Search PubMed⌕ Search

Biomedical subjects

A D Woolfson

Publications and source records attributed to A D Woolfson.

At least 19 recordsLinked to original sources

Mechanical characterization and drug permeation properties of tetracaine-loaded bioadhesive films for percutaneous local anesthesia.

In the development of bioadhesive patch devices for percutaneous local anesthesia, the tensile properties of the films produced after the casting of the gel intermediates is of key importance to the clinical compliance of the product, and its effective delivery of the local anesthetic agent. A range of bioadhesive patches were formulated and their mechanical and in vitro permeation properties determined. Altering formulation significantly altered the mechanical properties of films. The tensile properties of the films could be modified to allow concomitant benefits in the mechanical and drug permeation properties of the films, ensuring that patches not only exerted clinically beneficial effects, but are also mechanically robust. Tetracaine was found to plasticize films and while this effect was weak, it was significant both statistically and potentially also in the effect it has on the clinical use of these devices. Drug release from tetracaine patches demonstrate the same trends as found previously across polydimethylsiloxane films. By altering the formulation of the patch device, the drug release from the device to the skin is readily and accurately controlled, and was not solely a function of the stratum corneum barrier properties but additionally of the formulation.

Adhesives↗

Controlled release of a model antibacterial drug from a novel self-lubricating silicone biomaterial.

There is considerable interest in developing medical devices that provide controlled delivery of biologically active agents, for example, to reduce the incidence of device-related infection. Silicone elastomers are one of the commonest biomaterials used in medical device production. However, they have a relatively high coefficient of friction and the resulting lack of lubricity can cause pain and tissue damage on device insertion and removal. Novel silicone cross-linking agents have recently been reported that produce inherently 'self-lubricating' silicone elastomers with very low coefficients of friction. In this study, the model antibacterial drug metronidazole has been incorporated into these self-lubricating silicone elastomers to produce a novel bioactive biomaterial. The in vitro release characteristics of the bioactive component were evaluated as a function of cross-linker composition and drug loading. Although conventional matrix-type release kinetics were observed for metronidazole from the silicone systems, it was also observed that increasing the concentration of the cross-linking agent responsible for the lubricious character (tetra(oleyloxy)silane) relative to that of the standard non-lubricious cross-linking agent (tetrapropoxysilane) produced an increase in the metronidazole flux rate by up to 65% for a specified drug loading. The results highlight the potential for developing lubricious silicone medical devices with enhanced drug release characteristics.

Anti-Bacterial Agents↗

Design of a silicone reservoir intravaginal ring for the delivery of oxybutynin.

Oxybutynin, a drug of choice in the treatment of urinary incontinence, has low oral bioavailability due to extensive first-pass metabolism. A toxic metabolite, N-desethyloxybutynin, has been linked to adverse reactions to oral oxybutynin. This study, therefore, reports on the design of an oxybutynin intravaginal ring (IVR) of reservoir design, comprising an oxybutynin silicone elastomer core encased in a non-medicated silicone sheath, manufactured by reaction injection moulding at 50 degrees C. An unusually high initial burst release of oxybutynin (42.7 mg in 24 h) was observed in vitro with a full length core (100 mg drug loading), with subsequent non-zero order drug release. Use of fractional segment cores substantially reduced the burst effect, yielding linear cumulative drug release versus time plots from days 2 to 14. Thus, a 1/8 fractional segment core gave a 24 h burst of 11.28 mg oxybutynin and, thereafter, zero order release at the target dose of 5 mg/day over 14 days. Two oxybutynin cores, each 1/16 of full length, gave a greater release than a single 1/8 core, due to core segment end effects resulting in an increased surface area for release. The burst release was investigated by determining drug solubilities in the propan-1-ol product of elastomer condensation cure (390 mg/ml) and in the elastomer itself (13.9-20.21 mg/ml, by direct extraction and indirect thermal methods). These high oxybutynin solubilities were considered the major contributors to the burst effect. It was concluded that use of a fractional segment core would allow development of a suitable oxybutynin reservoir IVR.

Contraceptive Devices, Female↗

Randomized trial of novel tetracaine patch to provide local anaesthesia in neonates undergoing venepuncture.

BACKGROUND: Procedures such as venepuncture or heel prick are painful and may cause considerable stress to newborn infants. Topical local anaesthetics are effective for venepuncture but need to be applied for at least 60 min and the delivered dose will vary. We assessed a novel tetracaine-based self-adhesive patch in providing controlled local anaesthesia before venepuncture. METHODS: A placebo-controlled, double-blind trial was conducted using a tetracaine patch formulated from hydroxypropylcellulose discs (0.283 cm(2)) containing tetracaine (1 mg x cm(-2)) surrounded by a low tack pressure-sensitive adhesive backing layer. Thirty-two newborn infants of gestation 32-42 weeks (median 36 weeks), aged 3-18 days (median 6 days) were randomized to receive a tetracaine-containing patch or a placebo device applied to the dorsum of the hand 30 min before venepuncture to obtain blood samples. Pain was assessed in response to needle insertion using a validated adaptation of the neonatal facial coding score (NFCS) and the presence of crying. RESULTS: Of 15 tetracaine-treated neonates, 14 (93%) presented little or no pain in response to the procedure compared with six of 17 (35%) who had the placebo patch applied (P=0.01). CONCLUSIONS: The tetracaine patch produced effective pain relief during the venepuncture procedure in both term and pre-term infants. There were no adverse effects, either local or systemic.

Administration, Cutaneous↗

Rheological characterization of bioadhesive, antimicrobial, semisolids designed for the treatment of periodontal diseases: transient and dynamic viscoelastic and continuous shear analysis.

This study examined the creep behavior and oscillatory and flow properties of tetracycline-containing, bioadhesive semisolid formulations, designed for localized treatment of periodontal disease. Formulations were prepared containing hydroxyethylcellulose (HEC, 1, 3, or 5% w/w), poly(vinylpyrrolidone) (PVP, 2 or 3% w/w), polycarbophil (PC, 1 or 3% w/w), and tetracycline (5% w/w, as the hydrochloride). In creep analysis, each formulation exhibited several distinct regions that were mathematically modelled using a multi-element Voigt model with a residual spring and dashpot. Increasing the concentrations of each polymeric component decreased the elastic compliance (J(0)) yet increased the residual viscosity. In oscillatory analysis, increased polymer concentrations increased the storage modulus (G'), the loss modulus (G") and the dynamic viscosity (eta'), yet decreased the loss tangent (tan delta). The relationships between G' or G" and frequency were observed to plateau at higher frequencies, which is indicative of polymer chain entanglement and network formation. With the exception of formulations containing 1% HEC, the formulations were elastic (tan delta < 1), with large G' and small J(0) values. All formulations exhibited pseudoplastic flow with thixotropy. Increasing concentrations of each polymeric component increased the zero-shear viscosity (determined using the Cross model) and was further evidence of polymer chain entanglement. Formulations containing 1% w/w HEC possessed excellent flow properties, however, their thixotropic behavior and essentially elastoviscous nature (large J(0) and tan delta) would be disadvantageous for use in the treatment of periodontal disease because of rapid removal from the pocket and relatively uncontrolled drug release. Despite their advantageous viscoelastic properties, the flow properties of formulations containing 5% w/w HEC were inappropriate, rendering administration through a periodontal syringe potentially difficult. Based on their rheological behavior, formulations containing HEC (3% w/w), PVP (2 or 3% w/w), and PC (1 or 3% w/w) would be suitable for clinical application. However, consideration of other physicochemical properties (e.g., bioadhesion, drug release kinetics) must be performed prior to selection of the most suitable formulation for clinical examination. This study has highlighted the successful complimentary application of creep analysis and oscillatory and flow rheometry for the characterization and development of bioadhesive semisolid formulations for the treatment of periodontal disease.

Adhesives↗

The concomitant development of poly(vinyl chloride)-related biofilm and antimicrobial resistance in relation to ventilator-associated pneumonia.

Ventilator-associated pneumonia is a major cause of death in intensive care patients and the endotracheal tube, commonly fabricated from poly(vinyl chloride) (PVC), is acknowledged as a significant factor in this. Bacteria colonise the biomaterial, thereby adopting a sessile mode of growth that progresses to the establishment of an antibiotic-resistant biofilm by the accretion of a protective glycocalyx. This study examined the sequential steps involved in the formation of biofilm on PVC by atomic force microscopy and the concomitant development of resistance to an antibiotic (ceftazidime) and to a non-antibiotic antimicrobial agent (hexetidine). Staphylococcus aureus and Pseudomonas aeruginosa isolated from ET tube biofilm were employed. The surface microrugosity of bacteria growing in sessile mode on PVC decreased significantly (p < 0.05) over the period 4, 24, 48 h and 5 d. The progressive accretion of bacterial glycocalyx was readily visualised in micrographs leading to a smoother surface topography with time. The minimum inhibitory concentrations (MIC) and minimum bactericidal concentrations (MBC) for ceftazidime and hexetidine against planktonic (suspension) S. aureus were lower than for Ps. aeruginosa. Furthermore, sessile populations of S. aureus and Ps. aeruginosa on PVC exhibited greater resistance to both ceftazidime and hexetidine when compared to planktonic bacterial growth. The efficacy of the agents, determined by kill kinetics, against sessile bacteria was dependent on age, with established biofilms (> or = 24 h) significantly more resistant (p < 0.05) than early sessile populations (< or = 4 h). Importantly, for practice, even newly colonised bacteria (1 h) were significantly more resistant to antibiotic than planktonic bacteria. Hexetidine was significantly more active (p < 0.05) than ceftazidime on biofilms of both isolates, irrespective of age, with total kill within 24 h treatment. Hexetidine may offer promise in the resolution of infection associated with PVC endotracheal tubes.

Anti-Bacterial Agents↗

Conditioning film and environmental effects on the adherence of Candida spp. to silicone and poly(vinylchloride) biomaterials.

The reported incidence of colonization of oropharyngeal medical devices with Candida spp. has increased in recent years, although few studies that have systematically examined the adherence of yeast cells to such biomaterials, the primary step in the process of colonization. This study, therefore, examined the effects of oropharyngeal atmospheric conditions (5% v/v carbon dioxide) and the presence of a salivary conditioning film on both the surface properties and adherence of Candida albicans, Candida krusei and Candida tropicalis to PVC and silicone. Furthermore, the effects of the salivary conditioning film on the surface properties of these biomaterials are reported. Growth of the three Candida spp. in an atmosphere containing 5% v/v CO2 significantly increased their cell surface hydrophobicity and reduced the zeta potential of C. albicans and C. krusei yet increased the zeta potential of C. tropicalis (p<0.05). Furthermore, growth in 5% v/v CO2 decreased the adherence of C. tropicalis and C. albicans to both PVC and silicone, however, increased adherence of C. krusei (p<0.05). Pre-treatment of the microorganisms with pooled human saliva significantly decreased their cell surface hydrophobicity and increased their adherence to either biomaterial in comparison to yeast cells that had been pre-treated with PBS (p<0.05). Saliva treatment of the microorganisms had no consistent effect on microbial zeta potential. Interestingly, adherence of the three, saliva-treated Candida spp. to saliva-treated silicone and PVC was significantly lower than whenever the microorganisms and biomaterials had been treated with PBS (p<0.05). Treatment of silicone and PVC with saliva significantly altered the surface properties, notably reducing both the advancing and receding contact angles and, additionally, the microrugosity. These effects may contribute to the decreased adherence of saliva-treated microorganisms to these biomaterials. In conclusion, this study has demonstrated the effects of physiological conditions within the oral cavity on the adherence of selected Candida spp. to biomaterials employed as oropharyngeal medical devices. In particular, this study has ominously shown that these materials act as substrates for yeast colonization, highlighting the need for advancements in biomaterial design. Furthermore, it is important that physiological conditions should be employed whenever biocompatibility of oropharyngeal biomaterials is under investigation.

Journal Article↗

High-performance liquid chromatographic determination of 17beta-estradiol and 17beta-estradiol-3-acetate solubilities and diffusion coefficents in silicone elastromeric intravaginal rings.

A rapid, sensitive reversed-phase high-performance liquid chromatographic method has been developed for the determination of in vitro release of 17beta-estradiol and its ester prodrug, 17beta-estradiol-3-acetate, from silicone intravaginal rings. Partial hydrolysis of the acetate under the aqueous conditions provided by the 1% benzalkonium chloride release medium necessitates its conversion to 17beta-estradiol prior to HPLC analysis. Both steroid peaks have been fully resolved from the benzalkonium chloride peaks by the reported chromatographic method, which employs a C18 bonded reversed-phase column, an acetonitrile-water (50:50, v/v) mobile phase and a UV detection wavelength of 281 nm. The peak area versus 17beta-estradiol concentration was found to be linear over the range of 0.0137-1347 microkg ml(-1). The HPLC method has also been used to determine the silicone solubilities and diffusion coefficients of the two related steroids. The almost 100-fold increase in 17beta-estradiol-3-acetate release from the silicone core-type intravaginal rings compared to 17beta-estradiol is shown to be due to a 60-fold increase in silicone solubility and a one and a half-fold increase in diffusitivity. The results demonstrate that an effective estrogen replacement therapy dose of 17beta-estradiol may be administered from a silicone intravaginal reservoir device containing the labile 17beta-estradiol-3-acetate prodrug.

Administration, Intravaginal↗

Rheological, mechanical and membrane penetration properties of novel dual drug systems for percutaneous delivery.

In this study it has been demonstrated that mixtures of two solid drugs, ibuprofen and methyl nicotinate, with different but complementary pharmacological activities and which exist as a single liquid phase over a wide composition range at skin temperature, can be formulated as o/w emulsions without the use of an additional hydrophobic carrier. These novel dual drug systems provided significantly enhanced in vitro penetration rates through a model lipophilic barrier membrane compared to conventional individual formulations of each active. Thus, for ibuprofen, drug penetration flux enhancements of three- and 10-fold were observed when compared to an aqueous ibuprofen suspension and a commercial alcohol-based ibuprofen formulation, respectively. Methyl nicotinate penetration rates were shown to be similar for aqueous gels and emulsified systems. Mechanisms explaining these observations are proposed. Novel dual drug formulations of ibuprofen and methyl nicotinate, formulated within the liquid range at skin temperature, were investigated by oscillatory rheology and texture profile analysis, demonstrating the effects of drug and viscosity enhancer concentrations, and disperse phase type upon the rheological, mechanical and drug penetration properties of these systems.

Administration, Topical↗

Design, characterisation and preliminary clinical evaluation of a novel mucoadhesive topical formulation containing tetracycline for the treatment of periodontal disease.

This study describes the formulation, characterisation and preliminary clinical evaluation of mucoadhesive, semi-solid formulations containing hydroxyethylcellulose (HEC, 1-5%, w/w), polyvinylpyrrolidine (PVP, 2 or 3%, w/w), polycarbophil (PC, 1 or 3%, w/w) and tetracycline (5%, w/w, as the hydrochloride). Each formulation was characterised in terms of drug release, hardness, compressibility, adhesiveness (using a texture analyser in texture profile analysis mode), syringeability (using a texture analyser in compression mode) and adhesion to a mucin disc (measured as a detachment force using the texture analyser in tensile mode). The release exponent for the formulations ranged from 0.78+/-0.02 to 1. 27+/-0.07, indicating that drug release was non-diffusion controlled. Increasing the concentrations of each polymeric component significantly increased the time required for 10 and 30% release of the original mass of tetracycline, due to both increased viscosity and, additionally, the unique swelling properties of the formulations. Increasing concentrations of each polymeric component also increased the hardness, compressibility, adhesiveness, syringeability and mucoadhesion of the formulations. The effects on product hardness, compressibility and syringeability may be due to increased product viscosity and, hence, increased resistance to compression. Similarly, the effects of these polymers on adhesiveness/mucoadhesion highlight their mucoadhesive nature and, importantly, the effects of polymer state (particularly PC) on these properties. Thus, in formulations where the neutralisation of PC was maximally suppressed, adhesiveness and mucoadhesion were also maximal. Interestingly, statistical interactions were primarily observed between the effects of HEC and PC on drug release, mechanical and mucoadhesive properties. These were explained by the effects of HEC on the physical state of PC, namely swollen or unswollen. In the preliminary clinical evaluation, a formulation was selected that offered an appropriate balance of the above physical properties and contained 3% HEC, 3% PVP and 1% PC, in addition to tetracycline 5% (as the hydrochloride). The clinical efficacy of this (test) formulation was compared to an identical tetracycline-devoid (control) formulation in nine periodontal pockets (>/=5 mm depth). One week following administration of the test formulation, there was a significant improvement in periodontal health as identified by reduced numbers of sub-gingival microbial pathogens. Therefore, it can be concluded that, when used in combination with mechanical plaque removal, the tetracycline-containing semi-solid systems described in this study would augment such therapy by enhancing the removal of pathogens, thus improving periodontal health.

Acrylic Resins↗

Examination of the physical state of chlorhexidine within viscoelastic, bioadhesive semisolids using raman spectroscopy.

This study examined the effects of polymeric components on the physical state of chlorhexidine within bioadhesive, semisolid formulations using Raman spectroscopy. Semisolid formulations were prepared in which chlorhexidine base (CHX, 5%w/w, particle size <63 microm) was dispersed in aqueous (phosphate-buffered saline, pH 6.8) polymer matrices consisting of one or more polymeric components, namely HEC (3%w/w), PVP (3%), and PC (PC, 3%). Raman spectra were recorded using 785-nm excitation and were typically accumulated for 360 s. The Raman spectra were dominated by the presence of CHX. The spectra of CHX in HEC and in HEC/PVP gels were indistinguishable from that for solid CHX as a result of the insolubility of CHX in these formulations. However, in systems containing PC and CHX, there was a shift in the strongest band from 1564 cm(-1) to 1608 cm(-1), which may be accredited to protonation of the basic CHX by the numerous carboxylic acidic groups on PC. Identical shifts in the band positions were observed when this protonation was modeled using ethanoic acid, supporting the view that there was a simple acid base reaction between PC and CHX. However, there were notable differences in the relative intensities of the peaks from these samples, with the spectrum of CHX in the PC matrix displaying properties intermediate between those of CHX dissolved in ethanoic acid and solid CHX diacetate. This may be accredited to the limited solubility of the CHX-PC ion pair. In matrices containing HEC and PC, no peak was observed at 1564 cm(-1), whereas the intensity of the peak at 1608 cm(-1) was increased. Therefore, in these formulations CHX was completely converted to the di-cation as a result of the synergistic effects of PC (which protonated CHX) and HEC (which solubilized the di-cation). In the absence of either HEC or PC, complete protonation was not achieved. It is suggested that this enhancement of solubility of H(2)CHX(2+) may be due to hydrogen bonding, given the hydroxylated nature of HEC. In conclusion, this study has shown the applicability of Raman spectroscopy for both the analysis of opaque, semisolid formulations and, additionally, for the examination of the state of therapeutic agents within such matrices. In particular, using Raman spectroscopy, it was uniquely possible to identify the roles of various polymeric components on both the ionization and solubilization of CHX within aqueous semisolid systems.

Chemistry, Pharmaceutical↗

Novel bioadhesive delivery system for percutaneous local anaesthesia.

We have assessed the efficacy of a novel bioadhesive amethocaine patch device, compared to Ametop gel, in a randomized, double-blinded trial. Patch and gel formulations, including placebos, were applied to the forearms of volunteers (n = 30) for 40 min. Once the formulations were removed from the skin, anaesthesia was assessed by volunteers using a conventional pinprick test. Pain scores were recorded for 4 h after removal of gels and patches. Statistical analysis of the results indicated that both amethocaine gel and patch preparations were superior to placebo (P < 0.05). No significant difference was observed between amethocaine gel and patch formulations (P > 0.05) in either onset time or duration of action for percutaneous local anaesthesia. The results of this study indicate therefore that the novel bioadhesive patch provides clinically comparable anaesthesia to the established gel formulation in a more defined dosage form.

Administration, Cutaneous↗

Determination of the salivary retention of hexetidine in-vivo by high-performance liquid chromatography.

The non-antibiotic antimicrobial agent hexetidine is widely used at a concentration of 0.1% w/v as an oral rinse to reduce the number of viable microorganisms within the oral cavity. However, following use, the available concentration of hexetidine in the oral cavity declines with time, thus compromising the resultant antimicrobial activity. It is, therefore, desirable to determine the persistence of the agent in the oral cavity by quantification of the drug concentration in saliva, thus enabling prediction of its antimicrobial activity in the oral environment. A rapid reverse-phase HPLC method was therefore developed and validated for hexetidine in aqueous solution (Oraldene) and in saliva samples collected from volunteers post-rinsing with 15 mL of hexetidine oral rinse for 30s. The HPLC assay was sufficiently sensitive to accurately detect hexetidine in saliva up to 25 min after in-vivo use of a commercial oral rinse. Furthermore, it was possible to detect hexetidine below the published minimum inhibitory concentrations (MICs) for a selection of microorganisms. From these data a first-order elimination rate constant of hexetidine from the oral cavity was determined post-rinsing in each of six volunteers. The validated HPLC assay method presented is useful for the assay of hexetidine in the oral cavity both at and below MICs. The first-order elimination rate constant shows significant variation between volunteers.

Adult↗

Sustained release of 5-fluorouracil from polymeric nanoparticles.

The use of biodegradable nanoparticles loaded with 5-fluorouracil was investigated as a potential means to sustain the release of this drug. Nanoparticles prepared from four biodegradable polymers were loaded with 5-fluorouracil using three loading concentrations of drug and three different concentrations of added polymer. Washing particles using a centrifugation/re-suspension with ultrasound protocol was found to dislodge the majority of drug, resulting in an over-estimation of incorporation efficiency and low levels of strongly entrapped drug. Increasing the initial 5-fluorouracil concentration before polymer/monomer addition increased the drug loading in both washed and unwashed particles. Increasing the amount of polymer used to make nanoparticles did not increase loadings, but did produce increased amounts of unusable polymer waste. Drug release from nanoparticles was evaluated using a Franz cell diffusion apparatus, which showed an initial burst effect followed by a slower release phase over 24 h. Indeed, nanoparticles prepared from poly(lactide-co-glycolide) released 66% of their 5-fluorouracil payload over this period. It was concluded that 5-fluorouracil-loaded nanoparticles could be readily included into a hydrogel-based delivery system to provide sustained drug release for trans-epithelial drug-delivery applications.

Delayed-Action Preparations↗

Drug delivery by the intravaginal route.

The human vagina represents a potential, accessible space that offers a valuable route for drug delivery through the use of specifically designed carrier systems for both local and systemic applications. Intravaginal drug delivery is particularly appropriate for drugs associated with women's health issues but may also have applications in general drug delivery within the female population. A range of drug delivery platforms suitable for intravaginal administration are discussed in this review, including hydrogels, vaginal tablets, pessaries/suppositories, particulate systems, and intravaginal rings. Drug release mechanisms and absorption pathways are reviewed with respect to a range of therapeutic and prophylactic indications for intravaginal delivery.

Absorption↗

Response surface methodology as a predictive tool for determining the effects of preparation conditions on the physicochemical properties of poly(isobutylcyanoacrylate) nanoparticles.

Preparation conditions of nanoparticles greatly influence their physicochemical characteristics. A factorial design was used to evaluate the influence of these conditions on the particle diameter, zeta potential, polydispersity, percentage recovery, and molecular weight of poly(isobutylcyanoacrylate) nanoparticles. The relationship between these responses and the effects of simultaneously varying three preparation factors (monomer concentration, surfactant concentration, pH of the polymerization medium) were modelled by response-surface methodology. Three levels were chosen for each factor, giving 27 trials. The responses obtained in the experimental design were found to be modelled by either a reduced quadratic or second-order model. Particle diameter was found to be a function of the pH, whereas zeta potential depended on pH and to a lesser extent of the monomer concentration. Polydispersity depended on the pH and an interaction term between pH and the surfactant concentration. The particle recovery was significantly influenced by all three factors, whereas the pH was the primary influence on the molecular weight. Thus, response surface methodology gave detailed information on the predicted physicochemical characteristics found on poly(isobutylcyanoacrylate) nanoparticles prepared using a wide range of experimental conditions.

Bucrylate↗

Design of an intravaginal ring for the controlled delivery of 17 beta-estradiol as its 3-acetate ester.

Suitable ester prodrugs of 17beta-estradiol are identified, thus permitting effective sustained and controlled estrogen replacement therapy (ERT) from an elastomeric, silicone intravaginal ring (IVR). IVR devices of reservoir design were prepared by blending silicone elastomer base with n-propylorthosilicate (cross-linker) and 10% w/w of 17beta-estradiol or an ester prodrug, the mix being activated with 0.5% w/w stannous octoate and cured at 80 degrees C for 2 min. A rate-controlling membrane was similarly prepared, without the active agent. IVR devices were of cross-sectional diameter 9 mm, outer diameter 54 mm, with core cross-sectional diameter of 2 mm and core length varied as required. Sink conditions were evident for the 17beta-estradiol esters in 1.0% aqueous benzalkonium chloride solution. The low release rates into 0.9% w/v saline of the lipophilic valerate and benzoate esters were due to their intrinsically low aqueous solubilities. In vivo, these esters failed to raise plasma estradiol above baseline levels in postmenopausal human volunteers, despite good in vitro release characteristics under sink conditions. The best release rates under sink conditions, in combination with substantial aqueous solubilities as indicated by the release rates into saline, were observed for the acetate and propionate esters. A combination of drug release characteristics, short plasma half-life and a toxicologically acceptable hydrolysis product indicated that 17beta-estradiol-3-acetate was the prodrug of choice for IVR delivery of ERT. In vivo, an IVR device releasing 100 microg/day of estradiol as its 3-acetate ester maintained over 84 days a circulating plasma concentration in the region of 300 pmoll(-1), within the clinically desirable range for ERT.

Administration, Intravaginal↗