Search PubMed⌕ Search

Biomedical subjects

A D Nunn

Publications and source records attributed to A D Nunn.

At least 37 records · Page 2Linked to original sources

Relationship between in vitro transendothelial permeability and in vivo single-pass brain extraction.

UNLABELLED: In vitro transendothelial permeability was compared to in vivo rat single-pass cerebral extractions to evaluate which method would best estimate the blood-brain barrier (BBB) permeability of several SPECT imaging agents. METHOD: Six 99mTc complexes and seven non-Tc complexes were tested in vitro using monolayers of primary bovine brain microvessel endothelial cells and in vivo using the rat single-pass cerebral extraction model. In vitro transendothelial permeability indices (PI) were determined by measuring the average percent of radioactivity traversing the monolayers as a function of time. In vivo single-pass cerebral extractions were determined using an indicator fractionation method. RESULTS: A positive correlation between extraction and PI was found for the non-Tc complexes (r2 = 0.96). The CBF imaging agents 99mTc-ECD and 99mTc-PnAO have high values for E and PI, demonstrating that these agents penetrate the BBB and have a high membrane permeability, while the heart imaging agent 99mTc-sestamibi had low values for both E and PI. The low PI and E values for 99mTc-sestamibi are consistent with a low brain uptake for this agent, except in cases of disruption of the BBB. In contrast to 99mTc-ECD, 99mTc-PnAO and 99mTc-sestamibi, which had concordant values for E and PI, two highly lipophilic boronic acid adducts of technetium dioxime (BATOs), 99mTc-teboroxime and 99mTcCl(DMG)3(2)MP, had low negative values for PI, but high values for E. In addition, after 3 hr of incubation, the monolayer-to-medium concentration ratio of the BATOs was 642:1 and 744:1, respectively. This compares with values of 89:1 (99mTc-PnAO), 25:1 (99mTc-ECD) and 34:1 (99mTc-sestamibi). CONCLUSION: These data suggest that the high in vivo single-pass extraction of the BATOs may be explained by a hydrophobic interaction with the luminal surface of the capillary endothelial cell plasma membrane. We conclude that a high single-pass extraction cannot necessarily be used to infer high BBB or membrane permeability.

Aluminum Oxide↗

Technetium-94m-teboroxime: synthesis, dosimetry and initial PET imaging studies.

Technetium-94m (T1/2 = 53 min) allows the in vivo study of technetium radiopharmaceuticals with positron emission tomography (PET). PET provides a quantitative assay of radioactivity with excellent temporal and spatial resolution, revealing biodistributions that were previously available only through in vitro assay methods. Technetium-94m, produced by the proton irradiation of natural molybdenum on an 11 MeV cyclotron, was extracted with an electrochemical etching technique. Technetium-94m-pertechnetate was prepared to make the myocardial perfusion agent teboroxime in an identical manner as 99mTcO4-. The increased absorbed radiation dose requires a sevenfold reduction in administered activity compared to 99mTc-teboroxime. Eleven clinical PET studies were performed and visually compared to 13N-ammonia. The clearance half-time for 94mTc-teboroxime was approximately 8 min, with a peak myocardial extraction of approximately 3% of the injected dose into a 400-g heart. These results confirm the potential of 94mTc PET for quantitatively studying the pharmacokinetics of new, and old, technetium agents in man.

Adult↗

The single-pass cerebral extraction and capillary permeability-surface area product of several putative cerebral blood flow imaging agents.

We have determined cerebral blood flow (CBF) and the single-pass cerebral extraction (E) of several putative agents for external imaging of CBF. Simultaneous measurements of blood flow and extraction were performed in 106 rats. For all agents, comparison of linear and exponential regressions of E on CBF indicates that this relationship can be described as linear over the range of flows studied. Analysis of covariance indicates that the extraction of 123I-IMP, 67Cu-PTSM and 99mTc-HMPAO is higher than that of 99mTc-Cl(DMG)3(2MP) and 99mTc-ECD, particularly at flows above the normal range. Accordingly, for 123I-IMP, 67Cu-PTSM and 99mTc-HMPAO, the slope of the linear regression equation for the relationship between brain capillary permeability surface area product (PS) and CBF is higher than that for 99mTc-Cl(DMG)(3)2MP and 99mTc-ECD. PS varies as a linear function of CBF over the range of flows studied. At a CBF level that corresponds to normal regional CBF for human cortex, 0.5 ml/g/min, all the agents have a single-pass extraction of approximately 70% or greater. While all the agents detected changes in CBF in the normal to ischemic range, at higher flows 123I-IMP, 67Cu-PTSM and 99mTc-HMPAO showed substantially greater fidelity to true CBF than 99mTc-Cl(DMG)(3)2MP and 99mTc-ECD.

Animals↗

Direct analysis of whole blood by internal surface reversed-phase chromatography: an examination of the binding and metabolism of technetium dioxime complexes.

We have developed a method using internal surface reversed-phase (ISRP) packing for rapid on-line separation of small hydrophobic compounds from cellular whole blood components. This is achieved by the use of 75-microns ISRP chromatographic material packed into a small high-performance liquid chromatographic (HPLC) column, in conjunction with column switching. We have applied this analytical method to study the in vitro metabolism of 99mTc-BATO (boronic acid adducts of technetium dioxime) cerebral and myocardial perfusion tracers in whole blood. The results from the ISRP procedure were compared with a conventional centrifugation method of analysis. This novel HPLC methods provides a rapid, convenient and reliable method for the analysis of radioactive and non-radioactive lipophilic components in whole blood.

Animals↗

Myocardial extraction of teboroxime: effects of teboroxime interaction with blood.

The isolated perfused rat heart preparation was used to determine whether the interaction of blood with either 99mTc-teboroxime, 99mTc-sestamibi or 201TI affects the extraction of these myocardial perfusion agents. Hearts were retrogradely perfused at 72 cm H2O with Krebs-Henseleit buffer equilibrated with O2:CO2 (95:5). The hearts were paced at 5 Hz. Single-pass extraction of 99mTc-teboroxime (96% +/- 1%) was greater than that of 99mTc-sestamibi (15% +/- 1%) or 201TI (30% +/- 5%). Extraction of the hydroxide form of 99mTc-teboroxime was only 43% +/- 4%. When arterial blood obtained from rats administered 99mTc-teboroxime was injected into the perfused heart, extraction of 99mTc-teboroxime decreased progressively as its time in circulation was lengthened. Similar experiments using either 99mTc-sestamibi or 201TI showed that extraction of these agents was neither affected by the presence of blood nor residence in circulation. For 99mTc-teboroxime, extraction was 99.5% +/- 0.5%, 57% +/- 13%, 20% +/- 2% at 1, 5, and 60 min postinjection, respectively. In separate experiments, HPLC analysis of blood at 5, 15 and 60 min postinjection indicated that only 34% +/- 4%, 13% +/- 2%, and 2% +/- 1%, respectively, of the total 99mTc-teboroxime was free and was associated with extraction values of 44% +/- 7%, 28% +/- 5%, and 19% +/- 3%, respectively. The percentage of this free radioactivity that converted from the chloro to the hydroxide form was 9% +/- 2%, 6% +/- 2%, and 2% +/- 1%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Measurement of myocardial blood flow using a co-injection technique for technetium-99m-teboroxime, technetium-96-sestamibi and thallium-201.

We have compared apparent myocardial blood flow (MBFapparent) indicated by 99mTc-teboroxime, 96Tc-sestamibi and 201TI to true MBF indicated by radiolabeled microscopheres using a technique for the co-injection of four radionuclides in the same animal. Studies were performed using rats in a single-pass model to obtain global MBF and using dogs in a multiple-pass model to determine regional MBF. To provide a wide range of MBF, adenosine was administered intravenously and the left anterior descending coronary artery was then ligated in the dogs, or hypercapnia was induced by decreasing respiratory frequency in the rats. The microsphere formula for determining MBF was applied to all agents. When MBFapparent was plotted as a function of true MBF, the ability of each agent to measure changes in true MBF was demonstrated by the proximity of the plotted function to the line of identity. For both the single and multiple-pass studies, statistical analysis of the nonlinear relationship between MBFapparent and true MBF showed that 201TI and 99mTc-teboroxime approximate true MBF better than 96Tc-sestamibi (p less than 0.001) under the conditions used in the present studies. In the single-pass studies, 99mTc-teboroxime approximated true MBF better than 201Tl (p less than 0.05), but in the multiple-pass experiments, 201Tl approximated true MBF better than 99mTc-teboroxime in only one dog (p less than 0.01) with no difference in the other two. Determination of the permeability-surface area product, PS, for each agent shows that the higher fidelity to true MBF obtained with 201Tl and 99mTc-teboroxime is related to substantially greater PS values for these agents relative to 96Tc-sestamibi.

Animals↗

Absorbed radiation dose to humans from technetium-99m-teboroxime.

Tissue distribution data obtained in nine normal volunteers were used to estimate the radiation dose to humans after intravenous administration of 99mTc-teboroxime (Cardiotec). Organ uptake as percent of injected dose was measured using quantitative SPECT. Non-linear regression analysis was performed on the organ time-activity data using SYSTAT software. Cumulative activities in these organs were determined by calculating the area under the respective curves after accounting for the physical decay of the radionuclide. The absorbed dose to individual organs was estimated using the MIRDOSE 2 program. The gallbladder and the upper large intestine (ULI) are the target organs and will receive respectively 26.5 and 33.2 muGy/MBq (98 and 123 mrad/mCi) 99mTc-teboroxime under the assumption that the gallbladder empties every 6 hr. The dose to the gallbladder decreases at shorter emptying intervals; with intervals of 3, 4, and 5 hr, the respective doses to the gallbladder are 18.2, 21.0 and 23.7 muGy/MBq (67.4, 77.8, and 87.9 mrad/mCi) 99mTc-teboroxime. However, the dose to ULI remains almost constant at 123 mrad/mCi and will be the limiting factor.

Gallbladder↗

Chloro----hydroxy substitution on technetium BATO [TcCl(dioxime)3 BR] complexes.

The neutral, seven coordinate complexes of technetium known as the BATO (Boronic acid Adducts of Technetium diOximes) complexes have shown their utility as myocardial and cerebral perfusion agents. The axial chloride ligand of the BATO complexes [99mTcCl(dioxime)3 BR] is labile to substitution by a competitive anion; under physiological conditions, the axial chloride ligand can be replaced by a hydroxy group. The chloro and hydroxy analogs have different biodistributions and single-pass cerebral extraction efficiencies. The influence of structure on the rate of the in vitro chloro/hydroxy exchange process has been studied. The mechanism of axial ligand exchange was found to be SN1-CB, which proceeds by way of a transient, neutral six coordinate complex. Evidence is presented which indicates that chloro/hydroxy exchange is not the mechanism by which BATO complexes are retained in the brain.

Animals↗

Radiopharmaceuticals for imaging myocardial perfusion.

A replacement for 201Tl used in myocardial perfusion imaging with a 99mTc-labeled complex is a long-sought goal. Now, at least three varieties of 99mTc-complexes are being made available for clinical studies. This review summarizes the development of these agents and presents basic research data accumulated in this area. Also, relevant clinical radiopharmaceutical protocols and relative merits of competing 99mTc-agents are discussed.

Animals↗

A neutral lipophilic technetium-99m complex for regional cerebral blood flow imaging.

Technetium-99m-DMG-2MP (Chloro[bis[2,3-butanedionedioxime(1-)-0][2,3- butanedionedioximato (2-)-N,N',N'',N''',N'''',N'''''] (2-methylpropyl borato (2-))technetium]), also known as SQ 32097 is a member of a family of neutral lipophilic compounds generally known as boronic acid adducts of technetium dioxime complexes (BATOs). After i.v. administration, the concentration of [99mTc]DMG-2MP in various regions of the brain appears to be proportional to blood flow. In rats, 1.1% ID was in the brain at 5 min postinjection when the blood contained less than 3% ID. Over 24 hr excretion was 59% in the feces and 23% in the urine. The activity in monkey brain at 5 min was 2.8% ID and it cleared with a t1/2 of 86 min. Autoradiographs of monkey brain sections showed excellent regional detail with a gray/white ratio of 3.6 at 10 min. The distribution of [99mTc]DMG-2MP in the monkey brain corresponds to the known cytoarchitectural pattern of cerebral glucose metabolism. The properties of [99mTc]DMG-2MP make it a potentially useful agent for cerebral perfusion imaging in man.

Animals↗

A neutral technetium-99m complex for myocardial imaging.

Technetium-99m-CDO-MeB [Bis[1,2-cyclohexanedione-dioximato(1-)- O]-[1,2-cyclohexanedione dioximato(2-)-O]methyl-borato(2-)- N,N',N'',N''',N'''',N''''')-chlorotechnetium) belongs to a family of compounds generally known as boronic acid adducts of technetium dioxime complexes (BATOs). It has an intrinsic affinity for the myocardium, with negligible lung activity and rapid blood clearance. The uptake of 3.44% ID in rat heart at 1 min postinjection for [99mTc]CDO-MeB versus 3.03% for 201TI indicates high extraction of [99mTc]CDO-MeB by the myocardium. In dogs an ischemic defect is clearly seen in SPECT images obtained 10 min after injection of [99mTc]CDO-MeB. Tissue distribution data in rats show that [99mTc]CDO-MeB is excreted primarily in the feces and to a lesser extent in the urine. Approximately 80% of the activity is excreted within 24 hr after injection.

Animals↗

Structure-distribution relationships of radiopharmaceuticals. Correlation between the reversed-phase capacity factors for Tc-99m phenylcarbamoylmethyliminodiacetic acids and their renal elimination.

Capacity factors (k') have been obtained for twenty-eight different phenyl substituted phenylcarbamoylmethyliminodiacetic acids (HIDAs) using reversed-phase high-performance liquid chromatography (HPLC). They have been shown to be a useful measure of the lipophilicity of the ligands and their technetium-99m complexes. When k' for the ligands or log Poct for the Tc-99m complexes was plotted against theoretical lipophilicity, three groups of HIDAs were observed. The membership of each group is determined by the degree of ortho substitution. The effect of lipophilicity on protein binding allows the use of ligand capacity factors to predict the routes of elimination of various Tc-HIDAs.

Bile↗

A structure-distribution-relationship approach leading to the development of Tc-99m mebrofenin: an improved cholescintigraphic agent.

Thirty-three HIDA (hepatobiliary IDA) derivatives were tested and correlations drawn between physicochemical parameters, structural effects, and in vivo characteristics. Capacity factors of the ligands on reverse-phase HPLC were used as a measure of lipophilicity, and to predict protein binding and in vivo distribution of the complexes. Fragmentary pi values were used to derive theoretical lipophilicities, which showed that ortho substituents have reduced lipophilic activity, probably because of self-shielding. Ortho substitution was found to affect hepatocellular transit times. Various combinations of substituents with the desired overall lipophilicity were tested. The best compound, Tc-3-bromo-2,4,6-trimethyl HIDA, possessed high hepatic specificity, and rapid hepatocellular transit; it was also resistant to competition for hepatobiliary excretion from bilirubin.

Adipose Tissue↗

Radiopharmaceuticals for hepatobiliary imaging.

Tests for liver function have by and large centered around clinical laboratory diagnostic procedures for a number of years. Besides these, radiographic imaging procedures, including oral cholecystography and intravenous cholangiography, serve a very useful purpose, but several of them are invasive and involve a certain degree of risk from the administered contrast media as well as discomfort to the patient. The cholescintigraphic procedures, though noninvasive, have not played a significant role in the evaluation of hepatobiliary disorders prior to the introduction of the currently available. 99mTc-labeled IDAs. These new hepatobiliary agents offer many advantages over the previously utilized radiopharmaceuticals (131I-rose bengal in particular) in terms of the high degree of specificity for localization in the gallbladder with rapid extraction rates by the polygonal cells of the liver and very low excretion via the GU tract. A detailed understanding of the structure distribution relationship of the various groups in the complex enable the design of agents with an improvement in hepatobiliary specificity and other desirable characteristics. In many clinical situations, even in patients with high bilirubin levels, the 99m-Fc-labeled IDAs offer far superior clinical information over the alternative diagnostic imaging modalities. Further, the absorbed radiation dose imparted to the critical organs is far lower than with the older agents. Thus, the introduction of the cholescintigraphic procedures with the 99mTc-labeled IDAs have ushered in a new phase in the diagnostic workup of patients with impaired hepatocellular function and other biliary disorders.

Biliary Tract↗