[3 years' use of timolol in chronic open-angle glaucoma].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Chagnon.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A simple tissue microculture technique was developed for the titration of a cytoplasmic polyhedrosis virus (CPV) from Euxoa scandens. The procedure was similar to the 50% tissue culture infectious dose assay, but a single infected cell, detected by the presence of cytoplasmic polyhedra, was scored rather than the degeneration of cell monolayers. The filtration of CPV suspensions resulted in decreased virus titers under certain conditions. This microculture assay was used to determine the effect of cell disruption methods on virus yields. Sonication of infected cells was more efficient than freeze-thawing for the recovery of nonoccluded virus.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Mycoplasma contaminants of animal and human cell cultures were rapidly detected and identified by an indirect immunofluorescent technique. Cells suspected of being contaminated by mycoplasmas were grown as monolayers on chamber slides in a culture medium selected to promote mycoplasmal growth. Before fixation by acetone, the monolayers were subjected to a hypotonic treatment to cause swelling of the mycoplasmas. Detection and identification were then performed by indirect immunofluorescence using rabbit antisera to various mycoplasma species. The correlation between results obtained by the standard isolation procedure and those obtained by this method was very close.
Following a seventeen weeks study including 110 patients with open-angle glaucoma, 81,8% of the patients treated by timolol, administered twice a day, had a satisfactory control of their intraocular pressure, against only 41,8% of those patients treated by pilocarpine, administered four times a day. The side effects liable to timolol are clinically reduced, in a osit with pilocarpine which is followed by a series of well-known subjective and objective signs often causing discomfort to the patients.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Vero cells were more suitable then BHK-21 cells for the detection of rubella-specific IgG antibodies because the nonspecific fluorescence was minimal. However, BHK-21 cells were found more sensitive than Vero cells for the detection of rubella-specific IgM antibodies.
The fluorescence obtained with an incident light system is higher than that obtained with a transmitted light system. Examination time is reduced and the strain on the eyes, after long periods, is reduced. However, the results are the same whatever the system used.
The relative value of heterophil agglutinins (HA) and of specific EBV antibodies in the diagnosis of infectious mononucleosis (IM) was assessed in 108 cases of the disease and in 280 controls. Among the 108 cases 93 were HA-positive by sheep cells in at least one of their sera, while 15 were HA-negative by the same test. Among the 280 controls false-positive HA tests were not encountered except in eight cases with the horse cell microtitre tests. With one of the two slide tests at least two false-positive tests and 12 false-negative tests were also found but these sera had low titres in microtitre tests. The HA life-span was found to be unexpectedly long in a few cases, sheep cell HA lasting up to 8 to 10 months and horse cell HA up to 21 to 23 months.Many false-positive tests may therefore not be true false-positives and may result from the persistence of HA following unrecognized mononucleosis months before. Virtually all cases of IM had (or developed) antibodies to Epstein-Barr virus, viral capsid antigen (EBV-VCA), whereas only half of the controls were EBV-VCA-positive. The comparative analysis of nonspecific and specific test results in mononucleosis allows the following conclusions: (1) horse cell microtitre tests and the monospot test are more sensitive than sheep cell microtitre tests and the monotest; (2) false-negative results are occasionally seen with the latter tests but not with the former; (3) more false-positive results, however, are probably seen with the former tests; and (4) specific EBV-IgM and EBV-EA antibody tests are useful in the diagnosis of selected borderline cases of mononucleosis.
Explore the source record for details and available documents.