well (sensitivity in mild/severe keratoconus 93.4%/100% with a specificity of 100%) as keratoconus detection schemes based on the Klyce-Maeda and the Rabinowitz-Klyce indices as well as the I-S value and the Surface Asymmetry Index SAI in our study population. CONCLUSIONS: Zernike decomposition of corneal topography height data allows a definition of an exact and robust algorithm for detection of keratoconus. It avoids the drawbacks of refractive power based definitions and is independent on the individual topographer design.

Adolescent↗

[Topography-based calculation of keratoconus dimensions].

BACKGROUND: Keratoconus is a corneal dystrophy which usually develops in the second or third decade of life and shows various speed of progression. This disease may degrade the image-forming properties of the eye even in its early stage. The purpose of this study was to support the conventional clinical qualitative diagnostic methods of keratoconus handling with a topography-based algorithm to quantify the "ballooning" of the anterior corneal surface. PATIENTS AND METHODS: Eighty-eight patients with keratoconus (46 with mild and 42 with severe clinical signs) and a control group of 40 normal subjects were included in this study. Topographic height data were calculated from refraction data of a commercially available topographer (TMS-1) using a local approximation algorithm. A decomposition of corneal topography height data into orthogonal Zernike polynomials was performed to define a asphero-cylindrical model surface. From the difference of the raw height data and the model surface, the base, height and volume as well as the localization of the protrusion was quantified. RESULTS: The height of the corneal protrusion (23 to 71 microns), the volume of the cone (0.066 to 0.141 mm3) and the horizontal dimension (0.67 to 1.32 mm) increased highly significantly. In contrast, comparing the early to the severe stage of the disease the vertical dimension of the cone (0.64 to 0.93) changed much less. In the severe stage, the center of the protrusion was much more decentred (1.33 mm) than in the early stage (0.44) due to a shift in the inferior direction. CONCLUSIONS: The quantification of cone dimensions using corneal topography height data has the potential to assist qualitative clinical graduation in keratoconus independent of the system currently used. The knowledge about the exact amount of corneal protrusion and position of the cone may improve the assessment of the progression of the disease, thus being helpful for indication of a penetrating keratoplasty.

Adult↗

"Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser.

BACKGROUND/AIMS: "Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. METHODS: The procedure was performed in 20 enucleated pigs' eyes using open metal masks with eight "orientation teeth/notches" (0.3 x 0.15 mm, base x height), an automated globe rotation device, and either a 193 nm ArF excimer laser or a Q switched 2.94 microm Er:YAG laser. "Teeth/notches" were analysed by planimetry and scanning electron microscopy (SEM). RESULTS: Mean size was 0.30 (0.027) x 0. 16 (0.017) mm for "teeth" and 0.30 (0.035) x 0.15 (0.021) mm for "notches" (excimer), and 0.31 (0.022) x 0.16 (0.015) mm and 0.30 (0.031) x 0.14 (0.021) mm respectively (Er:YAG). Overall, variability of notches was higher than that of teeth. By SEM, comparable cut regularity and sustained ablation profile were observed with both lasers. However, the corneal surface at the cut edge appeared slightly elevated (</=35 microm) in the Er:YAG group. CONCLUSION: Orientation teeth/notches resembling those obtained with the excimer laser can be created using the Q switched Er:YAG laser, with potential advantages of lower costs, convenient equipment size, and solid state safety.

Animals↗

Zernike representation of corneal topography height data after nonmechanical penetrating keratoplasty.

PURPOSE: To demonstrate a mathematical method for decomposition of discrete corneal topography height data into a set of Zernike polynomials and to demonstrate the clinical applicability of these computations in the postkeratoplasty cornea. METHODS: Fifty consecutive patients with either Fuchs' dystrophy (n = 20) or keratoconus (n = 30) were seen at 3 months, 6 months, and 1 year (before suture removal) and again after suture removal following nonmechanical trephination with the excimer laser. Patients were assessed using regular keratometry, corneal topography (TMS-1, simulated keratometry [SimK]), subjective refraction, and best-corrected visual acuity (VA) at each interval. A set of Zernike coefficients with radial degree 8 was calculated to fit two model surfaces: a complete representation (TOTAL) and a representation with parabolic terms only to define an approximate spherocylindrical surface (PARABOLIC). The root mean square error (RMS) was calculated comparing the corneal raw height data with TOTAL (TOTALRMS) and PARABOLIC (PARABOLICRMS). The cylinder of subjective refraction was correlated with the keratometric readings, the SimK, and the respective Zernike parameter. Visual acuity was correlated with the tilt components of the Zernike expansion. RESULTS: The measured corneal surface could be approximated by the composed surface 1 with TOTALRMS < or = 1.93 microm and by surface 2 with PARABOLICRMS < or = 3.66 microm. Mean keratometric reading after suture removal was 2.8+/-0.6 D. At all follow-up examinations, the SimK yielded higher values, whereas the keratometric reading and the refractive cylinder yielded lower values than the respective Zernike parameter. The correlation of the Zernike representation and the refractive cylinder (P = 0.02 at 3 months, P = 0.05 at 6 months and at 1 year, and P = 0.01 after suture removal) was much better than the correlation of the SimK and refractive cylinder (P = 0.3 at 3 months, P = 0.4 at 6 months, P = 0.2 at 1 year, and P = 0.1 after suture removal). Visual acuity increased from 0.23+/-0.10 at the 3-month evaluation to 0.54+/-0.19 after suture removal. After suture removal, there was a statistically significant inverse correlation between VA and tilt (P = 0.02 in patients with keratoconus and P = 0.05 in those with Fuchs' dystrophy). CONCLUSIONS: Zernike representation of corneal topography height data renders a reconstruction of clinically relevant corneal topography parameters with a marked reduction of redundance and a small error. Correlation of amount/axis of refractive cylinder with respective Zernike parameters is more accurate than with keratometry or respective SimK values of corneal topography analysis.

Adolescent↗

Stromal thermal effects induced by nonmechanical (2.94-mum) erbium:YAG laser corneal trephination.

OBJECTIVE: To determine stromal thermal changes after erbium (Er):YAG laser corneal trephination with the use of 2 open masks. METHODS: Corneal trephination was performed in 89 enucleated pig eyes with an Er:YAG laser (400-microsecond pulse duration), 4 open masks (2 metallic and 2 ceramic) for both donors and recipients, and an automated globe rotation device. Different combinations of laser settings were used: pulse energy, 100, 200, and 400 mJ; repetition rate, 2 and 5 Hz; and spot size, 1.3 and 3.2 mm. Thermal effects in corneal stroma and regularity of the cut edges were quantitatively assessed by light microscopy, transmission and scanning electron microscopy. RESULTS: Best regularity and minimal thermal effects of the cut were observed with the use of ceramic masks at 200 mJ, 2 Hz, and 3.2-mm spot size, with middepth thermal changes of 18 +/- 2 microm. Effects increased with cut depth and were lower in donor corneas and with the use of ceramic masks (P<.001). Regularity of the cut was higher in the donors (P = .05) with lower repetition rates (P<.001). CONCLUSIONS: Even with the "free-running" Er:YAG laser mode, features of the trephination cut resembling those created by the 193-nm excimer laser along metal mask were achieved. Ceramic masks may be more suitable than metal masks. The Er:YAG laser seems to have the potential to be a compact and low-cost alternative in nonmechanical trephination for penetrating keratoplasty. CLINICAL RELEVANCE: Thermal effects after corneal trephination with the free-running Er:YAG laser (2.94 mm) are limited and predictable.

Animals↗

[Immunologic transplant reactions after non-mechanical corneal trepanation with the excimer laser].

BACKGROUND: Nonmechanical trephination has been established as the standard procedure in penetrating keratoplasty (PK) for avascular corneal diseases at our institution. The purpose of this study was to analyze the incidence and reversibility of immunologic graft reactions after nonmechanical trephination and to detect potentially causative factors. PATIENTS AND METHODS: Out of a total series of 400 nonmechanical PKs, 286 consecutive procedures with sufficient follow-up performed between 07/1989 and 09/1997 were included in the study (104 x keratoconus, 78 x Fuchs' dystrophies, 31 x bullous keratopathies, 28 x ulcers, 25 x avascular scars, 12 x stromal dystrophies, 4 x buphthalmos, 4 x others; 202 x PK only, 84 x combined procedures; 276 first PK). The age of the 138 females and 148 males at the time of surgery ranged from 16 to 89 (mean 55 +/- 19) years. The recipient and donor trephinations were performed from the epithelial side using an 193-mm excimer laser (MEL50 or MEL60, Aesculap-Meditec, 1.5 x 1.5 mm spot mode, 16-24 mJ/pulse, repetition rate 30 or 25/s; metal masks). The shape of the recipient trephination was either circular with four or eight "orientation teeth" (n = 251; 5.0-8.0 mm diameter) or elliptical (n = 35, 6.0 x 7.0 to 7.5 x 8.5 mm diameter). In 62% of procedures fresh or short-term-preserved donor tissue was used, and in 38% of procedures the donor tissue was organ-culture-preserved. RESULTS: During a mean follow-up of 22 +/- 18 months (maximum 7.7 years), 10 acute diffuse (3 irreversible; 1.0%) and 3 chronic focal endothelial graft reactions occurred (4.5%) not earlier than 4 months and not later than 35 months after PK. Elective procedures (3.5%) resulted in significantly (P = 0.01) less reactions than acute corneal ulcers (14.3%). After 1, 2 and 3 years, the cumulative reaction rates (Kaplan-Meier values) were 1.3%, 6.3% and 13.9% in elective procedures, none of which, however, occurred after 26 elliptical trephinations. With fresh or short-term-preserved donor tissue (4.2%), graft reactions did not happen more frequently but earlier (12 +/- 6 months) than with organ-culture-preserved donor tissue (2.2%, 30 +/- 6 months). In patients with keratoconus (4.9%), reactions occurred more frequently (P = 0.05, LogRank) and earlier than in patients with Fuchs' dystrophy (1.3%). CONCLUSIONS: In addition to well-established optical advantages, nonmechanical trephination seems to have no immunologic drawbacks.

Adolescent↗

[Correlation between semi-quantitative classification of corneal topography and the coefficient of Fourier transformation after non-mechanical perforating keratoplasty].

BACKGROUND: Semiquantitative classification of corneal topography after penetrating keratoplasty has the potential for focusing information about the areal dioptric power of the cornea. The purpose of this study was to objectify the procedure of manual semiquantitative classification using a Fourier transform of corneal topography power data and to correlate both methods. PATIENTS AND METHODS: Fifty patients each (30 keratoconus, 20 Fuchs dystrophy) underwent nonmechanical trephination (excimer laser MEL60, Aesculap-Meditec, Jena) in penetrating keratoplasty. All procedures (7.5-mm trephination diameter in Fuchs, 8.0 mm in keratoconus, double-running 10-0 nylon suture) were done by one surgeon. Pre-, intra- and postoperative treatment were identical. At the follow-up examinations, the keratometric astigmatism, qualitative and quantitative criteria of the automatic videokeratography, visual acuity and refraction were assessed. Corneal topography was classified both manually and based on Fourier coefficients. RESULTS: After a mean follow-up of 24 +/- 5 months, keratometric net astigmatism was 3.0 and 2.7 D with keratoconus and Fuchs dystrophy. Corneal topography analysis showed a higher orthogonality of the bow-tie shape and less asymmetry between opposite hemimeridians with increasing follow-up after keratoplasty. The semiquantitative classification showed a statistically significant correlation with the classification based on Fourier coefficients, especially with higher astigmatism and after suture removal (P = 0.04/0.01 before/after suture removal). DISCUSSION: After nonmechanical trephination, the semiquantitative classification of corneal topography can be synthetized using Fourier analysis of corneal dioptric power data. In the future, this method may be favored for prediction of potential best-corrected visual acuity after penetrating keratoplasty.

Adult↗

Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty.

PURPOSE: To analyze whether nonmechanical trephination with an excimer laser influences post-operative blood-aqueous barrier breakdown after penetrating keratoplasty. METHODS: Patients undergoing penetrating keratoplasty for keratoconus or Fuchs dystrophy were prospectively randomly assigned to trephination by either excimer laser or conventional mechanical handheld motorized trephine. All surgery was performed by one surgeon, and preoperative, intraoperative, and postoperative treatment was identical in both groups. Aqueous flare was quantitatively determined postoperatively in a masked fashion by laser flare-cell meter. For statistical analysis, the nonparametric Wilcoxon-Mann-Whitney test was used. RESULTS: A total of 52 eyes of 52 patients were examined (Fuchs dystrophy, 10; keratoconus, 42). During the early postoperative period (days 3 to 9), eyes that had undergone nonmechanical excimer laser trephination (25/52) showed significantly (P < .005) lower flare values than did eyes that had undergone mechanical trephination (27/ 52). In both groups, flare values returned to normal levels by 6 weeks postoperatively. CONCLUSION: Early postoperative blood-aqueous barrier breakdown is less pronounced after penetrating keratoplasty with nonmechanical excimer laser trephination.

Adolescent↗

Experimental correction of irregular corneal astigmatism using topography-based flying-spot-mode excimer laser photoablation.

PURPOSE: To present a novel experimental approach for treating irregular corneal astigmatism. METHODS: After decomposition of topographic analysis data into orthogonal Zernike polynomials, a regular target surface was defined, and the ablation profile was calculated. In a polymethylmethacrylate with an irregular surface, computer-controlled ablation was performed using a 193-nm excimer laser in "flying-spot mode." RESULTS: The difference between flattest and steepest hemimeridians in the 3-mm zone, surface regularity index, and surface asymmetry index were reduced from 8.7 to 1.1 diopters, 1.19 to 0.39, and 1.84 to 0.14, respectively. CONCLUSION: Tying corneal topography into laser software offers a straightforward concept for correction of irregular corneal astigmatism in an experimental model.

Astigmatism↗

[Transplant vertical tilt after perforating keratoplasty--comparison between non-mechanical trepanation with excimer laser and motor trepanation].

BACKGROUND: Besides decentration of the graft/host trephination and "horizontal torsion" "vertical tilt" is an important factor for reduced visual outcome after penetrating keratoplasty (PK). The purpose of this study was to evaluate the time course of vertical tilt in absolute value and direction and to correlate it with functional results after PK. PATIENTS AND METHODS: Fifty patients each (20 primary dystrophies, 30 keratoconus) underwent nonmechanical trephination (NMT) (excimer laser MEL60, Aesculap-Meditec, Heroldsberg, Germany) or mechanical motor trephination (MT) (Geuder, Heidelberg, Germany) in penetrating keratoplasty. All procedures (7.5 mm in dystrophies, 8.0 mm in keratoconus, 8 orientation teeth in NMT, double-running 10-0 nylon suture) were performed by one surgeon (GOHN). At a postoperative gate of 6 weeks, 6 months, before partial suture removal and after complete suture removal, corneal topography analysis (TMS-1, Tomey, Tennenlohe, Germany) was performed. After a Gram-Schmidt-orthogonalization corneal topography height data of 25 noncentric rings in 256 hemimeridians were decomposed into Zernike components of radial order n = 16 in the sense of minimizing the root mean square error. The tilt of the surface relative to the videokeratoscope axis was calculated from the Zernike components Z1(1) and Z1(-1). The meridional power at the cardinal meridians was derived from all parabolic Zernike terms. Tilt and the difference between both meridians of the Zernike representation (ZA) were correlated with the results of Zeiss keratometry (KA). Simulated Keratometry (SimK) of the TMS-1, subjective refraction (RZ) and best-corrected visual acuity. RESULTS: After NMT, vertical tilt of the graft was 3 degrees without significant change over time. Following MT, an equivalent time course could be observed before partial suture removal. However, after complete suture removal, a significant increase of the tilt was measured to 5 degrees (p = 0.02). No significant difference could be detected comparing keratoconus and Fuchs' dystrophy both in NMT and MT. The direction of the vertical tilt component piled up to the hemimeridian defined by the knot of the first running suture. At all postoperative follow-up examinations, the ZA of the Zernike decomposition showed a good correlation to the RZ, whereas the KA and the SimK did not. At the end of the follow-up, best-corrected visual acuity after NMT was 2 decimal lines better than after MT. CONCLUSIONS: The Zernike decomposition of topographic height data is a suitable tool for extraction and quantifying vertical tilt of the graft following penetrating keratoplasty. In contrast to conventional keratometry with its 4-point measurement, a decomposition of topographic height data into orthogonal polynomials enables a detection of both cardinal meridians even in corneas with a high degree of local irregularities.

Adolescent↗

[Interpretation of corneal topography after penetrating keratoplasty with wave-front parameters--comparison between non-mechanical trepanation with excimer laser and motor trepanation].

BACKGROUND: Besides irregular astigmatism characterized by the asymmetric components of the corneal surface, the aberration of the cornea from an ideal sphere degrades the optical performance of the "optical system eye". Best-corrected visual acuity may be markedly decreased with an increasing aperture diameter. The purpose of this study was to evaluate the time course of the symmetrical part of the aberration from an ideal sphere and to correlate it with functional results after penetrating keratoplasty (PK). PATIENTS AND METHODS: Fifty patients each (20 primary dystrophies, 30 keratoconus) underwent nonmechanical trephination (NMT) (excimer laser MEL60, Aesculap-Meditec, Heroldsberg, Germany) or mechanical motor trephination (MT) in penetrating keratoplasty. All procedures (7.5 mm in dystrophies, 8.0 mm in keratoconus, 8 orientation teeth in NMT, double-running 10-0 nylon suture) were performed by one surgeon (GOHN). At a postoperative gate of 6 weeks, 6 months, before partial suture removal and after complete suture removal, corneal topography analysis (TMS-1, Tomey, Tennenlohe, Germany) was performed. After a Gram-Schmidt-orthogonalization, corneal topography height data of 25 noncentric rings in 256 hemimeridians were decomposed into Zernike components of radial order n = 16 in the sense of minimizing the root mean square error. The symmetrical part of the deviation from an ideal spherical surface was calculated from the Zernike components Z4(0), Z6(0), ..., Z16(0). From the Zernike components, the longitudinal focus distribution and its standard deviation (SDF) was determined. SDF was correlated with the surface asymmetry index (SAI), the surface regularity index (SRI), the potential visual acuity (PVA) of the TMS-1 and the spectacle-corrected visual acuity. RESULTS: In the time course after PK, SDF decreased from the 6 weeks follow-up examination to the end of the follow-up from 1.27 mm to 0.77 mm in NMT (p = 0.01) and from 1.29 mm to 1.20 mm following MT (p = 0.24) within the central corneal region of 3 mm in diameter. The SAI did not depend on SDF, whereas the SRI correlated significantly inversely with the SDF within the 3 mm zone immediately before (p = 0.01 and p = 0.02) and after suture removal (p = 0.01 each) after NMT. After MT, only a mild inverse correlation was observed before (p = 0.05) and after suture removal (p = 0.04). In the time course after the 6 months follow-up the SDF within the 3 mm central area correlated inversely with the best-corrected visual acuity, more with NMT than with MT (p = 0.005 and p = 0.04 after suture removal). Best-corrected visual acuity was approximately 2 decimal lines better following NMT. CONCLUSIONS: Zernike decomposition of corneal topography height data allows a separation and quantification of aberration of corneal graft surface from an ideal sphere. Although corneal surfaces with a high degree of local irregularities can be decomposed due to the orthogonality condition. Following NMT, SDF was markedly lower after suture removal.

Adult↗

[Topography-assisted correction of superficial irregularities of the cornea with the excimer laser].

BACKGROUND: A retinal image performance distorted by an asymmetric or irregular corneal surface cannot be compensated for with spherocylindric glasses completely. The best-corrected visual acuity is markedly decreased and contact lens fitting often impossible. The purpose of this study was to calculate the differential height between corneal topography raw data and any regular surface with mathematical methods in order to ablate the differential height with a computer-controlled laser beam, thereafter. METHODS: A Zernike decomposition of radial degree n = 16 was realized within a clinically relevant central corneal area of 8 mm in diameter based on corneal topography raw height data of a commercially available topographer (TMS-1, Tomey, Erlangen). Any target surface could be defined by varying weighting of the Zernike coefficients. The calculated differential height ablation between the raw data and the target surface given in a polar grid was transformed to a Cartesian grid to evaluate the sleeping time at each grid position considering the characteristic ablation curve for the intended ablation of the height difference. Subsequently, differential height ablation was simulated using an automated laser beam control for a modified excimer laser (MEL60, Aesculap-Meditec, Jena). We developed software tools for Zernike decomposition of corneal topography raw height data and time-regulated automatic laser beam control of the grid positions in the higher programming language C (Borland C++ 3.1, Borland Inc., München). RESULTS: Definition of a target surface can be realized alternatively by selecting a set of Zernike coefficients or defining a spherical or spherocylindrical surface by superposition of parabolic terms in a fixed proportion creating a best-fit target surface to the raw data. In originally "relatively flat" areas, the differential height profile indicates a "relatively deep" ablation resulting in relative steepening towards the periphery of the ablation zone. The resolution of the mechanical unit of the laser beam control consisting of two linear stepping motors is 9 microns in the focal plane with a reproducibility of 5 microns. The software unit is guiding the laser beam in a meandering fashion within the ablation area considering the calculated sleeping time for each grid position. Mean overlap of the 1 mm laser spots is 70%. The laser beam diameter of 1 mm effects a peripheral transition zone of 0.5 mm. CONCLUSIONS: Zernike decomposition of corneal topography height data is an efficient tool for localizing and quantifying superficial irregularities and for directly calculating an ablation profile from created differential height data. With an automatic laser beam control a well-defined laser ablation of superficial corneal irregularities is possible, subsequently.

Astigmatism↗

[Design and preliminary results of the Erlanger non-high-risk penetrating-keratoplasty study].

PURPOSE: The purpose of this prospective study is to examine the non-high-risk penetrating keratoplasty clinically, tyndallometrically and immunological-serologically in order to learn more about the pathogenesis, early symptoms and therapy monitoring of corneal graft rejection. PATIENTS AND METHODS: Since february 1997, patients undergoing non-high-risk-PK have been enrolled in this prospective study. Examinations are done preoperatively and in well-defined postoperative gates (6 weeks, 3 months, 6 months, etc.) and include clinical assessments, corneal topography, laser-tyndallometry, corneal endothelial cell count and corneal pachymetry. Preoperatively as well as at each postoperative examination, 10 ml serum and perioperatively corneoscleral donor tissue are collected and frozen (-80 degrees C) to allow immunological and serological examinations in case of graft rejection later. A relational data base (MS Access) guarantees complete and homognous standardized clinical and serological data. We randomised our patients with respect to duration of topical steroid therapy in standard situations (short-time vs. long-time) as well as for systemic steroid therapy (bolus group vs. tapering group) in case of a graft rejection in 2 treatment groups. RESULTS: Up to March 1998, 99 patients have been enrolled in this prospective study. Our report includes the first consecutive 55 patients (25 female, 30 male, recipient age 56.9 +/- 19.4 years, donor age 57.0 +/- 19.9 years). Up to now (follow-up 2.5 +/- 2.1, maximum of 7.3 months) we did not observe immunologic graft rejections. In one patient a primary graft failure occurred. Laser tyndallometry showed a reduction of blood-aqueous barrier breakdown from 6 weeks postoperatively (9.3 +/- 5.7 photon counts/msec) to 3 months postoperatively (6.8 +/- 3.5 photon counts/msec). CONCLUSION: This prospective randomized clinical and immunological study after non-high-risk-PK is supposed to give more information about pathogenesis, early symptoms and therapy monitoring of graft rejection after elective PK. The concept and design of this study are described. Preliminary data may give significant results in a few years.

Adult↗

Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty.

PURPOSE: To study the morphologic properties of divergent cut angles after nonmechanical trephination for penetrating keratoplasty in donors and recipients and to assess its implications for donor-recipient stability in an experimental porcine model. METHODS: An excimer laser 193-nm corneal trephination was performed in 30 enucleated porcine eyes by using a modified "open mask" (stainless steel sheet 10CrNi18), to obtain round donor buttons and corresponding recipient beds 7 mm in diameter at the level of Bowman's layer. An automated globe-rotation device allowed different cut angles toward the optical axis. Three cut angles were intended: 0 degrees, 15 degrees divergent, and 35 degrees divergent. Quality of the cuts was assessed by means of histology and scanning electron microscopy (SEM). In a different setting, after alignment of the donor button and corresponding recipient bed in an artificial anterior chamber, intracameral pressure was increased stepwise, modifying the height of a bottle of balanced saline solution connected to the chamber. Criterion for "instability" was the movement of the donor button in all four quadrants during observation with a surgical microscope (x12). RESULTS: Reproducible cut angles and smooth cut surfaces of donors and recipients were confirmed by histologic and SEM evaluation. Macroscopically, a good alignment of a divergent donor button in a corresponding recipient bed was achieved. Instability of the donor buttons occurred with a water column niveau at 2 cm in the 0 degrees cut, at 3 cm in 15 degrees divergent cuts, and at 4.5 cm in 35 degrees divergent cuts. CONCLUSION: The stability of a corneal donor button in a recipient bed seems to increase in proportion with the degree of divergence of the trephination angle. Considering the good histologic quality and macroscopic alignment obtained, divergent cut angles may allow a reduction of sutures, assuring a water-tight wound closure in penetrating keratoplasty.

Animals↗