A J Camm

Publications and source records attributed to A J Camm.

At least 19 recordsLinked to original sources

Cost implications of the British Pacing and Electrophysiology Group's recommendations for pacing.

OBJECTIVE: To compare present pacing practice with the recommendations recently published by the British Pacing and Electrophysiology Group and to assess the increase in annual budget required to implement these recommendations in a regional cardiothoracic unit. DESIGN: Retrospective analysis of pacemaker implantation for 1991 with calculation of the costs required to implement the group's recommendations based on average 1991 costs of the types of pacing generators and electrode leads used. SETTING: Regional cardiothoracic unit for South West Thames Health Authority. PATIENTS: 433 consecutive patients receiving permanent pacemaker generators: 76 (18%) with sinus node disease; 270 (62%) with atrioventricular block; 25 (6%) with both sinus node disease and atrioventricular block; 59 (14%) with chronic atrial fibrillation and atrioventricular block; and 3 (1%) with carotid sinus or malignant vasovagal syndromes. RESULTS: Only 102 (24%) patients received pacemaker generators recommended by the British Pacing and Electrophysiology Group; however, 355 (82%) patients were older than 65 years, and 264 (61%) were aged 75 or over. The cost of hardware for pacing was 462,885 pounds. Using generators as recommended would have cost 810,525 pounds for "optimal" systems (an increase of 75%) and 710,750 pounds for "alternative" systems (an increase of 54%). These increases would have been considerably reduced by limiting the use of sophisticated pacing to younger patients (aged under 75). Further savings could be made by using the least expensive pacing models available. CONCLUSIONS: Implementing these recommendations should reduce morbidity related to bradyarrhythmia but will lead to major increases in pacing costs. Age and patients' expected activity may be used to select simple pacing systems and thus to contain cost. More research is needed to determine which patient groups will benefit most from complex pacing systems.

Adult

Effects of flecainide on atrial electrophysiology in the Wolff-Parkinson-White syndrome.

The effects of intravenous flecainide and propafenone (2 mg/kg) administered in random order were compared in 16 patients with Wolff-Parkinson-White syndrome. Both agents prolonged significantly the anterograde refractory period of the pathway and caused complete anterograde block in the pathway in 5 patients. Atrial fibrillation was not inducible in 7 patients following both agents. Both drugs prolonged the minimum pre-excited RR interval, but this effect was significantly greater after flecainide than after propafenone. At a pacing cycle length of 500 msec, the atrial effective refractory period was unchanged after flecainide, but the atrial monophasic action potential duration, and the atrial monophasic action potential duration of the earliest inducible atrial beat were significantly increased. These results suggest that rate-dependent prolongation of atrial repolarization does not occur following clinical intravenous doses of flecainide. The prolongation of the repolarization of ectopic beats may prevent induction of atrial arrhythmias and may also have an important role in the termination of atrial fibrillation.

Atrial Fibrillation

Differences between predictive characteristics of signal-averaged electrocardiographic variables for postinfarction sudden death and ventricular tachycardia.

Several studies indicate that the electrophysiologic substrate for sustained ventricular tachycardia differs from that of ventricular fibrillation. This prospective study examined whether there were clinically relevant differences between the predictive values of the standard time-domain signal-averaged (SA) electrocardiographic (ECG) variables for ventricular tachycardia and sudden death after myocardial infarction. Predischarge SA electrocardiograms were recorded in 332 patients after infarction. During a follow-up period of greater than or equal to 6 months, there were 12 sudden deaths (3.6%), 14 patients (4.2%) developed spontaneous sustained ventricular tachycardia and 20 patients (6%) died of circulatory failure. The sensitivity, specificity and positive predictive accuracy of the numerical values of the time-domain SA electrocardiographic variables for predicting sudden death and ventricular tachycardia were compared. The optimal criteria for predicting ventricular tachycardia required the positivity of greater than or equal to 2 of the standard time-domain SA variables, whereas the optimal criteria for predicting sudden death required the positivity of all 3 variables. A high specificity was sustained over a wider range of sensitivity for sudden death than it was for ventricular tachycardia and the values of the variables which provided the same sensitivity for sudden death and ventricular tachycardia were different. For a sensitivity of 70%, the positive predictive accuracy was 31% for predicting sudden death and 13% for predicting ventricular tachycardia. The study concludes that differences in the predictive characteristics of variables for ventricular tachycardia and sudden death may be used to refine postinfarction risk stratification.

Adult

Assessment of QT dispersion in symptomatic patients with congenital long QT syndromes.

It has been suggested that QT dispersion recorded on the surface electrocardiogram may be a predictor of arrhythmic events in patients with congenital QT prolongation. To evaluate this, 9 patients (6 female, mean age 17.6 years) with congenital long QT syndromes, all of whom had syncope and documented torsades de pointes, were studied. Patients were studied off treatment and during therapy with beta-blocking agents. Three patients were also studied after left stellate ganglionectomy. An age-matched control group was also studied. Good quality 12-lead electrocardiograms were recorded from all patients. For each lead, QT and RR intervals were measured, and QTc value was calculated. QT and QTc dispersions were calculated for each patient. Patients had a significantly longer mean QT interval compared with that of the control group (450 +/- 100 vs 359 +/- 63 ms; p = 0.015) at similar mean RR intervals (736 +/- 231 vs 783 +/- 289 ms), with a longer mean QTc value (0.53 +/- 0.08 vs 0.41 +/- 0.02 s1/2; p = 0.004). Patients also had longer QT and QTc dispersions compared with those of the control group (110 +/- 45 vs 43 +/- 12 ms [p = 0.004], and 0.108 +/- 0.03 vs 0.05 +/- 0.02 s1/2 [p = 0.002], respectively). QT and QTc dispersions on and off beta-blocking agents were not significantly different. Comparing patients with frequent and those with infrequent symptoms, there was no difference in QT or QTc dispersion either off treatment or during therapy with beta-blocking agents.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Is hypomagnesemia arrhythmogenic?

An understanding of the role of magnesium in cardiac conduction is complicated by the multiplicity of intracellular events coordinated by the magnesium ion. Several reports have cited magnesium deficiency as the cause of a variety of ventricular and supraventricular arrhythmias. On further inspection, the circumstances of each report strongly suggest the coexistence of significant potassium depletion; isolated hypomagnesemia as a cause of arrhythmia is not reported. This discussion brings together new data from basic science with that of clinical research to refute the suggestion that isolated hypomagnesemia is arrhythmogenic. However, there is sufficient evidence to indicate that hypomagnesemia will significantly exacerbate the proarrhythmic effect of hypokalemia, particularly if occurring in the presence of digoxin toxicity. Potassium and magnesium depletion are commonly concomitant, and simultaneous repletion of both ions in the presence of hypokalemia-induced arrhythmia would be both logical and effective. The beneficial effects of intravenous magnesium in the acute control of ventricular tachyarrhythmia are concluded to occur as a result of a separate antiarrhythmic action, quite independent of underlying magnesium balance.

Arrhythmias, Cardiac

Benefits of the advances in cardiac pacemaker technology.

Pacemaker technology has expanded rapidly in the last thirty years. Each phase of development has been marked by both improvements in clinical benefit and disadvantageous interactions of physiology and technology. Each phase of development has led to smaller, more reliable devices with greater programmability. Advances in generator technology and battery design have increased longevity of devices. The first devices used asynchronous pacing which had a significant effect in reducing the mortality of surgically induced complete heart block. Ventricular demand pacemakers overcame the problems of asynchronous competitive pacing, but exposed the pacemaker syndrome. Atrioventricular sequential pacing restored atrioventricular synchrony, resulting in hemodynamic improvement, but created the phenomenon of pacemaker-mediated tachycardia. Alternative dual chamber modes and algorithms have largely resolved this. Adaptive-rate devices have been of benefit to patients with chronotropic incompetence, and are now incorporating an increasing variety of biosensors. Almost all the problems of pacing have been overcome, but the increasing complexity of pacemaker technology is now a major limitation to its proper use.

Arrhythmias, Cardiac

Transesophageal contrast echocardiography and color flow mapping: methods of choice for the detection of shunts at the atrial level?

The detection of shunts at the atrial level is important, and a reliable means of diagnosis is required. Precordial contrast echocardiography is usually performed to detect such shunts. To investigate the advantages of transesophageal echocardiographic techniques, we studied 167 consecutive patients with both precordial and transesophageal echocardiography, using two-dimensional imaging with contrast techniques (with and without a Valsalva maneuver) and color flow mapping. A patent foramen ovale was diagnosed in 31 patients, an atrial septal defect in 11 (7 with bidirectional shunts), and a pulmonary arteriovenous fistula in 3 patients. All right-to-left shunts were detected with transesophageal contrast echocardiography. With these results used as the gold standard, the sensitivity of combined precordial techniques was 37% and that of transesophageal color flow mapping 46%. All left-to-right shunts were detected by transesophageal color flow mapping. With these results used as the gold standard, the sensitivities of both precordial color flow mapping and a transesophageal negative right atrial contrast study were 27%. We conclude that transesophageal contrast echocardiography is the echocardiographic method of choice for the detection of a right-to-left shunt at the atrial level, which cannot be excluded by negative results on precordial study or on transesophageal color flow map study. A left-to-right shunt at this level is best detected by transesophageal color flow mapping.

Arteriovenous Fistula

A prospective study of the efficacy and safety of adjuvant metoprolol and xamoterol in combination with amiodarone for resistant ventricular tachycardia associated with impaired left ventricular function.

Combination antiarrhythmic drug therapy may be more effective than treatment with a single agent for control of refractory cases of sustained ventricular tachycardia (VT). In a prospective randomized crossover study of 20 patients with impaired left ventricular function (ejection fraction of 28% +/- 8%) and recurrent VT in spite of treatment with amiodarone, we compared the efficacy and safety of adjuvant therapy with metoprolol, 50 mg two times daily and xamoterol, 200 mg two times daily. Metoprolol caused hemodynamic deterioration in five patients, and only one also experienced intolerance to xamoterol. Sustained VT was inducible in all 20 patients who were receiving amiodarone alone but was suppressed or rendered nonsustained in 8 of 20 patients during treatment with amiodarone plus xamoterol and in 6 of 17 patients during treatment with amiodarone plus metoprolol. Addition of xamoterol restored sinus rhythm in four patients who presented with incessant VT, and metoprolol was effective for three of them. Neither beta-blocker significantly altered tachycardia cycle length or any electrophysiologic parameter other than the slowing of the sinus rate. Both beta-blockers suppressed exercise-induced VT in 3 of 4 patients, and addition of xamoterol significantly increased treadmill exercise duration (7.1 +/- 1.8 min) compared with administration of amiodarone alone (3.8 +/- 1.5 min; p < 0.01). Fourteen patients were discharged with prescriptions for amiodarone-beta-blocker combinations. During a mean follow-up period of 13 months (range, 2 to 24 months), there were three cases of recurrent VT (in all patients VT remained inducible) and no sudden deaths.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Transoesophageal echocardiography in the diagnosis of paradoxical embolism.

Two patients with systemic embolism were studied with transoesophageal contrast echocardiography which demonstrated its probable paradoxical nature. In both cases paradoxical embolism was associated with pulmonary embolism. Precordial contrast echocardiography demonstrated a right-to-left shunt in one patient but was unable to demonstrate a shunt in the second. Transoesophageal echocardiography suggested that the shunt was across a patent foramen oval in both cases and revealed large thrombi in the pulmonary arteries in one. When precordial contrast echocardiography reveals a right-to-left shunt or when it is technically inadequate in patients suspected of having one, transoesophageal contrast echocardiography can demonstrate the nature of the shunt and is an alternative to cardiac catheterisation techniques. In addition, it can reveal large thrombi in the pulmonary arteries.

Adolescent

Myocardial magnesium depletion associated with prolonged hypomagnesemia: a longitudinal study in heart transplant recipients.

OBJECTIVES: This study was carried out to establish prospectively the incidence and relation of hypomagnesemia and myocardial magnesium depletion after heart transplantation. BACKGROUND: No serial in vivo study of the relation of serum with tissue magnesium has been described. Myocardial magnesium depletion is associated with intracellular calcium overload, an increased incidence of cardiac arrhythmia and changes in coronary vasculature similar to those seen in the accelerated atherosclerosis that compromises graft survival after transplantation. METHODS: In a prospective study in 19 consecutive patients, serum and myocardial magnesium content were measured serially for 9 months after heart transplantation. Blood cyclosporine was assayed simultaneously. RESULTS: The incidence of hypomagnesemia was 100% during the 9-month study period, with lowest levels at 3 months (mean 0.80 vs. 0.64 mmol/liter, p less than 0.002). Myocardial magnesium depletion developed in 94% and was persistent in 55%; the lowest levels occurred at 6 months (mean 33.6 vs. 30.1, mumol/g, p less than 0.04). Hypomagnesemia predated decreases in myocardial magnesium by 2 to 6 weeks. Peak cyclosporine levels correlated positively with the decrease in serum magnesium. Clinical events were rare. CONCLUSIONS: This is the first report of serial measurement of tissue magnesium. Persistent hypomagnesemia is invariably accompanied by myocardial magnesium depletion in the transplanted heart. Reciprocal calcium overload and adverse changes in coronary vasculature would be expected from previous studies and merit further investigation. Should the implications of this study extend to the native heart, myocardial magnesium depletion may contribute to the high incidence of fatal arrhythmic events observed in patients with heart failure, who commonly have persistent hypomagnesemia.

Cyclosporine

Effect of induced supraventricular tachycardias on changes in urine output and plasma hormone levels in man.

1. A symptomatic diuresis, polyuria, sometimes accompanies paroxysmal tachycardias in man. A study was undertaken in patients with inducible supraventricular tachycardia, irrespective of the symptom of polyuria, to measure simultaneous changes in urine output and plasma hormone levels during the arrhythmia. 2. During 14 episodes of induced tachycardia in 10 patients, there was a significant increase in mean urine flow, which was independent of the state of patient hydration. During a mean tachycardia duration of 30 +/- 3 min, the mean group urine flow increased from 3.2 +/- 2.3 ml/min to 7.6 +/- 3.7 ml/min (P less than 0.001). This was characterized by a consistent increase in free water excretion and a variable increase in sodium excretion. 3. The plasma atrial natriuretic peptide level (five patients) significantly increased from 7.6 +/- 4.6 pg/ml to 34.6 +/- 21.7 pg/ml (P less than 0.02) during the arrhythmia. There was no significant change in the plasma arginine-vasopressin level and a non-significant reduction in plasma renin activity. 4. This study has shown that induced supraventricular tachycardias in man are accompanied by a significant diuresis. The mechanisms responsible remain unknown, but do not appear to involve the plasma arginine-vasopressin level alone.

Adult

Effects of myocardial electrotonic interaction on the sequence of excitation and repolarisation and on T wave polarity. Computer modelling experiments.

A computer model of a 3-dimensional rectangular block of myocardial tissue (3969 cells) has been used to investigate the influence on excitation and repolarisation sequences and on the modelled electrocardiographic T wave of (a) electrotonic interaction, (b) intrinsic distribution of refractoriness, and (c) the speed of repolarisation of action potentials. The model allowed electrotonic interactions to be investigated separately during the depolarisation and repolarisation phases. Scales of 14 values of the strength of electrotonic interaction during the depolarisation phase, 14 values of the strength of electrotonic interaction during the repolarisation phase, 3 shapes of action potential, and 5 distributions of tissue refractoriness were selected and all 2940 combinations were examined. In each experiment, the tissue model was artificially excited and the resulting excitation and repolarisation sequences were simulated. The results of the study suggested that electrotonic interactions between excited cells can cause non-uniform speed of propagation which, by means of the phase shifts of action potentials, contributes to the inversion of the repolarisation sequence and to the physiologic orientation of T waves. Experiments with this model did not support the hypothesis that simple electrotonic smoothing of the differences in repolarisation phases due to the excitation phase shift of action potentials reverses the repolarisation sequence and explains T wave polarity.

Action Potentials

Effect of intravenous adenosine on human atrial and ventricular repolarisation.

OBJECTIVE: The aim was to assess the effects of therapeutic doses of intravenous adenosine on human atrial and ventricular repolarisation. METHODS: The effects of 6 mg and 12 mg bolus doses of adenosine on the atrial and ventricular monophasic action potentials were studied using the contact catheter technique in 19 patients undergoing routine diagnostic electrophysiology studies. The effect on atrial repolarisation was studied before and after beta blockade in a subgroup of patients. RESULTS: The duration of the monophasic action potential to 90% repolarisation (MAPD90) was measured in all cases. After 6 mg of adenosine the atrial MAPD90 shortened from 227(SD 29) ms to 188(25) ms (p < 0.005); after 12 mg it shortened from 221(31) ms to 168(32) ms (p < 0.001). The maximum shortening was unaltered by propranolol 0.15 mg.kg-1. The ventricular MAPD90 showed no significant change after 12 mg, at 240(32) ms v 234(33) ms. CONCLUSIONS: Therapeutic doses of adenosine shorten the atrial but not the ventricular monophasic action potential duration. The effect is dose dependent and not abolished by beta blockade.

Action Potentials

How to prescribe and manage antiarrhythmic drug therapy.

The pharmacological approach is the corner-stone of therapy for arrhythmia because it is non-invasive, convenient and widely available. However, the indications for antiarrhythmic therapy in general, as well as the indications for drug therapy as opposed to non-pharmacological therapeutic methods, are far from clearly defined. Among the existing antiarrhythmic drugs, clear reduction of mortality due to arrhythmia has been shown definitively only with beta-blocking agents and possibly with amiodarone.

Anti-Arrhythmia Agents

Cardiac pacing and aviation.

Certain applicants with stable disturbances of rhythm or conduction requiring cardiac pacing, in whom no other disqualifying condition is present, may be considered fit for medical certification restricted to multi-crew operations. The reliability of modern pacing systems appears adequate to permit restricted certification even in pacemaker dependent subjects except for certain models of pacemakers and leads known to be at increased risk of failure. These are to be avoided. There is little evidence to suggest that newer devices are any more reliable than their predecessors. Single and dual chamber systems appear to have similar reliability up to 4 years, after which time significant attrition of dual chamber devices occurs, principally due to battery depletion. All devices require increased scrutiny as they approach their end of life as predicted from longevity data and pacing characteristics. Unipolar and bipolar leads are of similar reliability, apart from a number of specific bipolar polyurethane leads which have been identified. Atrial leads, particularly those without active fixation, are less secure than ventricular leads and applicants who are dependent on atrial sensing or pacing should be denied certification. Bipolar leads are to be preferred due to the lower risk of myopotential and exogenous EMI. Sensor-driven adaptive-rate pacing systems using active sensors may have reduced longevity and require close scrutiny. Activity-sensing devices using piezoelectric crystal sensors may be subject to significant rate rises in rotary wing aircraft. The impracticality of restricted certification in helicopters will, in any event, preclude certification. Such devices would best be avoided in hovercraft (air cushioned vehicle) pilots. Only minor rate rises are likely in fixed-wing aircraft which are unlikely to be of significance. Anti-tachycardia devices and implanted defibrillators are inconsistent with any form of certification to fly.

Aerospace Medicine