Search PubMed⌕ Search

Biomedical subjects

A F Gmitro

Publications and source records attributed to A F Gmitro.

21 records · Page 2Linked to original sources

Development and evaluation of spectral classification algorithms for fluorescence guided laser angioplasty.

Laser angioplasty, or the ablation of atherosclerotic plaque using laser energy, has tremendous potential to expand the scope of nonsurgical treatment of obstructive vascular disease. Clinical laser angioplasty, however, has been hindered by an unacceptable risk of vessel perforation. Laser-induced fluorescence spectroscopy can discriminate atherosclerotic from normal artery and may therefore be capable of guiding selective plaque ablation. To assess the feasibility of utilizing spectral information to discriminate arterial tissue type, several classification algorithms were developed and evaluated. Arterial fluorescence spectra from 350 to 700 nm were obtained from 100 human aortic specimens. Seven spectral classification algorithms were developed with the following techniques: multivariate linear regression, stepwise multivariate linear regression, principal components analysis, decision plane analysis, Bayes decision theory, principal peak ratio, and spectral width. The classification ability of each algorithm was evaluated by its application to the training set and to a validation set containing 82 additional spectra. All seven spectral classification algorithms prospectively classified atherosclerotic and normal aorta with an accuracy greater than 80 percent (range: 82-96 percent). Laser angioplasty systems incorporating spectral classification algorithms may therefore be capable of detection and selective ablation of atherosclerotic plaque.

Algorithms↗

A low-cost computed tomographic scanner.

The authors describe a film-recorded computed tomographic (CT) scanner that uses optical processing methods for reconstruction of a sectional image. Results are comparable to commercial CT methods using the same patient dose. Consequently, clinically satisfactory CT imaging can be performed at a substantially reduced cost.

Animals↗

Analysis and comparison of motion-correction techniques in diffusion-weighted imaging.

Motion continues to be a significant problem in MRI, producing image artifacts that can severely degrade image quality. In diffusion-weighted imaging (DWI), the problem is amplified by the presence of large gradient fields used to produce the diffusion weighting. Three correction methods applicable for correction of specific classes of motion are described and compared. The first is based on a generalised projection onto convex sets (GPOCS) postprocessing algorithm. The second technique uses the collection of navigator echoes to track phase errors. The third technique is based on a radial-scan data acquisition combined with a modified projection-reconstruction algorithm. Although each technique corrects well for translations, the radial-scan method proves to be more robust when more complex motions are present. A detailed description of the causes of MR data errors caused by rigid body motion is included as an appendix.

Algorithms↗