Search PubMed⌕ Search

Biomedical subjects

A G Rosenberg

Publications and source records attributed to A G Rosenberg.

At least 19 recordsLinked to original sources

Long-term followup of the Miller-Galante total knee replacement.

One hundred seventy-two consecutive cemented Miller-Galante-I total knee arthroplasties in 155 patients were compared with 109 consecutive cemented Miller-Galante-II total knee arthroplasties in 92 patients. The average followup was 11 years (range, 8-15 years) and 9 years (range, 8-10 years), respectively. Of the 172 Miller-Galante-I arthroplasties, there have been 21 revisions; 15 patellar revisions; two included femoral revisions attributable to abrasion. Six additional well-fixed femoral and tibial components were revised: two for early instability, one for pain, one for periprosthetic fracture, and two for infection. No component had aseptic loosening or osteolysis. Using revision or loosening of any components as the end point, the Kaplan-Meier 10-year survivorship was 84.1% +/- 4.1%. Of the 109 Miller-Galante-II arthroplasties, there have been no component revisions, no aseptic loosening, and no osteolysis. Using revision or loosening of any components as the end point, the Kaplan-Meier 10-year survivorship was 100%. The Miller-Galante knee systems showed excellent fixation with no loosening and no osteolysis at as many as 15 years. Additionally, there have been no component revisions for late instability at as many as 15 years. Finally, the high prevalence of patellofemoral complications with the Miller-Galante-I design has been obviated with the Miller-Galante-II design.

Adult↗

Problems with cementless total knee arthroplasty at 11 years followup.

One hundred two patients with 131 consecutive cementless total knee arthroplasties that retained the posterior cruciate ligament were followed up prospectively. The average age of the patients was 58 years (range, 32-75 years). The mean followup on the surviving knee arthroplasties was 11 years (range, 7-16 years). The patellar component was metal-backed in the first 112 (85%) knees, cementless all-polyethylene in the last 17 (13%) knees, and two knees had a prior patellectomy. Forty-four metal-backed patellar components (48%) were revised; nine were loose, and 35 had polyethylene wear through. Thirteen femoral components (12%) were revised because of femoral abrasion from a failed metal-backed patellar component. No other femoral component was revised, loose, or had osteolysis develop. Nine (8%) tibial components had failure of ingrowth; eight have been revised. Partial radiolucencies occurred in 53% of the tibias. Thirteen (12%) small osteolytic lesions developed, all around screws or screw holes in the tibial components. At an average of 11 years followup, cementless fixation yielded mixed results: cementless femoral fixation was excellent and metal-backed patellar components had a 48% patellar revision rate. Cementless tibial components had an 8% aseptic loosening rate and a 12% incidence of small osteolytic lesions. Based on these results, the authors have abandoned cementless fixation in total knee arthroplasty.

Adult↗

Gout-induced arthropathy after total knee arthroplasty: a report of two cases.

Gout, although relatively rare in joint replacements, can present as an acute or chronic painful knee or hip arthroplasty. Gout and acute infection of a joint replacement can be difficult to differentiate, with the physical examination and laboratory study results frequently being similar. Both conditions can present with a rapid onset of joint pain, swelling, erythema, and constitutional symptoms, including fevers and malaise. Laboratory findings in both conditions often include an elevated leukocyte count, erythrocyte sedimentation rate, and C-reactive protein level. Negatively birefringent, needle-shaped crystals in the synovial fluid confirm the diagnosis of gout. The mistaken diagnosis of septic arthritis in a joint replacement with crystal-induced synovitis can lead to inappropriate open debridement or component removal. The current study includes a review of the literature and presents two cases of gout after total knee arthroplasty. These cases suggest that in situations of suspected sepsis without synovial fluid crystals, operative intervention is indicated with a presumed diagnosis of septic arthritis. The identification of chalky white or yellow deposits in the synovium or bone is highly suggestive of gout. The definitive diagnosis is made by polarized light histologic evaluation of these tissues. If these deposits are present in the absence of a positive preoperative culture, positive Gram stain for bacteria, or component loosening, component retention is indicated.

Aged↗

Primary repair of intraoperative disruption of the medical collateral ligament during total knee arthroplasty.

BACKGROUND: Intraoperative disruption of the medial collateral ligament during total knee arthroplasty is an uncommon complication that is frequently treated by implanting a prosthesis with varus-valgus constraint. To our knowledge, no data have been published on primary repair or reattachment of the medial collateral ligament and implantation of a minimally constrained posterior-stabilized or cruciate-retaining prosthesis. This retrospective study evaluates the hypothesis that satisfactory clinical results, at a minimum of two years, can be achieved with immediate repair or reattachment of the medial collateral ligament and without a constrained total knee prosthesis. METHODS: Of 600 knees treated with primary total knee arthroplasty, sixteen (in fourteen patients) sustained either a midsubstance disruption of the medial collateral ligament or an avulsion of the ligament from bone during the procedure. Preoperatively, all patients had either neutral or varus alignment and an intact medial collateral ligament. Midsubstance tears were treated with direct primary repair, and avulsions of the ligament off the tibia or femur were treated with suture-anchor reattachment to bone. All patients wore a hinged knee brace, with no limit to the range of motion, for six weeks postoperatively. Clinical and radiographic data were gathered prospectively as part of a database that was ongoing throughout the period of study; the cohort of patients was assembled retrospectively by searching that database. RESULTS: No patients were lost to follow-up. The mean duration of follow-up was forty-five months (range, twenty-four to ninety-five months). The Hospital for Special Surgery knee scores increased from a mean of 47 points (poor) preoperatively to a mean of 93 points (excellent) at the time of final follow-up. On physical examination, no patient had a Hospital for Special Surgery score in the fair or poor range and all patients had regained normal stability in the coronal plane both at full extension and at 30 degrees of flexion. No patient required knee-bracing beyond the initial six-week postoperative period. The range of motion at the time of final follow-up averaged 108 degrees (range, 85 degrees to 125 degrees ), although one knee required manipulation under anesthesia to obtain a satisfactory range of motion. No arthroplasties required revision. Radiographic examination demonstrated appropriate limb alignment in all patients at the time of final follow-up. CONCLUSIONS: Intraoperative disruption of the medial collateral ligament can be treated with primary repair or reattachment of the ligament to bone and postoperative bracing with good results; this avoids the potential disadvantages associated with the use of varus-valgus constrained implants.

Aged↗

Cementless acetabular reconstruction after acetabular fracture.

BACKGROUND: Total hip arthroplasty in patients with posttraumatic arthritis has produced results inferior to those in patients with nontraumatic arthritis. The use of cementless acetabular reconstruction, however, has not been extensively studied in this clinical context. Our purpose was to compare the intermediate-term results of total hip arthroplasty with a cementless acetabular component in patients with posttraumatic arthritis with those of the same procedure in patients with nontraumatic arthritis. We also compared the results of arthroplasty in patients who had had prior operative treatment of their acetabular fracture with those in patients who had had prior closed treatment of their acetabular fracture. METHODS: Thirty total hip arthroplasties were performed with use of a cementless hemispheric, fiber-metal-mesh-coated acetabular component for the treatment of posttraumatic osteoarthritis after acetabular fracture. The median interval between the fracture and the arthroplasty was thirty-seven months (range, eight to 444 months). The average age at the time of the arthroplasty was fifty-one years (range, twenty-six to eighty-six years), and the average duration of follow-up was sixty-three months (range, twenty-four to 140 months). Fifteen patients had had prior open reduction and internal fixation of their acetabular fracture (open-reduction group), and fifteen patients had had closed treatment of the acetabular fracture (closed-treatment group). The results of these thirty hip reconstructions were compared with the intermediate-term results of 204 consecutive primary total hip arthroplasties with cementless acetabular reconstruction in patients with nontraumatic arthritis. RESULTS: Operative time (p < 0.001), blood loss (p < 0.001), and perioperative transfusion requirements (p < 0.001) were greater in the patients with posttraumatic arthritis than they were in the patients with nontraumatic arthritis. Of the patients with posttraumatic arthritis, those who had had open reduction and internal fixation of their acetabular fracture had a significantly longer index procedure (p = 0.01), greater blood loss (p = 0.008), and a higher transfusion requirement (p = 0.049) than those in whom the fracture had been treated by closed methods. Eight of the fifteen patients with a previous open reduction and internal fixation required an elevated acetabular liner compared with one of the fifteen patients who had been treated by closed means (p = 0.005). Two of the fifteen patients with a previous open reduction and internal fixation required bone-grafting of acetabular defects compared with seven of the fifteen patients treated by closed means (p = 0.04). The thirty patients treated for posttraumatic arthritis had an average preoperative Harris hip score of 41 points, which increased to 88 points at the time of follow-up; there was no significant difference between the open-reduction and closed-treatment groups (p = 0.39). Twenty-seven patients (90%) had a good or excellent result. There were no dislocations or deep infections. The Kaplan-Meier ten-year survival rate, with revision or radiographic loosening as the end point, was 97%. These results were similar to those of the patients who underwent primary total hip arthroplasty for nontraumatic arthritis. CONCLUSIONS: The intermediate-term clinical results of total hip arthroplasty with cementless acetabular reconstruction for posttraumatic osteoarthritis after acetabular fracture were similar to those after the same procedure for nontraumatic arthritis, regardless of whether the acetabular fracture had been internally fixed initially. However, total hip arthroplasty after acetabular fracture was a longer procedure with greater blood loss, especially in patients with previous open reduction and internal fixation. Previous open reduction and internal fixation predisposed the hip to more intraoperative instability but less bone deficiency.

Acetabulum↗

Posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis.

BACKGROUND: Although initial reports on posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis have been encouraging, a high rate of late instability necessitating revision has been reported recently. The purpose of the present prospective study was to analyze the results of posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis. METHODS: Seventy-two posterior cruciate ligament-retaining total knee arthroplasties in fifty-one patients with rheumatoid arthritis were studied prospectively. All procedures were performed with the Miller-Galante I prosthesis. Eighteen patients (twenty-four knees) died before the eight-year follow-up and one patient (two knees) was lost to follow-up, leaving forty-six knees (thirty-two patients) for review. These forty-six knees were evaluated clinically (with particular attention to posterior instability) and radiographically at annual intervals for a mean of 10.5 years (range, eight to fourteen years). RESULTS: Forty-four (95%) of forty-six knees had a good or excellent result at a mean of 10.5 years. However, nine (13%) of the original seventy-two knees had revision of the implant, with six of the revisions performed because of failure of a metal-backed patellar component. The rate of survival at ten years was 93% 4% with femoral or tibial revision for any reason as the end point and 81% 5% with any reoperation as the end point. There was no aseptic loosening in any knee. Posterior instability was identified clinically and/or radiographically in two (2.8%) of the original seventy-two knees; both unstable knees were in the same patient. CONCLUSION: Posterior cruciate ligament-retaining total knee arthroplasty yielded satisfactory clinical and radiographic results in patients with rheumatoid arthritis at intermediate-term follow-up (mean, 10.5 years). Therefore, we believe that it remains an excellent treatment option for these patients.

Adult↗

Use of fibrin sealant to reduce bloody drainage and hemoglobin loss after total knee arthroplasty: a brief note on a randomized prospective trial.

BACKGROUND: A phase-III trial that included fifty-three patients undergoing unilateral primary total knee arthroplasty with cement was conducted to investigate the hemostatic efficacy of fibrin sealant. METHODS: Following cementing of the joint, 10 mL of fibrin sealant was sprayed onto the wound before tourniquet deflation and wound closure. No placebo was used in the control group. All patients received drains. RESULTS: Within twelve hours after the surgery, the amount of bloody drainage was 184.5 +/- 28.9 mL (mean and standard error) in the fibrin-sealant group (information available for twenty-three patients) and 408.3 +/- 54.6 mL in the control group (information available for twenty-three patients) (p = 0.002, after adjustment for variance in the time that the drainage was measured). On the first postoperative day, the hemoglobin level had decreased by 20.1 +/- 2.1 g/L in the fibrin-sealant group (information available for twenty-two patients) and by 27.3 +/- 2.1 g/L in the control group (information available for twenty-four patients). After adjustment for baseline values, the decrease in the hemoglobin level was 28.9% less in the fibrin-sealant group than in the control group (p = 0.005, 95% confidence limits = 10.2, 43.7). There were no seroconversions in the fibrin-sealant group. CONCLUSION: These results suggest that fibrin sealant can safely reduce bloody drainage following total knee arthroplasty while maintaining higher hemoglobin levels.

Arthroplasty, Replacement, Knee↗

Second-generation cementless total hip arthroplasty. Eight to eleven-year results.

BACKGROUND: Second-generation cementless femoral components were designed to provide more reliable ingrowth and to limit distal osteolysis by incorporating circumferential proximal ingrowth surfaces. We examined the eight to eleven-year results of total hip arthroplasty with a cementless, anatomically designed femoral component and a cementless hemispheric acetabular component. METHODS: Ninety-two consecutive primary total hip arthroplasties with implantation of a femoral component with a circumferential proximal porous coating (Anatomic Hip) and a cementless hemispheric porous-coated acetabular component (Harris-Galante II) were performed in eighty-five patients. These patients were prospectively followed clinically and radiographically. Six patients (seven hips) died and five patients (seven hips) were lost to follow-up, leaving seventy-four patients (seventy-eight hips) who had been followed for a mean of ten years (range, eight to eleven years). The mean age at the time of the arthroplasty was fifty-two years. RESULTS: The mean preoperative Harris hip score of 51 points improved to 94 points at the time of final follow-up; 86% of the hips had a good or excellent result. Thigh pain was reported as mild to severe after seven hip arthroplasties. No femoral component was revised for any reason, and none were loose radiographically at the time of the last follow-up. Two hips underwent acetabular revision (one because of dislocation and one because of loosening). Kaplan-Meier survivorship analysis was performed with revision or loosening of any component as the end point. The ten-year survival rate was 96.4% +/- 2.1% for the total hip prosthesis, 100% for the femoral component, and 96.4% +/- 2.1% for the acetabular component. Radiolucencies adjacent to the nonporous portion of the femoral component were seen in sixty-eight (93%) of the -seventy-three hips with complete radiographic follow-up. Femoral osteolysis proximal to the lesser trochanter was noted in four hips (5%). No osteolysis was identified distal to the lesser trochanter. Periacetabular osteolysis was identified in twelve hips (16%). Five patients underwent exchange of the acetabular liner because of polyethylene wear. CONCLUSIONS: This second-generation cementless, anatomically designed femoral component provided excellent clinical and radiographic results with a 100% survival rate at ten years. The circumferential porous coating of this implant improved ingrowth and prevented distal osteolysis at a mean of ten years after the arthroplasty.

Acetabulum↗

Cancellous allograft in revision total hip arthroplasty. A clinical review.

There are numerous indications for the use of cancellous allograft bone in the context of revision hip arthroplasty. These indications range from the well-documented use of morselized bone chips to fill cavitary defects during cementless acetabular reconstructions--in which complete or near-complete graft remodeling is expected--to the use of particulate allografting with bipolar hemiarthroplasty for acetabular revision, which largely has been abandoned because of frequent component migration, graft resorption, and clinical failure. Most other indications, including femoral and acetabular impaction allografting techniques, curettage of osteolytic defects with component retention, and complex reconstructions using acetabular reconstruction rings or cages with cancellous donor bone, are controversial but are supported by published clinical series. The current study reviews the literature on cancellous allografting in revision total hip arthroplasty.

Acetabulum↗

Hybrid total hip arthroplasty with a precoated offset stem. Four to nine-year results.

BACKGROUND: Use of modern cementing techniques for fixation of femoral components in total hip arthroplasty has had excellent clinical and radiographic results in most patients. However, several authors have described early loosening of femoral components with roughened and precoated finishes. The purpose of this study was to examine the performance of the precoated Iowa stem, which has increased offset, and to compare the results with those of another cemented precoated femoral component with standard offset used at our institution. METHODS: We carried out a prospective analysis of 102 primary hybrid total hip arthroplasties (a cementless acetabular component and a cemented femoral component) performed with use of the Iowa femoral component in ninety-five patients at our institution. The Iowa stem was used in hips that required greater offset than is available with standard stems as determined by preoperative templating. The average age of the patients at the time of the index procedure was sixty-nine years. Sixteen patients (seventeen hips) died before the forty-eight-month minimum follow-up period had elapsed. Two patients were lost to follow-up, and radiographic follow-up was incomplete for one. The mean duration of clinical and radiographic follow-up of the remaining eighty-two hips in the seventy-six surviving patients was sixty-five months (range, forty-eight to 104 months). RESULTS: The average preoperative Harris hip score of 47 points (range, 16 to 69 points) improved to an average of 87 points (range, 24 to 100 points) at the time of the review. Two hips underwent femoral component revision. Four femoral stems were radiographically loose at an average of thirty-four months. Femoral osteolysis was seen in five hips (6 percent) at an average of fifty-four months postoperatively. No acetabular component was revised because of aseptic loosening. According to Kaplan-Meier analysis, the seven-year survival rate, with an end point of femoral revision, osteolysis, or stem debonding, was 90.6 percent (95 percent confidence interval, 0.87 to 0.94). CONCLUSIONS: The prevalence of revision, osteolysis, and loosening after total hip arthroplasty with the Iowa femoral component at our institution was higher than that seen in our series of Harris Precoat stems, which had a survival rate of 98.4 percent (95 percent confidence interval, 0.97 to 1.00) at ten years with the same end points. The design of the Iowa stem may make it difficult to achieve a good cement mantle, and, in combination with the geometry and increased offset of the stem, may compromise the long-term survival of this cemented femoral component.

Acetabulum↗

Impaction allografting with cement for revision of the femoral component. A minimum four-year follow-up study with use of a precoated femoral stem.

BACKGROUND: Cancellous impaction allografting with cement for revision of the femoral component has conventionally been performed with a polished, tapered implant, which was designed to allow subsidence of the component. However, subsidence has been associated with pain in the thigh, dislocation of the hip, and revision of the component. This prospective study tested the hypothesis that good clinical results can be achieved--without subsidence of the component--with use of impaction allografting and a precoated, collared, straight stem for difficult femoral revisions. METHODS: Twenty-nine patients had revision of the femoral component with use of impaction allografting with cement and a Harris Precoat stem. Impaction allografting was performed when loss of metaphyseal and diaphyseal bone precluded revision with more straightforward techniques or when reconstitution of bone was considered a specific goal of the reconstruction (as was sometimes the case with revision of the component in younger patients). The patients were followed prospectively and were evaluated with use of the Harris hip score and serial radiographs. The patients were followed for a minimum of four years (mean, sixty-three months), except for four who died. RESULTS: Four patients died before the minimum four-year follow-up period had elapsed; all four had the prosthesis in place at the time of death. The Harris hip scores improved from a preoperative mean of 54 points (poor) (range, 21 to 91 points) to a mean of 87 points (good) (range, 41 to 100 points) at the time of the most recent follow-up. Kaplan-Meier survivorship analysis, with aseptic loosening as the end point, was 92 percent (95 percent confidence interval, 82 to 100 percent) at six years; one additional hip failed because of a hematogenous infection at seventy-three months postoperatively, for an overall failure rate of 12 percent (three of twenty-five patients) at the time of the most recent follow-up. Two hips needed a repeat revision; one was revised because of subsidence of the stem with recurrent osteolysis and the other, in a patient who had hemodialysis, because of late sepsis. A third femoral component subsided and failed but was not revised. Radiographic evidence of bone-stock reconstitution was observed in six (29 percent) of the twenty-one patients for whom radiographs were available. As in other series of patients managed with impaction allografting, the complication rate was high; excluding the revisions, three reoperations were performed, and six patients had either intraoperative femoral fracture or perforation necessitating cerclage wiring or cortical strut allografting and cerclage wiring at the time of the procedure. There were six nonunions in eighteen patients who had been operated on with a transtrochanteric approach. CONCLUSIONS: Difficult revisions of the femoral component with use of impaction allografting and a precoated stem provided satisfactory clinical and radiographic results at the time of intermediate-term follow-up. However, the high rate of complications in our series led us to refine our indications for the procedure.

Adult↗

High rate of failure of allograft reconstruction of the extensor mechanism after total knee arthroplasty.

BACKGROUND: Disruption of the extensor mechanism is an uncommon but devastating complication of total knee arthroplasty. Several techniques for reconstruction of the extensor mechanism after total knee arthroplasty have been reported, but we do not know of any study in which the results of one group's method were corroborated by a second group using the same technique. In the present series, we evaluated the results of reconstruction of the extensor mechanism with use of allograft according to the method described by Emerson et al. METHODS: Seven reconstructions of the extensor mechanism with use of a bone-tendon-bone allograft were performed with the technique of Emerson et al. in six patients. The patients were evaluated before and after the operation. The knee score according to the system of The Hospital for Special Surgery, evidence of an extensor lag, use of walking aids, and the ambulatory status of each patient were recorded. The patients were also asked about, and the medical records were reviewed for, episodes of falling related to weakness of the quadriceps after the reconstruction. The mean duration of follow-up was thirty-nine months (range, six to 115 months). As these reconstructions often fail early, the minimum duration of follow-up was six months. RESULTS: All seven reconstructions were rated as clinical failures on the basis of a persistent or recurrent extensor lag of more than 30 degrees. All but one patient needed an assistive device full time for walking, and four patients (five knees) had at least one documented episode of falling that was due to giving-way of the affected knee. Four of the reconstructions were revised; one revision was performed with use of another extensor mechanism allograft and three were performed with use of a medial gastrocnemius rotation flap. The other three clinical failures had not been revised at the time of writing. At the time of the most recent follow-up (or at the time of revision of the extensor reconstruction), the mean extensor lag was 59 degrees and the mean knee score was 52 points (a poor result). CONCLUSIONS: Undertensioning of the allograft reconstruction at the time of the operation and attenuation of the allograft both may have played a role in the inability of the patients to regain active extension of the knee postoperatively. Alternative techniques for reconstruction of the extensor mechanism or modifications of this technique should be considered in the treatment of this difficult problem.

Accidental Falls↗

The fate of stable cemented acetabular components retained during revision of a femoral component of a total hip arthroplasty.

BACKGROUND: The decision as to whether to revise or retain a well fixed cemented acetabular component during revision of a femoral component is especially difficult; the rate of loosening of cemented acetabular components is high, whereas that of porous-coated acetabular components inserted during revision is low. However, removal of a well fixed cemented acetabular component can result in increased operative morbidity and cost and in loss of acetabular bone. Data that can be used to predict the long-term survival of retained well fixed cemented acetabular components are therefore needed. METHODS: We studied the five to thirteen-year clinical and radiographic results in a group of twenty-six consecutive patients in whom a well fixed cemented acetabular component had been retained during revision of a femoral component. Typical demographic data on the patients and information about the components were recorded, and the cemented acetabular components were graded as A through F, according to the system of Ranawat et al., at the time of the femoral revision. The average duration of follow-up was 8.4 years (range, 5.0 to 12.7 years). No patient was lost to follow-up. RESULTS: Four acetabular components (15 percent) had progressive radiolucency (at forty-eight, forty-eight, fifty-nine, and seventy-five months after the femoral revision) and were considered radiographically loose despite not being associated with symptoms. All four components were graded as either E or F at the time that they were retained during the femoral revision; radiographic loosening was significantly related to these two grades (p < 0.01). No acetabular component with a grade of A, B, C, or D loosened. The components that loosened had been in vivo for a relatively shorter, as opposed to longer, duration before the femoral revision compared with the components that did not loosen (p < 0.05). CONCLUSIONS: Retention of the well fixed cemented acetabular components was associated with good clinical results but with a 15 percent rate of loosening. Revision of a cemented acetabular component solely on the basis of the duration that it was in vivo or whether a previous revision had been done does not appear to be warranted. Our findings suggest that acetabular components with a grade of A, B, C, or D at the time of a femoral revision may be retained, as these components continued to function at the time of the five to thirteen-year follow-up in the current study.

Acetabulum↗