Search PubMed⌕ Search

Biomedical subjects

A Jha

Publications and source records attributed to A Jha.

39 records · Page 3Linked to original sources

Improving response to critical laboratory results with automation: results of a randomized controlled trial.

OBJECTIVE: To evaluate the effect of an automatic alerting system on the time until treatment is ordered for patients with critical laboratory results. DESIGN: Prospective randomized controlled trial. INTERVENTION: A computer system to detect critical conditions and automatically notify the responsible physician via the hospital's paging system. PATIENTS: Medical and surgical inpatients at a large academic medical center. One two-month study period for each service. MAIN OUTCOMES: Interval from when a critical result was available for review until an appropriate treatment was ordered. Secondary outcomes were the time until the critical condition resolved and the frequency of adverse events. METHODS: The alerting system looked for 12 conditions involving laboratory results and medications. For intervention patients, the covering physician was automatically notified about the presence of the results. For control patients, no automatic notification was made. Chart review was performed to determine the outcomes. RESULTS: After exclusions, 192 alerting situations (94 interventions, 98 controls) were analyzed. The intervention group had a 38 percent shorter median time interval (1.0 hours vs. 1.6 hours, P = 0.003; mean, 4.1 vs. 4.6 hours, P = 0.003) until an appropriate treatment was ordered. The time until the alerting condition resolved was less in the intervention group (median, 8.4 hours vs. 8.9 hours, P = 0.11; mean, 14.4 hours vs. 20.2 hours, P = 0.11), although these results did not achieve statistical significance. The impact of the intervention was more pronounced for alerts that did not meet the laboratory's critical reporting criteria. There was no significant difference between the two groups in the number of adverse events. CONCLUSION: An automatic alerting system reduced the time until an appropriate treatment was ordered for patients who had critical laboratory results. Information technologies that facilitate the transmission of important patient data can potentially improve the quality of care.

Academic Medical Centers↗

Appropriateness of antiepileptic drug level monitoring.

OBJECTIVES: To develop explicit, reliable appropriateness criteria for antiepileptic drug level monitoring and to assess the appropriateness of monitoring in one tertiary care institution. DESIGN: Appropriateness criteria derived from the literature and through expert opinion were used to evaluate a stratified random sample of antiepileptic drug level determinations obtained from chart review. SETTING: Tertiary care center performing more than 10,000 antiepileptic drug level determinations per year. PATIENTS: A total of 330 inpatients in whom antiepileptic drug levels were measured a total of 855 times. METHODS: Drug levels were assessed at least 200 times for each of four antiepileptic drugs (phenytoin, carbamazepine, phenobarbital, and valproic acid). MAIN OUTCOME MEASURES: The proportion of antiepileptic drug levels with an appropriate indication and, of those, the proportion sampled appropriately. RESULTS: Overall, 27% (95% confidence interval, 24% to 30%) of levels had an appropriate indication. Interrater agreement for appropriateness was substantial (kappa = 0.61). There was no significant difference in the appropriateness rate among the four drugs (range, 25% to 29%). Of the 624 antiepileptic drug level determinations considered inappropriate (73%), only four (0.6%) were more than 20% higher than the upper limit of normal, and none of the four patients had clinical signs of drug toxicity. A median of six levels (range, one through 69) was determined per patient, and the median interval between level determinations was 24 hours. Of the 27% of level determinations with an appropriate indication, 51% were sampled correctly, resulting in an overall appropriateness rate of 14%. CONCLUSIONS: Only 27% of antiepileptic drug level determinations had an appropriate indication, and half of these were not sampled correctly. Routine daily monitoring without pharmacological justification accounted for most of the inappropriate drug level determinations. Efforts to decrease inappropriate monitoring may result in substantial cost reductions without missing important clinical results.

Adolescent↗