Search PubMed⌕ Search

Biomedical subjects

A H Morris

Publications and source records attributed to A H Morris.

At least 37 records · Page 2Linked to original sources

Increased mortality of older patients with acute respiratory distress syndrome.

OBJECTIVE: To examine the relationship between age and mortality in ARDS patients and evaluate the importance of factors that increase the mortality of older ARDS patients. DESIGN: Prospective inception cohort study. SETTING: Community-based referral hospital. PATIENTS: Two hundred fifty-six ARDS patients identified from May 1987 to December 1990. ARDS was defined by the following: (1) PaO2/PAO2 < or = 0.2; (2) pulmonary capillary wedge pressure < or = 15 mm Hg; (3) total static thoracic compliance < or = 50 mL/cm H2O; (4) bilateral infiltrates on chest radiograph; and (5) an appropriate clinical setting for ARDS. MAIN OUTCOME MEASURES: Comparison of organ failure, incidence of sepsis, patient demographics, arterial oxygenation, and level of support in those 55 years and younger and those older than 55 years of age. Withdrawal of support in patients who died. RESULTS: Seventy-two of 112 patients older than 55 years (64%) died vs 65 of 144 patients 55 years and younger (45%) (p = 0.002). Examination of patient groups using age identified older than 55 years as a "cutpoint" above which mortality was greater (p = 0.002). Older nonsurvivors did not differ from nonsurvivors 55 years or younger with respect to gender, smoking history, ARDS risk factors, ARDS identifying characteristics, APACHE II (acute physiology and chronic health evaluation), number of organ failures, or the incidence of sepsis. In the 48 h prior to death, nonsurvivors 55 years and younger had more organ failure (3.4 +/- 0.2 vs 2.8 +/- 0.2; p = 0.03), higher fraction of inspired oxygen (0.82 +/- 0.03 vs 0.68 +/- 0.03; p = 0.008), and higher positive end-expiratory pressure levels (13 +/- 1 vs 8 +/- 1; p = 0.001) than older nonsurvivors. Despite more severe expression of disease, only 32 (50%) nonsurvivors 55 years and younger had support withdrawn. Significantly more nonsurvivors older than 55 years (73%) had support withdrawn (p = 0.009). Even in the absence of chronic disease states, withdrawal was more likely for patients older than 55 years (21/51) than in those 55 years and younger (3/32; p < 0.001). CONCLUSIONS: Mortality is significantly higher for patients with ARDS older than 55 years. Decisions to withdraw support are made more often in ARDS patients older than 55 years. These data suggest that age bias may influence decisions to withdraw support.

APACHE↗

Comparison of calculated and experimental NMR spectral broadening for lung tissue.

NMR lineshapes were calculated for a model of lung, and NMR proton spectra were measured for individual voxels in an excised inflated rat lung. NMR lines for parenchymal lung regions containing alveoli, alveolar ducts, and capillaries were calculated using a computer simulation of the NMR signal from a three-dimensional honeycomb-like structure, a collection of modified Wigner-Seitz cells. These cells were modified by rounding the corners and increasing the thickness of the boundaries to model various degrees of lung inflation and lung water. NMR lineshapes were also calculated for the central or nonparenchymal lung regions containing bronchi and large blood vessels. A comparison of theoretical lineshapes with those measured in individual voxels both in the parenchymal and in the central (largely nonparenchymal) regions in excised rat lungs at an inflation pressure of 30 cm of water shows excellent agreement. These results indicate that the NMR lineshape reflects the underlying lung geometry. This research constitutes the first calculations and measurements of NMR lineshapes in lung. The appendix describes a new method for calculating the magnetic field inside a weakly diamagnetic material of arbitrary shape placed in an otherwise uniform external magnetic field. This new method does not require either solution of simultaneous equations or evaluation of integral expressions.

Animals↗

Testing and validation of computerized decision support systems.

Systematic, through testing of decision support systems (DSSs) prior to release to general users is a critical aspect of high quality software design. Omission of this step may lead to the dangerous, and potentially fatal, condition of relying on a system with outputs of uncertain quality. Thorough testing requires a great deal of effort and is a difficult job because tools necessary to facilitate testing are not well developed. Testing is a job ill-suited to humans because it requires tireless attention to a large number of details. For these reasons, the majority of DSSs available are probably not well tested prior to release. We have successfully implemented a software design and testing plan which has helped us meet our goal of continuously improving the quality of our DSS software prior to release. While requiring large amounts of effort, we feel that the process of documenting and standardizing our testing methods are important steps toward meeting recognized national and international quality standards. Our testing methodology includes both functional and structural testing and requires input from all levels of development. Our system does not focus solely on meeting design requirements but also addresses the robustness of the system and the completeness of testing.

Artificial Intelligence↗

Standardization of clinical decision making for the conduct of credible clinical research in complicated medical environments.

The likelihood that past experience will produce correct guides to current practice depends on the signal-to-noise ratio for the clinical problem of interest. If the signal-to-noise ratio is high, the decision will be sound and patient benefit likely to occur. If the signal-to-noise ratio is low, as is commonly the case with difficult clinical decisions, then personal experience and the best intentions will not assure sound clinical decisions. When the probability of benefit cannot be quantified, clinicians in complex settings are in danger of being misled by data and experience. Quantifiable probabilities established by group experiment or observation will be necessary for clinical decisions that can be expected to confer benefit on the patient. Explicit methods are necessary for interventions that can be replicated in experiments or in practice. Computerized protocols force the articulation of explicit clinical care methods and standardize clinical decision making. We have developed explicit, rule-based protocols, implemented them in our hospital, exported them to other hospitals, and successfully achieved a rigorous experimental environment in the clinical ICU. Exportation of such explicit methods may narrow the gap between efficacy (university hospital) and effectiveness (community hospital) research results.

Clinical Trials as Topic↗

Lung water measurement by nuclear magnetic resonance: correlation with morphometry.

Estimates of lung water content obtained from nuclear magnetic resonance (NMR) and morphometric and gravimetric measurements were compared in normal and experimentally injured rats. Average lung water density (rho H2O) was measured by an NMR technique in excised unperfused rat lungs (20 normal lungs and 12 lungs with oleic acid-induced edema) at 0 (full passive deflation) and 30 cmH2O lung inflation pressure and in vivo (4 normal rats and 8 rats with lung injury induced by oleic acid or rapid saline infusion). The rho H2O values were compared with morphometric measurements of lung tissue volume density (Vv) obtained from the same lungs fixed at corresponding liquid-instillation pressures. A close correlation was observed between rho H2O and Vv in normal and injured excised lungs [correlation coefficient (r) = 0.910, P < 0.01]. In vivo rho H2O was also closely correlated with Vv (r = 0.897, P < 0.01). The correlation coefficients between rho H2O and gravimetric lung water content (LWGr) were lower in the excised lung group (r = 0.663 and 0.692, respectively, for rho H2O at 0 and 30 cmH2O lung inflation pressure, P < 0.01) than in the in vivo study (r = 0.857, P < 0.01). Our results indicate that NMR techniques, which are noninvasive and nondestructive, provide reliable estimates of lung water density and that the influence of lung inflation on rho H2O is important (compared with the effect of lung water accumulation in lung injury) only in the presence of deliberately induced very large variations in the lung inflation level.

Animals↗

Incidence of the adult respiratory distress syndrome in the state of Utah.

To determine the incidence of the adult respiratory distress syndrome (ARDS) in Utah, we prospectively screened intensive-care-unit (ICU) patients for ARDS in six of the 40 general acute-care hospitals in Utah. Over a 1-yr period, we diagnosed severe ARDS (oxygenation criterion: PaO2/PAO2 < or = 0.2) in 110 patients. Of these patients, 27 were not residents of Utah. We estimated that there were 58 undetected Utah residents with ARDS in the remaining 34 Utah acute-care hospitals. We also estimated that one Utah resident per year received ARDS care outside Utah. Incorporating these two estimates, we calculated an estimated upper limit for ARDS incidence in Utah of 8.3 ARDS patients per 100,000 total Utah population per year. Using only directly identified Utah residents with ARDS, we calculated the absolute lower limit for ARDS incidence in Utah to be 4.8 ARDS patients per 100,000 Utah population per year. The incidence of ARDS in Utah is about an order of magnitude less than the 1972 National Heart and Lung Institute Task Force estimate of ARDS incidence in the United States, but agrees with more recently published ARDS incidence figures.

Adult↗

Alveolar air/tissue interface and nuclear magnetic resonance behavior of normal and edematous lungs.

The alveolar air/tissue interface markedly affects the NMR properties of lungs by causing an NMR signal loss as a result of internal (tissue-induced) magnetic field inhomogeneity. The signal loss can be measured as the difference in NMR signal intensity (difference signal delta) between a pair of images obtained using temporally symmetric and asymmetric spin-echo sequences. Previous data indicate that the difference signal measured at an asymmetry time of 6 ms (delta 6ms) is very low in degassed lungs and increases markedly with alveolar opening. Theoretically, the NMR behavior of edematous lungs is expected to differ from that of normal nondegassed lungs because alveolar flooding and collapse are equivalent to partial (regional) degassing. To test this prediction, we measured delta 6ms in normal and edematous (oleic acid-injured) excised unperfused rat lungs at 5, 10, 20, 30, and 0 (full passive deflation) cm H2O inflation pressure (PL). Lung volume changes were estimated from NMR lung water density (pH2O) measurements. In normal lungs, delta 6ms did not vary with PL. In edematous lungs delta 6ms was, as predicted, significantly lower than normal at 5 and 10 cm H2O PL but rose markedly (to about normal) as PL was further increased. Upon subsequent deflation from 30 to 0 cm H2O PL, delta 6ms did not vary significantly or decreased. On the basis of our theoretical models, the data could be interpreted as reflecting the loss of alveolar air/tissue interface as a result of alveolar flooding and the relative contributions of airspace recruitment and distension to the lung volume changes. Histologic and morphometric data obtained from the same lungs supported this interpretation.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Computers in critical care.

This article reviews the current state-of-the-art and future applications of computers in critical care, with particular attention to ventilator and drug-delivery applications. Automated charting, alerts and alarms, and tools for decision support (such as expert systems and closed-loop control) are discussed also.

Computers↗

Verification & validation algorithms for data used in critical care decision support systems.

A decision support system is only as good as the data generating that decision support system. If the data is incorrect, doesn't relate to the other pieces of data, is missing or is not consistent, the decision support system conclusions may be incorrect and inconsistent. While collecting data from several sites during a multicenter randomized clinical trial, we found that some critical data elements were missing, out of correct ranges, totally illogical, and/or inconsistently recorded. In order to get consistent, correct, and dependable information from a our decision support system, the data elements used in that system had to be checked for completeness, valid values, consistent units of measurement, and relationships to other items. Development of data quality assurance rules and the application of those rules is imperative to using the data to generate daily scores for multiple organ failure, sepsis, and barotrauma.

Algorithms↗

Medical informatics academia and industry: a symbiotic relationship that may assure survival of both through health care reform.

There are often clear lines drawn identifying the demilitarized zone between medical informatics academics and industry. Academics were "pure" intellectuals sequestered in ivory towers that effectively shielded them from the realities of the world. Industry has historically focused on creating effective products that produce financial return to the corporation. Both the paradigms of academia and industry are quickly becoming dinosaurs in the era of health care reform where both medical informatics academia and industry are under increasing pressure to develop and prove that medical informatics has a positive impact on health care both in terms of the quality of care as well as cost. Unfortunately, neither academia or industry alone are going to be able to successfully complete this task. The purpose of this paper is to describe such a collaborative effort that has produced a computerized decision support system for the management of mechanical ventilation in patients with the Adult Respiratory Distress Syndrome (ARDS) that is now installed and supported on three different commercial CIS platforms. This collaborative effort has allowed us to successfully mount a large multi-center clinical trial designed to determine efficacy.

Clinical Protocols↗

A successful protocol for the use of pulse oximetry to classify arterial oxygenation into four fuzzy categories.

Pulse oximetry is widely used in critical care medicine to noninvasively estimate arterial hemoglobin oxygen saturation. Despite the obvious benefits of using pulse oximetry to detect life threatening desaturations, it is unknown how well pulse oximetry is able to predict the finer graduations of arterial oxygenation needed for clinical decision making. A computerized protocol was developed for the use of pulse oximetry to classify arterial oxygenation into four fuzzy categories and tested in a prospective clinical trial which compared the oxygenation category assigned by the protocol to one assigned by a respiratory therapist. In 3,742 classifications from 15 patients over a seven month period, the protocol showed 96% agreement with the therapists in the direction of therapy and 75% agreement with the oxygenation classes assigned by the therapists.

Clinical Protocols↗

Cost effective computerized decision support: tracking caregiver acceptance at the point of care.

We implemented a computerized decision support tool to standardize the administration of supplemental oxygen (O2) therapy in the acute care (non-ICU) hospital setting. Caregiver acceptance of the computerizeds oxygen therapy protocol (COTP) instructions was measured to determine the clinical performance of the computerized decision support tool. 49.6% of instructions generated were followed by the clinical caregiver, and 16.8% of instructions generated were explicitly acknowledged by the user through the COTP computer interface. Despite this low caregiver response rate, significant favorable changes in the administration of oxygen were observed. This paper is focused on the issues of general importance the caregiver response rate raises for the implementation and clinical use of computerized decision support tools, including: (1) limitations of the user interface and (2) inherent difficulty in changing long-standing practice patterns.

Attitude to Computers↗

Randomized clinical trial of pressure-controlled inverse ratio ventilation and extracorporeal CO2 removal for adult respiratory distress syndrome.

The impact of a new therapy that includes pressure-controlled inverse ratio ventilation followed by extracorporeal CO2 removal on the survival of patients with severe ARDS was evaluated in a randomized controlled clinical trial. Computerized protocols generated around-the-clock instructions for management of arterial oxygenation to assure equivalent intensity of care for patients randomized to the new therapy limb and those randomized to the control, mechanical ventilation limb. We randomized 40 patients with severe ARDS who met the ECMO entry criteria. The main outcome measure was survival at 30 days after randomization. Survival was not significantly different in the 19 mechanical ventilation (42%) and 21 new therapy (extracorporeal) (33%) patients (p = 0.8). All deaths occurred within 30 days of randomization. Overall patient survival was 38% (15 of 40) and was about four times that expected from historical data (p = 0.0002). Extracorporeal treatment group survival was not significantly different from other published survival rates after extracorporeal CO2 removal. Mechanical ventilation patient group survival was significantly higher than the 12% derived from published data (p = 0.0001). Protocols controlled care 86% of the time. Average PaO2 was 59 mm Hg in both treatment groups. Intensity of care required to maintain arterial oxygenation was similar in both groups (2.6 and 2.6 PEEP changes/day; 4.3 and 5.0 FIO2 changes/day). We conclude that there was no significant difference in survival between the mechanical ventilation and the extracorporeal CO2 removal groups. We do not recommend extracorporeal support as a therapy for ARDS. Extracorporeal support for ARDS should be restricted to controlled clinical trials.

Adult↗

Adult respiratory distress syndrome and new modes of mechanical ventilation: reducing the complications of high volume and high pressure.

Reported survival rates for severe adult respiratory distress syndrome (ARDS) patients vary from 9% to 84%. Animal study results have suggested that application of the high pressures needed to deliver commonly used tidal volumes (10 to 15 mL/kg) may induce an overexpansion of the remaining small fraction of compliant ARDS lung still capable of gas exchange. Conventional ventilatory therapy might thus superimpose an iatrogenic lung injury on the ARDS lung. These considerations have led to pressure-limited mechanical ventilation strategies, including pressure-controlled, inverse-ratio ventilation. Caution should be exercised, however, since there are no convincing data that any particular ventilatory support mode is superior for the support of ARDS patients. Well-controlled, randomized clinical trials are needed. Because of the phenomenon of information input overload, it seems reasonable to question our ability to come to the "right therapeutic decision" when dealing with multivariate problems in severely ill patients. Since ARDS patients provide clinicians with complicated, multifactorially determined problems, the identification of patient outcome changes due to specific interventions (e.g., a new mechanical ventilation mode) is difficult. Computerized protocols eliminate unnecessary variation in clinical care. They standardize clinical care and impose control on the clinical care process. By standardizing therapy, protocols may significantly reduce the random and nonrandom noise (bias) introduced into the clinical environment by clinical care team members. This is especially important fo the many pertinent clinical questions addressed by clinical trials that cannot be double blinded. Conclusions from protocol-controlled clinical trials should be more credible and more likely to lead to action than those of the past.

Animals↗

Ethical implications of standardization of ICU care with computerized protocols.

Ethical issues related to the use of computerized protocols to control mechanical ventilation of patients with Acute Respiratory Distress Syndrome (ARDS) are identical to the ethical issues surrounding the use of any therapy or intervention. Four ethical principles must be considered: nonmaleficence, beneficence, autonomy, and distributed justice. The major ethical challenges to computerized protocol use as a specific application of clinical decision support tools are found within the principles of nonmaleficence and of beneficence. The absence of credible outcome data on which ARDS patient survival probabilities with different therapeutic options could be based is a constraint common to most ICU clinical decision making. Clinicians are thus deprived of the knowledge necessary to define benefit and are limited to beneficent intention in clinical decisions. Computerized protocol controlled decision making for the clinical management of mechanical ventilation for ARDS patients is ethically defensible. It is as well supported as most ICU therapy options.

Clinical Protocols↗

Guidelines for privileges in arthroscopic surgery.

This report sets forth flexible guidelines to be used by hospitals or surgery centers to define privileges in arthroscopic surgery. The Arthroscopy Association of North America recognizes that the completion of a residency program, fellowship training, or hands-on workshop does not, per se, guarantee competence in arthroscopic surgery. The demonstration of an applicant's technical and motor skills by direct observation is a vital component of the credentialing process. Threshold criteria of state licensure, completion of surgical residency training, documentation of prior experience, and existing orthopaedic surgical privileges are defined. Levels of complexity of arthroscopic procedures are divided as basic and advanced.

Arthroscopy↗