Preimplantation echo Doppler evaluation of VVI versus DDD pacing.

UNLABELLED: This study was carried out to select before permanent pacemaker implantation patients with complete atrioventricular block (CHB) who would benefit best from DDD pacing, and to determine the optimal atrioventricular delay (AVD) for each of those patients. This was achieved with the aid of Doppler echocardiography. The effect of different AVDs on both the systolic and diastolic function of the normal and failing heart was also delineated in this study. METHODS: Thirty patients with CHB and normal sinoatrial function were selected, with no age or sex predilection. These patients were categorized into three equal groups: groups A, B, and C with normal left ventricular (LV) systolic and diastolic function, LV diastolic dysfunction, and LV systolic dysfunction, respectively. For each patient, systolic and diastolic function was calculated utilizing echo Doppler during CHB, temporary VDD pacing with different AVDs, and temporary VVI pacing with a rate matching that during VDD mode. Temporary VDD mode of pacing was performed utilizing a temporary bipolar ventricular lead for ventricular pacing and an esophageal lead for atrial sensing to trigger ventricular pacing. RESULTS: Qualitatively the most obvious change in the pattern of LV filling as AVD is increased in the three groups, is the earlier occurrence of active atrial filling A wave due to progressive approximation of the ECG P wave toward the previous QRS. As the AV interval is increased, the following changes occur: (a) A wave occurs progressively earlier with superimposition onto the early filling E wave resulting in a progressive increase in its velocity (VA), its FVI, and its percent atrial contribution (%AC); (b) the three times diastolic filling time (DFT), mitral valve opening to Q wave (MVO-Q), and closure (Q-MVC) progressively shorten; (c) since DFT decreases, less passive filling occurs early during diastole, thus E.FVI decrease with longer AV intervals; (d) the ratios VE/VA and FVI E/A decrease subsequently to the previous described changes. Compared to CHB, percent ejection fraction (% EF) was not significantly changed during VVI pacing. Percent EF increased significantly during VDD in comparison to VVI pacing modes. Percent EF was highest at optimal AVD and decreased as this AVD increased or decreased. The cardiac output (CO) increment during VDD in comparison to VVI pacing modes differed much among the three groups. In group A, a 10.29% increase in CO was seen when comparing VDD pacing (with optimal AVD) with that of VII one; in group B, this increment was much greater and reached 29.48%; in group C it reached 23.68%.(ABSTRACT TRUNCATED AT 400 WORDS)

Blood Flow Velocity↗

A new acceleration driven pacemaker: rate modulation versus normal sinus rhythm--comparison during treadmill exercise.

The pacing rate response of a new acceleration driven pulse generator (SWING 100, SORIN BIOMEDICA) was compared with simultaneous normal sinus rhythm (NSR) during two different treadmill exercises. This pacemaker has a gravitational acceleration sensor able to discriminate between physical activities and vibrations. Six healthy volunteers (three male, three female; aged 21.7 +/- 4.3 years), with the pacemaker strapped to their right infraclavicular area, performed each test three times with different rise response curve (RRC) each time: fast, normal, and slow. The fall response curve used was the same as the rising one during each test. Pacing rates were recorded using the VEGA analyzer (SORIN BIOMEDICA) and compared with simultaneous NSR recorded by a 7-channel ECG recorder (MINGOGRAF 7, SIEMENS). During all tests immediate (within seconds) rapid increase in pacemaker rate was seen up to about 60 seconds, then a slower increase followed thereafter. The mean correlation between pacing rates and NSR during the Bruce tests were 0.7941 +/- 0.10, 0.8562 +/- 0.14, and 0.8292 +/- 0.07; during the discontinuous tests 0.7292 +/- 0.16, 0.7233 +/- 0.10, and 0.7480 +/- 0.11 for fast, normal, and slow RRC, respectively. Each 30 seconds, nonsignificant differences were present between pacing rate and NSR during all the discontinuous tests; similar responses were observed only during the first two stages of Bruce tests after which NSR was significantly higher than pacemaker rates. The speed of rise to upper rate was the main difference between the different programs (fast, normal, and slow). The discontinuous tests showed that the pacemaker responds more to speed than to grade.(ABSTRACT TRUNCATED AT 250 WORDS)

Acceleration↗