Search PubMedSearch

Biomedical subjects

A E Hamblin

Publications and source records attributed to A E Hamblin.

5 recordsLinked to original sources

Complement and contrast material reactors.

Patients showing systemic reactions to intravascular contrast media and patients receiving contrast media without reaction have significantly different mean values (p is less than 0.05) for functionally determined serum C1-esterase inhibitor (C1 INH) and total hemolytic complement (CH50). The lower concentration of these components in reactors appears in baseline serum samples (as well as after injection), and suggests that many anaphylactoid reactions to contrast media are conditioned by earlier complement consumption, and result directly from contrast-induced activation of complement, and other activation system components in the presence of inhibitor depression.

Complement C1 Inactivator Proteins

Complement and coagulation: causative considerations in contrast catastrophies.

Earlier studies suggest that adverse reactions to injected radiographic contrast media are idiosyncratic. In an attempt to gain a better understanding of pathophysiologic events underlying these reactions, rabbit models injected with lethal dose ranges of a cholangiographic contrast material were studied. These animals showed activation of both the complement and coagulation systems. Externally applied heat potentiated complement consumption and increased mortality. Depleting complement components C3-C9 by cobra venom factor did not prevent activation of coagulation or diminish mortality. However, depleting fibrinogen diminished complement activation and markedly diminished mortality. Heparin, administered at several hourly intervals after contrast challenge, also diminished mortality. These studies suggest that the adverse effects of contrast media in this model system are mediated chiefly by the coagulation system, and that complement, if it participates deleteriously, must involve components up to, but not including, C3. A logical role for the inhibitor of C1 esterase in adverse contrast reactions is considered.

Ancrod

Contrast and electrolyte dynamics of the intravenous pyelogram. I. Urinary pH and volume changes in the canine I. V. P.

Canine peripheral venous or suprarenal aortic injections of sodium or meglumine iothalamate produced a significant swing towards an alkaline urine only in individual dogs injected with meglumine salts. When mean values were compared for the sodium or meglumine groups as a whole, however, no significant differences could be established for pH change or induced diuresis. With both salts, ATPase inhibition could play a role in urinary electrolyte excretion. Carbonic anhydrase inhibition does not seem to play a significant role in urinary pH changes induced by contrast media.

Acetazolamide

Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In addition, there seems to be some evidence for both tubular absorption and tubular excretion of meglumine as a minor component in the renal excretion of this ion. No significant differences could be demonstrated for either urinary load or concentration when the sodium salts of iothalamate were compared to the methylglucamine salts.

Animals

Effect of endotoxemia on contrast media reactions.

Since complement activation is sharply temperature-dependent, we have examined the effects of fever produced by a very small dose of endotoxin on contrast media lethality in rabbits. After the injection of 8.2 ml/kg of 52% methylglucamine iodipamide, a group of rabbits exhibiting an average temperature elevation of 1.5 degrees C had a 100% mortality rate. This was contrasted to a 30% mortality in control rabbits receiving contrast alone, and no mortality in rabbits receiving endotoxin alone. The rabbits with fever and increased mortality exhibited increased activation of serum complement. From this preliminary data it appears that caution should be observed in performing a contrast examination in a patient with endotoxemia and/or a fever.

Animals