Search PubMed⌕ Search

Biomedical subjects

A H Maitz

Publications and source records attributed to A H Maitz.

22 records · Page 2Linked to original sources

Treatment planning for gamma knife radiosurgery with multiple isocenters.

Many arteriovenous malformations and tumors suitable for radiosurgical treatment have non-spherical or irregular shapes. Forty-eight percent of the first 156 patients treated with the gamma unit at the University of Pittsburgh required treatment with two or more isocenters to optimize dose distributions. Dose distributions for combining gamma knife treatments to two or more isocenters were systematically investigated. High speed computerized dosimetry was performed using specially developed software and dose distributions were confirmed with film densitometry. We have developed guidelines for treatment to two or more isocenters which help reduce treatment planning time, and facilitate selection of treatment doses and optimum dose distributions. These guidelines include maintaining an account of the distances between all isocenters, using a catalogue of sample two-isocenter isodose plans, comparing dose volume histograms, and calculating complication probabilities using the integrated logistic formula.

Cobalt Radioisotopes↗

Physics of gamma knife approach on convergent beams in stereotactic radiosurgery.

The Presbyterian-University Hospital of Pittsburgh installed the first clinically designated Leksell gamma knife in the U.S. in August 1987. Gamma knife radiosurgery involves stereotactic target localization with the Leksell frame and subsequent closed-skull single-treatment session irradiation of a lesion with multiple highly focused gamma ray beams produced from 60Co sources. The hemispherical array of sources, the large number of small-diameter beams, and the steep dose gradients surrounding a targeted lesion make physical characterization of the radiation field complex. This paper describes the physical features and the operation of the gamma knife as well as the calibration procedures of the very small, well-collimated beams. The results of studies using in-phantom ion chamber, diode, film, and lithium fluoride thermoluminescent dosimetry were all in close agreement. Both single-beam and multiple-beam dose profiles were measured and reported for the interchangeable helmets, which have 4-, 8-, 14-, and 18-mm-diameter collimators. We also describe the dose calculation and treatment planning algorithm in the treatment planning system. Measurements of the accuracy of mechanical and radiation alignment are also performed and discussed.

Brain Diseases↗