Ventricular fibrillation in patients without significant structural heart disease: a multicenter experience with implantable cardioverter-defibrillator therapy.

OBJECTIVES: This study was undertaken to characterize the outcome of survivors of ventricular fibrillation with no or minimal structural heart disease who received an implantable cardioverter-defibrillator. BACKGROUND: The prognosis among survivors of ventricular fibrillation with minimal or no structural cardiac abnormalities remains unclear. Since the advent of implantable cardioverter-defibrillators, this question takes on added importance. METHODS: This 10-center retrospective study provided information on 28 survivors of ventricular fibrillation (mean age 42 years) with minimal or no structural abnormalities who were treated with an implantable cardioverter-defibrillator. RESULTS: Ventricular tachyarrhythmias (polymorphic in all but one patient) were induced during baseline programmed stimulation in 39% of patients. During a median 30.6-month follow-up period after implantable cardioverter-defibrillator implantation, there were no cardiac deaths and two noncardiac deaths. Sixteen patients experienced 36 shock episodes (total 88 shocks). The majority of shocks were classified as "indeterminate"; one patient received 47 "spurious" shocks during one shock episode and each of four patients received one "appropriate" shock. Ventricular arrhythmias were not inducible in any of these latter four patients. CONCLUSIONS: Survivors of ventricular fibrillation with minimal or no structural cardiac abnormalities receiving an implantable cardioverter-defibrillator have an excellent 3-year survival rate. The occurrence, albeit infrequent, of appropriate implantable cardioverter-defibrillator shocks in this group suggests that these patients have a potential risk of recurrent cardiac arrest whose fatal outcome may be avoided by implantable cardioverter-defibrillator therapy.

Actuarial Analysis↗

Failure of one conductor in a nonthoracotomy implantable defibrillator lead causing inappropriate sensing and potentially ineffective shock delivery.

We describe how a single defect in a new model transvenous lead for an implantable cardioverter defibrillator can result in malfunction of the sensing and defibrillation circuits. The patient had received shocks during atrial fibrillation without premonitory symptoms. At least one shock was delivered and not felt by the patient. In addition, late in the course, a shock was delivered during atrial fibrillation documented to be with a slow ventricular response. In the transvenous lead, a distal spring functions as the anode for rate sensing and the cathode for defibrillation. The wire from this spring bifurcates near the proximal end of the catheter. One wire from the bifurcation leads to the positive (anode) rate-sensing socket of the pulse generator, and the other wire leads to the negative (cathode) high voltage output socket of the defibrillator for defibrillation and cardioversion. After the inappropriate and unperceived shocks were documented, intraoperative and postoperative electrical testing indicated that intermittent discontinuity of the distal spring system within the proximal yoke of the catheter caused faulty sensing and potentially unreliable defibrillation. This dual malfunction was possible because the distal spring of the lead functions in the high-voltage output and the rate-sensing low-voltage input circuits of the implantable defibrillator.

Defibrillators, Implantable↗

AVID necessity.

Explore the source record for details and available documents.

Amiodarone↗

Role of radiofrequency ablation in the management of supraventricular arrhythmias: experience in 760 consecutive patients.

INTRODUCTION: Several reports have demonstrated that radiofrequency catheter ablation provides effective control of a variety of supraventricular tachycardias. However, the efficacy, complications, risk of arrhythmia recurrence, and follow-up survival analysis have not been reported in a large series of consecutive patients with supraventricular arrhythmias with diverse electrophysiologic mechanisms. This report details the results of radiofrequency catheter ablation in 760 consecutive patients (386 males, 374 females) with a wide variety of supraventricular tachycardias treated at one center. METHODS AND RESULTS: Arrhythmias were associated with the presence of an accessory pathway in 363 patients (384 accessory pathways), including four patients with Mahaim fibers and eight patients with the permanent form of junctional reciprocating tachycardia. The mechanism of the clinical arrhythmia was AV nodal reentrant tachycardia in 245 patients, and a primary atrial tachycardia in 20 patients (ectopic atrial tachycardia in 16 patients and sinus nodal reentry in 4 patients). Ablation of the reentrant circuit of atrial flutter within the right atrium was attempted in 13 patients. AV node ablation and permanent pacemaker implantation were performed in 119 patients with medically refractory atrial fibrillation or flutter. Radiofrequency catheter ablation was successful in 346 of 363 patients (95.3%, CI 93.1%-97.5%) with accessory pathways (367 of 384 pathways, 95.6%, CI 93.5%-97.6%) with a complication rate of 1.1% and a recurrence rate of 5.5%. Successful accessory pathway ablation was achieved for 179 of the first 192 pathways treated (93.2%, CI 89.7%-96.6%) and increased to 188 of 192 pathways (97.9%, CI 95.9%-99.9%) over the second half of the series. AV nodal reentry was successfully abolished in 244 of 245 patients (99.6%, CI 98.8%-100%) by selective ablation of the slow pathway in 234 patients and the fast pathway in 10 patients. The complication rate in this group was 2.0% with a recurrence rate of 6.5%. All 20 primary atrial tachycardias were successfully ablated with no complications and a recurrence rate of 15%. The reentrant circuit of atrial flutter was ablated successfully in 10 of 13 patients (77%) with recurrent atrial flutter in one additional patient. Complete AV block was achieved in 117 of 119 (98.3%, CI 96.0%-100%) patients with atrial fibrillation or flutter treated by AV nodal ablation with a complication rate of 0.8% and recurrence of AV conduction in 6%. The median duration of fluoroscopy exposure for the population was 23.4 minutes. The overall primary success rate for the entire population was 97.0% (737 of 760 patients, CI 95.8%-98.2%). CONCLUSION: Thus, the results of this large series of patients demonstrates the safety and efficacy of radiofrequency ablation for the treatment of a wide variety of supraventricular arrhythmias. It also appears that increasing experience with these procedures increases the rate of successful ablation and decreases the risk of complications.

Adolescent↗

Evaluation of the acute hemodynamic and electrophysiologic effects of intravenous amlodipine alone and in combination with a beta-blocker in patients with angina pectoris.

The acute hemodynamic and electrophysiologic effects of intravenous amlodipine (2 x 10 mg), administered either alone or on a background of beta-blocker therapy, were studied in 25 patients with angina pectoris. Hemodynamic assessments showed that amlodipine produced significant decreases in systemic vascular resistance and systemic blood pressure, and increases in stroke volume and cardiac output in both treatment groups. Electrophysiologic evaluation revealed that neither sinus node function, nor HIS ventricular conduction, were altered with amlodipine. Therefore, acute intravenous administration of amlodipine alone or in combination with a beta-blocker does not appear to compromise left ventricular performance, sinus node function, or intracardiac conduction.

Adrenergic beta-Antagonists↗

Intracoronary ethanol ablation for the treatment of recurrent sustained ventricular tachycardia.

The selective infusion of ethanol into the coronary circulation supplying the site of origin of incessant ventricular tachycardia has been demonstrated to abolish this arrhythmia in selected patients. The present study was designed to evaluate the efficacy and safety of the intracoronary ethanol ablation technique in patients with paroxysmal ventricular tachycardia related to prior myocardial infarction. Twenty-three patients with sustained monomorphic ventricular tachycardia that was refractory to conventional antiarrhythmic drug therapy were prospectively studied. After induction of ventricular tachycardia by programmed electrical stimulation, the response of the arrhythmia to the infusion of radiographic contrast medium or saline solution into the ostia of the native coronary arteries and coronary artery bypass grafts was assessed. If ventricular tachycardia was reliably interrupted by injections into the proximal coronary artery or bypass graft, the vessel was cannulated with a steerable guide wire and 2.7F infusion catheter to determine the smallest arterial branch that would result in termination of the arrhythmia with selective injections. If reliable interruption of ventricular tachycardia was observed with saline or contrast injections, ethanol (2 ml) was then delivered through the infusion catheter. Ventricular tachycardia could be terminated by injections of saline solution or contrast medium in 11 of 21 patients in whom the protocol could be completed. Ethanol was infused in 10 of these patients. Ventricular tachycardia was inducible in only 1 of 10 patients immediately after ethanol infusion. At a follow-up electrophysiologic study performed 5 to 7 days after ablation, ventricular tachycardia became inducible in two other patients, in one of whom the arrhythmia substrate was successfully ablated after three sessions. The mean left ventricular ejection fraction was 0.33 +/- 0.1 before and 0.35 +/- 0.11 after ablation. Complications of the procedure included complete atrioventricular block in four patients and pericarditis in one patient. Thus, intracoronary ethanol ablation is associated with a moderate degree of efficacy but the potential for important complications. Despite these limitations, this technique may provide effective long-term control of ventricular tachycardia for some patients.

Aged↗

Modification of late potentials by intracoronary ethanol infusion.

Antiarrhythmic drugs have no consistent effects on the signal-averaged electrocardiogram (ECG) while successful surgical ablation of ventricular tachycardia is known to abolish late potentials. Ten patients with prior myocardial infarction had successful ablation of recurrent sustained ventricular tachycardia by selective ethanol infusion into a small coronary vessel supplying the tachycardia origin. Signal-averaged ECGs were performed before and after initially successful ablation in patients without pacemaker dependence or intraventricular conduction delay to assess the effects on late potentials and to determine if the signal-averaged ECG could predict ventricular tachycardia recurrence. Only four of ten patients were eligible for study and all four had late potentials prior to ethanol ablation. Late potentials were abolished in one patient who has not had an arrhythmia recurrence in 25 months. One patient with sudden death and another patient with ventricular tachycardia recurrence had persistent late potentials post procedure that were modified by a reduction in terminal voltage and lengthening of terminal low amplitude signal. The fourth patient who receives chronic amiodarone had no arrhythmia recurrence in spite of persistent but modified late potentials. Thus, the abolition of late potentials after ethanol ablation may predict freedom from arrhythmia recurrence.

Cardiac Pacing, Artificial↗

Can the heart be chronically paced with electrodes on the pericardial surface?

During implantable defibrillator (ICD) operations, we measured acute and chronic transpericardial bipolar pacing thresholds through standard myocardial surface electrodes sewn on the pericardium for chronic ICD QRS rate-sensing use. We compared observations in 24 patients on day 0 with chronic measurements in seven patients at 27.4 +/- 12.1 (median 31.7) months. The leads were used only for QRS rate-sensing, not for pacing, during the time between acute and chronic measurements. Acute transpericardial pacing threshold at 0.5-msec stimulus duration on day 0 was 4.5 +/- 2.19 V (standard deviation), median 3.5 V, and at median time 964 days postimplantation was 3.8 +/- 2.07 V, median 3.5 V. Mean acute pacing current threshold was 3.7 +/- 1.90 mA, n = 23, and chronic was 2.7 +/- 1.79 mA, n = 6. Acute bipolar impedance was 1,209 +/- 383 ohms, median 1,138 ohms, and chronic was 1,550 +/- 358 ohms, median 1,410 ohms, n = 7. Acute bipolar QRS amplitude was 12.3 +/- 5.93 mV, median 12.1 mV, n = 24, and chronic was 13.5 +/- 8.5 mV, median 17.2 mV, n = 7. None of the changes between the acute and chronic states was statistically significant, with the exception of bipolar impedance (P = 0.054). We concluded that: (1) transpericardial pacing threshold did not increase with time; (2) initial and chronic pacing impedances were high and current low; (3) QRS amplitudes were highly satisfactory for defibrillator rate-sensing; and (4) this approach to ICD implantation left the surgically virgin heart unscarred to make future transplantation easier, and enhanced safety when previous cardiac operations had been done.

Cardiac Pacing, Artificial↗

Gross and microscopic changes associated with a nonthoracotomy implantable cardioverter defibrillator.

The pathology associated with an investigational transvenous defibrillating and sensing lead is described. The lead system had delivered a total of 865 J from the time of implantation to the time of patient death from a noncardiac cause 7 months after implantation and 1 month after his last defibrillator shock. There was mild, superficial fibrous thickening on the endothelial surface of the superior vena cava adjacent to the proximal spring electrode, which did not extend into the vessel wall. The distal portion of endocardial lead was embedded in the interventricular septum near the apex of the right ventricle, surrounded by fibrous thickening, and partially covered by endocardial tissue. Microscopically, there was a thick bed of fibrous connective tissue surrounding the lead with extensive interstitial fibrous connective tissue radiating into the adjacent myocardium. Since this pattern is different from the more generalized fibrotic scarring produced by myocardial infarction, we speculate that the mechanism for the observed interstitial fibrosis is replacement fibrosis following acute myocyte injury that resulted from prior defibrillator shocks and possibly from the trauma produced by the lead compressing adjacent myocardium during systole. Potential effects on device efficacy of these fibrotic changes at the bioelectric interface include their representing a new arrhythmia substrate, the possibility that fibrosis could increase both defibrillation and pacing thresholds, and that the inflammatory reaction may cause deterioration of intracardiac electrograms and interfere with sensing and tachycardia recognition.

Aged↗

Selective radiofrequency ablation of the slow pathway for the treatment of atrioventricular nodal reentrant tachycardia. Evidence for involvement of perinodal myocardium within the reentrant circuit.

BACKGROUND: The circuit of atrioventricular (AV) nodal reentrant tachycardia may include perinodal atrial myocardium. Furthermore, in patients with dual AV nodal pathways, the atrial insertion of the slow pathway is likely to be located near the ostium of the coronary sinus, caudal to the expected location of the AV node. The present study was designed to evaluate the safety and efficacy of selective catheter ablation of the slow pathway using radiofrequency energy applied along the tricuspid annulus near the coronary sinus ostium as definitive therapy for AV nodal reentrant tachycardia. METHODS AND RESULTS: Among 34 consecutive patients who were prospectively enrolled in the study, the slow pathway was selectively ablated in 30, and the fast pathway was ablated in four. Antegrade conduction over the fast pathway remained intact in all 30 patients after successful selective slow pathway ablation. There was no statistically significant change in the atrio-His interval (68.5 +/- 21.8 msec before and 69.6 +/- 23.9 msec after ablation) or AV Wenckebach rate (167 +/- 27 beats per minute before and 178 +/- 50 beats per minute after ablation) after selective ablation of the slow pathway. However, the antegrade effective refractory period of the fast pathway decreased from 348 +/- 94 msec before ablation to 309 +/- 79 msec after selective slow pathway ablation (p = 0.005). Retrograde conduction remained intact in 26 of 30 patients after selective ablation of the slow pathway. The retrograde refractory period of the ventriculo-atrial conduction system was 285 +/- 55 msec before and 280 +/- 52 msec after slow pathway ablation in patients with intact retrograde conduction (p = NS). There were three complications in two patients, including an episode of pulmonary edema and the development of spontaneous AV Wenckebach block during sleep in one patient after slow pathway ablation and the late development of complete AV block in another patient after fast pathway ablation. Over a mean follow-up period of 322 +/- 73 days, AV nodal reentrant tachycardia recurred in three patients, all of whom were successfully treated in a second ablation session. CONCLUSIONS: Radiofrequency ablation of the slow AV pathway is highly effective and is associated with a low rate of complications.

Adult↗

Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study.

BACKGROUND: Successful defibrillation by an implantable cardioverter-defibrillator (ICD) depends on its ability to deliver shocks that exceed the defibrillation threshold. This study was designed to identify clinical characteristics that may predict the finding of an elevated defibrillation threshold and to describe the outcome of patients with high defibrillation thresholds. METHODS AND RESULTS: The records of 1,946 patients from 12 centers were screened to identify 90 patients (4.6%) with a defibrillation threshold greater than or equal to 25 J. Excluding three patients who received ICDs that delivered greater than 30 J, there were 81 men and six women with a mean age of 59.5 +/- 10.1 years, a mean left ventricular ejection fraction of 0.32 +/- 0.14, and a 76% prevalence of coronary artery disease. Sixty-one patients (70%) were receiving antiarrhythmic drugs, and 45 (52%) were receiving amiodarone. Seventy-one patients (82%) received an ICD. Death occurred in 27 patients--19 of the 71 (27%) with an ICD (eight arrhythmic), and eight of the 16 (50%) without an ICD (four arrhythmic). Actuarial survival for all patients at 5 years was 67%. Actuarial survival rates at 2 years for patients with and without an ICD were 81% and 36%, respectively (p = 0.0024). Actuarial survival at 5 years for the ICD patients was 73%; no patient without an ICD has lived longer than 32 months. Actuarial survival free of arrhythmic death in the ICD patients at 5 years was 84%. Although the only variable to predict survival was ICD implantation (p = 0.003), it is entirely possible that in this retrospective analysis, clinical selection decisions to implant or to not implant an ICD differentiated patients destined to have better or worse outcomes, respectively. CONCLUSIONS: Antiarrhythmic drug use may be causally related to the finding of an elevated defibrillation threshold. When patients with high defibrillation thresholds receive an ICD, arrhythmic death remains an important risk (42% of deaths in these patients were arrhythmia related, with 16% actuarial incidence at 5 years). Vigorous testing to optimize patch location can potentially benefit patients by enhancing the margin of safety for effective defibrillation.

Adult↗

Wolff-Parkinson-White syndrome. A quantitative morphometric analysis of surgical anatomy.

Previous descriptions of the four anatomic regions of dissection in Wolff-Parkinson-White syndrome have been largely qualitative. In this study quantitative data describing this anatomy are presented, together with statistical analysis of selected anatomic relationships. Fourteen human hearts were dissected. The borders of the posteroseptal dissection along the mitral anulus, tricuspid anulus, and epicardium were measured. A positive correlation between the mitral and tricuspid annular dimensions was found (r = 0.55; p = 0.04); however, the length of epicardial dissection was more variable. The dimensions of the anteroseptal space and the position of the right coronary artery within this space were measured. These measurements emphasize the proximity of the aortic sinuses of Valsalva to the right atrial endocardium near the posteromedial extent of the dissection. The dimensions of the right and left free walls and the position of the coronary arteries within these spaces were measured. A positive correlation was found between the width of the atrioventricular groove and the length of the dissection necessary to separate the atrioventricular groove fat from the ventricular surface (r = 0.89; p = 0.0001, right free wall; r = 0.87; p = 0.0001, left free wall). The quantitative data presented in this article are intended to enhance the surgeon's appreciation of the anatomy relevant to the treatment of Wolff-Parkinson-White syndrome. The knowledge gained from this quantitative analysis may improve accuracy in the electrophysiologic localization and surgical disruption of accessory atrioventricular connections.

Autopsy↗

Intermediate septal accessory pathways: electrocardiographic characteristics, electrophysiologic observations and their surgical implications.

Intermediate septal accessory pathways are located in close proximity to the atrioventricular (AV) node and His bundle, have unique features that distinguish them from typical anterior and posterior accessory pathways and have been associated with a high risk for unsuccessful pathway division and the production of complete AV block after surgery. Between July 1986 and May 1990, 4 of 70 patients (3 men and 1 woman; mean age 33 +/- 13 years) undergoing surgery for accessory pathway division were found to have an intermediate septal accessory pathway. The presenting arrhythmia was atrial fibrillation with rapid anterograde conduction over the accessory pathway in two patients and recurrent orthodromic reciprocating tachycardia in two patients. In all patients, the delta wave on the electrocardiogram (ECG) was inverted in lead V1, but two patterns of delta wave configuration were observed. In three patients (type 1 intermediate septal accessory pathway), the delta wave was upright in lead II, inverted in lead III and isoelectric in lead a VF; the transition from a negative to an upright delta wave occurred in lead V2. The fourth patient exhibited a different delta wave pattern (type 2 intermediate septal accessory pathway). The delta wave was upright in each of leads II, III and aVF; the transition from a negative to an upright delta wave occurred at lead V3. Intraoperative electrophysiologic study localized the atrial insertion of type 1 pathways to the midpoint of Koch's triangle close to the AV node.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A prospective evaluation of intracoronary ethanol ablation of the atrioventricular conduction system.

The clinical efficacy and complications associated with ablation of the atrioventricular (AV) conduction system by the selective infusion of ethanol into the AV node artery were prospectively assessed in 12 consecutive patients with medically refractory atrial arrhythmias. Six of the patients had previously failed to have permanent complete AV block created with direct current or radiofrequency catheter ablation. The AV node artery was cannulated with a 0.016 in. (0.041 cm) guide wire in all 12 patients. It was also possible to advance a 2.7F infusion catheter into the AV node artery in all patients. Transient AV block was induced by selective injections into the AV node artery of iced saline solution (8 patients) and of radiographic contrast agent (ioxaglate) (10 patients). The infusion of 2 ml of ethanol (96%) induced immediate complete AV block in all 10 patients who demonstrated AV block with ioxaglate. The escape rhythm exhibited a narrow QRS complex preceded by a His bundle deflection in nine patients and left bundle branch block in one patient. The immediate mean rate of the escape rhythm was 45.3 +/- 13.4 beats/min. In two patients who demonstrated reflux of contrast agent into the distal right coronary artery with selective injections into the AV node artery, transient ST segment elevation developed in the inferior electrocardiographic leads with the infusion of ethanol. There was no change in the left ventricular ejection fraction from the baseline value (0.53 +/- 0.12) to that measured after ablation (0.55 +/- 0.11) and no patient developed wall motion abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Events in the Cardiac Arrhythmia Suppression Trial (CAST): mortality in the entire population enrolled.

To test the hypothesis that suppression of ventricular arrhythmias by antiarrhythmic drugs after myocardial infarction improves survival, the Cardiac Arrhythmia Suppression Trial (CAST) was initiated. Suppression was evaluated before randomization during an open label titration period. Patients whose arrhythmias were suppressed were randomized in the main study and those whose arrhythmias were partially suppressed were randomized in a substudy. Overall survival and survival free of arrhythmic death or cardiac arrest were lower [corrected] in patients treated with encainide or flecainide than in patients treated with placebo. However, the death rate in patients randomized to placebo therapy was lower than expected. This report describes the survival experience of all patients enrolled in CAST and compares it with mortality in other studies of patients with ventricular arrhythmias after myocardial infarction. As of April 18, 1989, 2,371 patients had enrolled in CAST and entered prerandomization, open label titration: 1,913 (81%) were randomized to double-blind, placebo-controlled therapy (1,775 patients whose arrhythmias were suppressed and 138 patients whose arrhythmias were partially suppressed during open label titration); and 458 patients (19%) were not randomized because they were still in titration, had died during titration or had withdrawn. Including all patients who enrolled in CAST, the actuarial (Kaplan-Meier) estimate of 1-year mortality was 10.3%. To estimate the "natural" mortality rate of patients enrolled in CAST, an analysis was done that adjusted for deaths that might be attributable to encainide or flecainide treatment either during prerandomization, open label drug titration or after randomization. Because the censoring procedure excluded patients treated with encainide or flecainide after randomization, the mortality estimate will be less than the unadjusted mortality estimate of 10.3%.(ABSTRACT TRUNCATED AT 250 WORDS)

Anilides↗

Pacing threshold spikes months and years after implant.

To determine patterns of variation in chronic pacing thresholds, we made 4,942 threshold measurements in 257 patients with 312 leads, at times from implant to 295 months (median 17 months) including 1,053 determinations in 46 children less than 12 years old. Motivation was late sudden death in two single-ventricle pacemaker-dependent children with multiple possible death causes. At stimulus duration 0.5 +/- 0.04 msec, mean of the thresholds, measured 1 month or more after implant, was 1.3 +/- 0.66 volts (V) for endocardial electrodes and 2.8 +/- 1.39 V for epicardially applied electrodes. Highest mean thresholds were in the 6 to 12-year-old age group. In 34 leads studied at implant, again within a month and for at least three years thereafter, time of maximum threshold occurred after one month in 59%, independent of lead type or patient age. Of 107 leads with five or more measurements after 3 months use, gradual increase in threshold continued after 3 months in 24%. An additional 21% had at least one threshold that exceeded the post-three-months individual patient lead mean by three standard deviations. Most striking was the occurrence of transient several-volt increases and decreases in threshold as late as 8 years after lead implantation in at least three children. These temporary changes were detected initially transtelephonically by the vario method of threshold measurement. They occurred during minor illnesses such as summer colds, yet similar illnesses also occurred without threshold elevation. We suggest further study of pacing threshold variations in highly pacemaker-dependent children whose cardiac anatomy makes use of epicardial electrodes necessary.

Cardiac Pacing, Artificial↗