Search PubMedSearch

Biomedical subjects

A G Braun

Publications and source records attributed to A G Braun.

5 recordsLinked to original sources

A high-yield sampler for toxicological characterization of complex mixtures in combustion effluents.

Combustion sampling for toxicological assessment often requires that large (greater than 100 mg) lots of complex organic mixtures of wide volatility range be rapidly recovered from high temperature gases without contamination. A new sampler, meeting these criteria for studies of public health interest, has been developed and demonstrated. The device provides high sampling rates and intimate contacting of the samples stream with large volumes of a well-cooled, liquid solvent, dichloromethane (DCM). This promotes rapid organics dissolution from carrier gas and particulates and prompt dilution and quenching of the resulting solution, resulting in high organics collection efficiencies with minimal DCM losses. Solvent separation then remits large quantities of concentrated organics for chemical analysis and toxicological testing. One- to seven-hour interrogations of in-flame, post-flame, and flue gas regions gave 50- to 250-mg yields of complex organic mixtures. In side-by-side sampling of combustion exhaust, the DCM sampler provided higher yields of DCM solubles (identified with complex organic mixtures) and of S. typhimuirim mutagens (active without exogenous metabolizing agents) than did a filter/polymeric sorbent bed sampling train. The new sampler also collects polar and high volatile hydrocarbons such as benzaheyde, pentadiyne, m- and p-diethynyl-benzene, and 1-hexen-3,5-diyne. Nitration of naphthalene and pyrene in DCM solution (1 mg/mL each) was less than 1 part in 10(7) after a 345-min exposure to a bubbling flow of moist N2/air mixture (1:1 v/v) containing 107 ppm NO and 1.5 ppm NO2, indicating that for these condition a DCM sampler should resist artifactual nitration of aromatics. However, because of the very high bacterial mutagenicity of some nitroaromatics and the wide range of sampling conditions of environmental interest, nitration and all artifacts must still be scrutinized when using the DCM sampler. The DCM sampler is expected to contribute to public health impact assessments by facilitating detailed determinations of the identities, compositions, concentrations, sources, formation mechanisms, and biological activity of environmental toxicants in gaseous atmospheres.

Atmospheric Pressure

Teratogenic drugs inhibit tumour cell attachment to lectin-coated surfaces.

Interactions between embryonic cells are generally thought to have a central role in the control of development. When these morphogenic interactions are interrupted by either physical intervention or genetic defects, normal development is impaired. In accord with these experiments, specific interactions between embryonic cells have been demonstrated in several in vitro systems. Many investigators have described homotypic aggregation of chick embryo cells, and heterotypic specificity has been described. Because of the importance of morphogenic cell-cell interactions in development it follows that agents that interfere with these interactions, regardless of the interference mechanism, are potential teratogens. Here we have used a simple in vitro cell to surface recognition system in an attempt to screen for potential teratogens. We have found a very high correlation between inhibitory activity in the in vitro assay and reported teratogenic activity in human or animal studies. This suggests that many teratogenic agents may act by interfering, in an as yet unknown way, in normal cell to cell interactions.

Animals