Muscular counterpulsation: preliminary results of a non-invasive alternative to intra-aortic balloon pump.

OBJECTIVES: IABP is the most widely used form of temporary cardiac assist and its benefits are well established. We designed an animal study to evaluate a device based on muscular counterpulsation (MCP) that should reproduce the same hemodynamic effects as IABP in a completely non-invasive way. METHODS: Six calves, 60+/-4 kg, divided into 2 groups, in general anaesthesia, equipped with EKG, Swan-Ganz, pressure probe in the femoral artery and flow probe in the left carotid artery, received either IABP through right femoral artery, or muscle counterpulsation (MCP). MCP consists of electrically induced skeletal muscle contraction during early diastole, triggered by EKG and microprocessor controlled by a portable device. For each animal the following parameters were also considered: mean aortic pressure (mAoP), CO, CI, left ventricular stroke work index (LVSWI), systemic vascular resistance (SVR) and mean femoral artery flow (Faf). We did 3 sets of measurements: baseline (BL), after 20 (M20) and 40 (M40) min of cardiac assistance. These measurements have been repeated after 40 min of rest for 3 times. Results are expressed as mean+/-SD. RESULTS: Baseline values: mAoP, 76.51+/-12 mmHg; mCVP, 11.5+/-3 mmHg; CO, 5+/-1 l/min per m(2); LVSWI, 0.77+/-0.2 KJ/m(2); SVR, 1040+/-15 dyns/cm(-5); Faf, 75.5+/-10 ml/min. IABP group: mAoP, 81.1+/-6 mmHg; mCVP, 1+/-0.1 mmHg; CO, 4.5+/-0.7 l/min per m(2); LVSWI, 0.69+/-0.2 KJ/m(2); SVR, 1424+/-8 dyns/cm(-5); Faf, 64.3+/-3 ml/min. MCP group: mAoP, 60.1+/-7 mmHg; mCVP, 23.6+/-2 mmHg; CO, 4.8+/-0.4 l/min per m(2); LVSWI, 0.69+/-0.2 KJ/m(2); SVR, 608+/-25 dyns/cm(-5); Faf, 92.3+/-12 ml/min. CONCLUSIONS: MCP and IABP had the same effects on CO and LVSWI. Moreover, MCP reduced SVR and increased the peripheral circulation without requiring any vascular access nor anticoagulation therapy.

Animals↗

Sutureless videoendoscopic thoracic aorta to iliac artery bypass: the easiest approach to occlusive aorto-iliac diseases.

OBJECTIVE: We designed an animal study to determine the feasibility of videoendoscopic thoracic aorta to iliac artery bypass using a sutureless anastomotic device for proximal anastomosis construction. METHODS: In 12 pigs the descending thoracic aorta was exposed using the thoracoscopic technique. A 4 mm PTFE thin wall graft was used as conduit. The proximal anastomosis was constructed using a mechanical device for sutureless anastomosis inserted through the camera port incision. The prosthesis was passed through the diaphragm in the retroperitoneal space and the distal anastomosis was done with running suture. RESULTS: The operation was successfully completed in 11 animals. One animal died due to hemorrage during anastomosis construction. Mean graft flow was 144 ml/min (range 88-167 mmHg). The angiogram showed no graft kinking or stenosis. Total operative time was 58 min (range 47-68 min). CONCLUSIONS: This approach allows quick and excellent exposure of the entire descending thoracic aorta. The use of the sutureless device to perform the proximal anastomosis dramatically reduces the technical demands of this procedure and could avoid an aortic clamp.

Anastomosis, Surgical↗

Cross-sectional compliance overestimates arterial compliance because it neglects the axial strain.

A high resolution echo-tracking system permits the calculation of cross-sectional compliance considering vessel diameter variations alone, and assumes that longitudinal movement of the vessel wall due to pulse pressure is negligible. However, using piezoelectric crystals sutured on the adventitia of the vessel wall we demonstrated that arterial length changes up to 5% (mean 2.7%) as a function of pulse pressure. Therefore, cross-sectional compliance seems to provide a limited approximation of the real phenomenon because it neglects axial vessel movement. Axial vessel movement is taken into account when the vessel compliance is calculated according to the principle of continuity of the mass: [equation: see text]. To verify this hypothesis we measured the blood flow gradient through 10 cm long segments of 10 pig carotid arteries (Qin - Qout) and divided it for the derivative of blood pressure over a given time (deltaP/deltat). For the same vessels, we calculated the cross-sectional compliance (CC) using the echo-tracking system (NIUS 02). We found a CC of (5.91 +/- 0.4) x 10(-7) micro m(2)/mm Hg and a segmental carotid compliance or dynamic compliance (C(d)) of (6.21 +/- 0.2) x 10(-8) micro m(3)/mm Hg. The impact of axial strain in calculations of compliance results in a dynamic compliance, which is one order of magnitude smaller than traditionally calculated arterial compliance.

Animals↗

Treatment of congenital aortic valve stenosis: impact of the Ross operation.

GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.

Adolescent↗

Surgery for aortic coarctation: a 30 years experience.

OBJECTIVE: A retrospective study to review the experience of a single center with surgery for aortic coarctation over a period of 30 years (1970-1999). METHODS: Criteria for inclusion: (a) aortic coarctation, isolated or associated with congenital heart defect; (b) surgery between 1970 and 1999. Data recorded: (1) date of surgery; (2) age at surgery; (3) associated lesions; (4) surgical technique; (5) simultaneous surgical procedures; (6) early and late surgical results in term of: (a) deaths; (b) need for reoperation because of re-coarctation or other cardiac lesion; (c) residual/recurrent pressure gradient, evaluated at cuff/Doppler at rest; (d) systemic hypertension, requiring medical treatment. RESULTS: One hundred and forty-one patients underwent surgery for aortic coarctation: 30 neonates, 29 infants, 45 children and 37 adults. Associated lesions were found in 8/37 (=21.6%) adults and in 73/104 (=70.1%) pediatric patients. There were no hospital deaths. During the follow-up there were one late death in the adults group (1/37=2.7%) and three late deaths in the pediatric group (3/104=2.9%), all unrelated with aortic coarctation. Re-operation because of re-coarctation occurred only in ten late survivors of the pediatric group (10/101=9.9%), 9/10 operated on before 1980 (P<0.00001). End-to-end anastomosis, enlarged to the aortic arch in neonates, was associated with the lowest incidence of re-coarctation (P<0.005). A significant (>20 mmHg at rest) pressure gradient was found in none of the adults, and in seven of the 91 pediatric patients (7/91=7.7%) late survivors. Three adults (3/36=8.3%) late survivors are on medical treatment to control systemic hypertension. CONCLUSIONS: The long-term results of our retrospective study confirm that surgery has to be considered the gold standard for the treatment of aortic coarctation. The interventional angioplasty techniques have to provide long-term outcome at least similar to the results obtained with surgery.

Age Factors↗

Tolerance of isolated rat hearts to low-flow ischemia and hypoxia of increasing duration: protective role of down-regulation and ATP during ischemia.

We tested the hypothesis that down-regulated hearts, as observed during low-flow ischemia, adapt better to low O2 supply than non-down-regulated, or hypoxic, hearts. To address the link between down-regulation and endogenous ischemic protection, we compared myocardial tolerance to ischemia and hypoxia of increasing duration. To that end, we exposed buffer-perfused rat hearts to either low-flow ischemia or hypoxia (same O2 shortage) for 20, 40 or 60 min (n = 8/group), followed by reperfusion or reoxygenation (20 min, full O2 supply). At the end of the O2 shortage, the rate-pressure product was less in ischemic than hypoxic hearts (p < 0.0001). The recovery of the rate-pressure product after reperfusion or reoxygenation was not different for t = 20 min, but was better in ischemic than hypoxic hearts for t = 40 and 60 min (p < 0.02 and p < 0.0002, respectively). The end-diastolic pressure remained unchanged during low-flow ischemia (0.024 +/- 0.013 mmHg x min(-1)), but increased significantly during hypoxia (0.334 +/- 0.079 mmHg x min(-1)). We conclude that, while the duration of hypoxia progressively impaired the rate-pressure product and the end-diastolic pressure, hearts were insensitive of the duration of low-flow ischemia, thereby providing evidence that myocardial down-regulation protects hearts from injury. Excessive ATP catabolism during ischemia in non-down-regulated hearts impaired myocardial recovery regardless of vascular, blood-related and neuro-hormonal factors. These observations support the view that protection is mediated by the maintenance of the ATP pool.

Adenosine Triphosphate↗

Preliminary clinical experience with the Heartflo anastomosis device.

UNLABELLED: A clinical, prospective trial to evaluate a multi-suture anastomotic device (Heartflo) is currently underway. This new surgical tool can be used during CABG to perform end-to-side or side-to-side coronary arteries anastomoses with interrupted suture technique. This reports our interim preliminary clinical experience. METHODS: From February to November 2000, we attempted 15 anastomoses with the multi-suture anastomotic device (Heartflo) in 11 patients with coronary artery disease. RESULTS: 7 males, 4 females, mean age 64 +/- 3 yrs received 15 anastomoses with the device. The target vessels were: 8 RCA, 3 LAD, 4 OM. Mean coronary diameter was 2 +/- 0.3 mm. Grafts used were 14 saphenous veins and 1 IMA. 13/15 anastomoses were completed with the device. 5/13 required 0 - 1 additional stitches versus 8/13 requiring more due to inappropriate tissue capture on the native coronary side. Average time was 17.7 +/- 2 min. In 2/15 cases, the procedure was converted to a traditional handsaw anastomosis. Postoperative CK movement without Q-wave in the EKG was observed in 1/11 patients. CONCLUSIONS: This device is a reliable instrument that provides reproducible coronary anastomoses with interrupted suture technique, although it also requires additional measures to improve tissue capture and process of handling sutures before extensive clinical application.

Aged↗

Surgery for congenital heart disease.

General agreement has been reached on the indications for treating most congenital cardiac malformations. Strong disagreement exists, however, about timing and methods of treatment, either for congenital heart defects, for which the approach should be standardized after years of use, and even more when a new technique or a new approach is introduced to replace the existing ones. The ideal solution should be to perform prospective, randomized studies, with long-term follow-up, possibly with preliminary experimental studies to support the hypothesis. Unfortunately this is rarely possible, either because of the nonreproducibility of the malformation in an experimental environment, or because prospective, randomized studies with adequate follow-up are rarely feasible, due to the relatively small number of children with the same congenital heart defect. An updated review of the current trends in congenital heart surgery, based on the papers published in the past year, is presented here.

Airway Obstruction↗

Modified Blalock-Taussig shunt with compensatory properties.

Determination of the proper length of the tubular prosthesis is a major issue when performing a systemic-pulmonary artery shunt. The procedure is simplified by using a prosthesis with accordionlike properties. This was demonstrated in 7 consecutive infants with complex congenital heart defects, in whom systemic-pulmonary artery shunts were placed without early or late complications.

Blood Vessel Prosthesis Implantation↗

Divided right atrium. Diagnosis by echocardiography, and considerations on the functional role of the Eustachian valve.

A child presented at birth with severe cyanosis. Echocardiography showed hypoplasia of the right heart with a right-to-left shunt at atrial level. A conservative approach was adopted initially, and the situation improved over a few months, with reversal of the atrial shunt. Surgery was successfully performed at 4 years of age after further echocardiography revealed a congenitally large Eustachian valve and an atrial septal defect.

Child, Preschool↗

Impact of a remote pump head on neonatal priming volumes.

Reduction of priming volumes of the cardiopulmonary bypass (CPB) circuit in neonatal cardiac surgery to decrease haemodilution and blood transfusion requirements can be achieved with the use of neonatal low prime oxygenators and smaller diameter tubing. We have further reduced our prime volume with the use of a custom-designed arm allowing for remote positioning of a double-headed roller pump. This arm enables the double pump to be placed alongside the main heart-lung machine close to the operating table, and to position the pump inlet and outlet tubing immediately at the reservoir outlet and oxygenator inlet, respectively, therefore reducing tubing lengths. Priming volumes of four cases using this configuration were compared to four cases using our standard neonatal bypass setup. Results showed a 29% decrease in priming volume and a 58% reduction in blood utilization during CPB. This reduction in priming volume is clinically significant as it lowers the ratio of priming volume to patient blood volume and reduces homologous blood requirements.

Cardiopulmonary Bypass↗