Search PubMed⌕ Search

Biomedical subjects

A F Kopp

Publications and source records attributed to A F Kopp.

At least 19 recordsLinked to original sources

[Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating].

PURPOSE: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. MATERIALS AND METHODS: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30 %, 30 - 50 %, > 50 %). RESULTS: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30 % in four patients, lesions of 30 -, 50 % in five patients and a stenosis > 50 % in one patient. Eighteen patients showed no lesions. CONCLUSION: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method.

Adult↗

A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage.

A method for cardio-thoracic multislice spiral CT imaging with ECG gating for suppression of heart pulsation artifacts is introduced. The proposed technique offers extended volume coverage compared with standard ECG-gated spiral scan and reconstruction approaches for cardiac applications: Thin-slice data of the entire thorax can be acquired within one breath-hold period using a four-slice CT system. The extended volume coverage is enabled by a modified approach for ECG-gated image reconstruction. For a CT system with 0.5-s gantry rotation time, images are reconstructed with 250-ms image temporal resolution. Instead of selecting scan data acquired in exactly the same phase of the cardiac cycle for each image as in standard ECG-gated reconstruction techniques, the patient's ECG signal is used to omit scan data acquired during the systolic phase of highest cardiac motion. With this approach cardiac pulsation artifacts in CT studies of the aorta, of paracardiac lung segments, and of coronary bypass grafts can be effectively reduced.

Aortic Diseases↗

Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT.

High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.

Adult↗

Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

AIMS: A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS: A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (>or=50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (>or=50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2). CONCLUSIONS: High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries.

Coronary Angiography↗

[Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences].

PURPOSE: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. MATERIALS AND METHODS: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a ss-Blocker, the heart rate was between 55 and 67 bpm. RESULTS: The scan time for calcium score was 12 s, for CTA 18 s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. CONCLUSION: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated.

Aged↗

[Characterization of motion artifacts in multi-slice spiral CT].

PURPOSE: Motion artifacts in multi-slice spiral CT (MSCT) resulting from object motion in and against the table feed direction (z-direction) are examined using a spherical phantom. For image interpretation of complex anatomic structures, qualitative reference points are, also applicable to selected, which are ECG-gated cardiac imaging. In this case the motion of the coronary vessels in phase with the cardiac contraction must be considered. METHODS: Measurements are obtained with a multi-slice spiral CT with a rotation time of 500 ms for 4 x 1.0 mm and 2 x 0.5 mm collimation. The phantom consists of an acrylic glass body with imbedded glass beads of 1, 2, and 3 mm diameter. The object motion is sinusoidal with an amplitude of 5 mm and frequencies of 60/min and 90/min. Compensation of the table feed by object motion is examined as a special case. RESULTS: Small parameter changes can induce a strikingly different image quality, and the moving objects emerge in different slices. Depending on the phase of the movement with respect to the CT scan, objects up to a size of 3 mm can vanish completely or appear hyperintense in the image. The model investigated is also applicable to ECG-gated cardiac imaging for the detection of stenosis. It can explain variations in the reproducibility and absolute score values of the calcium scoring. CONCLUSION: The presented considerations and results must be taken into account in image interpretation with possible object motion in the z-direction. Variations in the determination of the degree of stenosis or in calcium score measurements can be explained by different vessel motion during the diastolic heart phase.

Artifacts↗

Virtual coronary angioscopy using multislice computed tomography.

BACKGROUND: With faster image acquisition times and thinner slice widths, multislice detector computed tomography (MSCT) allows visualisation of human coronary arteries with diagnostic image quality. In addition to conventional axial slices, virtual coronary angioscopies (VCA) can be reconstructed using MSCT datasets. OBJECTIVE: To evaluate the feasibility of reconstructing VCA and to determine the clinical value of this new application in detecting atherosclerotic coronary artery lesions. METHODS: Datasets obtained by contrast enhanced non-invasive coronary angiography using MSCT (Somatom VZ) were analysed from 14 consecutive patients. VCA were simulated in 14 coronary arteries (left anterior descending, n = 7; right coronary, n = 7). Lesion detection was undertaken on conventional contrast enhanced axial slices, as well as by VCA. Intracoronary ultrasound (ICUS) was used as the gold standard for in vivo plaque detection. RESULTS: 38 lesions were detected both on ICUS and on axial slices: 14 severe target lesions of > 75% area stenosis (11 calcified, three non-calcified), and 24 intermediate lesions of < or = 75% area stenosis (seven calcified, 17 non-calcified). Using VCA, all severe lesions (n = 14) and all calcified intermediate plaques (n = 7) could clearly be identified. However, non-calcified intermediate lesions (n = 17) could not be accurately distinguished from the vessel wall; they were recognised as vessel wall alterations without significant luminal narrowing. CONCLUSIONS: Current MSCT technology allows reconstruction of VCA with good image quality. Despite a more anatomical view of heart and coronary vessels on three dimensional reconstruction, conventional axial slices were found to be superior for detecting coronary lesions. Thus further technical innovations are required before VCA can become a useful technique in clinical cardiology.

Adult↗

Noninvasive detection of coronary lesions by multislice computed tomography: results of the New Age pilot trial.

The reliable noninvasive assessment of coronary artery disease would constitute an important step forward in clinical cardiology. The aim of the New Age pilot trial was to evaluate the diagnostic accuracy of multislice computed tomography (MSCT) in determining coronary lesions. As a gold standard for in vivo plaque detection, intracoronary ultrasound (ICUS) was used. Forty plaques were detected by ICUS in 15 target vessels (LAD, n = 8; RCA, n = 7) in patients assigned for ICUS-guided PTCA. Preinterventional MSCT was performed in all patients and the results were compared to ICUS with regard to lesion detection and quantification. According to ICUS results, the 40 plaques were divided into three groups: group I, mild lesions < 50% (n = 14; 44.36% +/- 5.77%); group II, intermediate lesions 50%-75% (n = 12; 59.18% +/- 9.39%); and group III, severe lesions > 75% (n = 14; 91.47% +/- 3.68%). All MSCT scans showed sufficient image quality for analysis. Thirty of 40 (75%) plaques were detected by MSCT in a first blinded session. After unblinding the ICUS results, the remaining 10 (25%) plaques could be identified. Lesion severity was classified correctly in 34 of 40 (85%) plaques. Plaque calcifications were diagnosed correctly in 16 of 19 (84.2%) plaques. Quantification of vessel size revealed a good correlation to the ICUS results (r(2) 0.68; P = 0.004). Noninvasive MSCT angiography showed good diagnostic accuracy with regard to lesion detection and quantification of vessel size. The overall good image quality, makes this new technology a promising modality, which might become an alternative diagnostic approach in patients with known or suspected coronary artery disease. Cathet Cardiovasc Intervent 2001;53:352-358.

Adult↗

Biphasic spiral CT of the liver: automatic bolus tracking or time delay?

The aim of this study was to evaluate the value of automatic bolus tracking for biphasic spiral CT of the liver in comparison with time delay examinations. Forty patients scheduled for a biphasic spiral CT of the liver randomly were examined either with time delay of 25 s for the arterial phase and 55 s for the portal-venous phase (n = 20), or with an automatic scan start triggered by contrast enhancement in the aorta (n = 20). Examinations were performed with 120 ml of contrast material and a flow rate of 4.0 ml/s. Density measurements of the aorta, of the liver parenchyma, and of the spleen were obtained by means of regions of interest (ROI). The end of the arterial phase was considered when hepatic parenchymal enhancement was greater than 20 HU. In all patients of the group with automatic bolus tracking arterial scanning was completed in the arterial phase of the liver. In 25 % of patients with fixed time delay, however, an enhancement of liver parenchyma during arterial phase greater than 20 HU was observed. During the portal-venous phase there was no significant difference in parenchymal enhancement between both groups. Automatic bolus tracking allows an individualized timing of the arterial phase in biphasic spiral CT of the liver. The timing is more accurate than in time delay scanning.

Adult↗

Automatic bolus tracking in monophasic spiral CT of the liver: liver-to-lesion conspicuity.

The aim of this study was to evaluate the value of automatic bolus tracking for monophasic spiral CT of the liver and to assess the liver-to-lesion conspicuity in comparison with time-delay examinations. In 40 patients scheduled for therapy control of known hypovascular hepatic metastases a monophasic spiral CT was completed either with time delay of 65 s (n = 20) or with automatic bolus tracking in the liver parenchyma (n = 20). Examinations were performed with 120 ml of contrast material and a flow rate of 3.0 ml/s. For automatic bolus tracking a parenchymal enhancement threshold of 40 HU was used. Contrast enhancement in the liver parenchyma and in liver lesions was obtained by means of regions of interest (ROI). Mean parenchymal enhancement was not significantly different between time delay and bolus-tracking group. In 4 of 20 patients in the bolus-tracking group the threshold level of 40 HU was not reached. With automatic bolus tracking a significantly higher liver-to-lesion density difference was observed (P < 0.0001). Automatic bolus tracking allows a better liver-to-lesion conspicuity in monophasic spiral CT. Contrary to recent studies, a significantly higher parenchymal enhancement was not found using automatic bolus tracking.

Adult↗

Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound.

The reliable non-invasive detection of coronary artery disease (CAD) is a prime goal for future developments in clinical cardiology. In addition to the documentation of high-grade stenoses, the detection of vulnerable plaques is of major importance for risk stratification and early treatment to prevent plaque rupture. Recently, a new generation of fast spiral CT has been introduced using a multi-slice technique (MSCT), which is the first real quantum leap in CT since the introduction of spiral CT in the early 1990s. We report on non-invasive differentiation of coronary plaque morphology by MSCT in patients with lesions in the proximal left anterior descending artery (LAD). The results were compared with the findings of intracoronary ultrasound (ICUS). The ICUS and MSCT scans were analysed in 6 patients scheduled for ICUS-guided PTCA. One target lesion was selected in each patient. On ICUS, two lesions were classified as soft, two as intermediate and two as calcified according to established criteria based on echogenicity. By multislice CT, density measurements (expressed in Hounsfield Units, HU) were performed at 16 randomly selected areas within the plaques. The two soft plaques showed a mean density of 6+/-28 and -5+/-25 HU, the two intermediate plaques of 83+/-17 and 51+/-19 HU, and the two calcified plaques of 489+/-372 and 423+/-111 HU. To our knowledge, this is the first report on non-invasive characterisation of coronary lesions by MSCT. Plaque composition could be clearly differentiated and classified according to the ICUS results by determining tissue density within the lesions. Thus, this new technology holds promise for non-invasive risk assessment in patients with known or suspected CAD since also rupture-prone soft coronary lesions can be detected by use of this new technique.

Aged↗

Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.

OBJECTIVES: The aim of the present study was to evaluate the accuracy in determining coronary lesion configuration by multislice computed tomography (MSCT). The results were compared with the findings of intracoronary ultrasound (ICUS). BACKGROUND: The risk of acute coronary syndromes caused by plaque disruption and thrombosis depends on plaque composition rather than stenosis severity. Thus, the reliable noninvasive assessment of plaque configuration would constitute an important step forward for risk stratification in patients with known or suspected coronary artery disease. Just recently, MSCT scanners became available for general purpose scanning. Due to improved spatial and temporal resolution, this new technology holds promise to allow for differentiation of coronary lesion configuration. METHODS: The ICUS and MSCT scans (Somatom Volume Zoom, Siemens, Forchheim, Germany) were performed in 15 patients. Plaque composition was analyzed according to ICUS (plaque echogenity: soft, intermediate, calcified) and MSCT criteria (plaque density expressed by Hounsfield units [HU]). RESULTS: Thirty-four plaques were analyzed. With ICUS, the plaques were classified as soft (n = 12), intermediate (n = 5) and calcified (n = 17). Using MSCT, soft plaques had a density of 14 +/- 26 HU (range -42 to +47 HU), intermediate plaques of 91 +/- 21 HU (61 to 112 HU) and calcified plaques of 419 +/- 194 HU (126 to 736 HU). Nonparametric Kruskal-Wallis test revealed a significant difference of plaque density among the three groups (p < 0.0001). CONCLUSIONS: Our results indicate that coronary lesion configuration might be correctly differentiated by MSCT. Since also rupture-prone soft plaques can be detected by MSCT, this noninvasive method might become an important diagnostic tool for risk stratification in the near future.

Adult↗

Accuracy and reliability of quantitative measurements in coronary arteries by multi-slice computed tomography: experimental and initial clinical results.

AIM: To evaluate the accuracy of non-invasive measurements within coronary arteries by multi-slice computed tomography (MSCT). We present experimental as well as clinical data. MATERIALS AND METHODS: Silicon tubes simulating coronary arteries (outer diameter 6 mm, lumen diameter within stenotic area 2 mm) were used for experimental studies. Clinical data were derived from 15 patients in whom vessel diameters were assessed by MSCT, intracoronary ultrasound (ICUS) and quantitative coronary angiography (QCA). MSCT were performed in a Somatom Volume Zoom(trade mark)CT system (Siemens, Forchheim, Germany) at 2 collimated slice widths (2.5 mm, 1.0 mm). RESULTS: Outer silicon tube diameters were overestimated by MSCT (6.56 mm +/- 0.32 mm). All measurements revealed significantly better results on 1.0 collimation compared to 2.5 mm collimation (outer diameter: 6.36 mm +/- 0.22 mm vs 6.76 mm +/- 0.27 mm, P < 0.0001; lumen diameters: 1.83 mm +/- 0.14 mm vs 1.51 mm +/- 0.19 mm, P < 0.0001). The comparison of vessel diameters within human coronary arteries revealed comparable results between ICUS and MSCT (4.89 mm +/- 0.67 mm vs 4.91 mm +/- 0.71 mm, P = 0.79, r = 0.79, P < 0.0001). QCA-measurements showed significantly lower results (3.67 +/- 0.71, P < 0.0001, r = 0.62, P < 0.001). CONCLUSIONS: Experimental as well as initial clinical results indicate acceptable reliability and accuracy of quantitative measurements by MSCT, when using thin collimated slice widths. Partial volume effects lead to a systematic overestimation of vessel size. MSCT has the potential to become an important non-invasive diagnostic tool in patients with coronary artery disease.

Coronary Angiography↗

[Multidetector CT Angiography - is it a valuable screening tool to detect significant renal artery stenosis?].

PURPOSE: To evaluate the diagnostic value of multidetector CT angiography (MDCTA) of the renal arteries. METHODS: 27 patients underwent MDCTA of the renal arteries. Scan parameters were: collimation 4 x 1 mm, pitch 1.5, effective slice thickness 1.25 mm, reconstruction increment 0.8 mm, circulation time measurement, power injection of 80 ml iomeprol 400, flow 4 ml/sec. Independent reading on laser film was done by two radiologists using edited maximum intensity projections, multiplanar reconstructions and source images. Standard of reference was a 3D-FLASH MR angiography (1.5 T, 3.9/1.2, 10 degrees 0.2 mmol GdDTPA/kg bw) in 10 and intraarterial angiography in 17 patients. RESULTS: Analysing 63 arteries, sensitivity, specificity, positive predictive value and negative predictive value in terms of detection of moderate and high grade renal artery stenosis (n = 10) were 90, 98, 90 and 98 % for reader A, and 90 % each for reader B, respectively (kappa = 0.91 interobserver agreement). 1/11 accessory renal arteries was missed by both angiography and MDCTA. Image quality was graded as excellent or good in 26/27 of cases by both readers. CONCLUSION: MDCTA proved to be a highly accurate tool in the detection of therapeutically relevant renal artery stenosis.

Aged↗

Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.

PURPOSE: To investigate how the technique of retrospective gating can be used to optimize reconstruction of multi-detector row computed tomographic (CT) images for each of the three major coronary arteries during the cardiac cycle. MATERIALS AND METHODS: Multi-detector row coronary CT angiograms obtained in 50 patients were reconstructed at 20%-80% of the cardiac cycle in increments of 10%. Two blinded independent reviewers assessed the image quality, in terms of artifacts and visibility, obtained with three-dimensional postprocessing for segments 1-3 (right coronary artery), segments 5-8 (left main and left anterior descending coronary arteries), and segments 11 and 12 (left circumflex artery). The following grades were assigned: 1, very poor; 2, poor; 3, fair; 4, good; and 5, excellent. RESULTS: The left anterior descending artery was best visualized in middiastole at 60%-70% of the cardiac cycle, and the left circumflex artery was best visualized at 50%. The optimal reconstruction window for the right coronary artery was significantly different at 40% (P < .05). Although there was good agreement (kappa = 0.75) between the two reviewers, there was a high degree of variation in the patient population. CONCLUSION: The image reconstruction window for CT angiography of the coronary arteries should be adapted to each coronary artery. The use of one fixed time point in the cardiac cycle for image reconstruction does not provide optimal image quality.

Aged↗

[Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT].

PURPOSE: In this paper a method for cardiac imaging with fast multi-slice CT and retrospectively ECG-gated spiral acquisition is presented. METHODS: A fast multi-slice CT system with 4 simultaneously acquired slices and 0.5 s rotation time is used (Siemens Somatom VolumeZoom). Continuous spiral data of the entire heart volume is acquired together with the patient's ECG and reconstructed with dedicated spiral algorithms providing 250 ms temporal resolution. Three-dimensional image data sets are built up from overlapping slices that are reconstructed in an arbitrary, user-defined phase of the heart cycle (e.g. diastolic phase). To evaluate the capability of the method for functional imaging complete three-dimensional image volumes are reconstructed from the same spiral data set in different phases of the heart cycle. RESULTS: A spiral data set of the entire heart volume may be acquired within a single breath-hold. Typical scan times for standard examinations with 3 mm slice width are 10-15 s, and for high-resolution CT angiographies of the coronary arteries with 1.25 mm slice width about 30-35 s. Motion-free reconstruction of the heart and coronary arteries with high spatial resolution is possible in the diastolic phase of the heart cycle. Multi-phase reconstructions from the same spiral scan data set are possible, however, motion artifacts in heart phases with fast cardiac motion may not be completely avoided. CONCLUSION: Fast multi-slice spiral CT with retrospectively ECG-gated spiral reconstruction is well suited for three-dimensional and functional imaging of the heart, especially for high-resolution imaging of calcified coronary plaques and CT-angiography of the coronary arteries.

Algorithms↗

[Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution].

PURPOSE: The significantly improved temporal and spatial resolution of Multidetector-Row CT opens up new possibilities for cardiac imaging. A method with retrospectively ECG-gated spiral acquisition is presented. MATERIALS AND METHODS: A total of 10 patients underwent cardiac CT on a fast multi-slice CT system with 4 simultaneously acquired slices and 0.5 s rotation time (Siemens Somatom Volume Zoom). Continuous spiral data of the entire heart volume (5 studies precontrast for calcium scoring, 5 studies with contrast) were acquired together with the patient's ECG and reconstructed with dedicated spiral algorithms providing 250 ms temporal resolution. Three-dimensional image data sets were built up from overlapping slices that were reconstructed in an arbitrary, user-defined phase of the heart cycle (e.g., diastolic phase). To evaluate the capability of the method for functional imaging, complete image volumes were reconstructed from the same spiral data set in different phases of the heart cycle. RESULTS: Within a single breath-hold, a spiral data set of the entire heart volume could be acquired. Typical scan times for standard examinations with 3-mm slice width were 12-17 s, and for high-resolution CT angiographies of the coronary arteries with 1.25-mm slice width about 25-35 s. Motion-free reconstruction of the heart and coronary arteries with high spatial resolution were possible in the diastolic phase of the heart cycle. Multiphase reconstructions from the same spiral scan data set were possible. CONCLUSIONS: Fast multi-slice spiral CT with retrospectively ECG-gated spiral reconstruction is well suited for three-dimensional and functional imaging of the heart, especially for high-resolution imaging of calcified coronary plaques and CT-angiography of the coronary arteries.

Coronary Angiography↗