Search PubMed⌕ Search

Biomedical subjects

A Johnston

Publications and source records attributed to A Johnston.

At least 55 records · Page 3Linked to original sources

Limited sampling strategies for estimating cyclosporin area under the concentration-time curve: review of current algorithms.

Cyclosporin, the drug of first choice in transplantation surgery, is characterized by a low therapeutic index and variable absorption, so close monitoring of the drug is required to optimize the dosing. Predose blood cyclosporin levels are measured routinely for therapeutic monitoring, but this approach is not optimal because the area under the concentration-time curve (AUC) correlates better with clinical events. However, conventional methods of measuring AUC require many blood samples, which is not viable in a routine clinical setting. AUC monitoring can be simplified for use in a clinical setting by using a limited sampling strategy (LSS) that allows AUC to be estimated using a small number of blood samples collected at specific times. This article reviews the current literature on estimating cyclosporin AUC using LSS. Thirty-eight papers suggesting the use of specific time points were found. LSS has been developed for different transplant types, with different dosing regimens, and with different assays. Most authors suggested either two- or three-sample equations. Results from authors who validated their models suggest that equations defined on one transplant type may be applicable to other transplant types, to both adults and children, and to early or late after transplantation. Moreover, it seems that there is flexibility in the choice of equations available to clinicians. The number of samples to collect for accurate estimations is a matter of debate, but a wise choice can minimize the number. The choice of the optimal LSS and validation are discussed.

Algorithms↗

Congenital adrenal hyperplasia: management during critical illness.

BACKGROUND: Little is known of the optimal dose and administration schedule of hydrocortisone in critically ill patients with congenital adrenal hyperplasia (CAH) caused by 21-hydroxylase deficiency. AIM: To determine plasma cortisol concentrations after intravenous administration of hydrocortisone in children with CAH and to relate these to plasma cortisol concentrations achieved by endogenous secretion in the stress of critical illness in previously healthy children. METHODS: Plasma cortisol concentrations were measured in 20 patients with classical CAH (median age 11.2 years, range 6.1-16.4) following intravenous administration of hydrocortisone 15 mg/m(2); and in 60 critically ill mechanically ventilated children (median age 2.5 years, range 0.25-16.3) on admission to the paediatric intensive care unit and for 24 hours thereafter. RESULTS: In the CAH patients, plasma cortisol reached a mean peak of 1648.3 nmol/l (SD 511.9) within 10 minutes of the intravenous bolus, and fell rapidly thereafter; levels remained greater than 450 nmol/l for 2.5 hours only. In critically ill children, mean plasma cortisol on admission to the intensive care unit was 727 nmol/l (SD 426.1). Cortisol concentrations remained raised during the first 24 hours. CONCLUSIONS: Critically ill patients with classical CAH may be best managed with a single intravenous hydrocortisone bolus followed by a constant rate infusion of hydrocortisone.

Adolescent↗

Serum cortisol and 17-hydroxyprogesterone interrelation in classic 21-hydroxylase deficiency: is current replacement therapy satisfactory?

One of the main aims in the management of patients with congenital adrenal hyperplasia due to 21-hydroxylase deficiency is to achieve adequate suppression of the adrenal cortex with the smallest possible dose of glucocorticoid substitution. To evaluate the administration schedule of current replacement therapy regimens, we investigated the cortisol-17-hydroxyprogesterone interrelation in 36 patients (13 males and 23 females; median age, 12.3 yr; range, 6.1-18.8 yr) with salt-wasting congenital adrenal hyperplasia. As sufficient variation in 17-hydroxyprogesterone concentrations was required to allow analysis of the cortisol-17-hydroxyprogesterone interrelation, patients were divided into 2 groups depending on the adequacy of hypothalamic-pituitary-adrenal axis suppression. The first group consisted of 17 patients with suppressed 17-hydroxyprogesterone concentrations (group 1), and the second group consisted of 19 patients with nonsuppressed 17-hydroxyprogesterone concentrations (group 2). We determined serum cortisol and 17-hydroxyprogesterone concentrations at 20-min intervals for a total of 24 h while patients were receiving their usual replacement treatment with hydrocortisone and 9alpha-fludrocortisone. We also determined the lowest dose of dexamethasone required to suppress the 0800 h serum ACTH concentrations when administered as a single dose (0.3 or 0.5 mg/m(2)) the night before. Mean 24-h cortisol and 17-hydroxyprogesterone concentrations were 3.9 microg/dl (SD = 2.1) and 66.2 ng/dl (SD = 92.7), respectively, in group 1 and 4.1 microg/dl (SD = 2.5) and 4865.7 ng/dl (SD = 6951) in group 2. The 24-h 17-hydroxyprogesterone concentrations demonstrated circadian variation, with peak values observed between 0400-0900 h. In group 2, 17-hydroxyprogesterone concentrations decreased gradually in response to the rise in cortisol concentrations during the day, but remained low during the night despite the almost undetectable cortisol concentrations between 1600-2000 h. Mean 0800 h androstenedione concentrations correlated strongly with integrated 17-hydroxyprogesterone concentrations (r = 0.81; P < 0.0001), but not with integrated cortisol concentrations. There was a significant negative correlation between cortisol and 17-hydroxyprogesterone at lag time 0 min (r = -0.187; P < 0.0001), peaking at lag time 60 min (r = -0.302; P < 0.0001), with cortisol leading 17-hydroxyprogesterone by these time intervals. Finally, 0800 h serum ACTH concentrations were sufficiently suppressed after a dexamethasone dose of 0.3 mg/m(2) in all but three patients. These findings indicate that in classic 21-hydroxylase deficiency, hydrocortisone should be administered during the period of increased hypothalamic-pituitary-adrenal axis activity, between 0400-1600 h, with the biggest dose given in the morning. Blood investigations performed as part of monitoring of congenital adrenal hyperplasia patients should include androstenedione and 17-hydroxyprogesterone concentrations determined in the morning before the administration of hydrocortisone. It should also be emphasized that blood investigations are only complementary to the overall assessment of these patients, which is primarily based on the evaluation of growth and pubertal progress.

17-alpha-Hydroxyprogesterone↗

Congenital adrenal hyperplasia due to 21-hydroxylase deficiency: alterations in cortisol pharmacokinetics at puberty.

In congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency, treatment with glucocorticoid and mineralocorticoid substitution is not always satisfactory. Suboptimal control is often observed in pubertal patients, despite adequate replacement doses and adherence to treatment. We investigated whether the pubertal process is associated with alterations in cortisol pharmacokinetics resulting in a loss of control of the hypothalamic-pituitary-adrenal axis. We determined the pharmacokinetics of hydrocortisone administered iv as a bolus. A dose of 15 mg/m(2) body surface area was given to 14 prepubertal (median age, 9.4 yr; range, 6.1--10.8 yr), 20 pubertal (median, 13.5 yr; range, 10.6--16.8 yr), and 6 postpubertal (median, 18.2 yr; range, 17.2--20.3 yr) patients with salt-wasting CAH. All patients were on standard replacement therapy with hydrocortisone and 9 alpha-fludrocortisone. Serum total cortisol concentrations were measured at 10-min intervals for 6 h following iv hydrocortisone bolus and analyzed using a solid-phase RIA. The serum total cortisol clearance curve was monoexponential. Mean clearance was significantly higher in the pubertal group (mean, 427.0 mL/min; SD, 133.4) compared with the prepubertal (mean, 248.7 mL/min; SD, 100.6) and postpubertal (mean, 292.4 mL/min; SD, 106.3) (one-way ANOVA, F = 9.8, P < 0.001) groups. This effect persisted after adjustment for body mass index. The mean volume of distribution was also significantly higher in the pubertal (mean, 49.5 L; SD, 12.2) than the prepubertal (mean, 27.1 L; SD, 8.4) patients but not in the postpubertal (mean, 40.8 L; SD, 16) (ANOVA, F = 15.2, P < 0.001) patients. The significance remained after correction for body mass index. There was no significant difference in mean half-life of total cortisol in prepubertal (mean, 80.2 min; SD, 19.4), pubertal (mean, 84.4 min; SD, 24.9), and postpubertal (mean, 96.7 min; SD, 9.9) patients. Similar differences between groups were observed when the pharmacokinetic parameters of free cortisol were examined. In addition, the half-life of free cortisol was significantly shorter in females compared with males (P = 0.04). These data suggest that puberty is associated with alterations in cortisol pharmacokinetics resulting in increased clearance and volume of distribution with no change in half-life. These alterations probably reflect changes in the endocrine milieu at puberty and may have implications for therapy of CAH and other conditions requiring cortisol substitution in the adolescent years.

Adolescent↗

Computational modeling of non-Fourier motion: further evidence for a single luminance-based mechanism.

It is generally assumed that the perception of non-Fourier motion requires the operation of some nonlinearity before motion analysis. We apply a computational model of biological motion processing to a class of non-Fourier motion stimuli designed to investigate nonlinearity in human visual processing. The model correctly detects direction of motion in these non-Fourier stimuli without recourse to any preprocessing nonlinearity. This demonstrates that the non-Fourier motion in some non-Fourier stimuli is directly available to luminance-based motion mechanisms operating on measurements of local spatial and temporal gradients.

Fourier Analysis↗

Motion of contrast envelopes: peace and noise.

We examined the effect of changing the composition of the carrier on the perception of motion in a drifting contrast envelope. Human observers were required to discriminate the direction of motion of contrast modulations of an underlying carrier as a function of temporal frequency and scaled (carrier) contrast. The carriers were modulations of both color and luminance, defined within a cardinal color space. Random-noise carriers had either binary luminance profiles or flat (gray-scale-white) or 1/f (pink) spectral power functions. Independent variables investigated were the envelope spatial frequency and temporal-drift frequency and the fundamental spatial frequency, color, and temporal-update frequency of the carrier. The results show that observers were able to discriminate correctly the direction of envelope motion for binary-noise carriers at both high (16 Hz) and low (2 Hz) temporal-drift frequencies. Changing the carrier format from binary noise to a flat (gray-scale) or 1/f amplitude profile reduced discrimination performance slightly but only in the high-temporal-frequency condition. Manipulation of the fundamental frequency of the carrier elicited no change in performance at the low temporal frequencies but produced ambiguous or reversed motion at the higher temporal frequencies as soon as the fundamental frequency was higher than the envelope modulation frequency. We found that envelope motion detection was sensitive to the structure of the carrier.

Color↗

Bioavailability of oral hydrocortisone in patients with congenital adrenal hyperplasia due to 21-hydroxylase deficiency.

The management of congenital adrenal hyperplasia due to 21-hydroxylase (CYP21) deficiency requires glucocorticoid substitution with oral hydrocortisone given twice or thrice daily. In paediatric practice little is known of the bioavailability of oral hydrocortisone tablets used in these patients. The aim of this study was to assess the bioavailability of oral hydrocortisone and to evaluate current replacement therapy in the light of cortisol pharmacokinetic properties. We determined the bioavailability of hydrocortisone following oral and intravenous administration in sixteen (median age: 10.9 years, range: 6.0-18.4 years) adequately controlled CYP21 deficient patients. Serum total cortisol concentrations were measured at 20-min intervals for 24 h while patients were on oral substitution therapy, and at 10-min intervals for 6 h following an intravenous bolus of hydrocortisone in a dose of 15 mg/m(2) body surface area. The area under the serum total cortisol concentration versus time curve (AUC) following oral and intravenous administration of hydrocortisone was calculated using the trapezoid method. The bioavailability was estimated by dividing the corrected for dose AUC after oral hydrocortisone administration by the corrected for dose AUC after the intravenous hydrocortisone administration and was exemplified as a percentage. After oral administration of hydrocortisone in the morning, median serum total cortisol concentrations reached a peak of 729.5 nmol/l (range: 492-2520 nmol/l) at 1.2 h (range: 0.3-3.3 h) and declined monoexponentially thereafter to reach undetectable concentrations 7 h (range: 5-12 h) after administration. Following administration of the evening hydrocortisone dose, median peak cortisol concentration of 499 nmol/l (range: 333-736 nmol/l) was attained also at 1.2 h (range: 0.3-3.0 h) and subsequently declined gradually, reaching undetectable concentrations at 9 h (5-12 h) after administration of the oral dose. After the intravenous hydrocortisone bolus a median peak serum total cortisol concentration of 1930 nmol/l (range: 1124-2700 nmol/l) was observed at 10 min (range: 10-20 min). Serum cortisol concentrations fell rapidly and reached undetectable levels 6 h after the hydrocortisone bolus. The absolute bioavailability of oral hydrocortisone in the morning was 94.2% (90% confidence interval (CI): 82.8-105.5%) whereas the apparent bioavailability in the evening was estimated to be 128.0% (90% CI: 119.0-138.0%). We conclude that the bioavailability of oral hydrocortisone is high and may result in supraphysiological cortisol concentrations within 1-2 h after administration of high doses. The even higher bioavailability in the evening, estimated using as reference the data derived from the intravenous administration of hydrocortisone bolus in the morning, is likely to reflect a decrease in the hydrocortisone clearance in the evening. Decisions on the schedule and frequency of administration in patients with congenital adrenal hyperplasia should be based on the knowledge of the bioavailability and other pharmacokinetic parameters of the hydrocortisone formulations currently available.

Administration, Oral↗

A novel method for the delivery of nitric oxide therapy to the skin of human subjects using a semi-permeable membrane.

Nitric oxide (NO) is a mediator of essential biological processes, including vasodilatation, anti-microbial activity and wound healing. A chemical system using sodium nitrite and ascorbic acid has been developed which generates significant amounts of NO. The originally described system was messy and impractical, and the high acidity may cause pain and further tissue damage in ulcerated skin. To overcome this, a selectively permeable, hydrophilic polyester co-polymer membrane system (Sympatex ) has been identified that can be placed between the NO-generating chemicals and the skin. The aim of the present study was to determine whether NO derived from this chemical system was able to diffuse through the membrane and have a measurable vasodilatory effect on forearm skin in healthy volunteers. The Sympatex 10 microm membrane was found to be highly permeable to NO, while preventing passage of the constituents of the NO-generation gel to the skin. The transmembrane NO-generation system had a vasodilatory effect comparable with that resulting from direct topical application. Additionally, the NO generated was effective in killing Staphylococcus aureus and Escherichia coli at doses lower than those required to increase skin blood flow. The vasodilatory and anti-microbial effects of this system may be useful as a patch-based topical therapy for skin ulceration, particularly when there is concomitant ischaemia and infection.

Administration, Cutaneous↗

Inactivation and clearance of viruses during the manufacture of high purity factor IX.

Haemophilia is a bleeding disorder characterised by a deficiency in Factor IX. Replacement therapy in the form of a Factor IX concentrate is a widely accepted practice. In this paper we describe a double virus inactivated chromatographic process for producing a high purity Factor IX product, MonoFIX((R))-VF. The process involves separation of the prothrombin complex by cryoprecipitation, fraction I precipitation and DEAE-cellulose adsorption, further ion-exchange chromatography of crude Factor IX, followed by solvent/detergent treatment. Heparin affinity chromatography is then used to further purify Factor IX. Final nanofiltration is sequential through 35 nm then 15 nm membrane filters. The principal virus inactivation/removal steps are solvent/detergent treatment and nanofiltration and the partitioning of relevant and model viruses provides further reduction in virus load through the production process.Solvent/detergent treatment was shown to achieve log reduction factors of 4.5 for HIV-1, 5.1 for Sindbis virus, 6.1 for vesicular stomatitis virus (VSV), 5.1 for bovine viral diarrhoea virus (BVDV) and 5.3 for pseudorabies virus (PRV). BVDV is a model for hepatitis C virus (HCV), and pseudorabies virus (PRV), like hepatitis B virus (HBV) is an enveloped DNA virus. Using scaled down models of the production process, we have also demonstrated the neutralization/partitioning of at least 6 logs of hepatitis A virus (HAV) during cryoprecipitation, Fraction I precipitation, and the DEAE adsorption and elution step, and a further 1.6 log reduction in HAV load as a result of heparin affinity chromatography. The log reduction factors for HAV as a result of the second ion-exchange chromatography step and as a result of enhanced neutralisation associated with solvent/detergent treatment were not significant. Nanofiltration was shown to contribute a further log reduction factor of 6.7 for HAV and 5.8 for BVDV indicating that log reduction factors of this order would be obtained with other viruses of a similar or larger size, such as HIV, HBV and HCV.Overall, these studies indicate that MonoFIX-VF is a product with an extremely high level of viral safety.

Animals↗

Computational modelling of interleaved first- and second-order motion sequences and translating 3f+4f beat patterns.

Despite detailed psychophysical, neurophysiological and electrophysiological investigation, the number and nature of independent and parallel motion processing mechanisms in the visual cortex remains controversial. Here we use computational modelling to evaluate evidence from two psychophysical studies collectively thought to demonstrate the existence of three separate and independent motion processing channels. We show that the pattern of psychophysical results can largely be accounted for by a single mechanism. The results demonstrate that a low-level luminance based approach can potentially provide a wider account of human motion processing than generally thought possible.

Humans↗

Measurement of sirolimus in whole blood using high-performance liquid chromatography with ultraviolet detection.

BACKGROUND: Sirolimus, a potent immunosuppressive drug, exhibits intrapatient and interpatient variability of absorption and metabolism. Thus, therapeutic drug monitoring is important. OBJECTIVE: This paper describes a reverse-phase high-performance liquid chromatography (HPLC) method, using ultraviolet (UV) absorption for detection, for measuring sirolimus levels in human whole-blood samples. METHODS: The stability of sirolimus in whole blood was assessed under conditions likely to be encountered during transport of study samples to a central laboratory. The performance of the HPLC-UV assay in measuring sirolimus was compared with that of 3 established, validated HPLC assays with tandem mass-spectrometric (MS/MS) detection. Results of the HPLC-UV assay also were compared with results produced by a prototype microparticle enzyme immunoassay (MEIA). RESULTS: Inaccuracy for 3 in-house control samples was < or =4%, whereas within-assay repeatability (coefficient of variation [CV]) was < or =5% and between-assay reproducibility was < or =6.6%. Mean recovery of sirolimus from blood was 81.5%+/-4.3%. The lower limit of quantification was set at 6.5 ng/mL, and the repeatability CV at this concentration was 4.2% (n = 6). Sirolimus-containing whole-blood samples were stable for 3 freeze/thaw cycles when stored at -20 degrees C and for > or =2 days when stored at ambient temperature. The sample extract was shown to be stable for up to 54 hours at ambient temperature (approximately 22 degrees C) after extraction. Results of the HPLC-UV assay were consistent with those of the HPLC/ MS/MS assays but lower than those produced by MEIA. CONCLUSION: This HPLC-UV method is considered suitable for therapeutic drug monitoring of sirolimus.

Calibration↗

An immunoassay for the measurement of sirolimus.

OBJECTIVE: This study assessed the performance characteristics of a new microparticle enzyme immunoassay (MEIA) for the determination of sirolimus in whole blood. BACKGROUND: In clinical investigatory studies, dose adjustments of the immunosuppressive drug sirolimus have been carried out using either high-performance liquid chromatography (HPLC) or, more recently, this investigational immunoassay kit based on the MEIA technique. METHODS: Calibration was made over the linear range 0 to 30 ng/mL. Inaccuracy and imprecision were assessed by means of 3 control samples supplied with the kit (5, 11, and 22 ng/mL) and dilution of an above-quantitation-limit sample (154 ng/mL). Specificity was determined by the addition of 2 sirolimus metabolites to sirolimus-free human whole blood or to I of the control samples supplied with the kit. In addition, whole-blood samples from patients receiving either cyclosporine or tacrolimus (N = 24) were analyzed for sirolimus. A comparison of the MEIA and a validated HPLC/MS/MS assay analyzed both pooled samples from patients receiving sirolimus and spiked samples (sirolimus 2-60 ng/mL). In a more extensive comparison of patient samples measured by the MEIA assay, a validated HPLC assay with UV detection (HPLC-UV) was used (HPLC-UV sirolimus 7-64 ng/mL). RESULTS: Inaccuracy (between-run) was < or =16.2% at all 4 concentrations (N = 5). Within-assay imprecision (repeatability) was <6% (N = 5), and between-assay imprecision (reproducibility) for the same samples was < 11% (N = 5). Recovery, assessed by means of 3 in-house control samples prepared in both fresh and previously frozen sirolimus-free human whole blood, ranged from 93.9% to 109.5%. The limit of detection, determined by dilution of the lowest nonzero calibrator (3 ng/mL), was set at 1 ng/mL, at which repeatability was 20.5% (N = 5). Five ng/mL of hydroxysirolimus cross-reacted with the assay by a mean of between 44% and 50% (N = 4); 5 ng/mL of 41-O-demethylsirolimus cross-reacted with the assay by a mean of between 86% and 127% (N = 4). Assay specificity was further challenged by ethylenediamine-tetraacetic acid (EDTA)-whole-blood samples from transplant patients not receiving sirolimus. These samples had tacrolimus and cyclosporine concentrations of 7.8 to 15.9 ng/mL and 38 to 485 microg/L, respectively. The median result was 0 ng/mL (third quartile, 0.7 ng/mL; maximum, 1.4 ng/mL); no value was above the lowest nonzero calibrator. The results of the comparison between the MEIA and the HPLC/MS/MS assay showed mean positive biases of 21% and 8% for the MEIA in measuring sirolimus in pooled patient samples and spiked samples, respectively. The results of the comparison of the MEIA and HPLC-UV median sirolimus concentrations were 18.2 and 20.1. Whole-blood samples anticoagulated with EDTA and containing sirolimus were stable for analysis by MEIA for 3 freeze-thaw cycles when stored at -20 degrees C and for 10 days when stored at 4 degrees C or at ambient temperature. A decline in sirolimus concentration occurred when samples were stored at 37 degrees C. CONCLUSION: The MEIA showed suitable precision across a clinically relevant concentration range. In terms of patient management, the practical significance of cross-reactivity with sirolimus metabolites remains to be assessed.

Antibody Specificity↗

Proficiency-testing issues relating to sirolimus.

BACKGROUND: A need exists to document laboratory proficiency to (1) compare results produced by different analytical techniques and (2) ensure consistency of results from multiple testing sites. OBJECTIVES: To enable concentration-controlled studies of sirolimus to proceed with confidence, proficiency-testing schemes were put in place at laboratories selected to act as reference laboratories. The feasibility of establishing an ongoing proficiency-testing scheme was addressed with respect to sample stability. The scheme was then used to test proficiency for the measurement of sirolimus in 3 blinded samples each month. METHODS: The method chosen for measurement of sirolimus was a prototype microparticle enzyme immunoassay. Initially, 15 laboratories were asked to analyze a series of 85 blinded samples that tested their inaccuracy, repeatability, and reproducibility for the measurement and their ability to dilute over-range samples competently. Both blood samples spiked with sirolimus and pooled blood samples from patients receiving the drug were circulated to a maximum of 50 laboratories. RESULTS: Overall, both inaccuracy and imprecision were acceptable by predefined criteria. Inaccuracy for the immunoassay (percentage difference of the measured value against the nominal value) averaged -5% (95% CI, -9% to -1%). The mean percentage difference between the immunoassay and a high-performance liquid chromatographic assay with mass-spectrometric detection for the measurement of sirolimus in pooled samples (n = 5) from patients receiving the drug was 29% (95% CI, 24% to 34%). CONCLUSION: The techniques documented here as part of the International Sirolimus Proficiency Testing Scheme could be applied to other clinical studies requiring protocol-driven dosing adjustments based on sirolimus measurements, irrespective of analytical technique used.

Chromatography, High Pressure Liquid↗

Pharmacokinetics of mycophenolate mofetil in patients with end-stage renal failure.

BACKGROUND: Mycophenolate mofetil (MMF) acts as a prodrug for the immunosuppressive drug mycophenolic acid (MPA). It is rapidly converted to MPA following oral ingestion. MPA is metabolized to MPA glucuronide (MPAG), which is renally excreted. This study examines the pharmacokinetics of MPA and MPAG in patients with end-stage renal failure who were on hemodialysis (N = 10) or peritoneal dialysis (N = 10) treatment. METHODS: After an overnight fast, a single oral dose of 1 g MMF was given. Plasma concentrations of MPA and MPAG were measured from 0 (predose) to 36 hours after administration, using high-performance liquid chromatography (HPLC). The area under the concentration time curve (AUC) from 0 to 36 hours was calculated using the trapezoidal rule. RESULTS: Mean (+/- SD) AUC for MPA was 55.7 +/- 32.6 mg/L.h for hemodialysis patients and 44.7 +/- 14.7 mg/L.h for peritoneal dialysis patients, which is similar to expected values for subjects with normal renal function. The mean (+/- SD) maximum plasma concentration (Cmax) for MPA was lower than would be expected for subjects with normal renal function (16.01 +/- 10.61 mg/L for hemodialysis, 11.48 +/- 4.98 mg/L for peritoneal dialysis). MPAG clearance was prolonged with AUC approximately five times what would be expected in subjects with normal renal function (1565 +/- 596 mg/L.h for hemodialysis, 1386 +/- 410 mg/L.h for peritoneal dialysis). There was no significant difference for any of the pharmacokinetic parameters between subjects on hemodialysis and those on peritoneal dialysis. Plasma concentrations of MPA and MPAG did not fall significantly during hemodialysis. No MPA was detectable in hemodialysis or peritoneal dialysis fluid, but small amounts of MPAG were detected in hemodialysis fluid in 1 out of 10 subjects and in peritoneal dialysis fluid in 3 out of 10 subjects. CONCLUSIONS: The accumulation of MPAG may be responsible for the poor gastrointestinal tolerance of this drug in dialysis patients and probably limits the maximum dose of MMF that can be tolerated.

Adult↗