Search PubMed⌕ Search

Biomedical subjects

A G Davies

Publications and source records attributed to A G Davies.

At least 19 recordsLinked to original sources

The analysis of human cortical bone by terahertz time-domain spectroscopy.

Samples of cortical bone, derived from human femur, have been studied using terahertz time-domain transmission spectroscopy. The relationship between the broadband THz parameters and the previously acquired values of Young's modulus and x-ray attenuation (CT number), and the density of each bone sample, is investigated. The only significant correlation is that between THz transmission and sample density, suggesting that the potential use of THz radiation as a non-invasive probe of bone quality is limited. The spectra of absorption coefficient and refractive index are plotted over the frequency range 0.1-1.25 THz. There is evidence that the sample hydration state is a factor in the resultant THz parameters.

Bone Density↗

Linewidth and tuning characteristics of terahertz quantum cascade lasers.

We have measured the spectral linewidths of three continuous-wave quantum cascade lasers operating at terahertz frequencies by heterodyning the free-running quantum cascade laser with two far-infrared gas lasers. Beat notes are detected with a GaAs diode mixer and a microwave spectrum analyzer, permitting very precise frequency measurements and giving instantaneous linewidths of less than -30 kHz. Characteristics are also reported for frequency tuning as the injection current is varied.

Journal Article↗

The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood.

Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm(-1), yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm(-1) and 1093 cm(-1). This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM.

Blood Glucose↗

Dielectrophoretic manipulation of surface-bound DNA.

Dielectrophoretic manipulation enables the positioning and orientation of DNA molecules for nanometer-scale applications. However, the dependence of the dielectrophoretic force and torque on the electric field magnitude and frequency has to be well characterised to realise fully the potential of this technique. DNA in solution is attracted to the strongest electric field gradient (i.e. the electrode edge) as a result of the dielectrophoretic force, while the dielectrophoretic torque aligns the DNA with its longest axis parallel to the electric field. In this work, the authors attached -DNA fragments (48 and 25 kilobases) to an array of gold microelectrodes via a terminal thiol bond and characterised the orientation and elongation as a function of electric field magnitude (0.1-0.8 MVm) and frequency (0.08-1.1 MHz). Maximum elongation was observed between 200 and 500 kHz for the attached DNA. Dielectrophoresis is limited by thermal randomisation at electric fields below 0.1 MVm and by electrothermal effects above 0.7 MVm. The authors conclude that dielectrophoresis can be used to manipulate surface-immobilised DNA reproducibly.

Journal Article↗

Present treatment options for atrial fibrillation.

Atrial fibrillation is the commonest sustained cardiac arrhythmia. It accounts for >35% of all hospital admissions for cardiac arrhythmias in the United States. The presence of atrial fibrillation increases the mortality of a population by up to twofold. The risk of stroke increases from 1.5% in patients with atrial fibrillation from 50-59 years of age to up to 23.5% for such patients aged 80-89 years. Although the diagnosis of atrial fibrillation is usually straightforward, effective treatment is not. This article will discuss how rhythm control of atrial fibrillation can best be achieved, the controversy over the rhythm versus rate control, the maintenance of sinus rhythm with antiarrhythmic drugs after cardioversion, and prevention of thromboembolism. Finally, the recent advances in various non-pharmacological approaches for the treatment of atrial fibrillation will be highlighted.

Aged↗

The development of terahertz sources and their applications.

The terahertz region of the electromagnetic spectrum spans the frequency range between the mid-infrared and the millimetre/microwave. This region has not been exploited fully to date owing to the limited number of suitable (in particular, coherent) radiation sources and detectors. Recent demonstrations, using pulsed near-infrared femtosecond laser systems, of the viability of THz medical imaging and spectroscopy have sparked international interest; yet much research still needs to be undertaken to optimize both the power and bandwidth in such THz systems. In this paper, we review how femtosecond near-infrared laser pulses can be converted into broad band THz radiation using semiconductor crystals, and discuss in depth the optimization of one specific generation mechanism based on ultra-fast transport of electrons and holes at a semiconductor surface. We also outline a few of the opportunities for a technology that can address a diverse range of challenges spanning the physical and biological sciences, and note the continuing need for the development of solid state, continuous wave, THz sources which operate at room temperature.

Crystallography↗

Evolution of fractal patterns during a classical-quantum transition.

We investigate how fractals evolve into nonfractal behavior as the generation process is gradually suppressed. Fractals observed in the conductance of semiconductor billiards are of particular interest because the generation process is semiclassical and can be suppressed by transitions towards either fully classical or fully quantum-mechanical conduction. Investigating a range of billiards, we identify a "universal" behavior in the changeover from fractal to nonfractal conductance, which is described by a smooth evolution rather than deterioration in the fractal scaling properties.

Journal Article↗

Developments in digital radiography: an equipment update.

Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system.

Equipment Design↗

Threshold contrast detail detectability measurement of the fluoroscopic image quality of a dynamic solid-state digital x-ray image detector.

Solid-state digital x-ray imaging detectors of flat-panel construction will play an increasingly important role in future medical imaging facilities. Solid-state detectors that will support both dynamic (including fluoroscopic) and radiographic image recording are under active development. The image quality of an experimental solid-state digital x-ray image detector operating in a continuous fluoroscopy mode has been investigated. The threshold contrast detail detectability (TCDD) technique was used to compare the fluoroscopic imaging performance of an experimental dynamic solid-state digital x-ray image detector with that of a reference image intensifier television (IITV) fluoroscopy system. The reference system incorporated Plumbicon TV. Results were presented as a threshold detection index, or H(T)(A), curves. Measurements were made over a range of mean entrance air kerma (EAK) rates typically used in conventional IITV fluoroscopy. At the upper and mid EAK rate range (440 and 220 nGy/s) the solid-state detector outperformed the reference IITV fluoroscopy system as measured by TCDD performance. At the lowest measured EAK rate (104 nGy/s), the solid-state detector produces slightly inferior TCDD performance compared with the reference system. Although not statistically significant at this EAK rate, the difference will increase as EAK is lowered further. Overall the TCDD results and early clinical experiences support the proposition that a current design of dynamic solid-state detector produces image quality competitive with that of modern IITV fluoroscopy systems. These findings encourage the development of compact and versatile universal x-ray imaging systems based upon solid-state detector technology to support R & F and vascular/interventional applications.

Biophysical Phenomena↗

A close-up look at Io from Galileo's near-infrared mapping spectrometer.

Infrared spectral images of Jupiter's volcanic moon Io, acquired during the October and November 1999 and February 2000 flybys of the Galileo spacecraft, were used to study the thermal structure and sulfur dioxide distribution of active volcanoes. Loki Patera, the solar system's most powerful known volcano, exhibits large expanses of dark, cooling lava on its caldera floor. Prometheus, the site of long-lived plume activity, has two major areas of thermal emission, which support ideas of plume migration. Sulfur dioxide deposits were mapped at local scales and show a more complex relationship to surface colors than previously thought, indicating the presence of other sulfur compounds.

Extraterrestrial Environment↗

Initial technical and clinical evaluation of a new universal image receptor system.

The aim of this study was to evaluate the physical performance of an experimental flat-panel digital X-ray detector plate (FDXD), and to assess its clinical potential in radiographic and fluoroscopic mode. The efficiency of the detector was assessed by calculating the low-frequency detective quantum efficiency (DQE(0)), and a measure of image quality was obtained using a threshold contrast detail detectability (TCDD) test object. A range of clinical examinations were also carried out, and the results reviewed by members of the radiology staff. The DQE(0) of the system was calculated to be almost 75%, compared with a value of approximately 20 % for modern computed radiography equipment, offering the potential for increased image quality or significant dose reduction. Measurements using the TCDD test object demonstrated a corresponding advantage for the FDXD in image quality and dose efficiency. Clinical studies are producing radiographic results which are at least the equal of the best currently available digital technology, and a limited number of examinations using fluoroscopic mode at 25 frames per second have been equally encouraging. Equipment using FDXD technology could potentially fulfill all the radiographic and fluoroscopic requirements of the digital department, with improved image quality and dose efficiency.

Equipment Design↗

Functional overlap between the mec-8 gene and five sym genes in Caenorhabditis elegans.

Earlier work showed that the Caenorhabditis elegans gene mec-8 encodes a regulator of alternative RNA splicing and that mec-8 null mutants have defects in sensory neurons and body muscle attachment but are generally viable and fertile. We have used a genetic screen to identify five mutations in four genes, sym-1-sym-4, that are synthetically lethal with mec-8 loss-of-function mutations. The phenotypes of sym single mutants are essentially wild type. mec-8; sym-1 embryos arrest during embryonic elongation and exhibit defects in the attachment of body muscle to extracellular cuticle. sym-1 can encode a protein containing a signal sequence and 15 contiguous leucine-rich repeats. A fusion of sym-1 and the gene for green fluorescent protein rescued the synthetic lethality of mec-8; sym-1 mutants; the fusion protein was secreted from the apical hypodermal surface of the embryo. We propose that SYM-1 helps to attach body muscle to the extracellular cuticle and that another gene that is dependent upon mec-8 for pre-mRNA processing overlaps functionally with sym-1. RNA-mediated interference experiments indicated that a close relative of sym-1 functionally overlaps both sym-1 and mec-8 in affecting muscle attachment. sym-2, sym-3, and sym-4 appear to provide additional functions that are essential in the absence of mec-8(+).

Alleles↗

Estimation of injecting drug users in the City of Edinburgh, Scotland, and number infected with human immunodeficiency virus.

OBJECTIVES: To estimate (1) the number of current and former injecting drug users (IDU) infected with human immunodeficiency virus (HIV) alive in Edinburgh, and (2) the total number of current injectors in the city. METHODS: The number of infected IDU was estimated using a local register of HIV infections with correction for incompleteness of the register. The number of injectors was estimated by two independent methods, one based on the HIV register, the other by log-linear modelling of four lists of IDU interviewed in a city-wide survey, and/or attending drug treatment agencies and family doctors because of drug use. MAIN OUTCOME MEASURES: Estimates for the period 1992-1994 of number of IDU infected with HIV, total number of IDU, and prevalence of injecting. RESULTS: The HIV register indicated that 371 infected drug users who had ever injected were alive and resident in Edinburgh. In all, 95% of infected survey respondents appeared in the register, leading to a corrected estimate of 472 infected ever injectors. From this the number of IDU currently injecting (i.e. in the previous 6 months) was estimated to be 1770 (95% CI: 1340-2240), and the prevalence of injecting as 8.0 (95% CI: 4.8-10.8) per 1000 Edinburgh residents aged 15-59 years. Log-linear modelling gave an estimate of 2070 (95% CI: 1360-2800) current injectors. CONCLUSIONS: The number of HIV-infected IDU in Edinburgh was estimated to be twice that in the larger nearby city of Glasgow, where a higher proportion of young adults currently injected drugs. Knowledge of the high prevalence of HIV in Edinburgh IDU (19.3%), the prescribing of oral substitutes, and counselling by doctors and drug workers are perceived reasons for the reduction in the prevalence of injecting which has occurred in Edinburgh in recent years. Such measures need to be continued to encourage further reduction of injecting.

Adolescent↗