Search PubMed⌕ Search

Biomedical subjects

A Cuocolo

Publications and source records attributed to A Cuocolo.

At least 109 records · Page 6Linked to original sources

Reverse redistribution in resting thallium-201 myocardial scintigraphy in patients with coronary artery disease: relation to coronary anatomy and ventricular function.

We studied 25 male patients, with coronary artery disease, mean age 56 +/- 8 yr. All underwent 201Tl rest-redistribution and resting 99mTc methoxyisobutyl isonitrile (MIBI) cardiac imaging. Regional 201Tl and MIBI uptake were quantitatively analyzed. Regional left ventricular wall motion (WM) was visually assessed on MIBI gated images using a three-point scale (0 = normal, 1 = hypokinetic, 2 = a/dyskinetic). Two patterns of reverse redistribution (RR) were identified: RR-A when 201Tl uptake was normal on rest images and abnormal on redistribution images, and RR-B when 201Tl uptake was abnormal on rest images and a significant decrease in uptake was observed on redistribution images. Of the total 375 myocardial segments analyzed, 229 were classified as normal (Nl), 40 as reversible defect (RD), 74 as irreversible defect (ID); 26 showed RR-A while 6 myocardial segments had RR-B. Myocardial segments with RR-A differed from NI in the degree of coronary artery stenosis (81% +/- 33% versus 57% +/- 39%, respectively, p < 0.05), in WM score (1.1 +/- 0.7 versus 0.5 +/- 0.6, respectively, p < 0.01), and in MIBI uptake (81% +/- 10% versus 92% +/- 9%, respectively, p < 0.0001). Moreover, the percent of myocardial segments supplied by a totally occluded coronary artery was significantly higher (p < 0.05) in myocardial segments with RR-A (46%) than in NI (22%). Segments with RR-B did not show any significant difference either from RD and ID. These results suggest that myocardial segments with RR-A on resting 201Tl images have impaired function and are supplied by severely stenosed coronary arteries and should not be considered normal.

Adult↗

Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor.

The accuracy and repeatability of a new ambulatory radionuclide detector (VEST) for left ventricular systolic (ejection fraction) and diastolic (peak filling rate) measurements were assessed. Seventeen patients underwent equilibrium radionuclide angiography immediately before and immediately after a VEST study. The accuracy was evaluated at the beginning and at the end of the VEST studies. Limits of agreement for the ejection fraction were -1%:2% at the beginning of the VEST study and -4%:4% at the end. Limits of agreement for the peak filling rate were -0.6:0.6 at the beginning of the VEST study and -0.7:0.5 at the end. For both measurements the limits of agreement were well within the clinical range. Repeatability was evaluated in a second group of 11 patients who underwent VEST studies in 2 separate days. The coefficient of repeatability (twice the standard deviation of the differences between the 2 studies) was 13 for the ejection fraction and 0.4 for the peak filling rate. Thus, the VEST is an accurate and repeatable method to measure both the ejection fraction and peak filling rate.

Coronary Disease↗

Comparison between exercise and trans-oesophageal atrial pacing in patients with coronary artery disease: technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion.

In this study we compared the results of exercise and trans-oesophageal atrial pacing (TAP) technetium-99m methoxyisobutyl isonitrile (99mTc-SESTAMIBI) cardiac imaging in the evaluation of left ventricular (LV) function and myocardial perfusion in patients with angiographically proven coronary artery disease. Ten patients (8 men and 2 women, mean age 59 +/- 6 years) were submitted to 3 separate injections of 99mTc-SESTAMIBI, one under control conditions, one after exercise and one after TAP. LV ejection fraction, as measured by electrocardiogram (ECG) gated first pass, decreased from 49 +/- 5% under control conditions to 42 +/- 6% during exercise (P less than 0.05 versus control) and to 43 +/- 8% during TAP (P less than 0.05 versus control and insignificant change versus exercise). Segmental myocardial perfusion analysis was performed on a total of 150 myocardial segments. On both exercise and TAP 99mTc-SESTAMIBI studies, 103 segments (69% of the total) were normal, 32 (21%) had reversible, and 15 (10%) irreversible, perfusion defects. Relative regional tracer uptake was not statistically different between exercise and TAP in normal regions (91.1 +/- 9.1% versus 90.7 +/- 8.5%, respectively), in regions with reversible (61.9 +/- 12% versus 62.4 +/- 10.4%, respectively) and irreversible perfusion defects (55.8 +/- 7.8% versus 58.8 +/- 9.5%, respectively). Our results demonstrated that 99mTc-SESTAMIBI TAP cardiac imaging shows similar results to 99mTc-SESTAMIBI exercise myocardial scintigraphy in the assessment of LV function and myocardial perfusion in patients with coronary artery disease.

Cardiac Pacing, Artificial↗

Diagnosis of coronary artery disease with Tc 99m-methoxy isobutyl isonitrile and transesophageal pacing.

Recently the use of a new radioactive agent with physical and biological properties more favorable than those of thallium 201, methoxy-isobutyl-isonitrile (MIBI) labeled with technetium 99m (Tc 99m), has permitted simultaneous performance of perfusion and function studies in ischemic cardiopathy. Transesophageal atrial pacing (TAP) technique has evolved as an alternative provocative test of ischemia. The authors compared the capability of Tc 99m-MIBI myocardial scintigraphy, combined with TAP, with that of Tc 99m-MIBI, combined with maximal stress test, in the diagnosis of ischemic cardiopathy. They studied 11 patients with a clinical history of angina pectoris. Myocardial scintigraphy was performed at rest, after stress test, and after TAP. Finally, all the patients underwent coronary angiography. The analysis of myocardial perfusion images on both Tc 99m-MIBI associated with TAP and with stress demonstrated, in 165 myocardial segments examined: 143 normal, 20 reversible defects, 2 irreversible defects. The concordance of localization between coronarographic data and scintigraphic reversible and irreversible defects was 85%. In conclusion TAP proves to be a valid and sensitive provocative test of ischemia when combined with myocardial scintigraphy and with Tc 99m-MIBI.

Cardiac Pacing, Artificial↗

[Ambulatory monitoring of left ventricular function: the assessment of transient episodes of ventricular dysfunction in patients with ischemic cardiopathy].

BACKGROUND: The recent development of an ambulatory radionuclide detector (VEST) to assess left ventricular (LV) function may enhance the detection of ischemia during routine daily activities in patients with coronary artery disease (CAD). The aim of this study was to evaluate the usefulness of VEST in monitoring LV ejection fraction (EF) responses to daily activities and sustained handgrip test (HG) in patients with CAD. METHODS: 13 patients (12 men and 1 woman) with angiographically proven coronary artery disease were studied by VEST (mean 162 min, range 120 to 250 min). LV responses to different daily activities (walking and climbing stairs) and to HG were evaluated. RESULTS: Walking on a level surface and climbing stairs did not induce significant change in mean LVEF. However, a transient decrease in EF was observed in 4 (31%) and in 5 (38%) of the 13 patients during walking and climbing stairs, respectively. HG induced a significant (p < 0.01) reduction in mean EF. In particular, during HG, EF decreased > or = 5% in 11 (85%) of the 13 patients. A transient spontaneous decrease in LVEF lasting > or = 1 min was observed on 18 occasions in 11 patients with CAD; 5 episodes were symptomatic and 13 asymptomatic. ECG ST segment depression was recorded in 4 of the 5 symptomatic and in 5 of the 13 asymptomatic episodes. CONCLUSIONS: These results suggest that simultaneous monitoring of LV function and ECG may permit a better understanding of the incidence and severity of ischemic symptomatic and asymptomatic episodes.

Aged↗

Identification of viable myocardium in patients with chronic coronary artery disease: comparison of thallium-201 scintigraphy with reinjection and technetium-99m-methoxyisobutyl isonitrile.

We compared the results of 201Tl reinjection and those of 99mTc-methoxyisobutyl isonitrile (MIBI) in identifying viable myocardium in 20 male patients with angiographically proven coronary artery disease (CAD) and left ventricular dysfunction (ejection fraction 30% +/- 8%). All patients had irreversible defects on standard exercise-redistribution thallium imaging. Thallium was reinjected immediately after the redistribution study, and images were reacquired. The patients also underwent stress and rest 99mTc-MIBI myocardial scintigraphy (2-day protocol). A total of 300 myocardial regions were analyzed, of which 122 (41%) had irreversible thallium defects on redistribution images before reinjection. Of the 122 myocardial regions with irreversible defects on standard stress-redistribution thallium cardiac imaging, 65 (53%) did not change at reinjection and 57 (47%) demonstrated enhanced uptake of thallium after reinjection. Of the same 122 irreversible defects on stress-redistribution thallium, 100 (82%) appeared as fixed defects and 22 (18%) were reversible on 99mTc-MIBI myocardial scintigraphy. These data indicate that 201Tl cardiac imaging with rest reinjection is superior to 99mTc-MIBI myocardial scintigraphy in identifying viable myocardium in patients with chronic CAD, suggesting that regions with severe reduction of 99mTc-MIBI uptake both on stress and rest images may contain viable myocardium.

Adult↗

Misalignment between PET transmission and emission scans: its effect on myocardial imaging.

Patient movement between PET scanning sequences can produce misalignment between attenuation and emission scans. Such misalignment introduces errors in the emission image. This study evaluates the severity of these errors and their effect upon quantitation of regional myocardial activity. Myocardial FDG scans from 14 patients were reconstructed with simulated translational, rotational and out-of-plane patient movement. Eight myocardial regions from each patient were examined to determine the effect such misalignment might have on regional myocardial activity. A 2-cm shift between attenuation and emission scans produced up to a 30% change in regional activity. Some regions of the myocardium increased while others decreased for a given magnitude and direction of shift, producing anomalous regional myocardial inhomogeneities in the image. Such changes could easily cause qualitative and quantitative misinterpretations. We present data permitting the reader to assess the magnitude of this effect in his/her own clinical setting.

Cardiomyopathy, Hypertrophic↗

Effects of atrial natriuretic peptide on glomerular filtration rate in essential hypertension: a radionuclide study.

A number of studies show that atrial natriuretic peptide (ANP) raises renal sodium excretion with a concomitant increase in glomerular filtration rate (GFR) in both experimental animals and normal humans. Studies using indirect evaluation of GFR have provided less consistent results in hypertensive patients. We studied the effects of intravenously administered (iv) alpha-human ANP on GFR in patients with hypertension by a radionuclide technique using technetium 99m diethylenetriaminepenta-acetic acid. In six patients (ANP group), GFR was determined under control conditions, during iv ANP (initial bolus of 0.5 micrograms/kg followed by a 21-min maintenance infusion at 0.05 micrograms.kg-1.min-1) and during a recovery phase. In six other patients (control group), GFR was determined under control conditions, during saline iv infusion and during recovery. The two groups did not differ with respect to age, sex, basal blood pressure, heart rate or GFR. In the ANP group, the infusion of the peptide induced a significant decrease of mean blood pressure (from 133 +/- 5 to 120 +/- 5 mmHg, P less than 0.01), no change in heart rate and a significant increase in GFR (from 104 +/- 4 to 125 +/- 5 ml/min, P less than 0.01). During recovery, blood pressure, heart rate and GFR were not different from the values recorded under control conditions. No changes in blood pressure, heart rate or GFR (from 106 +/- 5 to 108 +/- 5 ml/min, n.s.) were detected during saline infusion in the control group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Comparison of thallium scintigraphy with reinjection and PET imaging with 18F-fluorodeoxyglucose.

In patients with chronic coronary artery disease and left ventricular dysfunction, the distinction between ventricular dysfunction arising from myocardial fibrosis and ischemic, but viable, myocardium has important clinical implications. By positron emission tomography (PET), enhanced fluorine-18-labeled fluorodeoxyglucose (FDG) uptake in myocardial segments with impaired function and reduced blood flow is evidence of myocardial viability. Reinjection of thallium-201 at rest immediately after stress-redistribution imaging may also provide evidence of myocardial viability by demonstrating thallium uptake in regions with apparently "irreversible" defects. To compare these two methods, we studied 16 patients with chronic coronary artery disease and left ventricular dysfunction (ejection fraction, 27 +/- 9%), all of whom had irreversible defects on standard exercise-redistribution thallium single-photon emission computed tomography (SPECT) imaging. Thallium was reinjected immediately after the redistribution study, and SPECT images were reacquired. The patients also underwent PET imaging with FDG and oxygen-15-labeled water. A total of 432 myocardial segments were analyzed from comparable transaxial tomograms, of which 166 (38%) had irreversible thallium defects on redistribution images before reinjection. FDG uptake was demonstrated in 121 (73%) of these irreversible defects. Irreversible defects were then subgrouped according to the degree of thallium activity, relative to peak activity in normal regions. Irreversible defects with only mild (60-85% of peak activity) or moderate (50-59% of peak) reduction in thallium activity were considered viable on the basis of FDG uptake in 91% and 84% of these segments, respectively. In contrast, in irreversible defects with severe reduction in thallium activity (less than 50% of peak), FDG uptake was present in 51% of segments. In such severe defects, an identical number of segments (51%) demonstrated enhanced uptake of thallium after reinjection. In these severe "irreversible" defects, data on myocardial viability were concordant by the two techniques in 88% of segments, with 45% identified as viable and 43% identified as scar on both PET and thallium reinjection studies. These observations suggest that thallium imaging can be used to identify viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Most irreversible defects with only mild or moderate reduction in thallium activity represent viable myocardium as confirmed by FDG uptake.(ABSTRACT TRUNCATED AT 400 WORDS)

Coronary Disease↗

[131I-meta-iodobenzylguanidine scintigraphy in patients with a suspected pheochromocytoma. A comparison with CT and biohumoral parameters].

The results of 131I metaiodobenzylguanidine (MIBG) and Computed Tomography (CT) scans in a group of patients with clinically suspected pheochromocytoma were evaluated and compared with biohumoral parameters. We studied 24 consecutive patients (7 M and 17 F; age range 20-66 years). 131I-MIBG scintigraphy and CT were in agreement in 19 patients (79%): of them 7 cases were true positive, and 12 were true negative. Disagreement between the two imaging techniques was observed in 5 patients (21%). In this group, one patient, with positive CT scan, had false negative MIBG study, while 4 patients with negative MIBG scan, had false positive CT. MIBG showed significantly higher (p less than 0.05) specificity (100%), positive predictive value (100%), and accuracy (96%) than CT (75%, 67%, and 83%, respectively). 131I-MIBG scintigraphy is an accurate, noninvasive technique for localizing pheochromocytoma and providing direct tissue characterization, while CT provides more accurate spatial information. In conclusion, CT and MIBG studies are complementary in the evaluation of patients with suspected pheochromocytoma.

3-Iodobenzylguanidine↗

[Morpho-functional evaluation of hypertensive patients with renal artery stenosis. Correlations between angiography and dynamic scintigraphy].

Renovascular hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and function, and to compare functional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal imaging with 99mTc diethylenetriaminepentaacetic acid (DTPA) and 131I ortho-iodohippurate (OIH), and renal arteriography were also employed in all patients. In all patients, radionuclide results matched angiographic findings in quality. In particular, 3 patients with hemodynamically insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r = 0.866, p less than 0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable tool in the assessment of functional changes secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography.

Adolescent↗

Left ventricular hypertrophy and impaired diastolic filling in essential hypertension. Diastolic mechanisms for systolic dysfunction during exercise.

Left ventricular ejection fraction is normal at rest but may respond abnormally to exercise in many patients with essential hypertension. To assess the determinants of the abnormal ejection fraction response to exercise, we performed radionuclide angiography at rest and during exercise in 41 hypertensive patients without coronary artery disease. In 22 patients (group 1), the ejection fraction increased more than 5% during exercise; in the other 19 patients (group 2), the ejection fraction either increased by less than 5% or decreased with exercise. Left ventricular diastolic filling was impaired at rest in patients in group 2 compared with group 1, with reduced peak filling rate (2.5 +/- 0.4 vs. 3.1 +/- 0.7 end-diastolic volume/sec; p less than 0.01) and prolonged time to peak filling rate (175 +/- 28 vs. 153 +/- 22 msec; p less than 0.01). Impaired diastolic filling in group 2 was associated with less augmentation in end-diastolic volume during exercise compared with group 1 (p less than 0.01). These observations were not dependent on the threshold value that was arbitrarily chosen to define an abnormal ejection fraction response, as there were significant correlations for the entire group between the magnitude of change in ejection fraction with exercise and both the resting peak filling rate (r = 0.46) and the change in end-diastolic volume with exercise (r = 0.62).(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiomegaly↗

Radionuclide renography predicts functional changes in patients with renal artery involvement by Takayasu's arteritis.

Renovascular hypertension is a major complication of Takayasu's arteritis, which contributes to the high mortality associated with the disease. We studied 5 patients affected by different degrees of Takayasu's arteritis to assess the usefulness of radionuclide renography in evaluating renal perfusion and function, and to predict changes induced by the disease before and after therapeutic interventions. Computer-assisted dynamic renal imaging with Tc-99m diethylenetriaminepentaacetic acid (DPTA) and I-131 orthoiodohippurate (OIH), and renal arteriography were concurrently performed in all patients. Two patients with hemodynamically insignificant renal artery stenosis showed normal perfusion and function by renography. Three patients had significant renal artery stenosis and functional changes on renography. Subsequently, two of these patients had successful therapy (one had bilateral renal artery bypass grafts, and the other had renal artery angioplasty), and both showed functional improvement at renography. Our results demonstrate that radionuclide renography is valuable in the assessment of functional changes induced by Takayasu's arteritis as well as for determining the response to therapeutic interventions.

Adolescent↗

Influence of volume expansion on hemodynamic effects of atrial natriuretic factor in rabbits.

We investigated the influence of acute volume expansion on the hemodynamic and renal responses to the constant infusion of atrial natriuretic factor (ANF) (alpha-human ANP, 2 micrograms/kg bolus, 0.2 microgram.kg-1.min-1) in rabbits anesthetized with ketamine and acepromazine. The effects of the peptide were evaluated in 12 euvolemic rabbits and in 15 rabbits during the steady-state phase of volume expansion (0.9% NaCl 4.5 ml/min for 60 min). In the euvolemic animals, ANF caused an increase in natriuresis and a reduction in blood pressure (BP), which was associated with a decrease in cardiac output (CO), stroke volume (SV), and no significant changes in central venous pressure (CVP), peripheral hematocrit (Hct), and heart rate (HR). When the peptide was infused in the volume-expanded animals, the effects of ANF on BP and HR were comparable with those observed in the euvolemic animals. However, in these animals the ANF-induced changes in CO, SV, CVP, and Hct were significantly greater than those observed in the euvolemic group. In addition, the percent increases in diuresis and natriuresis were significantly smaller than those obtained in the euvolemic animals. In conclusion, volume expansion with saline potentiates the effects of ANF on systemic hemodynamics and blood volume.

Animals↗

Renal artery stenosis detection by combined Gates' technique and captopril test in hypertensive patients.

We studied 11 hypertensive patients by a radionuclide technique using Gates' method with [99mTc]DTPA to investigate the acute effects of captopril on glomerular filtration rate (GFR). Five patients had hypertension with unilateral renal artery stenosis (RAS) angiographically documented and six patients had essential hypertension (EH). Total and split GFR were determined under control conditions and after oral administration of captopril (50 mg). In the patients with RAS, captopril induced a significant decrease of GFR in the stenotic kidneys (from 42.4 +/- 4 to 29.6 +/- 3 ml/min, p less than 0.01), while no changes were observed in the nonstenotic kidneys (from 61.2 +/- 3 to 61.6 +/- 5 ml/min, NS). Total GFR was 103.6 +/- 5 ml/min under control conditions and decreased to 91.8 +/- 6 ml/min after captopril (p less than 0.05). No significant changes of GFR were detected after captopril administration in patients with EH. In a separate group of ten patients with EH, good correlation between 24-hr creatinine clearance and fractional uptake of [99mTc]DTPA was obtained. Good reproducibility of this radionuclide technique was also shown. This study demonstrates that the computed radionuclide GFR determination coupled with the captopril test allows one to unmask angiotensin II-dependent renal function and hemodynamic changes. This technique can be useful in clinical practice for identifying patients with renovascular hypertension.

Adult↗