Search PubMed⌕ Search

Biomedical subjects

A J Labovitz

Publications and source records attributed to A J Labovitz.

At least 37 records · Page 2Linked to original sources

Prosthetic valves for the small aortic root.

Mechanical aortic valves (AVs) are frequently implanted in small (19 and 21 mm) aortic roots because bioprosthetic valves have unacceptably high gradients and many surgeons do not implant allograft valves. Three mechanical valves in common use today in the United States are the Starr-Edwards (SE), St. Jude Medical (SJ), and the Medtronic-Hall (MH). Clinical hemodynamic studies reveal that the 21-mm SE valve (size 8A) has peak systolic gradients of 13 to 58 mmHg (N = 6) with a calculated effective orifice of 0.7 to 1.4 cm2. The 19-mm SJ valve has a gradient at peak pressure of 17 mmHg and a mean gradient of 22 mmHg (N = 6) with respective exercise gradients of 32 and 38 mmHg (N = 5). For the 21-mm SJ valve the mean gradient was 5.2 +/- 5.3 (N +/- 12) and the gradient at peak pressure was 6.0 mmHg (N = 15). The 21-mm MH valve had resting gradients at peak pressure of 10.5 (N = 3) and 12.4 mmHg (N = 9) and exercise gradients of 15.8 mmHg (N = 9). Six months after AV replacement with small SJ or MH (N = 14) or large (23 mm or greater) (N = 83) valves, cardiac output was 4.7 versus 6.4 L/min (p < 0.03), percent reduction in left ventricular mass index (LVMI) was -8% versus -21% (p < 0.01), exercise duration was 370 versus 555 seconds, and congestive heart failure (CHF) class was 1.9 versus 1.1 (p < 0.0001). Change in LVMI and valve size were the only independent predictors of CHF class.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve↗

Usefulness of transesophageal echocardiography in unexplained cerebral ischemia.

Two-hundred seventy consecutive patients with "unexplained cerebral ischemia" were studied with transesophageal echocardiography to determine the value of this test in identifying potential cardiac sources of cerebral embolism. The findings of this group were compared with those of 772 consecutive patients undergoing transesophageal echocardiographic evaluation for indications other than cerebral ischemia. This study also examined this group of patients with unexplained cerebral ischemia to determine differences in relation to underlying cardiac rhythm and patient age. Intracardiac thrombus, atrial septal aneurysm, patent foramen ovale, spontaneous left atrial contrast and protruding debris in the thoracic aorta were found more often in patients with unexplained cerebral ischemia. Wall motion abnormalities of the left ventricle, as well as mild to moderate valvular lesions including mitral valve prolapse, were found to be similar in both groups. Spontaneous left atrial contrast, as well as mild to moderate valvular abnormalities, were found more often in patients with atrial fibrillation (22% of the group with unexplained cerebral ischemia). However, the presence of intracardiac thrombus was no more frequent in patients with atrial fibrillation than in those with normal sinus rhythm. Patients aged > 50 years were found to have atrial fibrillation and larger left atrial size more often than their younger cohorts, as well as a greater incidence of valvular abnormalities and left ventricular wall motion abnormalities. Mitral valve prolapse was seen more frequently in the younger cohort of patients.

Adolescent↗

Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the Phase III Albunex Multicenter Trial.

OBJECTIVES: This study was designed to assess the safety and efficacy of intravenously administered sonicated human serum albumin for enhancing echocardiographic delineation of the left ventricular endocardium and improving assessment of wall motion in patients with incomplete depiction of noncontrast echocardiography. BACKGROUND: Echocardiographic regional wall motion analysis is impaired by incomplete endocardial definition in as many as 10% of patients. Sonicated human serum albumin is a stable contrast material that, unlike other agents, opacifies the left ventricle when administered intravenously. METHODS: One hundred seventy-five patients were enrolled at eight centers on the basis of incomplete echocardiographic endocardial depiction. Sonicated 5% human serum albumin, a stable preparation of air-filled microspheres (size range 1 to 10 microns), was administered intravenously in divided doses: 0.08 ml/kg body weight in all patients, followed by 0.14 and 0.08 ml/kg or a single dose of 0.22 ml/kg, depending on the result of the initial dose. Investigators and independent reviewers blinded to the protocol scored the echocardiograms for degree of left ventricular opacification and improvement of endocardial border depiction. RESULTS: Overall, 81% of patients had at least moderate left ventricular chamber opacification with at least one contrast dose, and endocardial definition was improved in 83%. In the subgroup with inadequate left ventricular opacification from the initial dose, a second, larger dose (0.22 ml/kg) improved endocardial depiction in 64%. No significant side effects occurred. CONCLUSIONS: In patients with incomplete echocardiographic endocardial definition, sonicated human serum albumin is a safe, effective contrast agent that, when administered intravenously, produces left ventricular chamber opacification, improves endocardial depiction and enhances regional wall motion analysis.

Adult↗

Coronary flow velocity dynamics in normal and diseased arteries.

Distal coronary flow velocity measurements were previously limited to open heart or experimental procedures. Unlike previous Doppler catheter techniques, a Doppler angioplasty flow wire permits flow velocity measurements in both the proximal and distal segments of normal and diseased coronary arteries. In order to determine the potential clinical application of the Doppler flow wire, we performed baseline and hyperemia flow velocity measurements in proximal and distal segments of 20 angiographically normal arteries (right coronary = 8; left circumflex = 7; left anterior descending = 5) and 29 significantly stenosed arteries. All 3 normal coronary arteries had a diastolic-predominant pattern in both proximal and distal segments; the right coronary artery showed significantly less diastolic predominance. The coronary vasodilator reserve was similar in all three normal coronary arteries, and in the proximal and distal arterial segments. Abnormal arteries had significantly lower coronary vasodilator reserve (normal vs abnormal, 2.3 +/- 0.8/1.6 +/- 0.7; p < 0.02). Normal arteries had preservation of velocity parameters in the distal segments; abnormal arteries had a significant decrease in distal velocity parameters. The proximal-to-distal velocity ratio was thus significantly higher in abnormal arteries (2.4 +/- 0.7 vs 1.1 +/- 0.2; p < 0.001). The coronary vasodilator reserve in proximal and distal arteries--in addition to the proximal to distal velocity ratio--may provide functional and hemodynamic data complementary to coronary angiography in the assessment of coronary artery stenosis.

Blood Flow Velocity↗

Assessment of angiographically intermediate coronary artery stenosis using the Doppler flowire.

Determination of the clinical and hemodynamic significance of coronary stenoses is often difficult and inexact. Angiography and coronary vasodilator reserve have been shown to be imperfect tools to determine the physiologic significance of coronary stenoses. Spectral flow velocity data, both proximal and distal to coronary stenoses, using an 0.018-in intracoronary Doppler-tipped angioplasty guidewire, were compared to translesional pressure gradients and angiography during cardiac catheterization. Patients were divided into 2 groups based on resting translesional gradients: Group 1 had gradients < 20 mm Hg and group 2 had gradients > or = 20 mm Hg. Proximal average peak velocity, diastolic velocity integral, and total velocity integral were statistically significantly lower in Group 1. The distal average peak velocity, and diastolic and total velocity integrals were all significantly (p < 0.01) decreased in patients with gradients > 20 mm Hg (group 2). The ratio of proximal-to-distal total flow velocity integral was also higher in group 2 patients (2.3 +/- 0.9) compared with group 1 (1.1 +/- 0.2; p < 0.001). There was a strong correlation between translesional pressure gradients and the ratios of the proximal-to-distal total flow velocity integrals (r = 0.8, p < 0.001) with a weaker relationship between quantitative angiography and pressure gradients (r = 0.6, p < 0.001). Angiography was a poor predictor of translesional gradients in angiographically intermediate stenoses (range 50-70%; r = 0.2, p = NS), while the flow velocity ratios continued to have a strong correlation (r = 0.8, p < 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Superior accuracy of anatomic positioning with echocardiographic- over fluoroscopic-guided endomyocardial biopsy.

To assess the superior anatomic positioning of echocardiographic-guided endomyocardial biopsy compared to traditional fluoroscopic-guided technique, these two modalities were compared in a blinded fashion during femoral sheath endomyocardial biopsy in 21 patients, 19 being evaluated after orthotopic cardiac transplantation. The simultaneous fluoroscopic and echocardiographic imaging indicated that traditional fluoroscopic positioning of the bioptome against the septum is inaccurate in over half of patients undergoing biopsy. This finding should be considered in cardiomyopathy patients or those at high risk for biopsy-related complications.

Biopsy↗

Validation of volumetric flow measurements by means of a Doppler-tipped coronary angioplasty guide wire.

We used an in vitro model to validate volumetric flow measurements obtained with an 0.018-inch angioplasty guidewire with a 12 MHz transducer mounted on its tip. By using a modified two-head roller pump device, flow was adjusted incrementally from a minimum of 90 ml/min to a maximum of 550 ml/min. Flow was measured with the Doppler guide wire in tubing ranging from 1.9 mm to 6.0 mm internal diameter, as the product of the spectral Doppler velocity integral and the cross-sectional area of the tubing, over a 1-minute period. It was an excellent correlation between the Doppler calculated flow rates and actual flow, regardless of tubing diameter (r = 0.99). These results suggest that the Doppler spectral output of this device might be accurately applied to estimates of volumetric flow in human coronary arteries.

Angioplasty, Balloon, Coronary↗

Comparative prognostic value of clinical risk indexes, resting two-dimensional echocardiography, and dipyridamole stress thallium-201 myocardial imaging for perioperative cardiac events in major nonvascular surgery patients.

The relative prognostic value of widely accessible resting two-dimensional echocardiographic ventricular function data has not been compared with recognized clinical and scintigraphic risk markers in patients who are unable to exercise before major nonvascular surgery. To this end, 53 consecutive patients aged 67 +/- 13 years undergoing preoperative evaluation (intraabdominal, 23%; orthopedic, 30%; thoracic, 9%; other, 38%) for known or suspected coronary artery disease were followed up to evaluate the prognostic value of these studies for the perioperative cardiac events (cardiac death [n = 4], myocardial infarction [n = 2], unstable angina [n = 3], and pulmonary edema [n = 8]) that occurred in 13 of the 53 patients (25%). Dipyridamole thallium-201 myocardial redistribution defects occurred in 15 (28%) patients. Resting echocardiographic left ventricular dysfunction was present in 21 (40%) patients. Multivariate analysis of clinical, echocardiographic, and scintigraphic risk predictors revealed that cardiac events were not predicted by clinical variables, including Goldman class or score. Cardiac events were independently predicted only by the presence of significant left ventricular dysfunction on resting two-dimensional echocardiography (p < 0.042) and dipyridamole thallium-201 defect redistribution (p < 0.026). A dipyridamole-induced reversible thallium-201 perfusion defect was predictive of subsequent cardiac death or myocardial infarction (p < 0.02), whereas left ventricular dysfunction on resting echocardiography was predictive of perioperative pulmonary edema (p < 0.023). We conclude that stress thallium-201 perfusion imaging and resting two-dimensional echocardiography provide independent prognostic information in patients undergoing major nonvascular surgery who are at significant risk for ischemic cardiac events and who are unable to perform standard exercise stress tests.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty.

OBJECTIVES: This study was designed to assess whether the spectral waveform of coronary velocity on Doppler study is characteristically altered in the presence of significant stenosis with normalization of the spectral waveform after relief of endolumen obstruction. BACKGROUND: Although coronary flow reserve determinations have provided physiologic information complementary to the angiographic percent diameter narrowing, flow velocity measurements have been limited to proximal arteries with inconsistent results after angioplasty. A 12-MHz Doppler guide wire permits flow velocity determination in the proximal and distal coronary artery with fast Fourier spectral analysis. METHODS: With the Doppler guide wire, proximal arterial flow velocity and flow reserve measurements in 17 angiographically normal arteries were compared with measurements in 29 significantly stenosed arteries. Proximal and distal flow velocity measurements were also obtained before and after angioplasty of the 29 abnormal arteries. Velocity spectrum was digitized to compute peak diastolic velocity, peak systolic velocity, mean velocity, diastolic/systolic velocity ratio and first third and first half flow fraction. RESULTS: Compared with proximal stenosed arteries, proximal normal arteries had significantly higher peak diastolic velocity (64 +/- 26 cm/s vs. 41 +/- 26 cm/s) and higher coronary vasodilator reserve (2.3 +/- 0.8 vs. 1.6 +/- 0.7). Normal arteries had higher flows in the first third and first half of the coronary cycle (46 +/- 3% vs. 39 +/- 7% and 65 +/- 2% vs. 56 +/- 10%, respectively). Before angioplasty, coronary velocity variables were significantly lower distal than proximal to the stenosis. After angioplasty, there was a greater mean increase in distal velocities (200% vs. 90% for the proximal arteries) that resulted in near equalization of proximal and distal mean velocity and a significant reduction in proximal/distal mean velocity ratio (2.4 +/- 1.7 vs. 1.2 +/- 0.4). CONCLUSIONS: Before angioplasty, abnormal coronary flow velocity dynamics are more marked distal than proximal to the stenosis. Greater increase in coronary flow velocities in the distal circulation after relief of endolumen obstruction results in a significant reduction in the proximal/distal flow velocity ratio. Thus, normalization of Doppler-derived flow velocity variables with marked reduction of the proximal/distal flow velocity ratios parallels angiographic success and may prove useful as an additional end point measurement in interventional cases with questionable angiographic findings.

Angioplasty, Balloon, Coronary↗

The increasing role of transesophageal echocardiography in unexplained cerebral ischemia.

Cerebrovascular disease is a leading cause of morbidity and mortality in the United States. A significant number of cerebral infarctions are due to a cardiac source of embolus. Transesophageal echocardiography (TEE) is being used with increasing frequency to study patients with potential cardiac causes of cerebral ischemia. TEE has a higher sensitivity for detecting left atrial and left atrial appendage thrombi and for visualizing abnormalities of the atrial septum such as patent foramen ovale and aneurysm. Abnormalities of the aorta and native and prosthetic valves can now be clearly identified by TEE. Preliminary data suggest that TEE may influence clinical management in patients with unexplained stroke.

Brain Ischemia↗

Systemic arterial emboli and cardiac masses. Assessment with transesophageal echocardiography.

Several cardiac and aortic findings on TEE have been implicated as sources for systemic emboli. These findings include left atrial thrombus, left atrial spontaneous contrast, patent foramen ovale, atrial septal aneurysm, and aortic atheroma. The prevalence of each of these abnormalities has been significantly greater in patients with suspected embolic events as compared with controls. Furthermore, the sensitivity of TEE for these findings is much greater than that of TTE. Thus, patients with unexplained cerebral ischemia or systemic emboli should undergo TEE so that possible sources can be detected. In regard to cardiac tumors, although the data are preliminary, certain tumor locations and morphologic aspects are better evaluated with TEE than with other techniques. More importantly, it has been suggested that a change in management of cardiac tumors is initiated by TEE in the majority of instances. TEE provides important diagnostic information in many patients with suspected cardiac emboli and cardiac masses and should be strongly considered in the work-up of such patients.

Adult↗

Mitral valve replacement: randomized trial of St. Jude and Medtronic-Hall prostheses.

To better define the merits of the bileaflet and tilting-disc valves, we prospectively randomized 102 patients (mean age, 57 years; range, 11 to 85 years) to receive either the St. Jude (n = 55) or the Medtronic-Hall (n = 47) mitral valve prosthesis between September 1986 and May 1991. The two groups were not different with respect to preoperative New York Heart Association class, incidence of mitral stenosis and insufficiency, angina score, extent of coronary artery disease, ventricular function, completeness of revascularization, or cross-clamp or bypass time. The hospital mortality (14.5% versus 10.6%, St. Jude versus Medtronic-Hall) and late mortality (7.3% versus 2.1%) were not significantly different. Follow-up was complete in 84 of 89 hospital survivors (94%) with a mean of 26 months (range, 1 to 60 months). The linearized rates of valve-related events and the 3-year actuarial survival demonstrated no significant differences between both cohorts. Comparison of the clinical outcome and echocardiographic parameters obtained at the time of follow-up demonstrated no significant differences between the two prostheses. These data indicate that the Medtronic-Hall and St. Jude mitral prostheses are similar with respect to their rates of valve-related complications and hemodynamic profiles. This study suggests that there is no difference between the St. Jude and Medtronic-Hall prostheses with regard to early clinical performance or hemodynamic results and therefore does not support the preferential selection of either prosthesis.

Adolescent↗

Quantitation of mitral regurgitation by transesophageal echocardiography with Doppler color flow mapping: correlation with cardiac catheterization.

Eighty consecutive patients who underwent both left ventriculography and single-plane transesophageal echocardiography with Doppler color flow mapping were studied to compare the two techniques in the assessment of mitral regurgitation. Only the mosaic aspect of the regurgitant jet was included in the measurements. Values for inter- and intraobserver variability for the maximal regurgitant area measurements were 10 +/- 9% and 9 +/- 8%, respectively. The best correlation between angiography and Doppler color flow imaging was obtained with the maximal regurgitant area (r = 0.90). A maximal regurgitant area less than 3 cm2 predicted mild mitral regurgitation with a sensitivity of 96%, specificity of 100% and a predictive accuracy of 98%, whereas a maximal regurgitant area greater than 6 cm2 predicted severe mitral regurgitation with a sensitivity of 91%, a specificity of 100% and a predictive accuracy of 98%. A strong, although inferior, correlation was found for the maximal regurgitant area/left atrial area ratio (r = 0.81). A ratio less than 20% predicted mild mitral regurgitation with 94% accuracy, whereas a ratio greater than 35% predicted severe mitral regurgitation with 85% accuracy. Thus, single-plane transesophageal echocardiography with Doppler color flow mapping is an exquisitely sensitive technique for the diagnosis of mitral regurgitation. Minimal degrees of mitral regurgitation can be detected in approximately 62% of patients in whom no mitral regurgitation is detected by angiography. The mosaic maximal regurgitant area is a simple and easily obtainable Doppler echocardiographic index that provides an accurate estimation of mitral regurgitation severity.

Cardiac Catheterization↗

Dipyridamole echocardiography.

Intravenous dipyridamole is a potent coronary vasodilator that has been extensively investigated over the past several years in the noninvasive assessment of patients with suspected coronary artery disease when exercise cannot be performed or is suboptimal. As an alternative to exercise studies, dipyridamole has been used in combination with different cardiac imaging techniques such as echocardiography, thallium scintigraphy, and radionuclide ventriculography. Extensive experience has been obtained with dipyridamole thallium-201 imaging for coronary artery disease screening, risk stratification, and prognosis after an acute coronary event. However, experience with the use of dipyridamole in combination with two-dimensional echocardiography has been limited. Dipyridamole increases coronary blood flow in nondiseased coronary vessels relative to coronary vessels with significant luminal narrowings. These provide the basis for detecting regional differences in flow by using different cardiac imaging techniques. Two-dimensional echocardiography would show regional wall-motion abnormalities in response to those regional differences in coronary blood flow. In this article, the most commonly used protocols, safety, and practicability of dipyridamole echocardiography are reviewed. As an alternative to exercise, dipyridamole echocardiography shares all the indications of a standard exercise test. Clinical applications of dipyridamole echocardiography include coronary artery disease screening, suspected coronary artery spasm, postmyocardial infarction risk stratification, evaluation of percutaneous transluminal coronary angioplasty results, and prognosis following an acute coronary event. Compared to conventional (ECG) exercise testing, dipyridamole echocardiography appears to be equally sensitive but more specific. Compared to atrial pacing, dipyridamole provokes ischemia at a lower rate pressure product and results in a greater ST segment depression suggesting that dipyridamole induces more profound myocardial ischemia than atrial pacing. Dipyridamole thallium and exercise thallium have shown to be equally sensitive and specific in the assessment of coronary artery disease. High dose dipyridamole echocardiography appeared to be equally sensitive and more specific. Experimental studies have demonstrated that dobutamine appears to be a more powerful pharmacological agent in inducing wall-motion abnormalities. Dipyridamole echocardiography as compared to stress echocardiography offers the advantage of obtaining better quality postintervention images. With regard to sensitivity and for coronary artery disease diagnosis, both techniques appear to render similar results. Although further studies are needed, the available data indicates that cardiac ultrasound imaging prior to and following the intravenous administration of dipyridamole may be an attractive alternative to thallium perfusion imaging in the clinical setting, particularly when radionuclide capabilities are not present.

Angioplasty, Balloon, Coronary↗