Search PubMed⌕ Search

Biomedical subjects

A Kenny

Publications and source records attributed to A Kenny.

At least 37 records · Page 2Linked to original sources

Hospital outpatient and emergency services in rural Victoria.

Outpatient and emergency services in rural hospitals have rarely been studied. This paper analyses routinely collected data, together with data from a survey of hospitals, to provide a picture of these services in Victorian public hospitals. The larger rural hospitals provide the bulk of rural outpatients and emergency services, particularly so for medical outpatients. Cost per service varies with the size of the hospital, possibly reflecting differences in complexity. Funding policies for rural hospital outpatient and emergency services should be sufficiently flexible to take into account the differences between rural hospitals.

Data Interpretation, Statistical↗

Three-dimensional echocardiographic reconstruction of mitral valve color Doppler flow events.

In vitro studies have suggested superior accuracy of 3-dimensional echocardiography over conventional methods for the characterization and quantitation of color Doppler flow events. Little in vivo work has been reported in this area; this study demonstrates the feasibility of 3-dimensional reconstruction of mitral valve flow events in an unselected group of adult patients and discusses optimal instrument settings for the acquisition of 3-dimensional datasets.

Adult↗

Dobutamine stress echocardiography: improved endocardial border definition and wall motion analysis with tissue harmonic imaging.

BACKGROUND: We performed a study to determine whether tissue harmonic imaging (THI) facilitates wall motion analysis at rest and whether these benefits extend through the stages of a dobutamine stress echocardiography (DSE) study. We also assessed the impact of THI on the feasibility of DSE in technically difficult patients. Finally we tested the hypothesis that THI by improving endocardial border definition (EBD) could enhance the interobserver agreement between trainees and experienced operators for interpreting DSE studies. METHODS: Twenty unselected patients underwent DSE by standard protocol. Parasternal and apical views were obtained with the use of fundamental mode (FND) and THI at baseline, low dose, and peak stress. Segmental EBD was characterized as 1 to 4 (1 = excellent) and segmental wall motion was characterized as 1 to 4/x (1 = normal, x = unable to interpret) by a consensus of 2 experienced observers. A trainee in stress echocardiography independently scored all segments, and these results were compared with the consensus of the experienced readers. RESULTS: EBD improved with THI in 26 +/- 6.7 of 48 segments per patient (54%, 95% confidence interval [CI] 0.40 to 0.68) and deteriorated with THI in only 2 +/- 2.7 (4%, 95% CI 0 to 0.09). Of the total of 48 segments per patient, a mean of 10 +/- 5.7 (21%, 95% CI 0.10 to 0.31) were of inadequate quality to be interpreted for wall motion on FND, and this changed to 4 +/- 3.4 (6%, 95% CI 0.06 to 0.12) on THI (P <.001). EBD improved in a similar degree in all DSE stages 53%, 54%, and 53% for rest, low dose, and peak stress, respectively. Six of the 20 study patients were deemed unsuitable for DSE on FND, and all were changed to suitable subjects on THI. Of the 205 segments deemed unsuitable for interpretation on FND, 140 (68%) were of the anterior and lateral walls of the LV. Improvement with THI was also more prominent on these walls. The mean coefficient of agreement (kappa) for wall motion analysis was 0.82 +/- 0.14 on FND and improved to 0. 92 +/- 0.09 on THI (P <.001). CONCLUSIONS: THI dramatically improves EBD and the ability to confidently score segmental wall motion. Interobserver agreement is also significantly enhanced. These benefits extend to the peak stage of a DSE study. Routine use of THI may enhance the diagnostic accuracy of DSE and extend its application to technically difficult patients previously deemed unsuitable.

Adult↗

Acoustically stimulated transient power scattering explains enhanced detection of the very low velocities in myocardial capillaries by power Doppler imaging: an in vitro study.

BACKGROUND: Although enhanced detection of myocardial perfusion signals by power Doppler imaging during contrast echocardiography has been noted, flow velocities in the coronary microvasculature should generally be below the threshold for Doppler motion detection. It has been suggested that in this situation nonlinear scattering related to acoustically stimulated microsphere oscillation or destruction may be responsible for the detected Doppler shift. METHODS AND RESULTS: This study examined the behavior of MRX 115 (ImaRx Pharmaceuticals) microbubbles during harmonic and nonharmonic power Doppler imaging at varying power outputs (mechanical indexes 0. 3, 0.5, 0.7, and 0.9) in a perfusion tube model under zero-flow conditions. Boluses of MRX 115 0.5-mL suspension were introduced into the model, and flow was halted during each imaging period. Once power Doppler imaging was implemented, a signal was detected as unique sparkling color pixels corresponding to individual bubble destruction events, even in the absence of contrast movement. This phenomenon continued until all contrast bubbles disappeared from the region subjected to power Doppler imaging, usually within 35 to 40 seconds. Off-line videointensity measurements showed that initial power Doppler signal intensity and maximum signal decay rates increased parallel to increasing power output and were substantially greater for nonharmonic than for harmonic imaging modes. CONCLUSION: This relationship between signal intensity and decay rate and acoustic power output suggests that transient scattering related to bubble destruction is responsible for generation of the power Doppler signal in the absence of flow. This would explain the enhanced detection of the very low velocity flows in the myocardial capillaries by power Doppler contrast imaging.

Blood Flow Velocity↗

Triplet pregnancy after intracytoplasmic sperm injection of cryopreserved oocytes: case report.

OBJECTIVE: To report a triplet pregnancy that occurred after intracytoplasmic injection of sperm into cryopreserved oocytes. DESIGN: Case report. SETTING: Instituto de Ginecología y Fertilidad (IFER), Buenos Aires, Argentina. PATIENT: A 36-year-old infertile patient with premature ovarian failure and a previous term pregnancy with fresh donated oocytes. INTERVENTION(S): We administered leuprolide acetate for pituitary down-regulation followed by E2 valerianate in incremental doses until an endometrial lining of >8 mm was observed by ultrasound. Thawing of frozen donated oocytes, intracytoplasmic sperm injection (ICSI), and translaparoscopic fallopian tube ET also were performed. Natural micronized progesterone was administered intravaginally (600 mg/d) before ET. MAIN OUTCOME MEASURE(S): Ultrasound at the 8th week of gestation revealed a triplet pregnancy with active fetal heartbeats. RESULT(S): A triple intrauterine gestation was achieved with the use of microinjection into cryopreserved oocytes. CONCLUSION(S): This case illustrates the feasibility of oocyte cryopreservation for clinical use in the era of ICSI.

Adult↗

Severe fetal malformations associated with trisomy 16 confined to the placenta.

Chorionic villus sampling (CVS) and amniocentesis were performed on a pregnant woman during her 24th week of amenorrhoea following an ultrasound scan which showed a fetus with hydrocephaly, intrauterine growth retardation (IUGR), and a single umbilical artery. The direct karyotype from the cytotrophoblast was non-mosaic 47,XXX,+16, while in amniotic fluid and several fetal tissues, studied post-mortem, a normal 46,XX karyotype was found in more than 400 cells. Uniparental disomy (UPD) was excluded by molecular genetic studies. Autopsy confirmed the echographic findings; in addition, agenesis of the corpus callosum and polysplenia were observed. This is the second example of congenital abnormality associated with confined placental mosaicism (CPM) for trisomy 16, without evidence of either UPD or an apparent contribution of abnormal cells to the fetus.

Adult↗

Identification of right atrial thrombi using transoesophageal echocardiography.

The in vivo diagnosis of right atrial thrombus is difficult by transthoracic echocardiography and it is likely that small thrombi are underdiagnosed using this approach. Transoesophageal echocardiography provides an unobstructed view of cardiac structures and the great vessels. In this report we describe the findings in five patients with right atrial thrombi that illustrate the potential usefulness of transoesophageal echocardiography for both the initial diagnosis and the subsequent management of these patients.

Adult↗

Profiles of coronary blood flow velocity in patients with aortic stenosis and the effect of valve replacement: a transthoracic echocardiographic study.

OBJECTIVE: To report the first non-invasive assessment by transthoracic Doppler echocardiography of coronary blood flow in patients with aortic stenosis and of the effects of valve replacement. DESIGN: High frequency transthoracic Doppler echocardiography was used to examine resting phasic flow in the left anterior descending coronary artery before and after replacement of the aortic valve in awake, unsedated patients with pure aortic stenosis and normal coronary arteries. SETTING: A tertiary referral cardiothoracic centre. METHODS: Eleven patients with pure aortic stenosis and normal coronary arteries (six men, five women, mean (range) age 69 (50-82) years), were studied the day before and 1 week after replacement of the aortic valve. These patients were selected from a cohort of 15 due to ease of imaging of the left anterior descending coronary artery. Seven had a history of angina. Haemodynamics, peak transvalvar aortic gradient, left ventricular mass index, ventricular dimensions, and profiles of coronary flow velocity were measured. Profiles of coronary flow velocity were also measured in a control population of 10 normal subjects (five men, five women, mean (range) age 58 (34-66) years). RESULTS: The control population showed forward flow throughout systole, but reversed early systolic flow (mean velocity 20.6 (3.6) cm/s) was seen in six patients with aortic stenosis. Only three of these patients had a clinical history of angina. Peak and mean systolic and diastolic forward flow velocities were not significantly different in the control group and in patients with aortic stenosis. The time from the start of systole to the onset of forward systolic flow was significantly longer in patients with aortic stenosis than in the control population (185 (8.5) v 85 (10) ms, p < 0.01). The time from the onset of diastolic flow to peak diastolic velocity was also significantly longer in the aortic stenosis group (146 (16) v 74 (13) ms, p < 0.01). These abnormalities in profiles of coronary flow were reversed by replacement of the aortic valve. There was no correlation between changes in flow profiles in patients with aortic stenosis and preoperative clinical history, transvalvar gradient, left ventricular mass index, or ventricular dimensions. CONCLUSIONS: Coronary flow profiles in patients with aortic stenosis were characterised by reversed early systolic flow and delayed forward systolic flow and attainment of peak diastolic velocity. Reversal of these abnormalities by replacement of the aortic valve may reflect altered left ventricular and aortic haemodynamics and contribute to the relief of angina when left ventricular hypertrophy persists. Further studies may correlate abnormalities of coronary flow with preoperative clinical and haemodynamic state.

Aged↗

Identification of coronary artery stenoses and poststenotic blood flow patterns using a miniature high-frequency epicardial transducer.

BACKGROUND: Intraoperative epicardial coronary Doppler ultrasound has the potential to provide anatomic and functional information. This technique has been hindered by the large size of standard transducers, but a miniature transducer is available that may fulfill the potential of coronary ultrasound. METHODS AND RESULTS: Twenty consecutive patients who were undergoing coronary artery bypass grafting were studied and compared with 9 control patients with normal coronary arteries who were undergoing routine mitral valve surgery. A miniature 6.5-MHz transducer was used to image coronary arteries and measure coronary blood flow velocities. Seventeen proximal left anterior descending and 3 right coronary artery stenoses were studied. As defined by coronary angiography (1 to 34 days before surgery), there were 13 severe stenoses (> 70%), 4 moderate stenoses (40% to 70%), 2 minor stenoses (< 40%), and 1 subtotal occlusion. Stenoses were readily identified by ultrasound. Color flow mapping demonstrated laminar flow in normal arteries and nonlaminar flow across moderate and severe stenoses. In the control patients with unobstructed arteries, peak and mean diastolic velocities were 35 +/- 2.1 and 26 +/- 1.9 cm/s with peak and mean systolic velocities of 16 +/- 1.4 and 11 +/- 0.8 cm/s, respectively. Prestenotic flow velocities were not significantly different from normal control values, but a wide range of poststenotic flow disturbances were detected. Analysis of the 20 study patients did not reveal significant differences in poststenotic compared with prestenotic flow. A subgroup analysis of 12 patients with severe left anterior descending coronary artery stenoses was performed, and reversed poststenotic systolic flow was seen in 9. Prestenotic peak and mean systolic velocities were 16.5 +/- 1.7 and 11.9 +/- 1.1 cm/s, respectively, and were significantly altered downstream of the stenoses at -22.7 +/- 17.2 and -15.9 +/- 10.9 cm/s (P < .05 and P < .01, respectively). Reversed systolic flow was seen only distal to severe left anterior descending coronary artery stenoses and did not correlate with retrograde collateral filling as determined by preoperative coronary angiography. Moderate stenoses appeared to increase both systolic and diastolic components of poststenotic flow. CONCLUSIONS: Epicardial Doppler ultrasound with a miniature transducer identifies coronary stenoses and associated blood flow disturbances. Compared with moderate lesions, severe stenoses demonstrated different poststenotic flow patterns. Intraoperative use of this technique may determine the hemodynamic significance of coronary stenoses.

Adult↗

Acute coronary embolism complicating aortic valve endocarditis treated with streptokinase and aspirin. A case report.

Bacterial endocarditis may present with acute chest pain due to coronary embolization and mimics acute myocardial infarction secondary to coronary atherosclerosis. We present the first case report of coronary embolization secondary to aortic valve endocarditis treated with standard doses of streptokinase and aspirin. The patient survived but sustained a large myocardial infarction and a major gastrointestinal bleed. Infective endocarditis should be considered in all patients presenting with acute chest pain. When myocardial infarction is due to coronary embolism from endocarditic valves standard thrombolysis regimes should be avoided.

Aortic Valve↗

Transthoracic high-frequency two-dimensional echocardiography, Doppler and color flow mapping to determine anatomy and blood flow patterns in the distal left anterior descending coronary artery.

Combined high-frequency transthoracic ultrasound, pulsed Doppler and color flow mapping were used to image and assess blood flow velocity in the distal left anterior descending artery (LAD) in 56 consecutive patients. All patients subsequently underwent coronary angiography. The LAD was imaged in 19 patients (34%), and the diameter was measured in 12 with high-quality images (mean diameter 1.8 mm +/- 0.08). In 1 patient, the penetrating branches of the LAD were imaged. The distal LAD appeared normal by ultrasound in 18 patients, and a significant stenosis was detected in 1; angiography confirmed the ultrasound findings. There were no false negative results. Characteristic biphasic flow with higher velocities in diastole were noted in all 19 patients. Color flow mapping demonstrated normal laminar flow, except in the patient with a distal stenosis. Pulsed Doppler confirmed an increased velocity distal to the stenosis in this patient. This study is the first transthoracic evaluation of the hemodynamic effects of a coronary artery stenosis, and the first in vivo description of blood flow disturbance at a distal coronary stenosis in humans. The clinical use of this technique is limited, because only the distal portion of the LAD is visualized. However, it may provide a noninvasive means of assessing distal LAD diameter and blood flow, and changes in these parameters under a variety of physiologic, pharmacologic and interventional stimuli.

Adolescent↗