Search PubMed⌕ Search

Biomedical subjects

A Gayot

Publications and source records attributed to A Gayot.

12 recordsLinked to original sources

Relation between structural characteristics of talc and its properties as an antisticking agent in the production of tablets.

Antisticking power varies according to the talc considered. Besides its chemical properties, it is necessary to assess its physical properties related to functionality. It is difficult to define the physical properties of talc implicated in its antisticking power. In this work, different talcs were characterised and their performance in reducing sticking in tablet manufacturing was evaluated. The following parameters were studied: apparent density, morphogranulometry, roughness, and the specific surface through the adsorption-desorption of argon. Next, the relationship between the characteristics of talcs and their antisticking power was considered. Talc before and after delamination-which is a way to obtain talcs with different physical characteristics-was compared. Antisticking power appeared to be dependent on the basal dimensions of talc, and on the ratio value of the external specific surface measured by diffractometry to the total specific surface by the BET method. Models to express the effect of textural factors of talc particles on antisticking power were defined.

Absorption↗

Developing a study method for producing 400 microm spheroids.

The aim of this work was to obtain 400 microm spheroids that can be sprinkled on food to improve patient compliance particularly in the case of children and old people. A methodology to select wet masses for extrusion-spheronization through a 400 microm orifice was developed. The first step was to define the parameters that make it possible to assess the qualities required by the wet mass and the extrudates and evaluation norms: plasticity, cohesiveness, brittleness of the mass and the extrudates, and appearance of extrudates. A feasibility assay was then performed on the cylinder extruder, showing that extrusion of the lactose/Avicel PH 101/water (50/50/60) mass is not feasible through the 400 microm orifice. Precirol ato 5 and Gelucire 50/02 wetted with a sodium lauryl sulfate solution at 0.5% show plastic flow through the 400 microm diameter orifice. The presence of Avicel PH 101 does not improve plasticity for this orifice. Micropellets of 400 microm have been proved feasible as long as excipients with suitable pharmaceutical technological properties are used. After proving the feasibility of 400 microm spheroids of Gelucire 50/02, we considered the association of a drug with it.

Cellulose↗

Study of the technological parameters of ultrasonic nebulization.

The principle of an ultrasonic nebulizer is based on the vibrations of a piezoelectric crystal driven by an alternating electrical field. These periodic vibrations are characterized by their frequency, their amplitude, and their intensity, which corresponds to the energy transmitted per surface unit. When the vibration in tensity is sufficient, cavitation occurs, and droplets are generated. Ventilation enables airflow to cross the nebulizer and to expel the aerosol droplets. For a given nebulizer, the vibration frequency of the piezoelectric crystal is fixed, often in the range 1-2.5MHz. In most cases, an adjustment in vibration intensity is possible by modifying vibration amplitude. The ventilation level is adjustable. The vibrations may be transmitted through a coupling liquid--commonly water--to a nebulizer cup containing the solution to be aerosolized. In this work, we studied the influence of the technological parameters of ultrasonic nebulization on nebulization quality. Our study was carried out with a 9% sodium chloride solution and a 2% protein solution (alpha1 protease inhibitor). Three different ultrasonic nebulizers were used. An increase in vibration frequency decreased the size of droplets emitted. The coupling liquid absorbed the energy produced by the ultrasonic vibrations and canceled out any heating of the solution, which is particularly interesting for thermosensitive drugs. An increase in vibration intensity did not modify the size of droplets emitted, but decreased nebulization time and raised the quantity of protein nebulized, thus improving performance. On the other hand, an increase in ventilation increased the size of emitted droplets and decreased nebulization time and the quantity of protein nebulized because more drug was lost on the walls of the nebulizer. High intensity associated with low ventilation favors drug delivery deep into the lungs.

Algorithms↗

[Feasibility of 400 microm spheroids by extrusion-spheronization].

Extrusion-spheronisation technology is an agglomeration process that makes it possible to obtain spheroids. The aim of this work was to obtain 400microm spheroids that could be sprinkled on food to improve patient observance in particular with children and old people. A methodology to select wet masses for extrusion-spheronisation through a 400microm orifice was developed. First, it was nesessary to define the parameters that make it possible to appreciate the qualities that the wet mass and the extrudates have to possess and their method of evaluation: plasticity, cohesiveness, brittleness of the mass and the extrudates, appearance of extrudates. A feasibility assay made on the drum extruder was then performed. After proving the feasibility of 400microm spheroids of Gelucire 50/02 we considered the association of a drug with it.

Drug Compounding↗

Influence of the technological parameters of ultrasonic nebulisation on the nebulisation quality of alpha1 protease inhibitor (alpha1PI).

The principle of an ultrasonic nebuliser is based on the vibrations of a piezo-electric crystal driven by an alternating electrical field. These periodical vibrations are characterised by their frequency, their amplitude and their intensity which corresponds to the energy transmitted per surface unit. When the vibration intensity is sufficient, cavitation appears and generates droplets. Ventilation enables an airflow to cross the nebuliser and to expulse the aerosol droplets. For a given nebuliser, the vibration frequency of the piezo-electric crystal is fixed and is often in the range of 1-2.5 MHz. In most cases, an adjustment in vibration intensity is possible by modifying vibration amplitude. The ventilation level is adjustable. The influence of these two parameters on the efficiency of ultrasonic nebulisation is studied. The study was carried out with a protein solution that had to be administered into the lungs. The solution used presented a viscosity of 1.25 mPa and a surface tension of 53 mN/m. The integrity of the protein was checked which was submitted to different vibration conditions. Nebulisation efficiency was evaluated by determining droplet size, the percentage of drug nebulised and nebulisation time. An increase in vibration intensity does not modify the size of droplets emitted, but decreases nebulisation time and raises the quantity of protein nebulised, thus improving performance. On the other hand, an increase in ventilation increases the size of droplets emitted, decreases nebulisation time and the quantity of protein nebulised because more drug is lost on the walls of the nebuliser. High intensity associated with low ventilation favours drug delivery deep into the lungs.

Aerosols↗

Influence of formulation on jet nebulisation quality of alpha 1 protease inhibitor.

As foam appears during solution constitution and nebulisation of alpha 1 protease inhibitor (alpha 1 PI), we selected in a previous work, antifoams likely to be associated with an alpha 1 PI solution to be nebulised: span 65 at a 0.025% concentration and cetyl alcohol at a 0.05% concentration associated with tyloxapol at 0.025% concentration. The purpose of this study was, on the one hand to study the influence of the formulation on nebulisation quality by relating physicochemical properties and nebulisation capacity, and on the other hand, to define the alpha 1 PI that will be retained for a clinical study. The properties of the different alpha 1 PI formulations are compared: surface tension, viscosity, time required to constitute the protein solution and pH. Nebulisation quality is evaluated under different operating conditions by measuring the droplet size, the quantity of alpha 1 PI nebulised, nebulisation time and the quantity of alpha 1 PI likely to reach the lungs which was subjected to statistical analysis. The statistical analysis of results indicates that the addition of the cetyl alcohol/tyloxapol mixture improves nebulisation effectiveness by significantly increasing the quantity of drug nebulised and therefore the quantity of alpha PI likely to reach the lungs. It is this formulation that will be retained for clinical trials. We check that the nebuliser and operating conditions influence all the parameters, that is to say the respirable fraction, the quantity nebulised and the nebulisation time. Although there is no interaction between the nebuliser and the formulation, nebulisation quality is the combined result of the formulation, the nebuliser and the operating conditions.

Antifoaming Agents↗

[Bioadhesive polymers].

Explore the source record for details and available documents.

Biocompatible Materials↗