Search PubMed⌕ Search

Biomedical subjects

A Fazekas

Publications and source records attributed to A Fazekas.

192 records · Page 11Linked to original sources

VIP and noncholinergic vasodilatation in rabbit submandibular gland.

The effect of parasympathetic nerve activation on rabbit submandibular gland (SMG) blood flow and saliva secretion were studied before and after systemic administration of atropine or hexamethonium. The parasympathetic fibers were stimulated electrically (2 and 15 Hz, 10 V, 1 msec) at the plexus around the submandibular salivary duct or at the chorda lingual nerve. In untreated animals, stimulation of parasympathetic fibers caused a frequency-dependent increase of salivary secretion and blood flow in the SMG. Atropine treatment completely abolished saliva secretion at 2 Hz and 15 Hz and the increase in SMG blood flow during stimulation at 2 Hz. Although atropine significantly reduced the vasodilatory response at 15 Hz, the highest blood flow measured under such circumstances was still about 2.5 times the prestimulation value. After hexamethonium administration no blood flow increase or saliva secretion was seen upon chorda lingual stimulation. The concentration of vasoactive intestinal polypeptide (VIP)-like immunoreactivity in the venous effluent of the SMG increased during nerve stimulation. Atropine significantly reduced, and hexamethonium abolished this VIP-output elicited by parasympathetic nerve stimulation. Local infusion of VIP, peptide histidine isoleucine (PHI) and substance P all caused atropine-resistant vasodilation but no salivation. The present data suggest that VIP and possibly PHI play a role in the atropine-resistant vasodilatation in rabbit submandibular gland elicited by parasympathetic nerve stimulation. The contribution of sensory mediators such as substance P released by stimulation of afferent nerves in the chorda lingual nerve to the salivary and vasodilatory responses seems to be of minor importance in the rabbit submandibular gland.

Animals↗

The effect of acid etching on vascular diameter of pulp-vessels in rat incisor (vitalmicroscopic study).

Conditioning agents used on dentin with composite materials are biologically active and may have deleterious effects on the pulpal microcirculation. No data are available on the immediate vascular effect of etching materials applied on a constant thin pulpal dentin. In this study the authors examined whether the application of 36% phosphoric acid (Conditioner 36, 15 seconds) or itakonic acid with 10% maleic acid (NRC Non-Rinse Conditioner, 20 seconds), as recommended by the manufacturers, alters the blood circulation in the pulp of the rat's lower incisors. The effect of prolonged etching time (60 seconds) was also assessed (Conditioner 36). The application of saline served as the untreated control. The technique of vitalmicroscopy was used on the first lower incisor of 40 (10-10 in each group) male Sprague-Dawley rats (weighing 350 +/- 8 g SE) to record the changes in vessel diameter prior to and at 5, 15, 30 and 60 minutes after the test materials were administered on the dentin. In the control rats, the vessel diameter was stable during the entire experiment. Acid conditioning as recommended by the manufacturers tended to cause vasodilatation, though these alterations were statistically not significant when compared to the control group (ANOVA, p > 0.05). After prolonged etching time (Conditioner 36, 60 seconds) significant vasoconstriction (-14.4 +/- 6.13; -10.59 +/- 4.2; -11.96 +/- 6.75; -5.49 +/- 5.78%) was observed (ANOVA, p < 0.05). In this group, stasis developed in pulpal blood circulation in 40% of rats (Cochran's-Q test, p < 0.05), gas-bubble formation was observed in 30% and the disappearance of the pulpal wall occurred in 20%. These results suggest that exposition time with acid is crucial to the pulpal microcirculation. That is, acid conditioning applied as indicated (for 15-20 seconds) onto a very thin layer of dentin only slightly affects the blood supply to the dental pulp; however, prolonged etching time (for 60 seconds) results in immediate failure of microcirculation in the dental pulp of rats.

Acid Etching, Dental↗

Comparative analysis of pulpal circulatory reaction to an acetone-containing and an acetone-free bonding agent as measured by vitalmicroscopy.

Despite great progress in the production of new dental polymers, application of these products is still controversial. The unlined utilization of cytotoxic adhesive materials on pulpal dentin can adversely influence the pulp, leading to alterations in local microcirculation that can be an early sign of pathological changes. In a previous study by the authors, the effect of an acetone-free bondmaterial was examined on the vascular diameter of pulpal vessels by means of vitalmicroscopy. In this study, experiments comparing experimental data provided by an acetone-containing bondmaterial to these earlier findings with acetone-free ones have been performed. Thirty male Sprague-Dawley rats (weighing 333+/-9 g) were used for this investigation. The first lower incisor was prepared for vitalmicroscopy. Changes in vessel diameter were recorded prior to and 5, 15, 30 and 60 minutes after the investigated materials (Scotchbond Multi-Purpose Dental Adhesive System or Prime & Bond 2.1) were administered on dentin as recommended by the manufacturer. In control rats (saline administration), the vessel diameter was stable during the experiment. In the presence of acetone-free bondmaterial (Scotchbond), the vessel diameter was increased during the experimental period in relation to the baseline (12.15+/-2.85%; 16.36+/-2.39%; 14.16+/-3.48%; 12.12+/-3.72%). In the presence of acetone-containing bondmaterial (Prime & Bond 2.1), a similar result was observed (10.56+/-2.27%; 16.13+/-2.94%; 17.88+/-2.54%; 14.54+/-3.16%). The differences between the control values and those registered with test groups were significant (p<0.05; ANOVA). There was no significant difference among the test groups. The results of this study suggest that dental bond materials applied on a very thin layer of dentin may affect the blood supply to the dental pulp. However, no stasis or prestasis has been detected, indicating a possible reversible effect. The authors could not show any statistical difference between the vasodilatation caused by the acetone-containing and the acetone-free bond material.

Acetone↗

Microscopic patterns in surgically removed spleens.

348 spleens surgically removed have been examined microscopically and classified into 3 groups: (I) 154 emergency splenectomies (86 traumatic ruptures, 44 enlarged supramesocolic exeresis, 44 cirrhosis), (II) 143 therapeutic splenectomies (135 cases of hypersplenism among which 10 apparently primitive, 7 myeloproliferative syndromes, 1 hairy cell leukemia), and (III) 51 diagnostic splenectomies (7 non specific inflammations, 2 tuberculosis, 1 mycosis, 6 echinococcosis, 12 leukemias, 9 non-Hodgkin's lymphomas, 13 Hodgkin's lymphomas, 1 primary splenic hemangioma). The study of the first group material, obtained especially of traumatic rupture, has been very valuable to follow the spleen microscopic structure in normal humans of different age. The latter two group cases have raised interesting problems of microscopic diagnosis, permitting at the same time a better understanding of the pathology of this organ.

Adolescent↗

Myasthenia gravis: demonstration of membrane attack complex in muscle end-plates.

The membrane attack complex (MAC) assembles from C5b-9 complement components and has neoantigenic properties. Antihuman-MAC rabbit immunserum was applied in order to localize the MAC in myasthenic muscles. Using the indirect immunoperoxidase method MAC was demonstrated at the motor end-plates in eleven myasthenic patients who underwent thymectomy. This result provides direct evidence of antibody-dependent complement-mediated injury of acetylcholine receptors in myasthenia gravis.

Adolescent↗

[Root canal preparation for obturation using nickel-titanium mechanical devices].

Engine-driven ProFile instruments manufactured by Maillefer (Switzerland) and Tulsa Dental Products (USA) have been used for cleaning and shaping root canals. Both of them are nickel titanium, U-shaped instruments designed for a controlled slow speed (250 rpm) rotary handpiece. In contrast to the Maillefer instruments ProFile Series 29 files (Tulsa Dental) show a constant 29% increase between tip diameters. As these more tapered instruments (ProFile 0.04; 0.06) are rotated, they produce a "crown-down" preparation, resulting in a tunnelform taper from orifice to apex. According to our experiences ProFile instruments are useful alternative tools for root canal preparation quickly and efficiently.

Dental Instruments↗