Search PubMedSearch

Biomedical subjects

A H Lovick

Publications and source records attributed to A H Lovick.

6 recordsLinked to original sources

Blood flow in portal systems with special reference to the rat pituitary gland.

Regional pituitary blood flow has been studied in adult female Fischer 344 rats by [14C]iodoantipyrine autoradiography. A general mathematical solution has been derived to allow the calculation of blood flow in the second compartment of a portal system and the proportion of blood "shunted" through the first compartment without exposure to tissue uptake from a knowledge of (a) the volume ratios of the two compartments, (b) the tissue tracer uptakes of the two compartments, and (c) the arterial tracer concentration with respect to time of a freely diffusible tracer. Significant diffusion limitation and/or arteriovenous shunting has been demonstrated in the neurohypophysis, suggesting that the majority of incoming blood is "shunted" unchanged to the adenohypophysis. The mean value of the shunt is 89% (range of 84-93%) for the median eminence and lies between 72% (range of 52-82%) and 73% (range of 59-81%) for the posterior pituitary. Neurohypophysial flow rates of 1.20 (range of 0.99-1.55) ml g-1 min-1 for the median eminence and 1.68 (range of 0.83-3.53) ml g-1 min-1 for the posterior pituitary were measured. These values represent "tissue-available" (nonshunted) flow; estimated mean total (shunted plus nonshunted) neurohypophysial flow rates were 11.7 (range of 9.5-17.5) ml g-1 min-1 for the median eminence and 6.1 (range of 3.1-8.9) ml g-1 min-1 (minimum) for the posterior pituitary. Adenohypophysial blood flow is heterogeneous. In the long portal territory, the flow rate was 1.18 (range of 0.95-1.75) ml g-1 min-1 but short portal territory flow calculation is complicated by an unquantifiable nonportal venous drainage; using the natural limits of zero and 100% gives a minimum adenohypophysial flow rate of 1.42 (range of 0.76-2.07) ml g-1 min-1 and a maximum value of 1.97 (range of 1.03-2.82) ml g-1 min-1.

Algorithms

Experimental aspects of cerebrospinal hemodynamics: the relationship between blood flow velocity waveform and cerebral autoregulation.

The dynamic relationships among mean flow velocity, its pulsatile amplitude (FVa), cortical cerebral blood flow (CBF), and cerebral perfusion pressure (CPP) were studied in normal rabbits and rabbits with subarachnoid hemorrhage using 8-MHz pulsed transcranial Doppler ultrasound and hydrogen clearance under conditions of systemic hypotension and intracranial hypertension. A two-slope relationship was observed between FVa and CPP with a break point that correlated closely with the lower limit of CBF autoregulation in each animal. Below this CPP break point, FVa varied directly with CPP, and above the break point FVa varied inversely with CPP. In this experimental model, an inverse correlation between FVa and CPP indicates intact CBF autoregulation, whereas loss of that correlation implies exhaustion of autoregulatory reserve. Simultaneous recording and computation of FVa, CPP, and the correlation coefficient between FVa and CPP may be a means of monitoring CBF autoregulation in clinical practice.

Animals

A modification of the method for the measurement of cerebral blood flow using [14C]iodoantipyrine in small animals.

We have modified the method for the measurement of cerebral blood flow using [14C]iodoantipyrine in small animals to overcome problems caused by rapid sequential arterial sampling. A second isotope, gamma-emitting [99mTc]pertechnetate, is infused together with [14C]iodoantipyrine. The 99mTc is counted externally by a detector placed over the chest. The arterial curve for [14C]iodoantipyrine can be reconstructed from a single arterial sample collected from the severed neck and the shape of the 99mTc chest curve. Because of the short half-life of 99mTc (6 h), all 14C measurements, including preparation of autoradiograms, may be made 3 days later.

Animals

Changes in cerebral blood flow during anaesthesia and surgery in the sitting position.

Serial measurements of global cerebral blood flow (CBF) were made in 15 patients undergoing elective neurosurgical procedures in the sitting position, using a modified intravenous 133Xenon technique. The mean supine CBF rose from 43 (+/-3) ml/100g/min to 62 (+/-6) ml/100g/min in the sitting position and remained elevated at the end of surgery at 62 (+/-5) ml/100g/min. Both increases in CBF were statistically significant with respect to baseline supine values.

Adult

Low-cost microcomputer-based densitometer.

We have constructed low-cost equipment for the measurement of the optical density of x-ray films. This equipment is based on a video system connected via an analog to digital converter to an Apple microcomputer. The optical density of an x-ray film can thus be accessed by commands in BASIC or machine-code programs. By using a calibrated step-wedge film, we have found a stable linear response for optical densities of up to 0.8.

Computers