Search PubMed⌕ Search

Biomedical subjects

A Harf

Publications and source records attributed to A Harf.

At least 55 records · Page 3Linked to original sources

Effects of continuous negative airway pressure on lung volume and respiratory resistance.

This study was designed to determine the responses of lung volume and respiratory resistance (Rrs) to decreasing levels of continuous negative airway pressure (CNAP). Twenty normal subjects were studied in the basal state and under CNAP levels of -5, -10, and -15 hPa. Rrs was measured by the forced oscillation technique (4-32 Hz). End-expiratory lung volume (EELV) and tidal volume (VT) were measured by whole body plethysmography. Rrs was extrapolated to 0 Hz (R(0)) and estimated at 16 Hz (R(16)) by linear regression analysis of Rrs vs. frequency. Specific Rrs, SR(0) and SR(16), were then calculated as R(0) (EELV + VT/2) and R(16) (EELV + VT/2), respectively. EELV significantly decreased, whereas R(0), R(16), SR(0), and SR(16) significantly increased, as the CNAP level decreased (P < 0.0001 for all). At the lowest CNAP level, R(0) and R(16) reached 198 +/- 13 and 175 +/- 9% of their respective basal values. The CNAP-induced increase in R(0) was significantly higher than that in R(16) (P < 0.004). Our results demonstrate that the CNAP-induced increase in Rrs does not result from a direct lung volume effect only and strongly suggest the involvement of other factors affecting both intrathoracic and extrathoracic airway caliber.

Adult↗

Overexpression of alveolar macrophage gelatinase B (MMP-9) in patients with idiopathic pulmonary fibrosis: effects of steroid and immunosuppressive treatment.

Alveolar macrophages (AM) express gelatinase B, a member of the matrix metalloproteinase family involved in the degradation and remodeling of extracellular matrix components. We evaluated the expression of gelatinase B in the course of idiopathic pulmonary fibrosis (IPF) by studying alveolar macrophages in culture AM and bronchoalveolar lavage fluid from 12 untreated patients with IPF, 11 patients with IPF under treatment with steroid and immunosuppressive agents, and 10 control subjects. By using zymography and quantitative image analysis, latent gelatinase B, as well an 88-kD active form, were investigated in culture medium (24 h) of AMs and were found to be significantly increased (P < 0.01) in untreated patients exhibiting severe IPF when compared with control subjects (4.1 +/- 1.7 versus 0.3 +/- 0.2 10(5) arbitrary units [AU]/10(4) AM for the 92-kD form). Concomitant studies of gelatinase B levels associated with cultured AM extracts or freshly harvested AM showed similar results, both at the mRNA and protein levels, respectively. Immunocytochemical studies on freshly harvested AM demonstrated that the enzyme was located mainly at the cell, suggesting some involvement of gelatinase B in AM migration. In contrast, gelatinase B activity secreted by AM tended to be normal in patients with IPF under steroid and immunosuppressive treatment. Simultaneously, level of the gelatinase B activity in epithelial lining fluid was increased in untreated IPF patients, whereas it was normal in treated patients. These results suggest that AM of patients with IPF are primed for gelatinase B expression and that steroid and immunosuppressive treatment induces negative modulation of the gelatinase B overexpression. We conclude that gelatinase B may play a role in lung remodeling in IPF.

Base Sequence↗

Protruding the tongue improves posterior rhinomanometry in obstructive sleep apnoea syndrome.

In posterior rhinomanometry (PRM), oropharyngeal pressure is measured using a tube placed between the tongue and the hard palate. For valid results the patient must position the tongue and soft palate so that both the oropharynx and nasopharynx remain open. A high rate of failure of conventional PRM has been reported in normal individuals. In patients with obstructive sleep apnoea syndrome (OSAS), upper airway abnormalities may further increase the failure rate. This study proposes a modification of the technique in which protrusion of the tongue enhances pressure transmission between the nasopharynx and the mouth. In eight normal subjects, resistance was similar when measured by both methods. Of 24 OSAS patients, conventional PRM was unsuccessful in 11. In the remaining 13 patients, a significant correlation between the two methods was found, but resistance was lower by "tongue-out" than by conventional PRM, consistent with a decrease, during tongue protrusion, in retropalatal resistance, which is a component of the "nasal" resistance measured by PRM. In 26 OSAS patients, unilateral nasal resistance values measured by "tongue-out" PRM were similar to those measured by anterior rhinomanometry. When the "tongue-out" method was used routinely in 541 snorers, failure rates were 1.1% in the 272 non-OSAS patients and 3.7% in the 269 OSAS patients. These results indicate that posterior rhinomanometry with tongue protrusion is a highly effective tool for measuring nasal resistance in snorers.

Adolescent↗

Combined effects of a mechanical nasal dilator and a topical decongestant on nasal airflow resistance.

The goal of this study was to compare the isolated and combined effects of two treatments being used to reduce nasal airflow resistance (NR): an internal nasal mechanical dilator (Nozovent; Prevancure; Sté Pouret, Paris, France) and a topical decongestant, fenoxazoline hydrochloride (Aturgyl; Synthelabo; Le Plessis-Robinson, France). The study was performed in 17 healthy subjects. NR was estimated by active posterior rhinometry at a 0.5 L/s flow under four conditions: in the basal state, with the internal nasal mechanical dilator, after treatment with fenoxazoline hydrochloride, and with both fenoxazoline hydrochloride and the mechanical dilator. The mean NR (+/- SD) decreased from 1.65+/-0.54 cm H2O/L/s in the basal state to 1.02+/-0.27 cm H2O/L/s with the mechanical dilator (p < 0.001), 1.03+/-0.47 cm H2O/L/s with fenoxazoline hydrochloride (p < 0.001), and 0.48+/-0.15 cm H2O/L/s with both the mechanical dilator and fenoxazoline hydrochloride (p < 0.001). The decreases in NR observed after using either the mechanical dilator (deltaNR(N)) or fenoxazoline hydrochloride (deltaNR(A)) were not significantly different. The decrease in NR observed with both (deltaNR(N + A)) was not significantly different from the sum deltaNR(N) + deltaNR(A): 1.16+/-0.53 cm H2O/L/s vs 1.25+/-0.63 cm H2O/L/s, respectively (p > 0.05). deltaNR(N + A) strongly correlated with deltaNR(N) + deltaNR(A): deltaNR(N + A) = 0.80 (deltaNR(N) + deltaNR(A)) + 0.15 (r = 0.96; p < 0.0001). However, the slope of the regression line of deltaNR(N + A) vs deltaNR(N) + deltaNR(A) was significantly lower than unity (p < 0.003). These results demonstrate that, although not totally additive, the effects of using the mechanical dilator and fenoxazoline hydrochloride are cumulative. Further studies that include patients with nasal obstruction would allow us to better evaluate the benefit of a therapy combining both treatments.

Administration, Topical↗

Chest physiotherapy in cystic fibrosis: improved tolerance with nasal pressure support ventilation.

OBJECTIVE: Chest physiotherapy (CPT) is an integral part of the treatment of patients with cystic fibrosis (CF). CPT imposes additional respiratory work that may carry a risk of respiratory muscle fatigue. Inspiratory pressure support ventilation (PSV) is a new mode of ventilatory assistance designed to maintain a constant preset positive airway pressure during spontaneous inspiration with the goal of decreasing the patient's inspiratory work. The aim of our study was 1) to evaluate respiratory muscle fatigue and oxygen desaturation during CPT and 2) to determine whether noninvasive PSV can relieve these potential adverse effects of CPT. METHODS: Sixteen CF patients in stable condition with a mean age of 13 +/- 4 years participated to the study. For CPT, we used the forced expiratory technique (FET), which consisted of one or more slow active expirations starting near the total lung capacity (TLC) and ending near the residual volume. After each expiration, the child was asked to perform a slow, nonmaximal, diaphragmatic inspiration. After one to four forced breathing cycles, the child was asked to cough and to expectorate. A typical 20-minute CPT session consisted of 10 to 15 FET maneuvers separated by rest periods of 10 to 20 breathing cycles each. During the study, each patient received two CPT sessions in random order on two different days, at the same time of day, with the same physiotherapist. During one of these two sessions, PSV was provided throughout the session (PSV session) via a nasal mask using the pressure support generator ARM25 designed for acute patients (TAEMA, Antony, France). The control session was performed with no nasal mask or PSV. Both CPT sessions were performed without supplemental oxygen. Lung function and maximal inspiratory pressures (PImax) and expiratory pressures (PEmax) were recorded before and after each CPT session. RESULTS: Mean lung function parameters were comparable before the PSV and the control sessions. Baseline pulse oximetry (SpO2) was significantly correlated with the baseline vital capacity (% predicted) and forced expiratory volume in 1 second (FEV1) (% predicted). PSV was associated with an increase in tidal volume (Vt) from 0.42 +/- 0.01 liters to 1.0 +/- 0.02 liters. Respiratory rate was significantly lower during PSV. SpO2 between the FET maneuvers was significantly higher during PSV as compared with the control session. SpO2 decreases after FET were significantly larger during the control session (nadir: 91.8 +/- 0. 7%) than during the PSV session (93.8 +/- 0.6%). Maximal pressures decreased during the control session (from 71.9 +/- 6.1 to 60.9 +/- 5.3 cmH2O, and from 85.3 +/- 7.9 to 77.5 +/- 4.8 cmH2O, for PImax and PEmax, respectively) and increased during the PSV session (from 71.6 +/- 8.6 to 83.9 +/- 8.7 cmH2O, and from 80.4 +/- 7.8 to 88.0 +/- 7.4 cmH2O, for PImax and PEmax, respectively). The decrease in PEmax was significantly correlated with the severity of bronchial obstruction as evaluated based on baseline FEV1 (% predicted). Forced expiratory flows did not change after either CPT session. The amount of sputum expectorated was similar for the two CPT sessions (5.3 +/- 5.3 g vs 4.6 +/- 4.8 g after the control and PSV session, respectively; NS). Fifteen patients felt less tired after the PSV session. Ten patients reported that expectoration was easier with PSV, whereas 4 did not note any difference; 2 patients did not expectorate. Nine patients expressed a marked and 5 a small preference for PSV, and 2 patients had no preference. The physiotherapists found it easier to perform CPT with PSV in 14 patients and did not perceive any difference in 2 patients. DISCUSSION: Our study in CF children shows that respiratory muscle performance, as evaluated based on various parameters, decreased after CPT and that significant falls in oxygen saturation occurred after the FET maneuvers despite the quiet breathing periods between each FET cycle. These unwanted effects of CPT were

Adolescent↗

Positive pressure generation by pneumatic and electronic O2 regulators: a bench experimental evaluation.

BACKGROUND: The introduction of advanced anti-G protection into agile fast fighter aircraft may result in the regular use of positive pressure breathing (PPB) for G protection by aircrew. Since PPB results in an external additional work of breathing (WoB), we compared the mechanical performance of the pneumatic and electronic O2 regulators designed for "Mirage 2000" and "Rafale" aircraft. HYPOTHESIS: Since mask pressure is regulated by the electronic device in relation to flow, mask pressure will remain constant throughout the respiratory cycle, so that PPB-related additional WoB will be less with the electronic regulator. METHODS: In a bench dynamic study performed with a sinusoidal pump, we measured variations in mask pressure (deltaP) and calculated WoB at 0, 3 and 6 kPa of PPB (0, 30 and 60 cm H2O, respectively), for 0.5, 1 and 2 L of volume and for 10, 15 and 20 cycles per minute of respiratory rate. RESULTS: We found that, compared with the pneumatic device, inspiratory and expiratory WoB with the electronic device were respectively lower by approximately 25% (p < 0.05) and by approximately 10% (NS) at 3 and 6 kPa of PPB, for all respiratory conditions. Nevertheless, we also observed remaining variations in mask pressure with the electronic regulator, due to complex impedance of the inspiratory circuit, since the device uses the pressure measured into the regulator. CONCLUSIONS: We concluded that the electronic control of mask pressure is relatively efficient but that the device would be improved by placing the site of the pressure measurement into the mask.

Aerospace Medicine↗

Susceptibility to upper airway obstruction during partial neuromuscular block.

BACKGROUND: Airway obstruction after anesthesia may be caused or exaggerated by residual neuromuscular block, with loss of muscle support for collapsible upper airway structures. METHODS: Six male volunteers were studied before treatment, during stable partial neuromuscular block with vecuronium at a mean train-of-four (TOF) ratio of 50% (95% CI, 36-61%), and after reversal by neostigmine. Catheter-mounted transducers were placed in the pharynx and esophagus to estimate, respectively, the upper airway resistance, and the work of breathing (calculated as the time integral of the inspiratory pressure developed by the respiratory muscles, esophageal pressure time product) during quiet breathing, during breathing 5% carbon dioxide, and while breathing with an inspiratory resistor. Breathing with pressure at the airway opening held at pressures from -5 to 40 cm H2O were also tested to assess airway collapsibility. RESULTS: Although breathing through a resistor increased upper airway resistance from 1.2 (0.67, 1.72) cm H2O x l(-1) x s to 2.5 (1.32, 3.38) cm H2O x l(-1) x s, and carbon dioxide stimulation reduced resistance to 0.8 (0.46, 1.33) cm H2O x l(-1) x s, no effect of partial neuromuscular block (mean TOF ratio, 52%) on upper airway properties could be shown. CONCLUSIONS: Neuromuscular block with a TOF ratio of 50% can be present yet clinically difficult to detect in patients recovering from anesthesia. This degree of block has no effect on airway patency in volunteers, even during challenge. Airway obstruction during recovery from anesthesia thus is more likely to be caused by residual effects of general anesthetic agents or centrally acting analgesics, either alone or perhaps in concert with residual neuromuscular block.

Adult↗

Gravity effects on upper airway area and lung volumes during parabolic flight.

We measured upper airway caliber and lung volumes in six normal subjects in the sitting and supine positions during 20-s periods in normogravity, hypergravity [1.8 + head-to-foot acceleration (Gz)], and microgravity ( approximately 0 Gz) induced by parabolic flights. Airway caliber and lung volumes were inferred by the acoustic reflection method and inductance plethysmography, respectively. In subjects in the sitting position, an increase in gravity from 0 to 1. 8 +Gz was associated with increases in the calibers of the retrobasitongue and palatopharyngeal regions (+20 and +30%, respectively) and with a concomitant 0.5-liter increase in end-expiratory lung volume (functional residual capacity, FRC). In subjects in the supine position, no changes in the areas of these regions were observed, despite significant decreases in FRC from microgravity to normogravity (-0.6 liter) and from microgravity to hypergravity (-0.5 liter). Laryngeal narrowing also occurred in both positions (about -15%) when gravity increased from 0 to 1.8 +Gz. We concluded that variation in lung volume is insufficient to explain all upper airway caliber variation but that direct gravity effects on tissues surrounding the upper airway should be taken into account.

Adult↗

Heavy snoring with upper airway resistance syndrome may induce intrinsic positive end-expiratory pressure.

We studied eight heavy snorers with upper airway resistance syndrome to investigate potential effects of sleep on expiratory airway and lung resistance, intrinsic positive end-expiratory pressure, hyperinflation, and elastic inspiratory work of breathing (WOB). Wakefulness and non-rapid-eye-movement sleep with high- and with low-resistance inspiratory effort (H-RIE and L-RIE, respectively) were compared. No differences in breathing pattern were seen across the three conditions. In contrast, we found increases in expiratory airway and lung resistance during H-RIE compared with L-RIE and wakefulness (56 +/- 24, 16 +/- 4, and 11 +/- 4 cmH2O . 1(-1) . s, respectively), with attendant increases in intrinsic positive end-expiratory pressure (5.4 +/- 1.8, 1.4 +/- 0.5, and 1.3 +/- 1.3 cmH2O, respectively) and elastic WOB (6.1 +/- 2.2, 3.7 +/- 1.2, and 3.4 +/- 0.7 J/min, respectively). The increase in WOB during H-RIE is partly caused by the effects of dynamic pulmonary hyperinflation produced by the increased expiratory resistance. Contrary to the Starling model, a multiple-element compliance model that takes into account the heterogeneity of the pharynx may explain flow limitation during expiration.

Adult↗

Nonchemical influence of inspiratory pressure support on inspiratory activity in humans.

To determine whether nonchemical inhibition of respiratory activity occurs during inspiratory pressure support (IPS) ventilation (IPSV), respiratory motor output (in 9 subjects), obtained by calculating transdiaphragmatic pressure-time products, and central respiratory output (in 5 subjects), obtained by integrating the electromyographic activity of the diaphragm (EMGdi) during mechanical inspiratory time, EMGdi per minute, and electrical inspiratory time, as determined from onset to peak EMGdi, were compared during spontaneous ventilation (control) and IPSV with (IPS+CO2) and without (IPS) correction of hypocapnia. Both IPS and IPS+CO2 induced significant decreases in transdiaphragmatic pressure-time products (46 +/- 31 and 53 +/- 23%, respectively), EMGdi during mechanical inspiratory time (49 +/- 12 and 57 +/- 14%, respectively), EMGdi per minute (65 +/- 22 and 69 +/- 15%, respectively), and electrical inspiratory time (73 +/- 8 and 65 +/- 6%, respectively). Because correction of hypocapnia failed to eliminate the marked inhibition of both respiratory and central motor output seen with IPS, we conclude that nonchemical inhibition of respiratory activity occurs during IPSV.

Adult↗

Contribution of the endotracheal tube and the upper airway to breathing workload.

The influence of the endotracheal tube (ETT) during a T-piece trial remains controversial. Our aim was to compare the work of breathing of 14 successfully extubated patients at the end of a 2-h trial (T) and after extubation (E) of the trachea, and to assess, using the acoustic reflection method, the resistance of the endotracheal tube and of the supraglottic airway as well as their related work. We found that the work of breathing of the patients was identical between T and E (1.72 +/- 0.59 versus 1.63 +/- 0.45 J/L; p = 0.50 and 23.5 +/- 10.6 versus 22.6 +/- 9.7 J/min; p = 0.70). There was no significant difference between the beginning and the end of the T-piece trial (1.57 +/- 0.53 versus 1.72 +/- 0.59 J/ L, p = 0.10). The work caused by the ETT amounted to 11.0 +/- 3.9% of the total work of breathing. The supraglottic airway resistance was in the normal range and was significantly smaller than the endotracheal tube resistance (0.79 +/- 0.4 versus 1.43 +/- 0.31 cm H2O x s/L; p = 0.008, flow = 0.25 L/s). We conclude that a 2-h trial of spontaneous breathing through an endotracheal tube well mimics the work of breathing performed after extubation, in patients who pass a weaning trial and do not require reintubation.

Acoustics↗

Effects of flow triggering on breathing effort during partial ventilatory support.

The effects of flow triggering (FT) as compared with pressure triggering (PT) on breathing effort have been the focus of several studies, and discrepant results have been reported. In the initial part of our study, a lung model was used to quantify triggering effort (airway pressure-time product, PTPaw) for a range of sensitivity settings in nine new-generation ventilators. A ventilator providing both FT and PT was then used to compare these systems during pressure-support (PSV) and volume-targeted assist-control ventilation (ACV) in eight ventilator-dependent patients, using sensitivity settings (2 L/min for FT and -2 cm H2O for PT) that had proven significantly different in the initial bench study. Indexes of effort included the esophageal and transdiaphragmatic pressure-time products and inspiratory work of breathing per minute (PTPes/min, PTPdi/min, and Wi/min, respectively). The experimental study revealed significant differences between ventilators in PTPaw at commonly used settings. In two of three ventilators featuring both systems, PTPaw was significantly lower with FT than PT (p < 0.001). In the clinical study, FT as compared with PT, was associated with reductions in all indexes of breathing effort during PSV: 16 +/- 6% (p < 0.001), 13 +/- 10% (p < 0.01), and 14 +/- 12% (p < 0.05) for PTPdi/min, PTPes/min, and Wi/min, respectively. By contrast, no differences were found when FT was used during ACV. Although FT reduced triggering effort in both modes (p < 0.001), the effects observed during the post-trigger phase differed, and explained the discrepant results between the two modes. We conclude that FT more effectively reduces breathing effort when used in conjunction with a pressure-targeted mode than with a volume-targeted mode, especially when flow delivery is close to or below demand.

Aged↗

Respiratory resistive impedance as an index of airway obstruction during nasal continuous positive airway pressure titration.

Esophageal pressure amplitude (DeltaPes), inspiratory pulmonary resistance (RLI) and inspiratory flow limitation score (FS) are used as indices of upper airway obstruction for the titration of nasal continuous positive airway pressure (nCPAP) in patients with obstructive sleep apnea syndrome (OSAS). This study was designed to determine whether oscillatory respiratory resistive impedance at 16 Hz (RFO) might be proposed as an alternative index. Eleven OSAS patients were studied during a night of polysomnography-controlled nCPAP titration. Nasal flow (V) and airway opening and esophageal pressures (Pao and Pes, respectively) were continuously measured during nasal breathing, and forced-flow oscillations (FO) were applied for 5 min at each nCPAP level. RLI was calculated by linear regression analysis of resistive pressure versus V over inspiration. R FO was obtained by linear regression analysis of respiratory resistive impedance versus frequency. Application of FO affected neither sleep nor pulmonary mechanics. RFO correlated with RLI in all patients. RFO did not correlate with DeltaPes in two patients, and was not significantly related to FS in five patients. This study demonstrates the applicability of the FO technique in sleeping patients receiving nCPAP, and the reliability of RFO for assessing pulmonary resistance. RFO might therefore be proposed as a quantitative index of airway obstruction for nCPAP titration.

Aged↗

Protective effect of endotoxin instillation on subsequent bacteria-induced acute lung injury in rats.

The phagocytic capability afforded by neutrophil influx into the lungs is essential to ward off invading bacteria. The objective of this study was to evaluate the effect of prior neutrophil recruitment induced by alveolar instillation of endotoxin (LPS, 200 micrograms/kg) 16 h before a pulmonary infection caused by instillation of live Pseudomonas aeruginosa ([PYO]: 1.5 x 10(8) colony-forming units [cfu]/kg) in rats. A first series of experiments showed that lipopolysaccharide (LPS) instillation induced recruitment of alveolar neutrophils that were capable, ex vivo, of elastase exocytosis, reactive oxygen species secretion, and PYO killing. In a second set of experiments, LPS followed by PYO was compared with PYO alone (n = 11 surviving rats in each group). Parameters were studied 24 h after the bacterial challenge. As compared with PYO alone, pretreatment with LPS followed by PYO was associated with decreased mortality (0% versus 54%, p < 0.05), decreased protein leakage into bronchoalveolar lavage (BAL) fluid (1.8 +/- 0.4 versus 13.5 +/- 2.2 mg/ml, p < 0.001), and improved bacterial clearance from BAL (4.0 +/- 1.4 x 10(2) versus 1.2 +/- 0.5 x 10(4) cfu/ml, p < 0.05) and from pulmonary parenchyma (8.5 +/- 6.4 x 10(5) versus 1.9 +/- 0.8 x 10(7) cfu/ml, p < 0.05). We conclude that prior alveolar endotoxin instillation induces local recruitment of functionally active neutrophils, and that this is associated with resistance to subsequent experimental pneumonia.

Animals↗

Cell-matrix interactions modulate 92-kD gelatinase expression by human bronchial epithelial cells.

We have previously reported that primary human bronchial epithelial cells (HBECs) cultured on types I + III collagen were able to differentially regulate the production of major constitutive 92-kD gelatinase, minor 72-kD gelatinase, and their tissue-specific inhibitor, tissue inhibitor of metalloproteinase-1 (TIMP-1) in response to lipopolysaccharide (LPS) or proinflammatory cytokines, suggesting that HBECs may be involved in vivo in the active remodeling of the underlying extracellular matrix (ECM). In this study, we examined the possible effects of specific type IV collagen as compared with types I + III collagen on HBEC behavior and function. We investigated 92-kD gelatinase and TIMP-1 expression with zymography and reverse zymography, respectively, at the protein level, and with quantitative reverse transcription-polymerase chain reaction (RT-PCR) at the mRNA level. Results showed similar morphologic features and identical proliferation rates of HBECs in response to the two matrix substrates. Nevertheless, differences at the protein and mRNA levels between HBEC cultures on type IV collagen and on types I + III collagen included: (1) a lower basal level of 92-kD gelatinase production; (2) less upregulation of 92-kD gelatinase in response to LPS endotoxin or to the proinflammatory cytokines interleukin-1beta (IL-1beta) and tumor necrosis factor-alpha (TNF-alpha); and (3) loss of activation of the proforms of the 92-kD and 72-kD gelatinases. These findings, together with the maintenance of TIMP-1 expression, strongly suggest that type IV collagen used as a matrix substratum is associated with a homeostatic HBEC phenotype, and limits the ability of HBECs to degrade the matrix. In contrast, types I + III collagen may be associated with a matrix resorption phenotype corresponding to active matrix remodeling and repair. Thus, the ECM underlying HBECs may modulate matrix remodeling by HBECs, particularly in response to inflammatory processes during acute lung injury.

Bronchi↗

Expiratory valves used for home devices: experimental and clinical comparison.

A bench study followed by a clinical trial were performed to evaluate the mechanical characteristics of five (commercially available) expiratory valves used for home ventilators, as well as the potential clinical impact of differences between these valves. In the in vitro study, expiratory valve resistance was evaluated under unvarying conditions, whereas dynamic behaviour was evaluated by calculating the imposed expiratory work of breathing during a simulated breath generated by a lung model. Differences in resistance and imposed expiratory work of up to twofold and 150%, respectively, were found across valves. We then conducted a randomized crossover clinical study to compare the effects of the least resistive (Bennett) and most resistive expiratory valves (Peters) in 10 intubated patients receiving pressure support ventilation. There were no significant differences regarding blood gases or respiratory parameters except for the oesophageal pressure-time product (PTPoes), which was significantly increased by the Peters valve (236+/-113 cmH2O x s x min(-1) versus 194+/-90 cmH2O x s x min(-1)). An analysis of individual responses found that the Peters valve induced substantial increases in intrinsic positive end-expiratory pressure (PEEP), PTPoes, and expiratory activity in those patients with the greatest ventilatory demand. In conclusion, differences between home expiratory valve resistances may have a clinically relevant impact on the respiratory effort of patients with a high ventilatory demand.

Adult↗