Search PubMed⌕ Search

Biomedical subjects

A E Goodship

Publications and source records attributed to A E Goodship.

At least 73 records · Page 4Linked to original sources

Treatment of acute superficial digital flexor tendon injury in horses with polysulphated glycosaminoglycan.

Horses with acute injuries of the superficial digital flexor tendon were treated with a course of seven intramuscular injections of 500 mg of polysulphated glycosaminoglycan at four-day intervals. Clinical assessments of the lesions were made by a veterinary surgeon at the time of each injection and 14 and 28 days after the last injection. A total of 150 courses of the drug were administered and adequately completed assessment forms were returned for 80 cases. Long-term follow-up data were obtained for 19 cases. The subjective assessments by the veterinary surgeons showed that in 80 per cent of cases the drug was felt to be of value in the treatment of acute tendon injury.

Animals↗

Parameters of forelimb ground reaction force in 48 normal ponies.

Recordings of forelimb ground reaction forces were made from 48 normal ponies moving at the trot, to evaluate the relationships between bodyweight, vertical ground reaction forces, the timing of individual events within the stance phase and the total contact time. There were highly significant correlations between the mean vertical ground reaction forces and bodyweight. The mean vertical ground reaction forces, corrected for bodyweight, were inversely correlated with the total contact time suggesting that higher trotting speeds may be associated with greater vertical ground reaction forces. The ponies' bodyweights were positively correlated with the contact time, implying a reduced stride frequency with increasing size. The ground reaction force events in the mid and late stance phases occurred at consistent fractions of the total stance time. The ground reaction forces and time parameters were highly symmetrical.

Animals↗

Stress protection due to external fixation.

Bone is sensitive to mechanical influences. The presence of an orthopaedic device will impose constraints on the mechanical environment that may influence subsequent remodelling and repair. An Oxford External Fixator was applied to six intact ovine tibiae. The strains engendered during normal walking were then recorded from strain gauges applied to the mid-shaft of the bone. The fixator configuration was then altered such that the intact fixator bar connecting the pins was replaced with a sectioned version that did not permit load transfer through the fixator, and the strain environment re-recorded. The peak strains recorded with the intact bar were significantly lower than those recorded with the sectioned bar. This showed that the use of a fixator with an intact bar resulted in significant stress protection of the underlying bone. A fixator was then applied to both the right and left tibiae of a further six animals and the resulting strain environment and corresponding remodelling response was observed over 16 weeks. In each case one fixator was configured with an intact bar (the stress protected limb), whilst the other utilised a sectioned bar (the unprotected limb). The results showed that over this period the bone mineral content fell by 9% in the stress protected limb compared to the unprotected limp. Quantitative assessment of the bones showed that this bone loss occurred as a direct consequence of resorption on the periosteal and endosteal surfaces. In addition, strain recordings at week 16 showed that the fixator was still stress protecting the tibia.

Animals↗

The response of the skeleton to physical training: a biochemical study in horses.

In this study we tested the hypothesis that exercise induces an adaptive response in the developing skeleton which may be monitored in vivo by measuring biochemical markers of bone metabolism. The effects of exercise on two biochemical markers of bone formation were determined; the carboxy-terminal propeptide of type I procollagen (PICP), and the bone-specific isoenzyme of alkaline phosphatase (BAP), and one putative marker of resorption, the pyridinoline crosslinked telopeptide domain of type I collagen (ICTP). All three markers were measured for a year in 2-year-old thoroughbred horses exercised three times a week on a treadmill, and values compared to a control group of age-matched animals. Levels of all three markers fell in both exercised and control groups over the 12-month period reflecting normal age changes. However, there were differences between groups in the pattern of this decrease. When expressed as a percentage of baseline values, BAP was higher (p < 0.05) at 2 months and both BAP and the PICP were higher at 4 months (p < 0.01 and p < 0.05, respectively) in the exercised group, reflecting an increase in bone turnover in this group in the early stages of training. PICP levels were also elevated in the exercised group at 10 months and this result indicates an increase in bone turnover at this time. The changes in ICTP were different; at 2 months, levels were higher in exercised animals than in controls, but there was no significant difference between the two groups at 4 and 6 months. After 8 months, ICTP levels in the exercised group increased returning to near baseline values at 10 months.(ABSTRACT TRUNCATED AT 250 WORDS)

Alkaline Phosphatase↗

Age related changes in biochemical markers of bone metabolism in horses.

Biochemical markers of bone metabolism were analysed in serum samples obtained from 60 horses with no history of orthopaedic disease (age 3 months-20 years). Serum levels of the carboxyterminal propeptide of type I procollagen (PICP), a marker of bone formation and the pyridinoline cross linked telopeptide domain of type I collagen (ICTP), a putative marker of bone resorption, were measured by radioimmunoassay (RIA). Serum levels of the bone specific isoenzyme of alkaline phosphatase (BALP), another marker of bone formation, were measured by a wheatgerm agglutinin affinity (WGA) method. Total alkaline phosphatase levels were also determined. Serum levels of PICP were significantly correlated with bone ALP (r = 0.78, P < 0.0001) and ICTP (r = 0.87, P < 0.0001). ICTP levels also correlated significantly with bone ALP (r = 0.81, P < 0.0001). However, total alkaline phosphatase did not correlate significantly with PICP, ICTP and BALP in horses over 1 year of age. There was an inverse correlation between serum levels of all biochemical markers and age of animals, with the most significant changes seen over the first 2 years. In animals less than 1 year of age, the reference ranges (mean +/- s.d. 1.96) were as follows: PICP 1216-2666 micrograms/l, ICTP 13.8-26.7 micrograms/l, bone ALP 134-288 u/l and total ALP 223-498 u/l. In 2-year-olds, the equivalent reference ranges were: PICP 550-1472 micrograms/l, ICTP 7.96-22.8 micrograms/l, bone ALP 32.7-125 u/l and total ALP 134-238 u/l.(ABSTRACT TRUNCATED AT 250 WORDS)

Aging↗

Exercise-induced hyperthermia as a possible mechanism for tendon degeneration.

Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E. +/- 1.0) degrees C was demonstrated in vivo in four horses. Peak intra-tendinous temperatures in the range 43-45 degrees C were recorded. Temperatures above 42.5 degrees C are known to result in fibroblast death in vitro [Hall (1988) Radiobiology for the Radiologist, 3rd Edn., pp. 294-329]. These in vivo recordings provide a possible aetiology for the degenerative changes that are observed in the central core of tendons in both equine and human athletes.

Achilles Tendon↗

The pathobiology and repair of tendon and ligament injury.

Injury of the collagenous structures comprising tendons and ligaments, either from acute trauma or from repetitive strain lesions, results in protracted periods of disability. The resolution of such injuries often fails to restore the normal morphologic and functional characteristics of the structure and, therefore, either compromises the future performance of the individual or predisposes to an increased risk of recurrent injury.

Animals↗

Effect of central or marginal location and post-operative exercise on the healing of osteochondral defects in the equine carpus.

The effects of osteochondral defect location and post-operative walking exercise on structural repair and recovery of joint function were examined in the midcarpal joints of ponies. Functional recovery was monitored by measuring ground reaction forces using a force plate. Structural repair was evaluated histologically and by measuring the total collagen and uronic acid content and relative proportions of Type I and II collagen in the repair tissue. Central defects tended to cause a more marked functional disturbance but were repaired with fibrocartilage rather than fibrous tissue in 3 out of 6 ponies while marginal defects were repaired almost exclusively with fibrous tissue. There was no significant difference between defect locations with regard to the biochemical measures evaluated. Exercise produced no beneficial effect on structural repair of the defects. Secondary 'kissing' lesions in the third carpal bones opposite the defects appeared grossly more severe in the exercised ponies which also showed a trend to more marked functional disturbance.

Animals↗

Use of a bisphosphonate (pamidronate) to modulate fracture repair in ovine bone.

Bisphosphonates influence the morphology and mechanical properties of bones in growing rats, but their effects on fracture repair are not well documented. This study tests the hypothesis that bisphosphonates will modulate the remodelling phase of fracture repair, influencing the mechanical properties of healing bone. The effects of a bisphosphonate (pamidronate, Aredia) on the healing of a 3 mm osteotomy gap in the mid-diaphysis of the tibia, under rigid unilateral external fixation, were evaluated using 2 groups of 6 skeletally mature sheep. The repair process was evaluated weekly for 12 weeks using conventional radiographs, dual photon absorptiometry, and fracture stiffness measurements. The animals were then killed and the torsional stiffness and strength of the tibiae measured. More prolific callus formation, with an associated rise in the rate of bone mineral content, was observed in the treated group. There were no differences in in vivo fracture stiffness or postmortem torsional stiffness between the 2 groups, but torsional strength was greater in the treated group. Callus remodelling was reduced but not arrested in the treated group. Bisphosphonates act to reduce callus remodelling, leading to an increased amount of bridging callus and therefore strength. This study indicates that pamidronate has no adverse effects on the restoration of the mechanical integrity of a long bone after fracture.

Animals↗

Measuring stiffness can define healing of tibial fractures.

We measured fracture stiffness in 212 patients with tibial fractures treated by external fixation. In the first 117 patients (group 1) the decision to remove the fixator and allow independent weight-bearing was made on clinical grounds. In the other 95 patients (group 2) the frames were removed when the fracture stiffness had reached 15 Nm/degree. In group 1 there were eight refractures and in group 2 there was none (p = 0.02, Fisher's exact test). The time to independent weight-bearing was longer in group 1 (median 24 weeks) than in group 2 (21.7 weeks, p = 0.02). The greater precision of our objective measurement was associated with a reduction in refracture rate and in the time taken to achieve independent weight-bearing. We consider that a stiffness of 15 Nm/degree in the sagittal plane provides a useful definition of union of tibial fractures.

Biomechanical Phenomena↗

Can intervertebral disc prolapse be predicted by disc mechanics?

The hypothesis was tested that stress concentrations in the posterior anulus of an intervertebral disc predispose it to prolapse under high compressive loads and anterolateral bending. The distribution of compressive stress inside the intervertebral discs of 22 cadaveric lumbar motion segments was measured with the specimens loaded in pure compression and in compression combined with anterolateral bending. Each motion segment was then loaded to failure in combined compression and anterolateral bending. Failure occurred in the vertebral body (n = 12) or posterolateral anulus (n = 10); the latter group showed a significantly greater incidence of stress concentrations (P < 0.001) in the posterior anulus, when loaded in compression and bending. It was concluded that some discs are predisposed to prolapse because of damaging, localized concentrations of stress in the posterior anulus in combined anterolateral bending and compression.

Cadaver↗

Analgesic effects of detomidine in thoroughbred horses with chronic tendon injury.

This study was undertaken to assess the analgesia provided by detomidine (20 micrograms kg-1 intravenously) in thoroughbred horses. Pain thresholds to a mechanical noxious stimulus were measured before and after a period of mild chronic pain in one foreleg. Detomidine was a good analgesic in control animals; their pain thresholds were significantly elevated for about 60 minutes. After injury, the injured leg had a significantly lower pain threshold and the intensity and duration of analgesia provided by detomidine were significantly reduced. The analgesia in the opposite (sound) leg was also reduced, indicating that there were both central and peripheral aspects to this increased sensitivity to painful stimuli. Detomidine deserves to be considered as a potent analgesic in the horse rather than a sedative with analgesic side effects.

Analgesics↗

The role of fixator frame stiffness in the control of fracture healing. An experimental study.

External skeletal fixation is used widely in the management of fractures. Frame configuration is known to affect frame stiffness and, thereby, the local mechanical environment at the fracture site. In previous investigations of the influence of mechanical conditions upon fracture healing, the frames have always been applied so that they influence the biological environment in different ways. As a result, the influence of stiffness, per se, could not be studied as a single variable, and its effect on the repair process remains unclear. In this study, using a standard osteotomy of the ovine tibia, stabilised by an external skeletal fixator, the local mechanical environment was altered solely by increasing the 'offset' distance between the bone and the fixator frame. The biological conditions at the fracture remained identical in both groups. Increasing the frame stiffness by 40%, brought about by reducing the offset distance of the fixator bar by 10 mm, caused a significant reduction in the rate of healing. In addition, the frame stiffness influenced the ground reaction force with greater weight-bearing in the initial stages in the more rigid group, but despite this, the resultant interfragmentary displacement in this group appeared to be insufficient to stimulate fracture healing. This work emphasises the importance of the local mechanical environment on the process of fracture healing. It also demonstrates the value of in vivo assessment of fracture stiffness as a means of monitoring mechanical events during fracture healing.

Animals↗

Functional significance of the morphology and micromechanics of collagen fibres in relation to partial rupture of the superficial digital flexor tendon in racehorses.

The high incidence of partial rupture of the superficial digital flexor tendor in the equine athlete represents a major cause for concern in the racing industry. Frequently, the lesion is localised to the central core of the tendon. This study tested the hypothesis that the site specific structural failure results from differences in the collagen fibre morphology and associated micromechanics between central and peripheral regions of the tendon. Bundles of collagen fibres were dissected from central and peripheral sites in the mid-metacarpal region of the tendon. Crimp morphology was quantified by polarised light microscopy and mechanical characteristics determined using a fibre tensometer. In older horses, centrally located fibres showed significantly lower values for crimp angle, crimp length and toe limit strain than seen peripherally. There were no significant differences in these features between corresponding sites in the younger horses. No significant difference between sites was found in elastic modulus in either group. These data indicate a non-uniform functional stress distribution which may result from ageing or be related to the exercise history as a feature of accumulated damage. These observations may explain the location of central core lesions seen on clinical examination.

Aging↗