Search PubMed⌕ Search

Biomedical subjects

A G Peele

Publications and source records attributed to A G Peele.

6 recordsLinked to original sources

Fresnel coherent diffractive imaging.

We present an x-ray coherent diffractive imaging experiment utilizing a nonplanar incident wave and demonstrate success by reconstructing a nonperiodic gold sample at 24 nm resolution. Favorable effects of the curved beam illumination are identified.

Journal Article↗

Diffraction with wavefront curvature: a path to unique phase recovery.

Modern X-ray optics is able to produce very tightly focused beams. The size of these focused spots is comparable to the scale of large molecules and therefore to the lattice spacing of crystals of these molecules. In this case, the phase of the illuminating beam may vary on the scale of the lattice and conventional diffraction theory needs to be modified. In this paper, coherent diffraction by non-planar beams is considered and it is shown that it is possible to uniquely recover the phase of the diffraction pattern.

Algorithms↗

Synchrotron beam coherence: a spatially resolved measurement.

We report a precise and spatially resolved measurement of the complex degree of coherence of a one-dimensional 1.5-keV beam produced by a third-generation synchrotron source. The method of phase-space tomography is used, which requires only measurements of the x-ray intensity. We find that the field is statistically stationary to within experimental error, the correlations are very well approximated by a Gaussian distribution, and the measured coherence length is in excellent agreement with expectations.

Journal Article↗

Unique phase recovery for nonperiodic objects.

It is well known that the loss of phase information at detection means that a diffraction pattern may be consistent with a multitude of physically different structures. This Letter shows that it is possible to perform unique structural determination in the absence of a priori information using x-ray fields with phase curvature. We argue that significant phase curvature is already available using modern x-ray optics and we demonstrate an algorithm that allows the phase to be recovered uniquely and reliably.

Algorithms↗

Measurement of the spatial coherence function of undulator radiation using a phase mask.

A measurement of the horizontal coherence function of 7.9 keV radiation from an undulator beam line at the Advanced Photon Source is reported. X-ray diffraction from a phase-shifting mask was used, and the coherence function was measured as a function of the width of beam-conditioning slits in the beam line. The coherence distribution is found to be best described by a Lorentzian function.

Journal Article↗