A review of the physical properties and biological effects of the high amplitude acoustic field used in extracorporeal lithotripsy.

Extracorporeal shockwave lithotripsy (ESWL) has now been used for more than a decade in the treatment of urinary stone disease. During this period there has been a wide range of studies on the physical properties of the high-amplitude focussed fields used in ESWL and the biological effects of exposure to such fields, including their ability to fragment hard concretions. These studies form a distinct body of knowledge whose relevance to the broader literature on biological effects from lower amplitude exposures has yet to be fully evaluated. This review attempts to present the main results of biological-effects studies in ESWL along with what is known of the physical properties of lithotripsy fields with the aim of assisting this evaluation. In general, the reported biological effects of lithotripsy fields are compatible with those that have been observed at those lower amplitudes of focussed pulsed ultrasound in which transient cavitation is the dominant mechanism of interaction. The relatively large amplitudes and low frequencies in ESWL, however, make it a more potent generator of transient cavitation than most other forms of medical ultrasound. Biological-effects studies with lithotripsy fields may, therefore, be expected to extend our understanding of the nature of transient cavitation and, in particular, its effects in mammalian tissue.

Acoustics↗

The spatial distribution of cavitation induced acoustic emission, sonoluminescence and cell lysis in the field of a shock wave lithotripter.

This study examines the spatial distribution of various properties attributed to the cavitation field generated by a shock wave lithotripter. These properties include acoustic emission and sonoluminescence, which result from violent bubble collapse, and the degree of cell lysis in vitro, which appears to be related to cavitation. The acoustic emission detected with a 1 MHz, 12 cm diameter focused hydrophone occurs in two distinct bursts. The immediate signal is emitted from a small region contained within the 4 MPa peak negative pressure contour. A second, delayed, burst is emitted from a region extending further along the beam axis. The delay between these two bursts has also been mapped, and the longest delay occurs at positions close to the regions of maximum peak negative pressure. Sonoluminescence from both single and multiple shocks occurs in a broader region than the acoustic emission but the measurement technique does not allow time resolution of the signal. Cell lysis occurs in a relatively small region that correlates closely with the immediate acoustic emission for a shock propagating in a gelatine solution.

Acoustics↗

The influence of fluid properties and pulse amplitude on bubble dynamics in the field of a shock wave lithotripter.

This study concerns the radial dynamics of a bubble driven by pulsed ultrasound of the type generated during extracorporeal shock wave lithotripsy. In particular, a numerical model has been used to examine the sensitivity of the bubble oscillations to changes in both the amplitude of the driving field and the physical conditions of the fluid surrounding the bubble: viscosity, surface tension, temperature and gas content. It is shown that, at high negative pressures (p- = 10 MPa) as in lithotripsy, the timing and amplitude of bubble collapses have a considerably reduced sensitivity to the initial bubble size and all fluid parameters, except gas content, compared with those expected in lower-amplitude fields (p- = 0.2 MPa). This study indicates that, in the lithotripsy fields, the differences in the viscosity, surface tension and temperature of body fluids and the initial bubble size will have little effect on bubble dynamics compared with those expected in water.

Humans↗

Acoustic emission and sonoluminescence due to cavitation at the beam focus of an electrohydraulic shock wave lithotripter.

The acoustic emission from cavitation in the field of an extracorporeal shock wave lithotripter has been studied using a lead zirconate titanate piezoceramic (PC4) hydrophone in the form of a 100-mm diameter focused bowl of 120-mm focal length. With this hydrophone directed at the beam focus of an electrohydraulic lithotripter radiating into water, it is possible to identify signals well above the noise level, at the 1-MHz resonance of the hydrophone, which originate at the beam focus. Light emission, attributed to sonoluminescence, is also shown to originate at the focal region of the lithotripter, and the signal obtained from a fast photomultiplier tube directed at the focus has similarities in structure and timing to the detected acoustic signals. The multiple shock emission resulting from a single discharge of an electrohydraulic source is shown to result in two separate bursts of cavitational activity separated by a period of 3-4 ms. The signal burst corresponding to the primary shock has a duration of about 600 microseconds with little noticeable structure. The signal burst associated with the secondary shock has a reproducible structure with two distinct peaks separated by about 200 microseconds depending on the shock amplitude. THe timing and structure of each burst is shown to be in reasonable agreement with the theoretical predictions made by Church (1989) based on the Gilmore model of bubble dynamics. In particular, it is shown that it is possible to obtain precise measurements of the time delay between the separate peaks within the signal burst detected following the secondary shock and this may, as predicted, provide a method of determining the size of bubbles remaining after the primary shock.

Acoustics↗

Theoretical predictions of the acoustic pressure generated by a shock wave lithotripter.

A one-dimensional frequency domain model is used to predict the temporal peak acoustic pressures developed near the beam focus during extracorporeal shock wave lithotripsy (ESWL). The model includes consideration of finite amplitude effects, attenuation, diffraction and dispersion, and results are presented for the case of an electrohydraulic source with the beam geometry of the Dornier HM3 lithotripter. Propagation in castor oil, water and tissue is examined. The model predicts that nonlinear effects enhance the peak positive pressure (p+) at the beam focus in 6 cm of tissue in a Dornier type lithotripter by a factor of about 3 above that which would be expected for linear propagation. The negative peak pressure (p-), conversely, is predicted to be depressed by a factor of about 0.7 below the linear theory prediction. The model also indicates the occurrence of excess absorption due to shock formation. This is shown, for a Dornier HM3 type lithotripter, to cause a reduction in the peak positive pressure gain and a broadening of the focal depth as the output of the source is increased. A threshold aperture pressure is identified for a source with the same beam geometry as the Dornier HM3 below which shock formation does not occur. In this region the pressure gain increases and the focal depth narrows as the source output increases. These effects are characteristic of current commercial piezoelectric and electromagnetic lithotripsy fields.

Humans↗

A survey of the acoustic output of commercial extracorporeal shock wave lithotripters.

A survey of the pressures and intensities generated by different commercial extracorporeal shock wave (ESWL) lithotripters is reported. The lithotripters included in the survey are the Dornier HM3, Wolf Piezolith 2200 and 2300, Siemens Lithostar, Technomed Sonolith 2000 and 3000, and EDAP LT-01. Measurements were made using a polyvinylidene difluoride (PVdF) membrane hydrophone in water. The zero crossing frequency of one complete cycle of the focused pulse from ESWL equipment is in the range 0.1 to 1 MHz. Spatial-peak temporal-peak positive and negative pressures up to 114 MPa and 10 MPa, respectively, have been measured and the rise times of the positive pressure half cycle at maximum output settings are 30 ns or less. The mean spatial-peak temporal-average intensity of the lithotripters is 5.0 x 10(2) W m-2 when operated at a pulse repetition frequency of 1 Hz. The spatial-peak pulse-average intensity ranges from 6.6 x 10(7) to 1.24 x 10(9) W m-2. The estimated acoustic energy in a single pulse (at the focus) at the maximum output setting of the lithotripters varies from 2.0 x 10(-3) J to about 9.0 x 10(-2) J. The beam area in the focal plane varies by a factor of 100 on different lithotripters and the temporal-peak pressure at the position of the skin at the entry point of the beam by a factor of 30. Measurement problems associated with hydrophone damage and the uncertainties in the hydrophone calibration at high pressures are discussed and an estimate of the total uncertainty in the absolute measurements of the spatial-peak temporal-peak positive pressure is given as +/- 36%.

Acoustics↗

An experimental shock wave generator for lithotripsy studies.

An electrohydraulic shock wave generator has been constructed to facilitate investigation of the acoustic field generated during extracorporeal shock wave lithotripsy (ESWL). Pressure waveforms at the generator aperture and the beam focus, measured using a PVDF needle hydrophone, are compared with those from a commercial lithotripter, the Dornier HM3.

Acoustics↗

Physical characteristics of Dornier extracorporeal shock-wave lithotriptor.

Measurements of the pressure, noise, and radiation dose levels from a Dornier lithotriptor are reported. The distribution of the peak pressure around the treatment focus was investigated, and the highest pressures were found to occur within an elongated volume. Within the treatment room, noise levels of 80-90 dB were produced during each shock wave, rising to 95 dB by the patient's head. Ear protection for the staff and patient is recommended, and careful room design is necessary to minimize the sound disturbance to adjacent quarters. Measurements of the radiation skin dose received by patients from the x-ray localization system were relatively high and ranged from 2-55 cGy (rad), with a mean of 12 cGy. The operator needs to be aware of these high doses and should take precautions to minimize them.

Ear Protective Devices↗

Pressure waveforms generated by a Dornier extra-corporeal shock-wave lithotripter.

Pressure waveforms in the acoustic field generated by a Dornier (HM3) shock-wave lithotripter have been measured using a bilaminar shielded PVDF membrane hydrophone in water. Using these waveforms, values of the peak-positive (p+) and peak-negative pressure (p-) at various positions in the field have been estimated. At the focus, p+ is 38.6 MPa (standard deviation = 9.0 MPa) and p- is 10.1 MPa (standard deviation = 1.0 MPa) at 20 kV discharge potential and an electrode separation in the range 1.3 to 2.4 mm. The peak-positive pressure is found to fall to 50% (-6 dB level) at about 60 mm either side of the focus on the major axis of the reflector and on a 10 mm radius circle around the focus in the focal plane. A shot-to-shot variation of +/- 25% in p+ is attributed to the inherent variability of the electrical discharge which may result in changes in the exact position and strength of the acoustic field. The results reported are considered to be more accurate than those of previous measurements due to the relatively flat frequency response of this type of hydrophone.

Acoustics↗

Acoustic cavitation generated by an extracorporeal shockwave lithotripter.

Evidence is presented of acoustic cavitation generated by a Dornier extracorporeal shockwave lithotripter. Using x-ray film, thin aluminum sheets, and relatively thick metal plates as targets, evidence of liquid jet impacts associated with cavitation bubble collapse was observed. The jet impact was violent enough to puncture thin foils and deform metal plates. Furthermore, numerous jet impacts were generated over a volume of greater than 200 cm3. It is likely that such violent cavitation will also occur in tissue, and observed biological effects (e.g. renal calculus disintegration and tissue trauma) may be related to cavitation damage.

Lithotripsy↗

A survey of 29 EMI CT machines in Britain.

During 1978/79 a survey was made of the performance characteristics of 29 EMI brain and body CT scanners in Britain. Comparative data on such performance parameters as noise, uniformity of CT numbers, low-contrast detectability, resolution, modulation transfer function (MTF) and effective photon energy were measured using a set of regular-geometry and anthropomorphic phantoms. In addition, dose profiles were obtained for a single slice using TLD and film. The results of the survey are presented; the dependence of the performance characteristics on the types of machines surveyed and the operating modes employed is discussed.

Brain↗

Metabolism and kinetics of oxaprozin in normal subjects.

Absorption, biotransformation, excretion, and kinetics of oxaprozin (4,5-diphenyl-2-oxazolepropionic acid) were examined in subjects after an oral dose of 14C-oxaprozin alone as well as before, during, and after long-term administration of unlabeled drug. A single dose of 14C-oxaprozin was rapidly absorbed and the unchanged drug was essentially the only labeled substance in plasma. Recovery of radioactivity in excreta, mostly in urine, exceeded 90%. Major biotransformation routes were glucuronidation of the carboxyl group and hydroxylation of the phenyl rings followed by glucuronidation. Administration of unlabeled oxaprozin did not affect the absorption, qualitative, or quantitative metabolite profile, or recovery of 14C-oxaprozin. Following a single dose, the kinetic parameters for 14C and unchanged drug in plasma were nearly the same. A2-compartment model with first-order elimination adequately describes kinetic disposition. The slow clearance (Clp), 0.08 to 0.12 1/hr, was almost entirely due to biotransformation and the plasma half-lifes, which ranged from 49 to 69 hr, reflected the small Clp. The small volume of distribution (VD beta = 8 to 9 1) indicates limited extravascular distribution. Multiple doses of unlabeled drug, especially when given concurrently, increased the Clp of 14C-oxaprozin. This effect is apparently related to decreased binding of high concentrations of oxaprozin to plasma protein. As a result of increased Clp, steady-state levels are only 40% of levels predicted from the single-dose study.