Search PubMed⌕ Search

Biomedical subjects

A D Williams

Publications and source records attributed to A D Williams.

At least 19 recordsLinked to original sources

Evaluation of dysfunction following reconstruction of an anorectal anomaly.

To evaluate the utility of anorectal manometry (ARM) and magnetic resonance imaging (MRI) with an endocoil in the assessment of dysfunction in children with repaired anorectal anomalies (ARA), 15 patients aged 1 to 15 years with repaired ARAs and chronic faecal incontinence or constipation were prospectively recruited. They underwent clinical assessment using a modified Wingfield score (MWS). ARM and MRI with an endocoil and conventional external coil were carried out. The results of ARM alone, MRI alone, and a combination of ARM and MRI were correlated with the MWS. Manometric internal anal sphincter (IAS) scores determined from sphincter length and activity correlated with MWS (r = 0.56, P = 0.02); manometric scores of rectal peristaltic activity did not. Overall manometric score (IAS and rectal scores combined) showed a correlation with MWS (r = 0.55, P = 0.02). Endoanal MRI sphincter scores did not correlate with MWS, but the presence of a megarectum on MRI did (r = 0.44, P = 0.05). Overall MRI score did not correlate with MWS. Minor neurosacral anomalies were shown on MRI in 3 children who had poor functional scores. Combined manometric and MRI scores showed a correlation with MWS (r = 0.58, P = 0.01). ARM and MRI are potentially useful in the assessment of dysfunction of children with repaired ARAs. Both modalities require refinement and further assessment in the context of directing management.

Adolescent↗

Catheter tracking for MR fluoroscopy: design of a transmit/receive coil for use with a nasogastric tube.

A coil tuned to 21.3 MHz was incorporated into a nasogastric tube and used as a marker of tube position during magnetic resonance (MR) imaging in a 0.5-T scanner. Catheter tracking was investigated with the coil used in both transmit/receive and in receive-only modes. Data acquired from this coil were overlaid on images obtained using the body coil of the scanner. Visualization of the full length of the catheter with local high signal at the tip was achieved with a temporal resolution of approximately 1 second. J. Magn. Reson. Imaging 2001;13:127-130.

Equipment Design↗

Detection of pelvic lymph node metastases in gynecologic malignancy: a comparison of CT, MR imaging, and positron emission tomography.

OBJECTIVE: Accurate assessment of lymph node status before treatment is critical in the treatment of gynecologic cancers because the 5-year survival and treatment of women is influenced by lymph node involvement. The aims of this study were to investigate the ability of X-ray CT, MR imaging, and (18)F-FDG positron emission tomography (PET) to detect pelvic lymph node metastases by comparing imaging with histopathologic findings after lymph node dissection. MATERIALS AND METHODS: Eighteen patients with gynecologic cancers were studied by all three imaging methods before surgery. The images were initially reviewed with routine diagnostic conditions and then, subsequently, by two observers who were unaware of the clinical and histopathologic findings of the patients. The nodal sites were split into upper (aortic to common iliac bifurcations) and lower (common iliac bifurcations to inguinal ligament) iliac chains. All observers' results were statistically analyzed with specificity, sensitivity, positive and negative predictive values, Fisher's exact test (individual observers) or chi-square test (combined observers), and Cohen's kappa test. RESULTS: Eight of 18 patients had lymph node metastases at histology. Findings of all three modalities agreed in full in only one patient. CT correctly revealed 10 node-negative patients, whereas MR imaging was correct in eight of these patients. (18)F-FDG PET correctly depicted one patient with lymph nodes negative for tumor. CT was the most specific imaging modality (97.0%), with MR imaging and PET rendering values of 90.7% and 77.3%, respectively, but sensitivity of all modalities was low (CT, 48.1%; MR imaging, 53.7%; PET, 24.5%). Observer agreement for each modality was good; kappa values among all observers were 0.88 for CT, 0.85 for MR imaging, and 0.72 for PET. CONCLUSION: CT is the most specific modality for detecting lymph nodes positive for tumor in gynecologic cancers, whereas MR imaging is the most sensitive. The poor results of PET in the pelvis are attributed to urinary (18)F-FDG in the ureters or bladder, which may mask or imitate lymph node metastases.

Adult↗

Psychometric concerns in neuropsychological testing.

This article describes measurement and norming problems with commonly used neuropsychological tests. Test standards regarding differential diagnoses, validity and reliability, the need for manuals, standardized administration, screening, and research versions are discussed. Further development of reliability, validity, sensitivity and specificity is needed for many tests.

Diagnosis, Differential↗

Magnetic resonance imaging of the primary site in stage I cervical carcinoma: A comparison of endovaginal coil with external phased array coil techniques at 0.5T.

OBJECTIVE: To compare endovaginal with pelvic phased array coil magnetic resonance imaging (MRI) in detection of Stage I cervical carcinoma by correlating the findings with histopathology. PATIENTS AND METHODS: Forty consecutive patients with Stage I cervical carcinoma confirmed histologically were studied using an endovaginal coil alone immediately followed by a pelvic phased array coil. T1-W transverse and T2-W FSE sagittal images made with each coil were analyzed independently by two radiologists noting the presence and size of a mass within the cervix and any parametrial extension or involvement of adjacent organs. Tumor volumes were measured using the electronic calliper to compute tumor area on each slice and multiplying by the slice thickness. Thirty patients underwent radical hysterectomy, one a trachylectomy, one simple hysterectomy and four extended cone biopsies. Four patients had radiotherapy to the primary tumor. Following surgery, histopathologic findings were recorded and tumor volumes measured. RESULTS: Tumor volumes ranged from 0-106 cm(3)(median 1.4 cm(3), mean 9 +/- 19.4 cm(3)). Thirty-six patients had correlation of the primary site with the surgical specimen. Agreement between observers was excellent for both endovaginal (k = 0.90) and pelvic phased array (k = 0.96) techniques. Combined sensitivity and specificity for both observers of endovaginal MR imaging for detection of tumor was 96% and 70%, respectively; for pelvic phased array imaging sensitivity was substantially less at 54%. Specificity was higher at 83.7%, probably because small abnormalities were seldom visible. In patients treated surgically, early parametrial involvement in four women on endovaginal MRI was confirmed histologically in two. Pelvic phased array imaging showed early parametrial involvement in four women and was confirmed in one. CONCLUSION: Endovaginal MRI adds substantially to information from pelvic phased array images in the preoperative assessment of patients with early cervical cancer. J. Magn. Reson. Imaging 2000;12:1020-1026.

Adult↗

Chronic myelogenous leukemia primitive hematopoietic progenitors demonstrate increased sensitivity to growth factor-induced proliferation and maturation.

We investigated whether primary chronic myelogenous leukemia (CML) hematopoietic progenitors demonstrated altered proliferation and maturation in response to growth factor (GF) stimulation. The effect of GF stimulation on proliferation and expansion of committed and primitive progenitors (colony forming cells [CFC]) was evaluated. Culture of CML and normal CD34(+) cells with different GF for 7 days resulted in similar expansion of committed progenitors (CFC). In contrast, GF culture conditions that expanded normal primitive progenitors (week-6 long-term culture-initiating cells (LTC-IC)] led to depletion of CML LTC-IC numbers. GF culture also resulted in increased depletion of week-10 extended LTC-IC, which represent an even more primitive progenitor population, from CML compared with normal CD34(+) cells. CML CD34(+) cells enter into cycle more quickly than normal CD34(+) cells and CML CFC expansion was accelerated compared to normal CFC. Evaluation of primitive progenitor proliferation using PKH-26 and single-cell LTC-IC analysis demonstrated that the majority of CML LTC-IC remaining after GF culture originated from divided CD34(+) cells, whereas GF-cultured normal LTC-IC were derived mainly from undivided cells. Depletion of CML primitive progenitor numbers in association with increased proliferation suggests increased sensitivity to GF-induced maturation. These studies indicate that CML primitive progenitors have enhanced sensitivity to GF-induced cell division and maturation. Altered GF responsiveness may contribute to abnormal expansion of malignant myeloid cells in CML. These findings may also be applied toward the development of novel approaches to select benign stem cells in CML.

Antigens, CD34↗

Pre-polarized saline: an in vivo feasibility study of a potential contrast agent.

The potential for using pre-polarized liquids as contrast agents in vivo is investigated and the feasibility of the method demonstrated. In this study we show the enhancement obtained following intravenous delivery of pre-polarized saline into the antecubital vein of a volunteer. This form of contrast agent provides signal gain on time scales commensurate with its T(1) and allows repeated doses to be administered, thus making alternate acquisitions of data with and without enhancement practicable.

Adult↗

High-resolution magnetic resonance imaging of the anal sphincter using a dedicated endoanal receiver coil.

The use of a surface coil in MR imaging improves signal-to-noise ratio of adjacent tissues of interest. We therefore devised an endoanal receiver coil for imaging the anal sphincter. The probe is solid and re-usable: it comprises a saddle geometry receiver with integral tuning, matching and decoupling. It is placed in the anal canal and immobilised externally. Both in vitro and in vivo normal anatomy is identified. The mucosa is high signal intensity, the submucosa low signal intensity, the internal sphincter uniformly high signal intensity and the external sphincter low signal intensity on T1- and T2-weighted images. In females, the transverse perineal muscle bridges the inferior part of the external sphincter anteriorly. In perianal sepsis, collections and the site of the endoanal opening are identified. In early-onset fecal incontinence following obstetric trauma/surgery, focal sphincter defects are demonstrated; in late-onset fecal incontinence external sphincter atrophy is seen. In fecally incontinent patients with scleroderma, forward deviation of the anterior sphincter musculature with descent of rectal air and feces into the anal canal is noted. The extent of sphincter invasion is assessed in low rectal tumours. In children with congenital anorectal anomalies, abnormalities of the muscle components are defined using smaller-diameter coils. Such information is invaluable in the assessment and surgical planning of patients with a variety of anorectal pathologies.

Adult↗

Effect of 3 weeks of detraining on the resting metabolic rate and body composition of trained males.

OBJECTIVE: To examine the hypothesis that detraining decreases the resting metabolic rate (RMR) of long-term exercisers. DESIGN: Eight pairs of subjects were matched for age, mass and training volume. They were then randomly allocated to either a control group (continue normal training) or detraining group (stop normal training but continue activities of daily living). SETTING: Exercise Physiology Laboratory, The Flinders University of South Australia. SUBJECTS: Sixteen male subjects (age 23.1 +/- 4.7 y (s.d.); mass 73.73 +/- 8.9 kg; VO2max 60.2 +/- 6.3 ml. kg-1.min-1; height 180.3 +/- 5.0 cm; body fat 14.6 +/- 5.4%) were selected from a pool of respondents to our advertisements. INTERVENTIONS: Each pair of subjects was measured before and after a 3-week experimental period. RESULTS: Two (groups) x 3 (2-, 3-and 4-compartment body composition models) ANOVAs were conducted on the difference between the pre- and post-treatment scores for percentage body fat, fat-free mass (FFM) and relative RMR (kJ.kg FFM-1.h-1). No significant between-group differences were identified except for the detraining group's small decrease in FFM (0.7 kg, P = 0.05). The main effects for body composition model were all significant; but the overall differences between the multicompartment models and the 2-compartment one were less than their technical errors of measurement. No significant interaction (P = 0.51) resulted from a 2 x 2 ANOVA on the pre- and post-treatment absolute RMR data for the control (315.2 and 311.9 kJ/h) and detraining groups (325.4 and 325.5 kJ/h). CONCLUSIONS: 3-weeks detraining is not associated with a decrease in RMR (kJ/h, kJ.kg FFM-1.h-1) in trained males; hence, our data do not support a potentiation of the RMR via exercise training. The greater sensitivity of the multicompartment models to detect changes in body composition was of marginal value.

Adult↗

Design and use of internal receiver coils for magnetic resonance imaging.

This review describes coils for MRI that are inserted into the body through natural orifices. It covers the design and implementation of small internal receiver coils for use in the pelvis and gastrointestinal tract. Normal anatomy delineated by the high resolution obtained by using these coils and the appearances in a number of disease states for each clinical application are described.

Artifacts↗

Transanal MR imaging after repair of anorectal anomalies in children: appearances in pull-through versus posterior sagittal reconstructions.

OBJECTIVE: Our objective was to use transanal MR imaging to compare the anatomic appearance of the components of the anal sphincter and the pattern of scarring after a pull-through perineoplasty versus a posterior sagittal anorectoplasty. SUBJECTS AND METHODS: Sixteen children ranging in age from 10 months to 15 years (mean, 10 years) were imaged using transanal receiver coils appropriate to the size of the child. Five had low, four intermediate, and seven high anomalies. Seven had undergone a transanal pull-through procedure, and nine had undergone posterior sagittal reconstruction. The integrity of the muscles was assessed on T1-weighted and short inversion time inversion recovery transverse and coronal images using a qualitative MR imaging score. The pattern of scarring was also assessed. RESULTS: In the transanal pull-through group, four of seven patients showed external sphincter deficiency. A circumferential low-signal-intensity band was seen inferior to the sphincter in six patients. All posterior sagittal reconstructions had a long posterior midline scar. Five of nine patients showed external sphincter deficiency, whereas a further two had internal sphincter deficiency. No differences were seen in MR imaging scores for each operative procedure for all grades of severity of anorectal anomaly. However, a comparison between high and intermediate anomalies showed a small improvement in MR imaging score using the transanal pull-through procedure (Mann-Whitney U test = 3, p < .03). Manometric pressures obtained in 13 patients were poor. CONCLUSION: Transanal MR imaging identifies focal defects and patterns of scarring of the anal sphincter complex in infants and children and provides valuable information about individual muscle components.

Anal Canal↗

Platinum coil-mediated implantation of growth factor-secreting endovascular tissue grafts: an in vivo study.

PURPOSE: To demonstrate in vivo that platinum embolic coils can be used to deliver genetically modified, growth factor-secreting fibroblast grafts into the endovascular space with the long-term goal of improving fibrosis within coil-embolized cerebral aneurysms. MATERIALS AND METHODS: Murine fibroblasts that contained multiple inserts of the DNA for human basic fibroblast growth factor were grown in culture onto 10-mm-long segments of Guglielmi detachable coils. Control (n = 4) and fibroblast-bearing (n = 4) coils were implanted into the common carotid artery in nude rats. The arterial segments that contained the coil were harvested after 14 or 35 days. Cellular content and collagen formation in the treated vessels were assessed histologically. RESULTS: At both 14 and 35 days, samples with control coils showed primarily involuting blood elements with minimal fibroblast proliferation or collagen formation. At 14 days, samples with fibroblast-bearing coils showed extensive fibroblast proliferation. At 35 days, samples with fibroblast-bearing coils showed marked interval fibroblast proliferation and collagen formation. CONCLUSION: Platinum coils can be used as a cell delivery device. Direct intravascular implantation of growth factor-secreting fibroblast grafts leads to improved intravascular scar formation, therefore theoretically reducing the potential for aneurysm regrowth or coil compaction.

Animals↗

Fecal incontinence in scleroderma: assessment of the anal sphincter with thin-section endoanal MR imaging.

PURPOSE: To compare the magnetic resonance (MR) imaging appearance of the anal sphincter in patients with fecal incontinence and scleroderma with that in patients with fecal incontinence alone, scleroderma alone, or neither. MATERIALS AND METHODS: The study population comprised 14 patients with fecal incontinence and scleroderma, four with scleroderma alone, 13 with incontinence alone, and six with neither. T1- and T2-weighted spin-echo, magnetization transfer contrast-weighted, and dynamic gadolinium-enhanced images were obtained and analyzed for the integrity, thickness, and length of sphincter components. Magnetization transfer contrast ratios and T2 were calculated to assess fibrosis of the internal sphincter. The percentage enhancement above baseline was calculated at 30-second intervals for the internal and the external sphincter. RESULTS: Eleven patients with incontinence and scleroderma showed descent of rectal air and feces into the anterior anal canal, with forward deviation of the significantly (P < .05) atrophied internal sphincter, which showed a slower gadolinium-enhancement pattern compared with that in other groups. Patients with incontinence alone showed no evidence of internal sphincter deviation or altered vascularity but had a significant reduction (P < .05) in deep external sphincter bulk. CONCLUSION: In patients with fecal incontinence and scleroderma, endoanal MR imaging helps delineate the anterior sphincter deformity and shows the slower gadolinium-enhancement pattern on dynamic studies of the internal sphincter.

Adult↗

Impulse response of a dental implant in bone by numerical analysis.

The osseointegration process of titanium dental implants in bone has been simulated previously using natural frequency and impulse excitation. However, the impulse strength was arbitrarily chosen and may not have yielded the correct frequencies and displacements to be compared with those measured in a clinical situation. In this work the range of impulse excitation strengths applied to a dental implant osseointegrated in bone and the corresponding response have been examined using the finite element method. Both conditions of a dental pin only and a dental pin with attached cantilever integrated in the mandible have been examined. The dynamic analysis indicated that the frequency and displacement responses are indeed sensitive to impulse duration and direction but independent of impulse load. The analysis summarizes the proper impulse excitation values for a correct interpretation of clinically measured frequency response data.

Biomechanical Phenomena↗

Apparent life-threatening events in presumed healthy neonates during the first three days of life.

OBJECTIVE: To study the historical, clinical and pneumographic correlates of apparent life-threatening events (ALTEs) in a term newborn nursery population during the first 3 days of life in a maternity hospital. METHODS: Twenty newborns with ALTEs during the first 3 days of life were studied. Family, antenatal, and intrapartum histories were reviewed. Diagnostic and therapeutic data surrounding the ALTEs were documented. Multichannel recordings performed after the ALTEs occurred were analyzed. Hospital discharge dispositions and postdischarge outcomes were reviewed. RESULTS: Of approximately 15 000 deliveries during a three-year period, 20 infants had ALTEs. Apnea was the most common presenting symptom, and cyanosis usually accompanied the event. Tactile stimulation and oxygen were the most frequent acute treatments, with airway clearance, intermittent positive pressure ventilation, and cardiac massage less common. Forty percent of the events had potentially identifiable causes, including central nervous system abnormality, airway obstruction, or a persistent fetal cardiovascular shunt. Of the initial nultichannel recordings, 11 had desaturation oor less the 85%, 10 had apneic pauses of greater than 15 seconds, and 4 had bradycardia of less than 80 beats per minute. Eighteen infants were discharged and received home monitors; 4 received medication. ALTEs recurred in 4 infants before discharge and in 1 after discharge. No deaths occurred. CONCLUSIONS: (1) ALTEs do occur in the early newborn period in a low-risk term group; (2) causes are unknown in the majority of cases; (3) multichannel recordings may have abnormalities; and (4) the likelihood of recurrent ALTEs is greater during the first week than during the next 2 months.

Age Factors↗

A computer simulation for learning about the physiological response to exercise.

An interactive computer program written for IBM-compatible microcomputers, which simulates the physiological response to graded exercise in healthy individuals, is described. The program presents high-resolution graphic data (heart rate, pulmonary ventilation, oxygen consumption, and blood lactate concentration) in a form comparable to that of a chart recorder display. Data are derived from an empirical model that allows users to select certain parameters of the subject they wish to investigate, including sex, age, height, weight, and level of training. Measurements may be taken directly from the monitor screen by use of the cross-hair cursor facility provided. The program has been positively evaluated in use by undergraduate students and shown to be an effective teaching aid. The potential use of the software in light of these findings is discussed.

Adolescent↗