Microcoil nuclear magnetic resonance spectroscopy.

In comparison with most analytical chemistry techniques, nuclear magnetic resonance has an intrinsically low sensitivity, and many potential applications are therefore precluded by the limited available quantity of certain types of sample. In recent years, there has been a trend, both commercial and academic, towards miniaturization of the receiver coil in order to increase the mass sensitivity of NMR measurements. These small coils have also proved very useful in coupling NMR detection with commonly used microseparation techniques. A further development enabled by small detectors is parallel data acquisition from many samples simultaneously, made possible by incorporating multiple receiver coils into a single NMR probehead. This review article summarizes recent developments and applications of "microcoil" NMR spectroscopy.

Miniaturization↗

Nuclear magnetic resonance coupled microseparations.

The increased separation efficiency afforded by reducing the size of the separation column has resulted in 'microseparations' becoming an important component in many chemical and biochemical applications. The coupling of microseparations with NMR detection is an area of increasing interest owing to the high structural information of NMR. In order to couple efficiently with the separation, the NMR detector must be reduced in size to correspond to that of the separation peak. This paper summarizes some of the approaches used in coupling NMR detection with pressure-driven and electrophoretic microseparations, the design of small NMR detectors and applications of this technology.

Amino Acids↗

23Na microscopy of the mouse heart in vivo using density-weighted chemical shift imaging.

The mouse has become an important animal model for human cardiac disease, and the development of techniques for non-invasive imaging of the mouse heart in vivo is, therefore, of great potential interest. Previous magnetic resonance imaging studies have concentrated on pathologically induced changes in cardiac structure and dynamics by acquiring proton images. Further information can be gained by studying cardiac function and physiology using other nuclei, for example, sodium. Sodium imaging of such a small structure presents considerable technical challenges. In this work we show the first sodium images of the mouse heart, with an isotropic spatial resolution of 1 x 1 x 1 mm, acquired in a time of 1.5 h. The ventricles, septum and myocardium are readily distinguishable in these images, which were acquired through the combination of 3D density-weighted chemical shift imaging, optimized instrumentation, and a high magnetic field strength (17.6 T). Measurements of the myocardial:blood sodium concentration in the left and right ventricles agree well with theoretical values.

Animals↗

An eight-coil high-frequency probehead design for high-throughput nuclear magnetic resonance spectroscopy.

In order to increase the throughput of high-resolution nuclear magnetic resonance spectroscopy a multiple-coil probe, which enables the simultaneous analysis of eight different samples, was designed. The probe, consisting of eight identical solenoidal coils, was constructed for operation at 600 MHz. By using four receivers and radiofrequency switches, spectra from eight different chemical solutions were acquired in the time normally required for one. Two-dimensional COSY, gradient COSY, and TOCSY data have been acquired. Intercoil electrical isolation was between 25 and 45 dB, with signal cross-talk between approximately 1 and 5% measured by NMR. The spectral linewidths for the eight coils were between 3 and 6Hz for a single optimized shim setting.

Equipment Design↗

Union of capillary high-performance liquid chromatography and microcoil nuclear magnetic resonance spectroscopy applied to the separation and identification of terpenoids.

This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-microm diameter C18 HPLC column is linked to a 500 MHz 1H-NMR microcoil probe with an observe volume of 1.1 microl. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha-pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-flow NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR.

Chromatography, High Pressure Liquid↗

Apparent diffusion tensor measurements in myelin-deficient rat spinal cords.

The apparent diffusion tensor (ADT) was measured in excised and fixed spinal cords from myelin-deficient (md) rats and age-matched controls. These data were used to obtain the principal diffusivities of the ADT, and also the scalar invariant parameters _D (averaged principal diffusivity) and A(sigma) (anisotropy index) for four white matter and two gray matter regions. The results for white matter regions showed that the principal diffusivities were significantly higher for md animals, and while the _D was increased in tissue from md animals, the A(sigma) was found to be decreased. Grey matter _D was measured to be between those of white matter from control and md animals, and the A(sigma) was much smaller than that of white matter from both sets of animals, indicating that diffusion in md white matter is more anisotropic than in gray matter. The results show that while myelination is not a prerequisite for diffusion anisotropy, it does influence the magnitude of the observed anisotropy. Magn Reson Med 45:191-195, 2001.

Animals↗

Magnetic resonance microscopy of morphological alterations in mouse trabecular bone structure under conditions of simulated microgravity.

This work describes the use of magnetic resonance (MR) microscopy to examine changes in tibial trabecular bone structure in mice following 28 days of hindlimb suspension, a model simulating the effects of microgravity in rodents. In this first MR study involving mice, analysis of 3D images showed that apparent bone volume fraction, trabecular number, and trabecular thickness were decreased, and apparent trabecular spacing increased, significantly (P < 0.05) in hindlimb-suspended mice compared to controls. These changes agreed well with light microscopy measurements from an independent study and also with actual spaceflight experiments with rats.

Animals↗

Unifying linear prior-information-driven methods for accelerated image acquisition.

In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework provides a conceptual link that facilitates comparison among these methods to reveal their strengths and weaknesses. By considering the limitations of existing methods, a new member in this class of methods was developed. The broad-use linear acquisition speed-up technique (BLAST) uses the estimated amount of change within the FOV as prior information. BLAST has the flexibility of incorporating a variable amount of prior information to avoid the misleading appearance of "phantom features," which arise from overconstraining the reconstruction. Examples from dynamic imaging and MR thermometry are shown.

Body Temperature↗

MR microscopy of multicomponent diffusion in single neurons.

This study examines multicomponent diffusion in isolated single neurons and discusses the implications of the results for macroscopic water diffusion in tissues. L7 Aplysia neurons were isolated and analyzed using a 600 MHz Bruker wide-bore instrument with a magnetic susceptibility-matched radiofrequency microcoil. Using a biexponential fit, the apparent diffusion coefficients (ADCs) from the cytoplasm (with relative fraction) were 0.48 +/- 0.14 x 10(-3) mm2 x s(-1) (61 +/- 11%) for the fast component, and 0.034 +/- 0.017 x 10(-3) mm2 x s(-1) (32 +/- 11%) for the slow component (N = 10). Diffusion in the nucleus appears to be primarily monoexponential, but with biexponential analysis it yields 1.31 +/- 0.32 x 10(-3) mm2 x s(-1) (89 +/- 6%) for the fast component and 0.057 +/- 0.073 x 10(-3) mm2 x s(-1) (11 +/- 6%) for the slow (N = 5). The slow component in the nucleus may be explained by cytoplasmic volume averaging. These data demonstrate that water diffusion in the cytoplasm of isolated single Aplysia neurons supports a multiexponential model. The ADCs are consistent with previous measurements in the cytoplasm of single neurons and with the slow ADC measurement in perfused brain slices. These distributions may explain the multiple compartments observed in tissues, greatly aiding the development of quantitative models of MRI in whole tissues.

Animals↗

A probe design for the acquisition of homonuclear, heteronuclear, and inverse detected NMR spectra from multiple samples.

A new probe design is presented for obtaining homonuclear, heteronuclear, and inverse detected NMR spectra from more than one sample in the same total data acquisition time as for a single sample, thus increasing data acquisition efficiency. Specifically, a two-coil system, with each solenoidal coil impedance matched to 50 Omega at both proton and nitrogen frequencies, has been designed for operation at 11.7 T with an observe volume of 15 microL for each coil. Isolation between the two frequencies for each individual coil, and at each frequency between coils, was greater than 30 dB. Two-dimensional COSY and HMQC spectra were obtained with negligible NMR cross-talk between the two coils.

Adenosine Triphosphate↗

IL-12 treatment of endogenously arising murine brain tumors.

A number of recent studies have indicated that T cells can be stimulated to attack transplanted brain tumors in rodent models. As IL-12 has been shown to activate cytotoxic T cell responses, we tested the idea that it might stimulate a T cell response against endogenous brain tumors that arise in SV40 large T Ag transgenic mice (SV11). SV11 mice develop tumors of the choroid plexus, a specialization of the ependymal lining of the brain ventricles. They are a particularly relevant model of human disease, because they are immunocompetent but immunologically tolerant of the tumors. SV11 mice were treated with recombinant murine IL-12 for 10 days. Tumors grew more slowly than in control treated mice, and in some cases were reduced in size, as assessed by magnetic resonance imaging before and after treatment. At the end of treatment, tumors, but not brain parenchyma, exhibited extensive infiltration of activated CD8(+) and CD4(+) T cells. Tumors also showed a reduction in vascular density. Mice treated with IL-12 lived significantly longer than control mice. Tumors that progressed were nearly devoid of T cells, indicating that the T cell response was not sustained. In addition, some mice that had a substantial tumor burden at the beginning of treatment displayed evidence of immunosuppression, which might be related to TGF-ss2 detected in tumors. We conclude that IL-12 treatment can initiate an anti-tumor response even against endogenously arising brain tumors, but factors that will allow a sustained and more effective anti-tumor response need to be determined.

Animals↗

Monitoring temperature changes in capillary electrophoresis with nanoliter-volume NMR thermometry.

Nanoliter-volume proton nuclear magnetic resonance (NMR) spectroscopy is used to monitor the electrolyte temperature during capillary electrophoresis (CE). By measuring the shift in the proton resonance frequency of the water signal, the intracapillary temperature can be recorded noninvasively with subsecond temporal resolution and spatial resolution on the order of 1 mm. Thermal changes of more than 65 degrees C are observed under both equilibrium and nonequilibrium conditions for typical CE separation conditions. Several capillary and buffer combinations are examined with external cooling by both liquid and air convection. Additionally, NMR thermometry allows nonequilibrium temperatures in analyte bands to be monitored during a separation. As one example, a plug of 1 mM NaCl is injected into a capillary filled with 50 mM borate buffer. Upon reaching the NMR detector, the temperature in the NaCl band is more than 20 degrees C higher than the temperature in the surrounding buffer. Such observations have direct applicability to a variety of studies, including experiments which utilize sample stacking and isotachophoresis.

Electrophoresis, Capillary↗

NMR spectroscopy of single neurons.

The first spatially localized NMR spectra of osmolytes and metabolites from single isolated neurons have been obtained using a combination of high magnetic field strengths and NMR radio frequency (RF) microcoils. The proton spectra display peaks at high concentrations (100-300 mM) assigned to betaine and choline, and other metabolite resonances including lactate at lower concentrations in the order of 10s of millimoles. The volumes examined were approximately 10 nl, over two orders of magnitude less than previously possible. In these initial experiments; the cells were unperfused and the signal intensities of the osmolytes decrease with time, a phenomenon consistent with cell swelling. This work demonstrates the technical feasibility of NMR spectroscopy of single cells, further broadening the scope of NMR spectroscopy of living tissues from application to entire living organisms (man and animal models) and isolated tissues (perfused organs and cultured assemblies of cells) and now to single cells. Magn Reson Med 44:19-22, 2000.

Acetates↗

A microcoil NMR probe for coupling microscale HPLC with on-line NMR spectroscopy.

An HPLC NMR system is presented that integrates a commercial microbore HPLC system using a 0.5-mm column with a 500-MHz proton NMR spectrometer using a custom NMR probe with an observe volume of 1.1 microL and a coil fill factor of 68%. Careful attention to capillary connections and NMR flow cell design allows on-line NMR detection with no significant loss in separation efficiency when compared with a UV chromatogram. HPLC NMR is performed on mixtures of amino acids and small peptides with analyte injection amounts as small as 750 ng; the separations are accomplished in less than 10 min and individual NMR spectra are acquired with 12 s time resolution. Stopped-flow NMR is achieved by diversion of the chromatographic flow after observation of the beginning of the analyte band within the NMR flow cell. Isolation of the compound of interest within the NMR detection cell allows multidimensional experiments to be performed. A stopped-flow COSY spectrum of the peptide Phe-Ala is acquired in 3.5 h with an injected amount of 5 micrograms.

Amino Acids↗

Multiple solenoidal microcoil probes for high-sensitivity, high-throughput nuclear magnetic resonance spectroscopy.

Two designs for incorporating multiple solenoidal microcoils into a single probe head are presented to increase the throughput of high-resolution NMR. Through a combination of radio frequency switches and low-noise amplifiers, multiple NMR spectra can be acquired in the same time as a single spectrum from a conventional probe consisting of one coil. Since this method does not compromise sensitivity with regard to the individual microcoils, throughput increases linearly with the number of coils. Only one receiver is needed, and data acquisition parameters can be optimized for each sample. Specifically, a four-coil system has been implemented for proton NMR at 250 MHz using a wide-bore magnet, with an observe volume of 28 nL for each microcoil. Signal cross-contamination was approximately 0.2% between individual coils, and simultaneous one- and two-dimensional spectra have been obtained from samples of fructose, galactose, adenosine triphosphate, and chloroquine (7 nmol of each compound). A more compact two-coil configuration has also been designed for operation at 500 MHz, with observe volumes of 5 and 31 nL for the two coils. One- and two-dimensional spectra were acquired from samples of 1-butanol (55 nmol) and ethylbenzene (250 nmol).

Image Processing, Computer-Assisted↗

Nanoliter-volume 1H NMR detection using periodic stopped-flow capillary electrophoresis.

Recent advances in the analysis of nanoliter volumes using 1H NMR microcoils have led to the application of microcoils as detectors for capillary electrophoresis (CE). Custom NMR probes consisting of 1-mm-long solenoidal microcoils are fabricated from 50-micron diameter wire wrapped around capillaries to create nanoliter-volume detection cells. For geometries in which the capillary and static magnetic field are not parallel, the electrophoretic current induces a magnetic field gradient which degrades the spectroscopic information obtainable from CE/NMR. To reduce this effect and allow longer analyte observation times, the electrophoretic voltage is periodically interrupted so that 1-min high-resolution NMR spectra are obtained for every 15 s of applied voltage. The limits of detection (LODs; based on S/N = 3) for CE/NMR for arginine are 57 ng (330 pmol; 31 mM) and for triethylamine (TEA) are 9 ng (88 pmol; 11 mM). Field-amplified stacking is used for sample preconcentration. As one example, a 290-nL injection of a mixture of arginine and TEA both at 50 mM (15 nmol of each injected) is stacked severalfold for improved concentration LODs while achieving a separation efficiency greater than 50,000. Dissolving a sample in a mixture of 10% H2O/90% D2O allows H2O to serve as the nearly ideal neutral tracer and allows direct observation of the parabolic and flat flow profiles associated with gravimetric and electrokinetic injection, respectively. The unique capabilities of CE and the rich spectral information provided by NMR spectroscopy combine to yield a valuable analytical tool, especially in the study of mass-limited samples.

Arginine↗