Search PubMedSearch

Biomedical subjects

A D Pichard

Publications and source records attributed to A D Pichard.

At least 19 recordsLinked to original sources

Coronary artery morphologic features after coronary rotational atherectomy: insights into mechanisms of lumen enlargement and embolization.

The coronary arteries and myocardium from two patients who died after coronary rotational atherectomy were analyzed to gain insights into the mechanisms of lumen enlargement and to document embolization of calcified plaque. Rotational atherectomy resulted in sharp cuts in plaque, producing a relatively smooth luminal surface. When extensive nodular calcific atherosclerosis was present, the luminal surface was focally uneven with exposure of jagged calcified plaque to blood flow. Deep plaque fissures and medial dissections were also seen. These fissures may have been created by the rotoblator or by adjunctive balloon angioplasty. Multiple calcific atheroemboli were present after rotoblator use in plaques containing extensive nodular calcification; in moderately calcified plaque only one small atheroembolus was found. Thus embolization of calcified plaque can occur after rotational atherectomy and may correlate with the severity of plaque calcification. Rotational atherectomy produces a focally smooth, sharp-edged, luminal surface, a lumen enlargement mechanism different from balloon angioplasty.

Aged

Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations.

OBJECTIVES: This study evaluated the magnitude, patterns and clinical correlates of atherosclerosis in angiographically "normal" reference segments in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND: Pathologic studies indicate that the extent of coronary atherosclerosis is underestimated by visual analysis of angiographically normal coronary artery segments. Intravascular ultrasound allows detailed, high quality cross-sectional imaging of the coronary arteries in vivo. METHODS: Intravascular ultrasound was used to study angiographically normal coronary artery reference segments in 884 patients evaluated for transcatheter therapy for symptomatic native coronary artery disease. The reference segment was the most visually normal intravascular ultrasound cross section within 10 mm proximal to the target lesion but distal to any major side branch. Results are presented as mean value +/- 1 SD. RESULTS: Only 60 (6.8%) of 884 angiographically normal reference segments were normal by intravascular ultrasound. Reference segment percent cross-sectional narrowing measured 51 +/- 13% and correlated poorly with the target lesion percent cross-sectional narrowing (r = 0.166, p < 0.0001). Reference segments contained less calcific and dense fibrotic plaque and proportionately more soft plaque elements. Independent predictors of reference segment percent cross-sectional narrowing were male gender, patient age, diabetes mellitus, hypercholesterolemia and presence of multivessel disease. Independent predictors of reference segment calcification were patient age and serum creatinine levels. Reference segment percent cross-sectional narrowing in 723 patients undergoing transcatheter therapy was similar to that in patients studied for diagnostic purposes; however, reference segment arc of calcium was greater in treated patients (43 +/- 81 vs. 25 +/- 57, p = 0.015). Reference segment disease was not an independent predictor of subsequent angiographic restenosis or clinical events within 12 months of follow-up. CONCLUSIONS: Atherosclerosis is ubiquitous in angiographically normal coronary artery reference segments. Reference segment disease parallels the severity of target lesion disease and is associated with many of the conventional risk factors for coronary artery disease. Because of its sensitivity in detecting atherosclerosis in angiographically normal reference segments, intravascular ultrasound should enhance the study of risk factors for atherosclerosis and the results of therapies to control disease progression.

Age Factors

Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.

OBJECTIVES: The purpose of this study was to use volumetric intravascular ultrasound analysis of Palmaz-Schatz stents to assess the in-stent restenotic process. BACKGROUND: By reducing lesion elastic recoil and chronic arterial remodeling, stents improve the long-term results of coronary angioplasty. However, stents are prone to the development of neointimal hyperplasia. Angiographic studies of stent restenosis have suggested that these hyperplastic responses are the cause of in-stent restenosis; however, it is difficult to visualize the radiolucent Palmaz-Schatz stent by angiography. Intravascular ultrasound provides detailed cross-sectional imaging of the coronary arteries, especially the intense metallic reflection of endovascular stents. METHODS: Forty-four patients with 60 Palmaz-Schatz stents underwent intravascular ultrasound imaging at follow-up ([mean +/- SD] 8.8 +/- 7.2 months after implantation). Thirty-four stents were placed in saphenous vein grafts and 26 in native coronary arteries; 30 were placed in restenotic lesions. Intravascular ultrasound with automatic transducer pullback at 0.5 mm/s allowed measurement of stent, lumen and intimal hyperplasia cross-sectional areas at 1-mm axial increments within the stents. Using Simpson's rule, stent, lumen and intimal hyperplasia volumes were calculated. Patterns of in-stent restenosis were then identified. RESULTS: Restenotic stents had smaller stent volumes (120 +/- 41 vs. 147 +/- 43 mm3, p = 0.016) and lumen volumes (62 +/- 28 vs. 118 +/- 42 mm3, p < 0.0001) but larger intimal hyperplasia volumes (58 +/- 36 vs. 29 +/- 18 mm3, p < 0.001) than nonrestenotic stents. A focal restenosis pattern was more common (20 [77%] of 26) than a diffuse restenosis pattern (6 [23%] of 26). Stents with focal restenosis and stents with diffuse restenosis had equally small stent volumes (120 +/- 44 vs. 120 +/- 31 mm3, respectively, p = NS); however, stents with diffuse restenosis had larger intimal hyperplasia volumes (84 +/- 30 vs. 50 +/- 34 mm3, p < 0.05). Focal restenosis was most commonly located at the central articulation (45%); the location of focal restenosis was related to the focal accumulation of neointimal tissue. CONCLUSIONS: Stent volume and magnitude and distribution of intimal hyperplasia are important in the development of in-stent restenosis. Stent volume was smaller and intimal hyperplasia volume greater in restenotic stents. Stent restenosis is more commonly focal in nature and located at the central articulation.

Aged

A modified directional atherectomy catheter for resection of calcified atherosclerotic plaques.

BACKGROUND: The purpose of this study was to determine the feasibility of resecting calcified atherosclerotic plaques in human cadaveric vessels by using a modified directional coronary atherectomy catheter and to correlate these results with bench tests using an in-vitro sea coral model. METHODS: The conventional directional coronary atherectomy catheter was modified by changing the cutter blade to a tungsten carbide material and by increasing the torsional strength of the drive cable. The performance of the modified directional coronary atherectomy (DCA) catheter was compared with the conventional catheter using a sea coral model to simulate calcified material. Then, 10 human ex-vivo arteries (eight with calcification) were treated with both conventional and modified catheters, and the results studied with intravascular ultrasound and confirmed by histologic examination. RESULTS: Using the modified directional coronary atherectomy catheter it was possible to perform effective and consistent longitudinal cutting, and to resect a significantly larger amount of coral (1.0 +/- 0.1 mm2 versus 0.2 +/- 0.1 mm2 with conventional cutter, P < 0.0001). In heavily calcified ex-vivo arteries, the modified catheter was more effective in removing calcified plaques (13 +/- 11 mg versus 3.7 +/- 1.4 mg with conventional cutter, P = 0.07). Intravascular ultrasound confirmed the effective atherectomy (residual area stenosis 28 +/- 16% versus 47 +/- 10% with the conventional device, P < 0.05), and histologic examination showed calcified nodules in the atherectomy samples obtained with the modified cutter (area of calcium 1.43 +/- 0.89 mm2 versus 0.93 +/- 0.83 mm2 with the conventional cutter). CONCLUSIONS: The modified directional coronary atherectomy catheter effectively removed both non-calcified and calcified plaques in the ex-vivo human cadaveric arteries, thus demonstrating the feasibility of directional coronary atherectomy of calcified plaques. This modified device shows promise for treating calcified coronary lesions, especially in larger vessels.

Animals

Results of coronary angioplasty using the transluminal extraction catheter.

To assess the procedural results after coronary angioplasty using the transluminal extraction catheter (TEC) in patients with complex lesion anatomy, experience with 51 patients undergoing this procedure was reviewed. One or more adverse lesion morphologic features were present in 45 patients (88%) and > or = 2 adverse features were present in 38 (74%). Procedural success (< 50% final diameter stenosis and the absence of major complications) was obtained in 42 patients (82%); major complications occurred in 7 patients (death, 3; Q-wave myocardial infarction, 4; emergency bypass operation, 2). Distal embolization was noted in 5 patients with thrombus-containing saphenous vein graft stenoses. Only lesion thrombus correlated with an unsuccessful outcome. After TEC use, diameter stenosis was reduced from 76 +/- 13 to 50 +/- 22% (p < 0.001). Adjunct balloon angioplasty was used in 44 procedures (86%), further reducing the diameter stenosis to 32 +/- 22% (p < 0.001 compared with post-TEC). High-frequency intracoronary ultrasound was performed in 11 patients after TEC use. Plaque fissuring was present in all lesions and intraluminal dissection was noted in 4 (36%). Residual plaque after TEC use was found in virtually all lesions. During the 5.2 +/- 2.8-month follow-up period, 17 patients (40%) developed recurrent symptoms. Coronary bypass surgery was performed in 4 patients and repeat coronary angioplasty was required in 3. In addition, 3 patients died from cardiac causes. It is concluded that coronary angioplasty using the TEC may be a useful alternative to balloon angioplasty in patients with complex coronary anatomy, although distal embolization may still occur in thrombus-containing saphenous vein graft lesions.

Angioplasty, Balloon, Coronary

Target lesion calcification in coronary artery disease: an intravascular ultrasound study.

OBJECTIVES: The purpose of this study was to evaluate the frequency, amount and distribution of target lesion calcification in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND: Coronary artery target lesion calcification may be an important determinant of response to transcatheter therapy: balloon angioplasty causes dissections in calcified lesions, directional atherectomy cuts calcium poorly, rotational atherectomy causes preferential ablation of calcium and laser irradiation effect may vary. Intravascular ultrasound imaging is a highly sensitive technique for detection of plaque calcification in vivo. METHODS: We performed intravascular ultrasound imaging before or after, or both, various transcatheter therapies in 110 patients. These 84 men and 26 women had a mean age of 60 years and a duration of angina of 22 +/- 34 months. Forty-nine patients had one-vessel, 29 had two-vessel, 25 had three-vessel and 7 had left main coronary disease. Vessels treated and imaged were the left main (n = 7), left anterior descending (n = 47), left circumflex (n = 18) and right (n = 38) coronary arteries. RESULTS: Eighty-four patients (76%) had target lesion calcification; 29 patients had one-quadrant, 25 had two-quadrant, 17 had three-quadrant and 13 had four-quadrant calcification. The calcification was superficial in 42 patients, deep in 13 and both superficial and deep in 31. The axial length of calcium could be measured in 29 patients; it was < or = 5 mm in 11 and > or = 6 mm in 18. Fluoroscopy detected calcification in 50 patients (48%, p < 0.001 vs. detection by ultrasound); this proportion increased to 74% in patients with calcification of two or more quadrants and to 86% in patients with calcification > or = 6 mm in length of two or more quadrants. Calcification was more common in patients who smoked and tended to be more common in patients with multivessel disease or previous coronary artery bypass graft surgery. CONCLUSIONS: We conclude that target lesion calcification occurs in 75% of patients with symptomatic coronary artery disease requiring angioplasty. Target lesion calcification is best detected, localized and quantified by intravascular ultrasound. These observations may be important in selecting devices for transcatheter therapy.

Adult

Prolonged intravenous urokinase infusion: an alternative pharmacologic approach in the treatment of thrombus-containing saphenous vein graft stenoses.

A subtotally occlusive saphenous vein graft stenosis resolved after rapid intracoronary and prolonged intravenous urokinase infusion. Additional therapy was unnecessary, avoiding the attendant risks of saphenous vein graft angioplasty. Combined intracoronary and intravenous urokinase infusion should be considered prior to coronary angioplasty of saphenous vein graft stenoses, particularly when diffuse degeneration is present or the risk of underlying thrombus is high.

Angioplasty, Balloon, Coronary

Failure or success of complex catheter-based interventional procedures assessed by intravascular ultrasound.

Intravascular ultrasound provides high resolution cross-sectional images of vessel walls and may help to characterize atherosclerotic plaque morphology subtypes. This new imaging modality may have an important role in assessing the results of standard and investigational interventional therapeutic procedures. Four case histories of patients with coronary artery disease treated with different catheter-based therapies are presented. In each case, intravascular ultrasound added diagnostic information unobtainable from standard radiographic imaging techniques. These cases, involving PTCA (balloon dilatation), directional coronary atherectomy, high-speed rotational ablation, and balloon-expandable stent implantation, each represent an interesting example of procedure success or failure that could not be fully discerned without the use of intravascular ultrasound. Specifically, the distribution of intramural dissection, the presence and magnitude of intracoronary calcification, and morphologic patterns of intimal hyperplasia leading to restenosis, were accurately identified by ultrasound images. Thus intracoronary ultrasound imaging significantly enhances the understanding of failure modes, success, and complications after therapeutic interventions in patients with complex coronary disease.

Aged

Factors influencing immediate results, complications, and short-term follow-up status after Inoue balloon mitral valvotomy: a North American multicenter study.

Clinical trials with the Inoue mitral valvotomy balloon have recently begun in the United States. We assessed the effects of 17 demographic, echocardiographic, procedural, and hemodynamic variables on the immediate results, complications, and short-term follow-up of 200 patients in 15 centers undergoing valvotomy with this device. The study population had a mean age +/- SD of 53 +/- 15 years, and the total echocardiographic score was 7.2 +/- 2.4. Valvotomy was technically successful in 96.5% of procedures and increased the mean mitral valve area from 1.0 +/- 0.3 to 1.8 +/- 0.7 cm2 (p less than 0.001); 72% had an increase in valve area greater than or equal to 50%, and 67% had a final area greater than or equal to 1.5 cm2. Major procedural complications included cardiac tamponade during transseptal puncture (1.0%), systemic embolism (1.5%), and severe mitral regurgitation (2.4%); there were no procedural deaths and one hospital death. Multivariate analysis identified the absence of prior surgical commissurotomy and younger age as significant predictors of the gain in mitral valve area, but the correlation coefficients were low. Although the absence of subvalvular disease on echocardiograms was a predictor of a final valve area greater than or equal to 1.5 cm2, the total echocardiographic score did not correlate well with the immediate outcome (r = 0.01, p = NS). No variable was identified as predictive of restenosis, which occurred according to echocardiographic criteria in 14 of 66 (21%) patients evaluated 6 months after valvotomy. Good hemodynamic results with valvotomy were achieved in the majority of patients with low complication rates by many investigators with the use of the Inoue balloon device.(ABSTRACT TRUNCATED AT 250 WORDS)

Balloon Occlusion

Atherosclerotic saphenous vein grafts treated with different interventional procedures assessed by intravascular ultrasound.

Intravascular ultrasound imaging of saphenous vein grafts may enhance the angiographic interpretation of results following transcatheter interventions. We used intravascular ultrasound to study 18 patients with stenotic vein grafts following balloon angioplasty, atherectomy, or stent placement. In real-time imaging the three-layer appearance was rarely seen, calcification was infrequent (11% of patients), and atheroma were usually mildly echogenic ("soft"). Despite excellent angiographic results (reduction in percent diameter stenosis from 90 +/- 8% to 17 +/- 8%) and concordant improvement in lumen area by ultrasound regardless of the intervention, there was usually significant retained atheroma at the treatment site. Following balloon angioplasty, ultrasound showed multiple superficial fissures and fractures without discrete dissections. Atherectomy caused a smooth lumen surface without deep dissections or resections, but significant retained atheroma was observed with each one of the atherectomy procedures. Endovascular stents were concentric in the vein with reflective struts above compressed atheroma and an outer echogenic adventitia. Stent expansion was asymmetric axially and longitudinally and evidence of stent recoil was present. Thus intravascular ultrasound may be an important adjunct to angiography in characterizing postintervention results in saphenous vein grafts.

Aged

Arterial responses to balloon coronary angioplasty: an intravascular ultrasound study.

OBJECTIVES: The purpose of this study was to examine the coronary artery response to percutaneous transluminal coronary angioplasty by using intravascular ultrasound. BACKGROUND: The immediate effects of coronary angioplasty on arterial wall geometry and surface appearance are understood poorly. Most of the available data are derived from small necropsy series, inferred from animal models or extrapolated from in vitro studies. High frequency intravascular ultrasound provides transmural images of coronary arteries in vivo. METHODS: We used intravascular ultrasound to study 29 patients before or after, or both, successful coronary angioplasty. RESULTS: The angiographic diameter narrowing was 72 +/- 13% before and improved to 19 +/- 11% after angioplasty. Calcium was visualized in 7 (24%) of the 29 angioplasty sites by fluoroscopy versus 15 (52%) of sites by intravascular ultrasound (p = 0.022). Arterial dissection after angioplasty was observed in 8 (27%) of cases by contrast angiography versus 24 (83%) by intravascular ultrasound (p less than 0.001). Intravascular ultrasound detected extensive dissection at the angioplasty site in 11 (73%) of the 15 calcified plaques and in only 3 (21%) of the 14 noncalcified plaques (p = 0.024). Arterial expansion (defined as the area within the external elastic membrane at the angioplasty site greater than that of the proximal reference segment) occurred in 29% of calcified plaques compared with 86% of noncalcified plaques (p = 0.007). CONCLUSIONS: Intravascular ultrasound is more sensitive than angiography for identifying arterial calcium and dissection at the site of angioplasty. At the site of angioplasty, arterial dissection occurred more frequently in calcified plaques whereas arterial expansion occurred more frequently in noncalcified plaques. Successful angioplasty causes a continuum of arterial responses that vary importantly with plaque composition.

Angioplasty, Balloon, Coronary