Virtual endoscopy in otorhinolaryngology by postprocessing of helical computed tomography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Dessl.
Explore the source record for details and available documents.
Malignant appendix tumours are rare entities. Especially adenocarcinomas, which only appear in about 10% of appendix tumours, are very seldom. Preoperative diagnosis is very difficult due to a lack of typical clinical signs and a clinical appearance mimicking perforated appendicitis. Nevertheless, sonography is able to show indirect signs and therefore it can provide the surgeon with more information for a better operative treatment.
AIM: Evaluation of high resolution ultrasound to diagnose rupture of the medial head of gastrocnemius muscle in patients with uncharacteristic calf pain. METHOD: 66 patients with clinically unclear calf pain were examined in a prospective study. RESULTS: Out of 66 patients, 51 showed sonographic criteria of a partial rupture of the medial gastrocnemius head. 47 ruptures were located in musculotendineus transition zone. CONCLUSION: High resolution sonography detect minimal lesions of the medial gastrocnemius muscle in patients with clinically uncharacteristic calf pain.
PURPOSE: To assess the feasibility of image transfer for teleradiologic consultations using the Austrian Academic Computer Network (ACOnet). The ACOnet corresponds between the main universities to a MAN (Metropolitan Area Network) with a transfer rate of 4 Mbps. Its use is free of charge for university institutions. MATERIALS AND METHODS: 1740 test image data sets and 620 image data sets for teleradiological consultations were exchanged without annotations between the Departments of Diagnostic Radiology of the universities of Innsbruck and Graz, using the ACOnet. RESULTS: Data transmission was reliable and fast with an average transfer capacity of 170.2 kBytes/s (94-341 kBytes/s). There were no major problems with image transfer during the test phase. CONCLUSION: Due to its high transfer capacity, the ACOnet is considered a reasonable alternative to the ISDN service.
Adamantinoma of the long bones is a rare skeletal tumor and its MR features have seldom been reported. It is difficult to distinguish from other bone lesions (such as osteofibrous dysplasia or osteosarcoma) by means of conventional radiography and CT. MR imaging, however, may be useful in differentiating adamantinoma from such lesions. With this presentation of a typical case, we hope to draw the attention of radiologists to this lesion and contribute information on its MR appearance.
To study the value of the Austrian Academic Computer Network (ACOnet) for teleradiology, 1740 test image data-sets and 620 image data-sets were exchanged between the departments of diagnostic radiology of the Universities of Innsbruck and Graz using the ACOnet service. Data transmission was reliable and fast with an average transfer capacity of 170 kByte/s (range 94-341). During the test phase, no major problems with image transfer occurred. Assuming that problems like security of patient data-sets, data compression and data verification can be solved, the ACOnet service would be a useful additional tool for telemedicine applications throughout Austria and eastern Europe.
Explore the source record for details and available documents.
BACKGROUND AND STUDY AIMS: The aim of the present study was to establish a suitable method for virtual computed tomography (CT) gastroscopy. PATIENTS AND METHODS: Three-millimeter helical CT scans of a pig stomach were obtained after air insufflation and instillation of diluted diatrizoic acid (Gastrografin), and with double contrast. In addition, three patients with gastric tumors were studied after ingestion of an effervescent agent (Duplotrast, 6 g) and intravenous injection of hyoscine butylbromide (Buscopan, 1 ml). Virtual endoscopy images were computed on a Sun Sparc 20 workstation (128 megabytes of random access memory, four gigabytes of hard disk space), using dedicated software (Navigator, General Electric Medical System Company). The endoscopy sequences were compared with real endoscopic examinations and with anatomical specimens. RESULTS: In the cadaver studies, the best results were obtained with plain air insufflation, whereas virtual CT gastroscopy with diluted contrast and with double contrast showed artifacts simulating polyps, erosions, and flat ulcers. Patient studies showed good correlation with the fiberoptic endoscopy findings, although large amounts of retained gastric fluid substantially reduced the quality of the surface reconstruction. CONCLUSION: These preliminary results show that virtual CT gastroscopy is able to provide insights into the upper gastrointestinal tract similar to those of fiberoptic endoscopy. However, due to the limited spatial resolution of the CT protocol used, as well as inherent image artifacts associated with the Navigator program's reconstruction algorithm, the form of virtual CT gastroscopy studied was not capable of competing with the imaging quality provided by fiberoptic gastroscopy.
We carried out a cost analysis of a teleradiology system for emergency computerized tomography (CT) examinations. Teleradiology was implemented by connecting two spiral CT scanners in the University Hospital in Innsbruck and the Regional Hospital in Zwettl. It enabled the remote hospital in Zwettl to get fast and competent reports of emergency CT examinations when there was no specialist radiologist available. In 13 months' use for routine night and weekend service, the system proved fast and reliable. During the study period 121 emergency examinations of 116 patients were transmitted from Zwettl to Innsbruck. The fixed costs of teleradiology were for the ISDN connection and amounted to DM230 plus DM696/year rental. The average cost of one emergency CT examination by teleradiology was DM372 (range 308-453). One possible alternative, transporting the films by taxi for reporting elsewhere, was cheaper (estimated cost DM156), but would have been much slower. Another alternative, transporting the patient to the nearest central hospital for scanning, was much more expensive: DM524 by road or DM4667 by helicopter ambulance.
Explore the source record for details and available documents.
PURPOSE: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n = 2), the tracheobronchial system (n = 3), the nasal sinuses (n = 2), the colon (n = 2), and the common carotid artery n = 1). Software developed specifically for virtual endoscopy ("Navigator") was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. RESULTS: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Through use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. CONCLUSIONS: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware.
A review on the theoretical challenges and potential risks of teleradiology is given. Based on the authors two years clinical experience and the current literature unsolved problems are discussed, which are to a smaller extent the technical implementation but much more the still missing regulation of various concomitant circumstances.
Virtual CT-colonoscopy is a post-processing method which allows for reconstruction of inner bowel surface structures from helical CT datasets. The reconstructed images simulate the views which are known from fiberoptic endoscopy. Since colorectal cancer is the second main cause of death in USA and Europe today and since recent screening recommendations are often ignored by the public, a non-invasive or minimal-invasive procedure for colonic evaluation would offer some benefits. Virtual CT-colonoscopy generally involves three essential steps: patient preparation with cleansing of the bowel and administration of an air enema, helical CT-examination by using appropriate scan parameters, and interactive 3D rendering of the volume data-set. Although recent studies have demonstrated that polypoid lesions of about 5 mm size are well detectable and although virtual colonoscopy offers many advantages over fiberoptic endoscopy, some technical and clinical limitations must still be noted. Thus, the current inability of virtual colonoscopy to provide texture and color leads to problems in identifying flat lesions; the presence of retained or adherent fecal matter may result to false positive diagnosis and collapsed segments of bowel may cause problems as they cannot subsequently be evaluated during image reconstruction. Virtual endoscopy is still in its infancy and further technical and clinical developments are necessary. Virtual CT-colonoscopy may then prove to be equal or superior to colonoscopy in sensitivity and specificity for polyp detection and be able to reduce the number of unnecessary colonoscopic procedures.
Eighty-five patients with grade 2 or grade 3 sprains of the acromioclavicular (AC) joint were evaluated clinically and radiographically 32 months after injury. Group I included 34 patients with grade 2 sprains (Tossy II) and group II included 51 patients with grade 3 injuries (Tossy III). In group I, 15 patients were treated surgically (group Ia) and 19 patients were treated conservatively (group Ib), while in group II, 41 patients were treated surgically (group IIa) and 10 patients were treated conservatively (group IIb). At surgery open reduction and transarticular fixation of the AC joint with Kirschner wires was performed. Conservative treatment included the initial use of a sling or a knapsack bandage and early performance of range-of-motion exercises. Shoulder function was assessed according to the score devised by Constant and Murley. In both groups, 97 of 100 possible points (minimum 72, maximum 100) were obtained after conservative and after surgical treatment. Nine of 10 patients (90%) with grade 3 sprains (group IIb) had more pronounced displacement and increased mobility of the lateral end of the clavicle after conservative treatment. After surgery, dislocation and increased horizontal, mobility of the lateral end of the clavicle occurred in 18 (44%) of 41 patients with grade 3 sprains (group IIa P < 0.0001). However, these findings did not correlate with the functional outcome. At follow-up there was a significant increase in degenerative changes seen on radiographs (P < 0.035) in all patients. Again these findings did not correlate with the functional outcome. More degenerative radiological changes were observed in patients who had undergone surgery (P < 0.003). Patients with grade 2 sprains were more frequently restricted in sporting activity after surgery (P < 0.05). Patients with grade 3 sprains who were treated surgically complained of pain more frequently (P < 0.01), and they returned to work later than patients who were treated conservatively after grade 3 sprains. An additional rehabilitation program guided by a physiotherapist seemed to have no impact on the functional outcome. A total of 56 patients were treated by surgery. Among these patients 11 complications occurred, requiring five additional surgical procedures. Among 29 conservatively treated patients, only in 1 patient did subacromially located arthritic changes of the AC joint have to be removed.
PURPOSE: In this article a new method - the Smart-Scan-Technique - for dose reduction during spiral computed tomography is described. This technique allows a dynamical adaptation of the tube current according to the measured local density structure form and absorption values of the object of interest. Its clinical applicability for dose reduction is investigated. In addition, changes in image quality are evaluated. METHODS: Specially designed, water filled plexiglas-phantoms, an Alderson-Rando phantom, and 20 patients were used to simulate possible measures of patients within the thoracic and abdominal region. For those two regions the dose reduction, the modulation transfer function, and the pixel noise were measured. RESULTS: Depending on patient geometry dose reduction up to 20% could be achieved with the Smart-Scan-Technique. This technique also enabled a decrease of the modulation transfer function and an increase of the pixel noise by 8%. CONCLUSION: Relevant dose reductions can be achieved by applying the Smart-Scan-Technique in spiral computed tomography.
UNLABELLED: The teleradiological connection between the University Hospital in Innsbruck, Tyrol, and the Regional Hospital in Zwettl, Lower Austria, is presented as an example of a routine online connection of two helical CT systems. PURPOSE: To establish a practicable and cost-efficient emergency CT service in a remote hospital during night time and on weekends. MATERIAL AND METHODS: Online connection of a GE HiSpeed Advantage-Spiral-CT and a GE Prospeed-Spiral-CT via two Sun SPARC 10 work stations and ISDN. RESULTS: The transmission of 121 CT data sets from 116 patients revealed a sufficiently fast average transmission time of 15 (6-53) minutes and average transmission costs of DM 9.00 per examination. The system was technically reliable, cost-efficient and practicable in clinical routine application. CONCLUSIONS: Teleradiology enables remote hospitals to provide an emergency CT service even if there is no radiological specialist available outside office hours. Thus time-consuming and cost-intensive patient transfers and delay of therapy can be reduced.
A new investigation technique in computed tomography--the Smart Scan process--and the associated reduction in tube current are discussed. In addition, the reduced dosage values resulting from the reduced current values are compared with those of a standard measurement and image characteristics such as picture unit noise are evaluated. By means of three special water phantoms with dimensions corresponding to those of actual patient geometries and a pool of 183 patients, the Smart Scan process was tested by the control algorithm implemented on a spiral computer tomograph. The dosage values with and without the Smart Scan being activated were determined. Dosage reductions of up to 18% can be realized with this new examination technique. In particular, patients with transverse oval head profiles will benefit from this modality.
Spinal cord compression due to extradural and subdural haemorrhage is a neurosurgical emergency. Differences in clinical presentation in relation to localisation of the haematoma, value of MRI as a diagnostic tool, surgical treatment, and prognosis were investigated in a retrospective case series of eight patients with extradural (n = four) and subdural (n = four) haematomas. Results of MRI were compared with operative findings and proved to be of high sensitivity in defining the type of bleeding and delineating craniocaudal extension and ventrodorsal location. Surgical treatment by decompressive laminectomy, haematoma evacuation, and postoperative high dose corticosteroids resulted in resolution of symptoms in five patients and improvement in the clinical situation in two patients. One patient with a chronic subdural haematoma had a second operation because of arachnoidal adhesions. One patient presented with a complete cord transection syndrome due to an acute subdural haematoma and remained paraplegic. It is concluded that prompt, reliable, and non-invasive diagnosis by MRI leads to efficient surgical treatment and a favourable outcome in this rare condition.