Search PubMed⌕ Search

Biomedical subjects

A Francis

Publications and source records attributed to A Francis.

At least 55 records · Page 3Linked to original sources

Catatonia. II. Treatment with lorazepam and electroconvulsive therapy.

Case material and retrospective studies support the use of both lorazepam and ECT in treating catatonia, but few prospective investigations exist and none employ quantitative monitoring of response. In this study we test their efficacy in an open, prospective protocol, and define a "lorazepam test' with predictive value for treatment. Twenty-eight patients with catatonia were treated systematically with parenteral and/or oral lorazepam for up to 5 days, and with ECT if lorazepam failed. Outcome was monitored quantitatively during the treatment phase with the Bush-Francis Catatonia Rating Scale (BFCRS). In 16 of 21 patients (76%) who received a complete trial of lorazepam (11 with initial intravenous challenge), catatonic signs resolved. A positive response to an initial parenteral challenge predicted final lorazepam response, as did length of catatonic symptoms prior to treatment. Neither demographic variables nor severity of catatonia predicted response to lorazepam. Four patients failing lorazepam responded promptly to ECT. It is concluded that lorazepam and ECT are effective treatments for catatonia. The rating scale has predictive value and displays sensitivity to change in clinical status.

Adult↗

Reduced proconvulsant activity of caffeine in rats after a series of electroconvulsive seizures.

A variety of neurotransmitter receptor changes occur after a course of electroconvulsive seizures (ECS) in rats, including an increased density of adenosine A1 sites. Adenosine antagonism has been related to the proconvulsant action of methylxanthines such as caffeine. We determined tonic-clonic seizure duration in rats given ECS with caffeine (0-175 mg/kg, IP) after a course of one or six daily ECS. A single day of ECS did not affect the dose-dependent proconvulsant action of caffeine. After six daily ECS, the proconvulsant action of caffeine was reduced. After nine daily ECS, an A1 antagonist (8-cyclopentyl-1,3-dipropylxanthine) and an A2A antagonist (1-allyl-3,7-dimethyl-8-p-sulfophenylxanthine) showed reduced proconvulsant activity. The results suggest that the reduced proconvulsant action of caffeine after chronic ECS depends on adenosine antagonism.

4-(3-Butoxy-4-methoxybenzyl)-2-imidazolidinone↗

Caffeine augmentation of electroconvulsive seizures.

Caffeine has been used clinically to increase seizure length in electroconvulsive treatment (ECT). The present study was designed to establish an animal model of caffeine-augmented seizures for further study of mechanisms and effects of pharmacological manipulation of seizure length. Increasing doses of caffeine (0-200 mg/kg, IP) were given before electroconvulsive stimulation (ECS) in rats and resulting seizure lengths were quantified by timing of classical tonic-clonic convulsive movements. With this paradigm, caffeine led to a dose-dependent increase in seizure duration. This proconvulsant action of caffeine was detectable within 1 min after dosing, persisted for at least 230 min and was reversible. The results suggest that seizure length is a practicable measure in pharmacological modification of electroconvulsive seizures. They also suggest that pharmacologically-modified ECS can be modeled effectively in animals.

Animals↗

Interval between symptom onset and hospitalization in mania.

Previous studies of illness onset in mania lack a frequency distribution for the interval between symptom onset and hospitalization (hospital latency), although a bimodal distribution of illness onset been suggested. We identified 100 patients hospitalized for mania and found a unimodal distribution, with mean +/- SD of 3.3 +/- 3.2 weeks for hospital latency. Cases with short hospital latency (< 1 week, n = 15) were younger and had briefer psychiatric histories. The data were compared to other studies of hospital latency in mania.

Adolescent↗

Simultaneous presentation of sarcoidosis and acute myeloid leukaemia: predisposition to pulmonary haemorrhage.

A case of coexistent acute myeloid leukaemia and sarcoidosis is reported. This was complicated by recurrent pulmonary haemorrhage during reinduction and consolidation chemotherapy. A review of published papers on malignancy and sarcoidosis, in particular acute leukaemia is given. The outcome of most cases of acute leukaemia and sarcoidosis is poor with respiratory complications a frequent cause of death in this group. It is proposed that modifications to treatment to avoid pulmonary toxicity and maintenance of platelet counts above 40 x 10(9)/l are warranted to reduce the risk of this complication.

Adult↗

Continuation ECT: relapse prevention in affective disorders.

Relapse rates after the acute treatment of affective disorders with drugs or electroconvulsive therapy (ECT) are high (often 50-95%), despite preventive pharmacotherapy. In practice, some patients receive continuation and maintenance ECT after successful treatment of the index episode with ECT. We reviewed the charts of patients with affective illnesses who received continuation ECT (C-ECT) in our inpatient service from 1985 to 1991. In 33 courses of C-ECT, mean intertreatment interval was 10.1 days and the average duration of treatment was 10 weeks. One-year follow-up was available for 21 patients. Seven (33%) patients relapsed and needed re-admission within 1 year. The relapse rate for the patients with delusional depression was 42%, lower than the 95% reported for patients with delusional depression maintained on continuation pharmacotherapy before the C-ECT program started in our facility. No single factor examined was a significant predictor of relapse except C-ECT, which exhibited a sustained prophylactic effect for the year after the index episode.

Adult↗

A simple and rapid method of high quantity DNA isolation from cervical scrapes for detection of human papillomavirus infection.

Infection with human papillomavirus (HPV) is an important etiological factor in the development of cervical cancer, and detection of the viral genome is of prognostic importance, particularly for preneoplastic lesions. We developed a simple, easy and efficient non-organic method of DNA extraction from cervical scrapes for reliable detection of HPV DNA sequences. The method involves incubation of cell nuclei in higher concentration of proteinase K at 65 degrees C for 2.5 h. Following prolonged incubation at higher temperature, the enzyme is autoinactivated and the DNA isolated can be used directly for analysis without further purification. The recovery of DNA is more than 95% and it can be easily cleaved by restriction enzymes and is suitable for amplification by the polymerase chain reaction (PCR). The whole procedure is carried out in a single Eppendorf tube and a large number of specimens can be processed at a time without any error of handling. DNA extracted from a single smear sample is sufficient to conduct as many as four different molecular biology tests. This provides an opportunity for verification of sensitivity, specificity and reliability of each test for diagnosis of HPV infection without resorting to biopsy.

Adult↗

Detection of incident HIV infection by PCR compared to serology.

In order to determine the most sensitive method for the early detection of HIV infection, polymerase chain reaction (PCR) and serology were compared using matched peripheral blood mononuclear cells (PBMC) and serum samples taken sequentially at 3-month intervals on 17 HIV seroconverters. All samples from the time of enrollment in the study to the time of seroconversion were studied. [There were only two of the 17 cases where PCR and antigen positivity preceded EIA detectable seroconversion.] Initially, one of these cases was found to be PCR positive 11 months prior to seroconversion, however DNA fingerprinting techniques indicated that the early positive specimen did not belong to the subject in question. In a single subject, PCR was negative at the time of serologic evidence of infection but was positive at the next sampling 3 months later. In the remaining 14 cases, PCR was positive at the same sample time as full or partial seroconversion as determined by three EIA screening tests and Western blot. EIA antibody screen tests showed variability in detection of early HIV antibodies. We found no evidence for prolonged HIV infection prior to seroconversion. PCR offers little if any advantage over serology in the early detection of HIV infection in adults.

AIDS Serodiagnosis↗

Comparison of saliva and blood for human immunodeficiency virus prevalence testing.

Testing saliva for the detection of human immunodeficiency virus (HIV) antibodies has many potential advantages for epidemiologic surveillance. A commercial ELISA kit and a standardized in-house immunoblot (IB) system were slightly modified to enhance antibody detection in saliva. Frozen saliva specimens from Toronto Sexual Contact Study participants (including sequential saliva specimens collected during seroconversion) were tested as were fresh saliva samples collected from a population of street-based intravenous drug users (IVDUs). HIV antibody results on saliva were compared with HIV serostatus determined by ELISA and IB on serum or dried blood spots. The overall sensitivity was 98.3% (117/119) for the kit and 99.2% (118/119) for IB; the specificity was 100% (429/429). In the IVDU population, compliance in the voluntary submission of specimens increased from 69% agreeing to provide blood samples to 89% agreeing to provide blood, saliva, or both. Saliva specimens can be easily collected under difficult field conditions with minimal training and provide a valuable alternative to testing blood for HIV-seroprevalence studies.

Cohort Studies↗

Comparison of three HIV antigen detection kits in sequential sera from a cohort of homosexual men.

HIV antigen detection kits are available from a number of commercial sources. Abbott, Coulter, and Du Pont antigen kits were used to test 661 sera collected sequentially from 65 members of the Toronto Sexual Contact Study (TSCS). The sera had been collected at 3-month intervals over 4 years from nine persistently HIV-seronegative men, 14 seroconverters, and 42 seroprevalent participants. Antigen was not detected in any seronegative men. Two of 14 seroconverters were antigen positive in the specimen immediately preceding seroconversion (by all kits). Antigen was detected in 22 of 56 seropositive participants; of these, 16 of 22 demonstrated the emergence of antigen during observation. Discrepancies were noted in the time of detection of antigen (ranging from 3 months to more than 3 years) in nine participants. Although overall concordance among all kits for all specimens appears high (95.4%), when the bias introduced by testing multiple specimens from the same patient is removed, the lower bound of concordance among all three kits is estimated to be 80%. Similarly, after correction, the upper and lower bound of estimates of sensitivity are Abbott 96, 92%; Coulter 88, 63%; and Du Pont 88, 58%. There are significant differences in the performance characteristics of these commercial products for the detection of HIV antigen in serum.

AIDS-Related Complex↗