Search PubMed⌕ Search

Biomedical subjects

A Landers

Publications and source records attributed to A Landers.

11 recordsLinked to original sources

Photoelectron-photoion momentum spectroscopy as a clock for chemical rearrangements: isomerization of the di-cation of acetylene to the vinylidene configuration.

We have used complete correlated momentum mapping of the photoelectron and heavy ion products from the dissociation of the di-cation of acetylene, induced by photoionizing the carbon K shell of one of the atoms, to map out the angular correlation between the electron and the axis of the target molecule. The (quasi-) symmetric decay is found to proceed through both acetylene and vinylidene configurations. By using the strongly peaked photoelectron emission to "start a clock," an upper limit of 60 fs is placed on the isomerization time from the acetylene to the vinylidene configuration.

Journal Article↗

Photoelectron diffraction mapping: molecules illuminated from within.

We demonstrate the use of a multiparticle coincidence technique to image the diffraction of an electron wave whose source is placed at a specific site in a free molecule. Core-level photoelectrons are used to illuminate the molecule from within. By measuring the vector momenta of two molecular fragments and the photoelectron, a richly structured electron diffraction pattern is obtained in a body-fixed frame of the randomly oriented molecule in the gas phase. We illustrate this technique for CO, creating a photoelectron from the C(1s) shell and scanning its energy from zero to 30 eV.

Journal Article↗

Blue-yellow colour vision in an onchocercal area of northern Nigeria.

AIM: To determine if the City University Tritan Test is a useful addition to visual function assessment in rural communities in northern Nigeria. METHODS: The study was a cross sectional survey. The participants were 8394 people, aged 5 years and over, living in 37 rural communities, mesoendemic and nonendemic for onchocerciasis, in Kaduna State in northern Nigeria. The main outcome measures were the detection of a defect in blue-yellow colour vision by two criteria: (1) failure with the City University tritan screening plates; (2) failure with the City University grading plates to identify severe tritan defects. RESULTS: 91% of those aged 10 years and above could perform the test. Below this age, there were difficulties in comprehension. The test showed good inter- and intraobserver agreement. After adjustment for confounders the odds of failing the screening plates were significantly increased in the presence of optic atrophy or glaucoma (3.55 (2.48-5.08) and 15.9 (4.22-60.2) respectively). There was a greater increase in the adjusted odds of failing the grading plates in the presence of optic atrophy or glaucoma (5.30 (2.97-9.45) and 8.87 (1.61-48.7) respectively). Cataract had a smaller effect on the screening plates, adjusted odds 1.63 (0.95-2.80). CONCLUSION: Blue-yellow colour vision testing is a useful addition to visual function assessment in those aged 10 years and above in rural northern Nigeria, particularly in the detection of optic nerve disease.

Adolescent↗

Low vision.

Explore the source record for details and available documents.

Humans↗

Localizer for retinal detachment surgery.

A new mechanical localizer for retinal detachment surgery has two modes of action. The localizer is positioned under visualization in the undepressed state to avoid engaging or marking sclera until the surgeon elects to depress the marking pick after optimum localization.

Humans↗