Search PubMed⌕ Search

Biomedical subjects

A Langenbucher

Publications and source records attributed to A Langenbucher.

At least 37 records · Page 2Linked to original sources

[Impact of an Er:YAG laser beam control on cut quality of non-mechanical corneal trepanation for penetrating keratoplasty].

BACKGROUND: Results of non-mechanical corneal trepanation using the excimer laser enhance the morphological and functional results for penetrating keratoplasty. Searching for alternative laser sources we assessed the impact of an automatic laser beam control for the Er:YAG solid-state laser on the cut performance and thermal damage zone in non-mechanical corneal trepanation. METHODS: We compared the cut quality of A) a manually guided laser beam, B) a semiautomatically guided laser beam and C) a fully PC-controlled laser beam positioning system (q-switched, repetition rate 5 Hz, pulse energy 65 mJ, spot size 0.7 mm) along slit aperture masks on 28 rabbit eyes using macroscopic images and histological sections (PAS staining). RESULTS: The manually guided laser beam control (A) induced the broadest thermal damage zone in the corneal stroma (19.3+/-8.7 microm) compared to the semi-automatic mode (B) (8.8+/-3.0 microm, p=0.03) and the PC-controlled laser beam control (C) (7.0+/-3.0 microm, p=0.016). CONCLUSION: The fully automatic PC-controlled laser beam positioning system for the Er:YAG solid-state laser with a small spot size and fixed low repetition rate allows a precise laser beam guidance and a significant enhancement of the cut performance compared to a manual laser beam control via micromanipulator in experimental nonmechanical corneal trepanation.

Animals↗

[Phototherapeutic keratectomy for recurrent corneal erosion syndrome (e-PTK). Report on 116 consecutive interventions].

BACKGROUND AND AIMS: Patients with recurrent corneal erosion syndrome can suffer both psychologically and socially due to excessive pain. After the failure of conservative treatment, conventional surgical interventions, such as anterior stromal puncture have been suggested. The purpose of this study was to assess the morphological and functional results of minimally invasive excimer laser phototherapeutic keratectomy (e-PTK) for treatment of recurrent corneal erosion syndrome and in particular, to evaluate the cumulative recurrence rate. PATIENTS AND METHODS: Between July 1990 and January 2001, 116 e-PTKs have been performed mostly in the acute stage of the disease in this single center study. In 15 eyes an unsuccessful PTK had previously been performed elsewhere. Reasons for the erosion included trauma ( n=80), Cogan's epithelial dystrophy ( n=14), bullous keratopathy ( n=2), and in 20 cases no cause could be detected. A manually guided spot profile was applied in 99 cases (pulse energy 10 mJ, repetition rate 2/s or 3/s, 66-330 pulses). In 17 cases a scanning slit procedure was applied (intended ablation per scan 1 microm, repetition rate 20/s, 447-1,017 pulses). The broad deepithelialisation of Bowman's layer was treated with defocussed overlapping laser pulses. RESULTS: Complete epithelial closure was achieved after an average of 2.3+/-1.3 (median 2) days, the mean follow-up was 2.2+/-1.6 years with a maximum of 5.6 years. Best corrected visual acuity increased from 0.6+/-0.4 preoperatively to 0.9+/-0.3 postoperatively. The keratometric central power remained constant (preoperative 43.0+/-2.2 D (diopters), postoperative 43.3+/-1.9 D). The median keratometric astigmatism remained constant at 1.0 D. Only in 2 patients was an iatrogenic, not completely reversible irregular astigmatism of more than 2 D induced during the learning curve. The spherical equivalent did not change significantly (-1.0+/-3.3 D preop., -1.1+/-3.4 D postop.). In 9 eyes (7.8%) a recurrent epithelial defect occurred after 2-24 (average 8+/-6) months. The cumulative 1-year recurrence rate was 6.5%, the 2-year recurrence rate was 11.5%, the 3-, 4-, and 5-year recurrence rates were all 13.6%. CONCLUSIONS: For recurrent corneal erosion syndrome, e-PTK performed with low pulse energy and low number of pulses can be considered an effective treatment modality to achieve a fast and mostly durable epithelial closure. Even after broad removal of the loose epithelium, change of refraction or induction of an irregular astigmatism with visual loss seems to be the exception.

Adult↗

[Two years experience with the new accommodative 1 CU intraocular lens].

After marked improvement of optical rehabilitation of cataract patients during the last decades due to small incision surgery and foldable intraocular lenses (IOL), presbyopia is now one of the great unsolved questions in ophthalmology. During recent years a new accommodative IOL, the 1CU lens, has been developed based on the concepts of K.D. Hanna and on finite element computer simulation models. The 1CU IOL is designed to transform contracting forces of the ciliary muscle into anterior movement of the IOL optic (optic-shift concept). After the first implantation of a 1CU IOL in Erlangen in June 2000, we have now successfully implanted the 1CU IOL in over 90 patients. Our experiences and the results of several clinical studies indicate good and safe implantability, good centration, no IOL-specific complications, and good distance visual acuity. In comparison to control groups with conventional IOL, patients with the 1CU enjoyed significantly better distance-corrected near visual acuity, a larger accommodative range, and increased anterior and posterior axial movement of the lens optic after medical stimulation or inhibition of the ciliary muscle. We interpret our results as confirmation of the optic-shift concept of the 1CU IOL. Overall, the concept of accommodative IOL appears attractive and may have a great potential in the future. Additional studies including randomized blind multicenter evaluation of the 1CU IOL are necessary to further evaluate long-term and accommodative results.

Accommodation, Ocular↗

[Morphological results after eccentric perforating keratoplasty].

OBJECTIVE: Due to unfavourable optical and immunological conditions, an eccentric position of the corneal transplant is limited to curative or tectonic indications. The purpose of this study was to assess the morphological results of eccentric homologous penetrating keratoplasty (PK) with respect to diagnosis as well as position and size of the corneal graft. PATIENTS AND METHODS: In our retrospective study, 122 cases of eccentric homologous PK in 96 eyes between 01/1989 and 10/1997 were included, which in 104 patients was necessary because of a corneal ulcer (36 previous PK, 21 areactive/rheumatic, 20 herpetic, 15 bacterial, 12 other). Elective PK was performed on 6 eyes with corneal scars, 7 eyes with ectatic corneal diseases (ECT) and 5 others. Using postoperative slides the following parameters were quantified: the graft diameter (GD) and transparency, the distance of the geometric centre of the cornea from the central trephination margin (ABS) as well as from the geometric centre of the graft (decentration, DEZ). Of these, 17 grafts were classified as eccentric peripheral keratoplasty (EPK) with the optical axis through the host cornea and 67 as eccentric central keratoplasty (ECK) with the optical axis through the graft. RESULTS: The average follow-up period was 25 months. In EPK (ulcers only, 5.0 +/- 1.7 mm) the mean GD was significantly lower than in ECK (78% ulcers, 7.0 +/- 1.3 mm) (p < 0.001). The decentration of EPK (3.5 +/- 1.1 mm) was significantly higher than for ECK (1.4 +/- 0.8 mm, p < 0.001). ABS of EPK was +1.3 +/- 0.9 mm and for ECK was -2.0 +/- 1.0 mm. Of the grafts in EPK and ECK 46%/57%, respectively were crystal clear, 18%/15% respectively showed minor decompensation and 36%/28% were completely cloudy. In cases of ulcers/scars/ECT/others, 45%/75%/100%/75% were crystal clear, respectively, 18%/25%/0%/0% showed minor decompensation and 37%/0%/0%/25% were completely cloudy. With increasing stages of cloudiness, the mean graft decentration increased from 1.4 +/- 1.1 mm (crystal clear) to 1.7 +/- 1.2 mm (minor decompensation) and 2.2 +/- 1.4 mm (completely cloudy). Transplants with greater GD (p = 0.04) and ABS (p = 0.01) were significantly more often clear. Ulcers were significantly more cloudy than scars/ECT (p < 0.01). The position of the graft and its cloudiness was not significantly correlated. CONCLUSION: The diagnosis leading to eccentric PK seems to have the greatest impact on long-term graft transparency. Our results indicate that an increasing decentration of the graft is not inevitably associated with an increasing probability of clouding. A central penetrating repeat keratoplasty may be considered in the non-inflamed interval after eccentric tectonic mini-keratoplasty.

Adolescent↗

[Modeling corneal topography with a subdivision scheme in keratoconus].

BACKGROUND: Videokeratoscopy is often unable to obtain complete data sets in cases of irregular or asymmetric corneal topography. Subdivision schemes are very common in computer graphics for completion and smoothing of surfaces. Based on a network of triangular facets a smooth and complete surface in a standard coordinate system can be derived from topographic raw data. PATIENTS AND METHODS: We examined 88 patients with keratoconus and 40 normal controls. Polygons and polyhedra were defined from videokeratoscopic height data, and a surface was modeled using a modified butterfly subdivision scheme for a nonuniform sampled grid. To assess the model quality topographic raw data were changed to missing values centrally (at the apex of the cone) and in four midperipheral quadrants. The target value was the root mean square error, comparing the remodeled value of the subdivision scheme to the raw data at the position of the missing values for each group. RESULTS: Due to the nonuniform mesh of our Placido-based topographer we used a dynamic adaptive model and the governing dynamic differential equation. With a single missing value, no difference was detected between normals and patients with keratoconus. For a missing area consisting of 13 raw data points, the remodeling error was significantly higher in patients with keratoconus than in normals. With the neighborhood of 13 missing data points, the apex of the cone was remodeled in both groups of patients with less precision than with the peripheral missing data. CONCLUSION: The locality of the equation systems to be solved and the easy calculation of explicit formulas for the normals may simplify ray-tracing techniques and make subdivision attractive for large datasets in corneal topography even with irregular patterns.

Adult↗

Graft endothelium and thickness after penetrating keratoplasty, comparing mechanical and excimer laser trephination: a prospective randomised study.

PURPOSE: To assess the impact of nonmechanical trephination on the graft endothelium and thickness after penetrating keratoplasty (PK). METHODS: Inclusion criteria for this prospective, randomised, cross-sectional, clinical study were: (1) Treatment between October 1992 and December 1997; (2) one surgeon (G.O.H.N.); (3) primary central PK; (4) Fuchs' dystrophy (diameter 7.5/7.6 mm) or keratoconus (diameter 8.0/8.1 mm); (5) graft oversize 0.1 mm; (6) no previous intraocular surgery; (7) 16-bite double-running diagonal suture. In 179 patients (mean age 51+/-18 years), PK was performed using either the 193-nm Meditec MEL60 excimer laser ("Excimer") along metal masks with eight "orientation teeth/notches" (53 keratoconus, 35 Fuchs' dystrophy) or motor trephination with the Mikrokeratron (Geuder) ("Control": 53 keratoconus, 38 Fuchs' dystrophy). For donor trephination from the epithelial side an artificial anterior chamber was used in both groups. In 27% of the excimer and 29% of the control group a triple procedure was performed. Specular microscopy (EM-1000, Tomey) and pachymetry (SP-2000, Tomey) were performed before removal of the first suture (0.4+/-0.2 years postoperatively), before (1.1+/-0.4 years) and after (1.7+/-0.6 years) removal of the second suture but before any additional surgical intervention. RESULTS: Endothelial cell count: Neither "two-sutures-in" (1953+/-426/1804+/-385 cells/mm2, p=0.13), "one-suture-in" (1629+/-439/1765+/-440 cells/mm2, p=0.27), nor "all-sutures-out" (1259+/-493/1294+/-532 cells/mm2, p=0.83) differed significantly between Excimer and Control. Graft thickness: Neither "two-sutures-in" (527+/-58/524+/-16 mucrom, p=0.89), "one-suture-in" (537+/-72/551+/-40 microm, p=0.86), nor "all-sutures-out" (576+/-53/565+/-62 microm, p=0.38) differed significantly between Excimer and Control. Cell count and corneal thickness were not significantly different comparing Fuchs' dystrophy and keratoconus or comparing PK only and triple procedures. Graft thickness and endothelial cell count correlated highly significantly inversely with "all sutures out" (P<0.0001). CONCLUSIONS: Excimer laser trephination from the epithelial side using an artificial anterior chamber in donors seems to have no disadvantages concerning the graft endothelium after PK. Endothelial cell loss was not increased in eyes with Fuchs' dystrophy compared with keratoconus or after triple procedures compared with PK only.

Adolescent↗

Blood-aqueous barrier breakdown after penetrating keratoplasty with simultaneous extracapsular cataract extraction and posterior chamber lens implantation.

BACKGROUND: The purpose of this study was to quantify breakdown of the blood-aqueous barrier (BAB) following penetrating keratoplasty (PK) with simultaneous extracapsular cataract extraction and posterior chamber lens implantation (triple procedure) and compare it with the alterations following PK only. METHODS: This study included 72 eyes after triple procedure and 227 eyes after PK only. The diagnosis for PK was Fuchs dystrophy in 39%, keratokonus in 44%, stromal corneal dystrophy in 3% and avascular corneal scars in 6% of cases. The postoperative topical steroid treatment was standardized in both groups. Aqueous flare was quantified using the laser flare-cell meter (FC-1000, Kowa) at defined postoperative intervals (10 days, 6 weeks, then every 3 months until 1 year postoperatively). Patients with conditions associated with impairment of the BAB were excluded from the study. RESULTS: In the early postoperative course, aqueous flare values (photon counts/ms) were significantly higher in patients with triple procedure (21.9 +/- 11.0) than in patients with PK only (9.8 +/- 3.2; P = 0.001). At 6 weeks postoperatively, aqueous flare returned to normal levels in patients after PK only (5.2 +/- 2.3), whereas patients with triple procedure still showed significantly increased flare values (10.8 +/- 5.6; P = 0.01). At 6 months postoperatively, aqueous flare values of patients with triple had returned to normal levels (6.8 +/- 3.8) and did not differ significantly from those after PK only (5.2 +/- 1.9; P = 0.09). CONCLUSION: Our results indicate that triple procedure causes a more extensive and longer-lasting breakdown of the blood-aqueous barrier than PK only. Quantification of aqueous flare with the laser flare-cell meter is useful in the postoperative follow-up after triple procedure. Further studies are required to investigate the clinical relevance of BAB breakdown on endothelial cell count and the incidence of subsequent immunological graft rejection.

Aqueous Humor↗

Impact of short-term versus long-term topical steroids on corneal neovascularization after non-high-risk keratoplasty.

PURPOSE: To analyze incidence and extent of corneal neovascularization (CN) after non-high-risk keratoplasty and to find out whether duration of postoperative topical steroid therapy (6 vs 12 months) affects CN, corneal endothelial cell count, pachymetry, aqueous flare values, and best-corrected visual acuity at 1 year after keratoplasty. METHODS: Patients of the prospective Erlangen non-high-risk keratoplasty study with available high-quality corneal photographs taken preoperatively and 1 year later were analyzed (n=136). Corneal photographs were evaluated by two independent observers in a standardized semiquantitative fashion. Slides were projected with 100x magnification and corneal vessels classified into five grades with regard to the limbus, sutures and host-graft junction in each of 12 corneal sectors. Incidence and extent of CN after keratoplasty and relation to short-term (0-6 months) versus long-term (0-12 months) postoperative topical steroid therapy were analyzed. The effect of duration of topical steroid therapy on corneal endothelial cell count, pachymetry, aqueous flare values, and best corrected visual acuity was also analyzed. Of the 136 patients, 69 (51%) were randomly assigned to short-term and 67 to long-term topical prednisolone acetate 1%. RESULTS: Fifty-eight percent of patients (n=79) developed a CN within 1 year after keratoplasty in at least one corneal sector (mean 3.1 +/- 2.2, range 1-10). At 1 year after keratoplasty, only in 12% of these patients did at least one vessel reach the host-graft junction or grow into the donor cornea, whereas in 51% vessels were seen beyond the outer suture ends of the double running suture without reaching the host-graft junction. In 37%, capillaries were located between limbus and outer suture ends. New vessels usually pointed directly or indirectly to the outer suture ends and usually were located around the 12 o'clock and 6 o'clock positions. There was no significant difference regarding incidence and extent of CN 1 year after keratoplasty between the long-term and the short-term group. Duration of topical steroid therapy had no significant effect on corneal endothelial cell count and thickness, aqueous flare values and best-corrected visual acuity at 6 and 12 months postoperatively (only at 12 months, corneas in the long-term treatment group were slightly thicker; P=0.03). Interobserver correlation of vessel assessment was 0.77 (Kendall's tau B). CONCLUSIONS: CN is a common phenomenon after non-high-risk keratoplasty. New vessels rarely reach the host-graft junction, most commonly develop from the 6 o'clock and 12 o'clock positions and are usually located between epithelium and Bowman's layer (i.e., at the level of the superficial suture). The direction of vessel growth from the limbus towards the outer suture ends suggests release of angiogenic factors in this area. Prolongation of topical steroid therapy after non-high-risk keratoplasty beyond 6 months in this study did not significantly influence incidence and extent of CN, corneal endothelial cell count, aqueous flare values and best-corrected visual acuity observed 1 year after keratoplasty.

Administration, Topical↗

Corneal thickness measurements with contact and noncontact specular microscopic and ultrasonic pachymetry.

PURPOSE: To evaluate the central corneal thickness values in normal and postkeratoplasty corneas with the new Topcon SP-2000P noncontact specular microscopic, contact specular microscopic, and the "common standard" ultrasonic pachymetry. METHODS: Central corneal thickness was determined in 119 eyes of 81 patients (73 normal eyes of 44 patients and 46 eyes after penetrating keratoplasty) first with a noncontact specular microscopic (Topcon SP-2000P; Topcon Corporation, Tokyo, Japan), then an ultrasonic (AL-1000; Tomey, Erlangen, Germany), and finally with a contact specular microscopic (EM-1000; Tomey, Erlangen, Germany) pachymetry two times each by the same investigator. RESULTS: Reliability of the central corneal measurements was equally high both in normal and in postkeratoplasty corneas with all of the instruments (Cronbach alpha = 0.99). Noncontact specular microscopic corneal thickness determination correlated significantly both with ultrasonic (r =.86, P <.0001) and contact specular microscopic pachymetry (r =.62, P <.0001). The ultrasonic pachymetry correlated well with the Tomey pachymetry (r =.69, P <.0001). The Topcon normal mean central corneal thickness value (542 +/- 46 microm) was 28 +/- 4 microm lower (P <.0001) compared with the ultrasonic data (570 +/- 42 microm), which was 68 +/- 1 microm lower (P <.0001) compared with Tomey thickness (638 +/- 43 microm). CONCLUSIONS: Central corneal thickness measurements with noncontact specular microscopic, contact specular microscopic, and ultrasonic pachymetry demonstrate that each of the instruments is reliable but cannot be simply used interchangeably.

Aged↗

Posterior corneal curvature changes after myopic laser in situ keratomileusis.

OBJECTIVE: To assess the posterior corneal power and asphericity changes after myopic laser in situ keratomileusis (LASIK) and to correlate these changes with the amount of correction and the residual stromal bed thickness. DESIGN: Prospective nonrandomized (self-controlled) comparative study. PARTICIPANTS: Fifty-seven eyes of 14 women and 15 men, mean age at the time of surgery 33 +/- 9 (range, 19-53) years with a spherical equivalent (SEQ) of -1.00 to -15.50 (mean, -5.07 +/- 2.81) diopters (DI). INTERVENTION: All procedures were performed with the Keratom II Coherent-Schwind excimer laser and and the Moria Model One microkeratome (150-microm head). Subjective refractometry, Orbscan slit scanning corneal topography analysis and pachymetry were performed before and 3 months after LASIK for myopia (n=35, -1.00 to -15.50 D, mean -4.75 +/- -3.07 D) or myopic astigmatism (n=22, sphere 0.00 to -9.75 D, mean -4.75 +/- 2.36 D; cylinder -0.75 to -3.50 D, mean -1.68 +/- 0.86 D). Intended ablation depth ranged from 12 to 108 (mean, 48 +/- 22) microm. Topographic raw data were decomposed into a set of Zernike polynomials as published in detail previously, and parameters potentially indicative for detection of a "mild keratectasia" were derived. MAIN OUTCOME MEASURES: Posterior central corneal power and asphericity before and after LASIK were compared, and changes of these variables were correlated with the SEQ change (deltaSEQ)and the residual corneal bed thickness RBT). RESULTS: The mean RBT after LASIK was 280 +/- 42 microm. Overall, change of posterior power (-6.28 +/- 0.22 D/ -6.39 +/- 0.23 D, P=0.02) was statistically significant and change of asphericity (0.98 +/-0.07/1.14 +/- -.20, P<0.0001) was highly significant. In eyes with RBT < or =250 microm, the average change of posterior central power (-0.20 +/- 0.10 D vs. -0.08 +/- 0.18 D) was significantly greater than in eyes with RBT >250 microm (P=0.003). The change of posterior corneal power correlated significantly with deltaSEQ (P=0.004) and the RBT (P=0.002). CONCLUSIONS: Increased negative keratometric diopters and oblate asphericity of the posterior corneal curvature suggest that mild "keratectesia" of the cornea may be common early after LASIK. Further stuudies with longer follow-up are required to clarify whether this biomechanical deformation is progressive and whether a residual bed thickness of >250 microm can completely prevent it.

Adult↗

[Wavelet representation of corneal topography data after nonmechanical penetrating keratoplasty--a clinical study].

BACKGROUND: Corneal surface irregularities may limit the visual outcome after penetrating keratoplasty (PK). Corneal topographers mainly render empirically derived and system-specific statistical indices for characterization of superficial inhomogeneities which may lack clinical evidence and make inter-system comparisons difficult. The purpose of this study was to detect and quantify focal surface irregularities of the cornea after nonmechanical PK by 2-dimensional wavelet decomposition based on corneal topography data. PATIENTS AND METHODS: Our study included 15 patients with keratoconus and 10 patients with Fuchs' dystrophy with all-sutures-out after penetrating keratoplasty. For trephination we used the excimer laser MEL60 (Aesculap-Meditec, Germany) (7.5/7.6 mm diameter in dystrophies, 8.0/8.1 mm in keratoconus, double-running 10-0 nylon suture). After suture removal a complete ophthalmological examination including OrbScan topography analysis (Orbtec, USA) was performed. The refraction data were extracted via "data recorder" and decomposed using 2-dimensional wavelet analysis methods (Daubechies-4-wavelets on five scales of resolution). Corneal irregularities were quantified (scale 1 = fine details to scale 5 = coarse details). RESULTS: All detail coefficients (horizontal, vertical and diagonal) correlated statistically significant with the "Irregular Astigmatism" provided by the OrbScan-system (p < 0.05). In scale 3 and 4 a relative maximum of the wavelet detail coefficients occurred, whereas the coefficients at scale 2 and 5 were significantly smaller. The horizontal and vertical detail coefficients correlated significantly inversely with the best-corrected visual acuity (p < 0.04). All detail coefficients were significantly lower in the patient group with keratoconus compared to Fuchs' dystrophy. CONCLUSIONS: Wavelet decomposition of corneal topography refraction data allows an analytical isolation and quantification of focal corneal superficial irregularities. This algorithm is independent of the currently used topography system and allows a smoothing of the raw data set adapted to scale of resolution and data compression.

Adult↗

[Standardized semiquantitative analysis of corneal neovascularization using projected corneal photographs--pilot study after perforating corneal keratoplasty before immune reaction].

BACKGROUND: A semiquantitative scheme for analysis of corneal neovascularization using projected corneal photographs is demonstrated and tested in a pilot study to analyze occurrence of corneal neovascularization in patients after perforating keratoplasty which subsequently developed transplant rejection. METHODS: Corneal photographs on the slit lamp with diffuse frontal illumination were obtained in a standardized technique. Slides were projected with 100 x magnification and analyzed twice with a 2 months interval. Corneal vessels were graded by two independent observers in each of 12 corneal sectors in a standardized fashion (grade 0: no vessels beyond limbus, 1: vessels between limbus and outer end of a double-running diagonal suture; 2: vessels between outer suture end and graft-host junction; 3: vessels reaching graft-host junction; 4: vessels within donor cornea). All patients with endothelial graft rejection of the prospective Erlangen non-high-risk keratoplasty study were included in a pilot study (1/1997-6/2000: 13 of 325; 4%). One patient without photographs available was excluded. Corneal photographs taken prior to surgery (n = 10), at the last 3 monthly-routine control before (10), at rejection episode (12) and one year later (10) were evaluated for corneal neovascularization. RESULTS: Interobserver correlation at the two assessments was 0.79 and 0.86 (Kendall's Tau B). Correlation between the assessments at the two analyses 2 months apart was 0.8. New vessels with diameter up to 6 microns can be detected. 8 of 12 analyzed patients (67%) with immune reaction after keratoplasty developed corneal neovascularization within 1 year after operation prior to transplant rejection in at least one corneal sector (2.1 +/- 1.9 sectors; 1-6). At time of rejection, new vessels reached the graft-host junction in 2 patients, in 1 patient vessels grew into the donor cornea, whereas in 8 the vessels were seen beyond the outer suture end without reaching host-graft junction (grade I: 1 patient). New vessels usually pointed to the outer suture ends of the double-running suture. CONCLUSIONS: Development of corneal neovascularization e.g. after keratoplasty can be assessed reliably using projected slides of corneal photographs at 100 x magnification. This method has the advantage of being more objective, precise and available compared to simple evaluation at the slit lamp. Postkeratoplasty corneal neovascularization seems to be common in non-high-risk eyes later developing transplant rejection. However, new vessels usually do not reach the host-graft junction. Whether neovascularization after keratoplasty demonstrates a risk factor for subsequent transplant rejection remains to be analyzed in a greater study.

Cornea↗

[Visual rehabilitation and intraocular pressure elevation due to immunological graft rejection following penetrating keratoplasty].

PURPOSE: Endothelial graft rejection and intraocular pressure elevation are the most common causes of graft failure following penetrating keratoplasty (PK). Aim of this study was to evaluate the visual rehabilitation and the development of intraocular pressure during and after graft rejection. PATIENTS AND METHODS: The study included 20 eyes of 20 patients (age 54.7 +/- 19.8 years) with endothelial graft rejection, that fulfilled the following inclusion criteria 1) graft rejection was diagnosed and treated in our department; 2) at least one year follow-up after graft rejection; 3) avascular corneal pathology. The mean follow-up was 23 +/- 14 months. According to the type of surgical procedure patients were classified in PK only (n = 15, one after cataract extraction), PK combined with extracapsular cataract extraction and intraocular lens (IOL) implantation (n = 1); PK combined with secondary IOL-implantation or IOL-exchange (n = 4). Standardized complete ophthalmological examinations were performed on a regular basis before, during the acute graft rejection und then regularly in a defined examination raster in an out-patient service with cornea specialization. RESULTS: The time interval between first symptom of 18 acute diffuse and 2 chronic focal graft rejection and start of treatment was 9 +/- 13 days. Best-corrected visual acuity (CVA) was 0.6 +/- 0.2 before graft rejection and decreased significantly at the time of diagnosis (0.2 +/- 0.2; p = 0.001). Six weeks after graft rejection CVA was 0.5 +/- 0.2 and remained almost stable until one year after rejection (0.6 +/- 0.3) in 16 patients with reversible graft rejection. Only 4 patients (20%) showed an irreversible graft failure requiring Re-PK. Intraocular pressure (IOP) was not elevated in 75% of the patients (n = 15) and did not need any antiglaucomatous treatment during and after the rejection phase. In 5 eyes (25%) (3 after PK combined with anterior chamber IOL-explantation and secondary posterior chamber IOL-implantation; 1 with secondary pseudoexfoliation glaucoma and 1 steroidal responder) IOP was elevated during graft rejection (26 +/- 7 mmHg), but was controlled by intensive topical antiglaucomatous treatment. CONCLUSION: Typically, the visual rehabilitation after graft rejection was good if the clinical signs were diagnosed just in time and treated adequately. There is no direct correlation between graft rejection and intraocular pressure elevation. However, the development of intraocular pressure elevation seems to be strongly associated with preexisting glaucoma, preexisting anterior synechiae and/or simultaneous anterior chamber lens implant removal. A careful patient management after PK plays an important role to prevent the development of irreversible graft failure due to graft rejection.

Acute Disease↗

[Effect of pupil size on longitudinal focal distribution after photorefractive keratectomy ].

BACKGROUND: Optical aberrations induced by the transition zone of a myopic photorefractive keratectomy (PRK) may degrade the image quality. The subjectively evaluated visual acuity and contrast sensitivity may be reduced significantly especially with mydriasis. The purpose of this study was to calculate the image forming properties of the eye using raytracing techniques of a spot light source based on topographic height data of a scanning slit videokeratoscope. METHODS: Refractive surfaces were calculated from raw height data sets of the anterior and posterior corneal surface measurements (Orbscan, Orbtec, USA). The characteristics of the residual refractive surfaces were derived from Navarro's eye model. The focal distance was calculated using the exact raytracing calculation. Point spread function was determined at the focal plane and at 5 (delta = 0.2 mm) parafocal planes in front of and behind the focal distance in accordance to the pupil diameter (2, 3 and 6 mm). The algorithm was applied to 11 selected eyes (6 left, 5 right) of 8 patients before and after PRK with myopia (n = 6) and myopic astigmatism (n = 5). RESULTS: Before PRK the focal distance did not decrease significantly with increasing pupil size (2 to 6 mm), but decreased significantly after PRK (-0.41 +/- 0.12 mm, p = 0.02). Preoperatively, the variance of the point spread function did not differ significantly between a 2 mm (0.046 +/- 0.015 mm) and a 6 mm (0.055 +/- 0.021 mm) pupil size but was affected significantly by the pupil size postoperatively (2 mm: 0.049 +/- 0.018 mm, 6 mm: 0.096 +/- 0.045 mm, p = 0.04). CONCLUSIONS: Raytracing of corneal topography height data based on refined eye models with the option of calculation of the focus has the potential of tracing the optical resolution of the eye as a function of the pupil size. Due to of the altered surface geometry of the cornea after myopic PRK, both the variance of the point-spread function and the depth of focus increase with pupil size. This may be an explanation for impaired subjective refractometry and reduced contrast sensitivity of the patient after conventional keratorefractive surgery.

Adult↗

[First results of implantation of a new, potentially accommodative posterior chamber intraocular lens].

PURPOSE: Conventional posterior chamber intraocular lenses (PCIOL) generally provide excellent visual acuity but do not restore accommodation. A new, potentially accommodative PCIOL has been designed after principles elaborated by K.D. Hanna using finite element models. However, before newly developed PCIOL may be implanted routinely in larger numbers of patients, careful and meticulous evaluation in clinical studies is necessary. Thus, it was the aim of this study to investigate intra- and early 3-month postoperative findings after implantation of the newly designed PCIOL. PATIENTS AND METHODS: In a prospective pilot and safety study that was approved by the ethics committee of our university, six eyes of six patients (2 males, 4 females, age range 54 to 87 years) with senile or presenile cataract underwent phacoemulsification and implantation of the new PCIOL by one surgeon between June and November 2000. The PCIOL (1 CU, HumanOptics AG, Erlangen, Germany) is a one-piece hydrophilic acrylic foldable lens with an optic diameter of 5.5 mm. Modified haptics are intended to allow anterior movement of the lens optic as a function of contraction of the ciliary muscle. Intra- and early postoperative findings obtained after one and two days, one, two and six weeks and 3 months postoperatively were documented prospectively. Postoperative examinations included recording of distance and near visual acuity both obtained with best distance correction, determination of subjective near point and measurement of distance and near refraction by streak retinoscopy. Follow-up was at least three months in all patients. RESULTS: Surgery was uncomplicated in all patients with successful in-the-bag implantation and good centration of the PCIOL. The postoperative course was uncomplicated without inflammation, hemorrhage, synechiae or decentration. Visual acuity improved in all patients according to the status of the macula with values between 20/200 (atrophic maculopathy) and 20/20. After three to six months we observed a difference between retinoscopic near and distance refraction of 0.625 to 1.875 D and subjective near points of 40 to 100 cm. Near visual acuity with distance correction ranged from 0.1 or J 16 (atrophic maculopathy) to 0.4 or J 7. CONCLUSIONS: These early and preliminary results of our small pilot study are encouraging. Our findings may indicate at least some degree of pseudophakic accommodation. However, further studies with additional methods of measurements, with longer follow-up, more patients and controlled studies with control groups are essential to further determine safety and potential accommodative power of this new PCIOL.

Accommodation, Ocular↗

[Impact of pterygium size on corneal topography and visual acuity - a prospective clinical cross-sectional study].

PURPOSE: Pterygia may cause topographic changes featuring increase of astigmatism. The purpose of this study was to quantify the impact of the head-limbus-distance (=height) and limbal base length of the pterygium on the anterior corneal curvature and visual acuity before excision. PATIENTS AND METHODS: In 52 eyes (19 female, 33 male) with a mean age of 53 +/- 14 years the pterygium size (height, base length, area) was quantified using projected preoperative clinical slides and was correlated with visual acuity, refractive, keratometric, topographic astigmatism and Surface Regularity Index (SRI), Surface Asymmetry Index (SAI) of the TMS-1 videokeratoscope. RESULTS: The mean height of the pterygium was 3.1 +/- 1.4 (0.8 to 6.7) mm, the mean base length was 5.1 +/- 1.4 (2.9 to 7.8) mm, the estimated mean area was 11.4 +/- 6.9 (2.1 to 29.4) mm(2). The increasing pterygium height and area resulted in a highly significant elevation of the preoperative SRI and SAI values (p </= 0.01). The amount of keratometric (p=0.02) and topographic astigmatism (p=0.001) correlated significantly with height and area of the pterygium. In addition, pterygium size correlated significantly with the differences of zonal corneal power between steepest and flattest hemimeridian in the 3-mm zone or 5-mm zone, respectively (p </= 0.01). Best-corrected visual acuity and height/area of the pterygium correlated significantly inversely (p=0.001). Visual acuity seemed to be mostly unaffected up to a height of 2.5 mm. Overall, the impact of the base length was much less striking. Topographic astigmatism (3.3 +/- 2.8 D) was significantly larger than keratometric astigmatism (2.1 +/- 2.1 D) (p=0.001). The larger the pterygium, the larger was the difference between keratometric astigmatism and subjectively tolerated spectacle cylinder (p </= 0.01). CONCLUSIONS: Increasing distance of the pterygium head from the limbus results in increased amount and irregularity of preoperatively induced corneal astigmatism. This may explain the patient's decrease in visual acuity before the pterygium reaches the optical axis. Our data may help to determine the adequate time point for primary pterygium excision.

Adult↗

[Immunological graft reactions after penetrating keratoplasty - A prospective randomized trial comparing corneal excimer laser and motor trephination].

BACKGROUND AND PURPOSE: Nonmechanical trephination has been established as an advantageous procedure in penetrating keratoplasty (PK) for avascular corneal diseases and has been performed successfully in more than 1000 eyes at our institution. The purpose of this study was to compare incidence, type and reversibility of immunological graft reactions after mechanical and nonmechanical trephination for PK. PATIENTS AND METHODS: As part of a prospective randomized clinical trial 179 eyes of 76 females and 103 males were included, that had primary central PK without previous intraocular surgery between 10/1992 and 12/1997 for Fuchs' dystrophy (diameter 7.5 mm, n=73) or keratoconus (8.0 mm, n=106). The recipient and donor trephinations were performed from the epithelial side using either a motor trephine (Microkeratron, Geuder, n=91) or an 193-nm excimer laser (MEL60, Aesculap-Meditec, 1.5 x 1.5 mm spot mode, 16 - 24 mJ/pulse, repetition rate 25/s) along round metal masks with 8 "orientation teeth/notches" (n=88). As a routine, donor oversize was 0.1 mm. 128 patients (72 %) had PK only, 51 patients had simultaneous cataract extraction and PC-IOL implantation (triple procedure). Wound closure was achieved using a 16-bite double running diagonal suture by one surgeon (G.O.H.N.). In 53 % of procedures short-term-preserved donor tissue, in 47 % organ-cultured tissue was used. The mean patient/donor age was 51 +/- 17/57 +/- 19 years with nonmechanical trephination and 50 +/- 19/58 +/- 20 years with mechanical trephination. Incidence, type and reversibility of endothelial immunologic graft reactions were recorded continuously by clinical follow-up in an outpatient service with cornea specialization (after 6 weeks, then every 3 months until after suture removal, then every half year). RESULTS: During a mean follow-up of 40 +/- 15 months, 7.3 % of eyes developed an immunological endothelial graft reaction. Acute diffuse (5.6 %) were more frequent than chronic focal reactions (1.7 %). Only 1.7 % of grafts became irreversibly cloudy. More than 80 % of all graft reactions occurred later than one year (on average 23 +/- 13 months) after PK. Neither incidence (p=0.82, Chi square test) nor cumulative 3-year-rate of immunological graft reactions (p=0.91, LogRank test) differed significantly comparing nonmechanical (6.8 % or 7.3 %) and mechanical (7.7 % or 5.6 %) trephination. In eyes with keratoconus (6.6 %, 16 +/- 8 months) graft reactions did not occur more frequently (p=0.68) but earlier (p=0.02) than in eyes with Fuchs' dystrophy (8.2 %, 31 +/- 11 months). Donor age, post-mortem-time and preservation period did not significantly affect the rate of graft reactions in our study setting. CONCLUSIONS: Besides well-established optical advantages, nonmechanical trephination using the excimer laser seems to have no immunologic drawbacks in contrast to conventional mechanical trephination. Donor parameters appear to have no major impact on the incidence of graft reactions after non-high-risk PK. Rather, an adequate postoperative therapy with topical steroids, an informed patients' compliance, a consequent long-term follow-up in a clinical out-patient service with corneal specialization and a good education of and cooperation with the referring ophthalmologists are of utmost importance for the clear corneal graft in the long run.

Adolescent↗

[Conventional versus digital planimetry of optic disc photograph: a clinical comparative study].

BACKGROUND: The optic disc size is an important parameter for the diagnosis of glaucomatous and non-glaucomatous optic nerve damage. The aim of this study was to compare quantitative measurements of the optic disc with the established conventional planimetry and a new digital method using Soft imaging system analySIS(tm) for Ophthalmology and to determine the reproducibility of this new method. PATIENTS AND METHODS: Fifty color stereo optic disc photographs of 50 patients (mean age 41.7 +/- 13.4 y) were included in the retrospective, comparative study. Conventional and digital planimetry was taken from one skilled examiner in a masked fashion. According to patient's number measurement values obtained with both methods were matched. Digital planimetric measurements of 10 optic disc photographs were repeated on day 7 and day 14. Statistical analysis was done using linear regression analysis, reliability coefficient and U-test. RESULTS: The planimetric values did not vary significantly between the two methods for optic disc area (3.19 +/- 0.65 mm(2) vs. 3.03 +/- 0.64 mm(2), p=0.96), for cup area (1.36 +/- 0.62 mm(2) vs. 1.21 +/- 0.63 mm(2), p=0.96) or for neuroretinal rim area (1.83 +/- 0.39 vs. 1.82 +/- 0.41 mm(2), p=0.98). There was also no significant difference of horizontal and vertical diameter of optic disc and cup as well as the diameter of the superior temporal and inferior temporal retinal artery and vein at the optic disc border between both methods (p < 0.5). Differences between measured values for optic disc, optic cup area and neuroretinal rim area obtained with both methods were 0.16 +/- 0.10 mm(2) (range - 0.05 to 0.24), 0.15 +/- 0.10 mm(2) (range - 0.12 to 0.26) and 0.014 +/- 0.11 mm(2) (range - 0.26 to 0.26). A high correlation of all planimetric values was observed between both methods (r=0.9, p < 0.0001). Using digital planimetry differences between day 1, day 7 and day 14 were 0.05 +/- 0.03 (range 0.02 to 0.10 mm(2)) for optic disc, 0.05 +/- 0.04 (range 0.0 to 0.13 mm(2)) for optic cup area and 0.05 +/- 0.05 (range 0.01 to 0.14 mm(2)) for the neuroretinal rim area. The reliability coefficient of digital planimetry was 0.9 for optic disc parameters. CONCLUSIONS: The comparable results between both methods and a high reproducibility suggest that the digital planimetry could be used either for clinical routine or scientific evaluation of the optic nerve.

Adult↗