Search PubMedSearch

Biomedical subjects

A Cavalleri

Publications and source records attributed to A Cavalleri.

At least 19 recordsLinked to original sources

Detection of nonthermal melting by ultrafast X-ray diffraction.

Using ultrafast, time-resolved, 1.54 angstrom x-ray diffraction, thermal and ultrafast nonthermal melting of germanium, involving passage through nonequilibrium extreme states of matter, was observed. Such ultrafast, optical-pump, x-ray diffraction probe measurements provide a way to study many other transient processes in physics, chemistry, and biology, including direct observation of the atomic motion by which many solid-state processes and chemical and biochemical reactions take place.

Biochemistry

Determination of S-phenylmercapturic acid in urine as an indicator of exposure to benzene.

S-phenylmercapturic acid (S-PMA) was measured in urine from 145 subjects exposed to low benzene concentrations in the air (C(I), benzene). The 8-h, time-weighted exposure intensity of individual workers was monitored by means of charcoal tubes and subsequent gas-chromatographic analysis after desorption with CS2. S-PMA excretion level in urine was determined by high-performance liquid chromatography with fluorescence detection. The following linear correlation was found between S-PMA concentrations in urine and benzene concentrations in the breathing zone: log(S-PMA, microg/g creatinine) = 0.712 log (C(I)-benzene, ppm) + 1.644 (n = 145, r = 0.74, P < 0.001). The geometric mean (GSD) of S-PMA concentrations in urine from 45 subjects occupationally not exposed to benzene but smoking more than 20 cigarettes/day was 7.8 microg/g creatinine (2.11), the corresponding value among non-smokers being 1.0 microg/g creatinine (2.18). It is concluded that the urinary level of S-PMA can be regarded as a useful indicator of exposure to benzene.

Acetylcysteine

Reversible color vision loss in occupational exposure to metallic mercury.

Color vision was evaluated in twenty-one mercury exposed workers and referents matched for sex, age, tobacco smoking, and alcohol habits. The Lanthony 15 Hue desaturated panel (D-15 d) was applied. In the workers, mean urinary Hg (HgU) was 115+/-61.5 microg/g creatinine; in all but one the values exceeded the biological limit (BEI) proposed by the American Conference of Governmental Industrial Hygienists. A dose-related subclinical color vision impairment was observed in Hg-exposed workers compared to the referents. Just after the survey, working conditions were improved. Twelve months later the workers were reexamined. Mean HgU was 10.0 microg/g creatinine and in no subjects was the BEI exceeded. Color perception was significantly improved compared to the first examination and, furthermore, no differences were observed between exposed workers and referents. The results add evidence that the color vision loss observed during the first part of the study was related to Hg exposure and, moreover, show that this effect is reversible. These data indicate that metallic Hg can induce a reversible impairment in color perception. This suggests that color vision testing should be included in studies on the early effects of Hg. The possibility of applying the D-15 d as an early effect index in the biological monitoring of Hg exposed workers should also be entertained.

Adult

The urinary excretion of solvents and gases for the biological monitoring of occupational exposure: a review.

'In the field' application of the measurement of urinary excretion of unmodified solvent for the biological monitoring of exposed workers has been investigated in many recent papers. The results obtained for several solvents are reviewed. The values of correlation coefficients (r) and regression lines obtained for benzene, toluene, xylene, styrene, n-hexane, cyclohexane, 2- and 3-methylpentane, methyl chloride, tetrachloroethylene, carbon tetrachloride, methyl chloroform, p-dichlorobenzene, nitrous oxide, halothane, isoflurane, enflurane, acetone, methyl ethyl ketone and methyl isobutyl ketone are presented. The correlations observed were generally good: r values range from 0.50-0.97, and the majority are between 0.84 and 0.90. The regression lines reported for the same solvent in different studies present some variability: this is possibly due to an inadequate control of factors influencing the relationship between external dose and absorption, such as differences in body burden, work load, individual characteristics, etc. These factors are discussed. As a whole, results reported in the literature show that measuring of urinary excretion of unmodified solvents provides a highly sensitive and specific exposure index, and can also be applied for the biological monitoring of occupational exposure to low levels of solvents or to solvent mixtures. Nevertheless, for an adequate assessment of biological limit values, further studies evaluating the reproducibility of regression lines are needed, given that the aspects influencing the correlation between external dose and urinary excretion are fully controlled. Another crucial aspect is the correlation with early effects: even though this has yet to be evaluated for several solvents, for others such as styrene and perchloroethylene a good correlation was obtained, further supporting the usefulness of the measurement of urinary excretion of solvent for the biological monitoring of occupational exposure.

Absorption

Excretion of N-acetyl-S-(1-phenyl-2-hydroxyethyl)-cysteine and N-acetyl-S-(2-phenyl-2-hydroxyethyl)-cysteine in workers exposed to styrene.

Styrene (S) has been shown to be responsible for neurotoxic effects, including behavioural changes and neuroendocrine disturbances. The initial step of S metabolism is conversion to styrene 7,8-epoxide (SO), which is present in two enantiomeric forms [(R)(+)-SO and (S)(-)-SO]; this electrophilic intermediate is considered to be directly responsible for most toxic effects of S. The major urinary metabolites derived from the biotransformation of SO in man are mandelic acid (MA) and phenylglyoxylic acid (PGA). In rats an alternative pathway has been demonstrated, which involves the conjugation of SO to glutathione (GSH), leading to the excretion of two specific mercapturic acids, N-acetyl-S-(-(1-phenyl-2-hydroxyethyl)-cysteine [M1] and N-acetyl-S-(2-phenyl-2-hydroxy-ethyl)-cysteine [M2]; a close relationship has been found between exposure to S and urinary excretion of M1 and M2 in rats. As a consequence of the chiral nature of SO, both M1 and M2 consist of two diastereoisomers (M1-'R', M1-'S', M2-'R' and M2-'S'). Early reports have shown that the conversion of S to mercapturic acids is much lower in man (below 1% of the absorbed dose) than in rats (about 10%). We propose an analytical method for the determination of urinary M1 and M2 in man, which involves a urine clean-up by a chromatographic technique with a short reversed-phase pre-column; purified samples are then deacetylated with porcine acylase and deproteinized by centrifugal ultrafiltration. A derivatization is then performed with o-phthaldialdehyde and 2-mercaptoethanol and the fluorescent derivatives are separated on a reversed-phase analytical column. The mobile phase consists of acetate buffer and methanol mixed at variable proportions, the fluorescence detector is set at 330 nm (exc.) and 440 nm (em.). M1-'S' and M1-'R' are separated (retention times = 52.8 and 73.7 min, respectively) while the diastereoisomers of M2 coelute as a single peak at 70.5 min. The detection limit is about 7 micrograms/l, the coefficients of variation are below 7% and the error percentages are less than 6%. The method was applied to 25 urine samples from workers exposed to S: significant correlations were found between mercapturic acids and MA and PGA, the best correlation being between M2 and PGA (r = 0.79). Urine samples form unexposed subjects showed no detectable amounts of the analytes. A high stereoselectivity is shown by the enzymes involved in the metabolism of S to mercapturic acids: M1-'S', which derives from (S)-SO, is excreted in much higher amounts than M1-'R', which derives from (R)-SO.

Acetylcysteine

Urinary excretion of specific mercapturic acids in workers exposed to styrene.

Styrene is an important chemical of wide industrial use, particularly in the manufacture of polymers and reinforced plastics. Environmental and occupational exposures to styrene occur predominantly via inhalation. Styrene undergoes biotransformation mainly by side chain oxidation catalyzed by cytochrome P-450 enzymes to its reactive metabolite, styrene oxide. The (R)- and (S)-enantiomers of styrene oxide can be conjugated with glutathione to both (R)- and (S)-diastereoisomers of specific mercapturic acids, N-acetyl-S-(1-phenyl-2-hydroxyethyl)-L-cysteine (M1) and N-acetyl-S-(2-phenyl-2-hydroxyethyl)-L-cysteine (M2). We conducted this biomonitoring study with the aim of evaluating the association between excretion of specific mercapturic acids (M1 and M2) and level of exposure to styrene among occupationally exposed people. The mean time-weighted average (TWA) exposure was about one-half the current threshold limit value, the range of the values varied from 44 to 228 mg/m3. Geometric mean (GM) concentrations of 650, 1,084, and 31.8 micrograms/g creatinine were measured, respectively, for M1-S, M2, and M1-R. The environmental styrene concentration exhibited a significant correlation with total specific mercapturic acid (Mtot = sum of M1-R, M1-S, and M2), making it possible for the first time to calculate the approximate relationship between styrene uptake and excretion of these substances. The M2 mercapturic acid had a better correlation (r = 0.56) with respect to M1-R and M1-S. Significant correlations were found also between the excretion of specific mercapturic acids and biological exposure indices (i.e., mandelic and phenylglyoxylic acids and urinary styrene).

Acetylcysteine

[Precordial discomfort and ECG changes of repolarization associated with hypomagnesemia in a young women following colectomy for diffuse colonic lipomatosis].

Aim of this paper is to describe and discuss, on the basis of the available literature, the case of a young woman, previously colectomized for diffuse lipomatosis of the colon, showing hypomagnesemia and symptomatic (precordial discomfort) changes of repolarization phase, detected by ECG, probably due to coronary spasm. This hypomagnesemia (1.4 mEq/1) was probably due to altered intestinal absorption of magnesium, linked to a short bowel syndrome. The ECG changes and the precordial symptom were completely reversed by a relative short treatment with magnesium per os, which increased the magnesium level to low borderline value (1.6 mEq/1). The observation of ECG changes with precordial discomfort, probably linked to hypomagnesemia, suggests the need for routinary magnesium determinations to detect deficiency of this electrolyte, with the scope of improving the diagnosis and the treatment of several symptoms, otherwise difficult to interpret.

Adult

Color vision loss among styrene-exposed workers neurotoxicological threshold assessment.

Styrene represents nowadays one of the most used organic solvent. The current exposure limit proposed for this chemical differs significantly from country to country: the Threshold Limit Value-Time Weighted Average (TLV-TWA) proposed by the American Conference of Governmental Industrial Hygienists (ACGIH) is 50 ppm while the German, Finnish and Swedish occupational exposure limit is 20 ppm. Nevertheless, effects on the nervous system were recently reported in workers exposed at TWA styrene levels below the current TLV. Neuro-optic pathways have been shown to be particularly vulnerable to organic solvent exposure. Analysis and measurements of visual functions can provide important information on early neurotoxic effects. Previous studies support the hypothesis that styrene exposure can induce a dose-dependent color vision loss. The aim of this study is to assess a threshold level below which no detectable effect occurs for color vision. We applied a sub-application of the change point problem in two-phase regression considering one phase as a constant line. In accordance with this model the maximum-likelihood technique was used as a method to examine the dose- effect relationship between external styrene exposure and chromatic discrimination. The present article presents a joint analysis of data from two previously published studies, one carried out in Canada and the other in Italy. The age and seniority of the workers from both countries were remarkably similar, as were the process type, the chemicals used and the work-tasks of exposed subjects. The mathematical method presented here shows the existence of a statistically significant threshold. This finding shows that, in fiberglass-reinforced plastics industry, visual color impairment could be significantly detected above 4 ppm (upper limit of the confidence interval at 5% = 26 ppm). The exact clinical meaning of this effect, and also the progress of the impairment in exposed workers, is still to be assessed in further studies. The results of our study support the need of a reduction of the occupational limits for styrene in workplaces to values close to or lower than German, Finnish or Swedish exposure limits.

Adult

Methods for urinary testosterone analysis.

Urinary testosterone analysis requires a multistep procedure to achieve a good degree of sensitivity and specificity in the dosage. Hydrolysis, extraction, purification and quantification are usually performed in sequence, and several options can be chosen for each of them. After introductory remarks on the applications of urinary testosterone measurement and a short description of the metabolic pathway of the hormone, an overview of the techniques most commonly used in each step is presented. Advantages and disadvantages of each of them are outlined, and a procedure for urinary testosterone analysis is suggested. The procedure consists of: enzymatic hydrolysis with Helix pomatia juice, followed by solid-phase extraction of hydrolyzed urine by a C18 cartridge coupled with an NH2 cartridge and high-performance liquid chromatography cleanup of the extract. Then, quantification can be achieved by gas chromatography or radioimmunoassay.

Chromatography, Affinity

Colour vision loss in workers exposed to elemental mercury vapour.

We evaluated colour vision in 33 workers exposed to elemental mercury (Hg) vapour and in 33 referents matched for sex, age, alcohol consumption and cigarette smoking. The results were expressed as colour confusion index (CCI). In the workers urinary excretion of Hg (HgU) ranged from 28 to 287 micrograms/g creatinine. Subclinical colour vision loss, mainly in the blue-yellow range, was observed in the workers. This effect was related to exposure, as indicated by the correlation between HgU and CCI (r = 0.488, P < 0.01). In the workers whose HgU exceeded 50 micrograms/g creatinine, mean CCI was significantly increased compared to the matched referents. The results suggest that exposure to elemental Hg inducing HgU values exceeding 50 micrograms/g creatinine can induce a dose-related colour vision loss.

Adult

Testosterone, dihydrotestosterone and oestradiol levels in postmenopausal breast cancer tissues.

The ability of breast tumours to synthesize hormones is well recognized, and local production of sex steroids is thought to play a role in breast cancer growth. We measured the intratumour and circulating levels of testosterone, dihydrotestosterone (DHT) and oestradiol in 35 histologically confirmed carcinomatous mammary tissues obtained at breast surgery from 34 postmenopausal patients, age 50-85 years. Intra-tissue steroids were extracted with ethanol:acetone (1:1; v/v), defatted with 70% methanol in water, and extracted with ether. Steroids, from tissue and serum, were separated by partition chromatography on celite columns and were measured by RIA. Intratumour testosterone and DHT concentrations were significantly correlated, after the exclusion of an outlier (rs = 0.71; P = 0.0001). No association was found between oestradiol and either of the two androgens. Mean oestradiol and DHT concentrations were significantly higher in tissue than in blood (P = 0.0001). Mean testosterone levels in tissues did not significantly differ from those measured in blood. Our data suggest that at least a part of intratissue DHT is produced locally from testosterone. The meaning of high oestradiol and DHT levels in cancer tissue still needs to be defined.

Aged

Perchloroethylene exposure can induce colour vision loss.

We evaluated colour vision in 35 dry-cleaners exposed to perchloroethylene (PCE) and in a paired number of controls matched for sex, age, alcohol consumption and cigarette smoking. A subclinical colour vision loss, mainly in the blue-yellow range, was present in dry-cleaners. This effect was related to PCE exposure levels, and appeared at environmental concentrations of the solvent well below the current exposure limits for exposed workers. The results suggest that PCE exposure, even at low environmental levels, can induce a dose-related impairment of colour vision.

Adult

Testosterone levels as a marker of prognosis to goserelin treatment in metastatic breast cancer.

Testosterone levels were measured in blood and urine of 35 premenopausal metastatic breast cancer patients before starting therapy with the gonadotrophin-releasing hormone (GnRH) analogue, goserelin. The aim of the study was to verify the reliability of testosterone measurement as a marker of prognosis. The time interval between starting therapy and progressive disease (time to progression) was chosen to assess prognosis. Univariate and multivariate analysis showed that only urinary testosterone levels were significantly associated with time to progression (Wald test 6.66, P = 0.01 for univariate and Wald test 7.93, P = 0.0049 for multivariate analysis), whereas no association was found for testosterone in blood. A statistical model is proposed to evaluate probability of progressive disease in relation to testosterone values in urine at different times. According to the model, the probability of progression decreases with increasing urinary testosterone values.

Adult

Urinary styrene in the biological monitoring of styrene exposure.

The urinary excretion of styrene represents a promising indicator of exposure to this solvent. Nevertheless extensive research under field conditions is scant. In this investigation 214 styrene-exposed workers from 10 fiberglass-reinforced plastics factories were studied. Environmental monitoring was performed by personal passive sampling. Blood styrene and the urinary excretion of styrene and its main metabolites, mandelic acid (MA) and phenylglyoxylic acid (PGA), were measured. The correlation coefficient between the time-weighted average of environmental styrene and the mean urinary excretion of styrene was 0.88 (0.91 after logarithmic transformation), compared with the 0.82 and 0.78 of the end-of-shift MA and PGA values, respectively. A high correlation (0.86) was also found between styrene in the blood and urine. The results, obtained under field conditions with a large group of exposed workers, confirm the usefulness of the urinary excretion of styrene as an exposure index for the biological monitoring of styrene exposure.

Adolescent

Kinetics of urinary excretion and effects on colour vision after exposure to styrene.

We evaluated the influence of the body burden of styrene on biological indices of exposure and the effects of this solvent on colour perception. The exposure of 19 workers was followed during a working week by personal sampling and biological monitoring. Although no significant difference in daily exposure was observed, pre-shift values of urinary styrene and urinary mandelic acid increased significantly during the week, and the regression line between external dose and biological exposure indices changed correspondingly. These data suggest that body burden can influence the results of biological monitoring of styrene. The effect of styrene on colour vision was evaluated in two further groups: 73 exposed workers and 53 referents and 36 pairs of workers and controls. A dose-related impairment was observed, which appeared to be synergistic with age and was not significantly improved by a one-month interruption of exposure. Our data show the need to improve biological monitoring of exposure to styrene and, in particular, to establish dose-effect and dose-response relationships between exposure and early effects. Urinary excretion of styrene and colour vision assessment represent, respectively, promising indices of exposure to and an effect of styrene.

Adult

Urinary testosterone measurement by gas chromatography after solid-phase extraction and high-performance liquid chromatography.

A method was developed for the rapid determination of testosterone in urine. The procedure consists of solid-phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) clean-up before gas chromatographic determination. Recovery was evaluated by adding [3H]testosterone (10(4) cpm) to urine samples; the mean recovery of radioactivity after SPE and HPLC was 82%. Precision was estimated by repeated measurement of testosterone in four different urine samples; the coefficient of variation was 7.9% (95% confidence limits 6.1-11.4%). Accuracy was evaluated by standard addition and dilution assays; a linear relationship was found between the expected and observed values (r2 = 0.982). The method is rapid, effective and suitable for routine analysis.

Chromatography, Gas

Trace element reference values in tissues from inhabitants of the European Community. III. The control of preanalytical factors in the biomonitoring of trace elements in biological fluids.

In the context of a programme concerning the determination of trace elements in body fluids and tissues to establish trace element reference values, research has been undertaken on the control of preanalytical factors in order to develop sufficiently accurate and precise guidelines to be applied in routine work by using techniques such as graphite furnace atomic absorption spectroscopy (GFAAS). Aspects investigated are related to the risk of contamination during blood collection and the use of anticoagulants; the risk of losses during storage and freeze-drying as well as the possible risk of contamination arising from trace elements in airborne particulates of the laboratory environment. For the analysis of Al, Ba, Cd, Co, Cr, Mn, Mo, Ni, Sb, W, V and Zn in blood, Teflon cannula is the method of choice. The anticoagulants do not introduce disturbing contaminations of Rb, Se, Zn, while contaminations were observed for Co, Cr, Mn. Radiotracers in 'metabolized form' (radiolabelled rat or rabbit tissues from animals administered with radioisotopes) show that samples stored for 1 month at -20 degrees C have no significant trace metal losses. Strict ambient air quality standard has to be respected (continuous monitoring) due to the possibility of element contaminations inside the laboratory. The use of matrix modifiers could represent a toxicological risk to the operators. Critical factors should be considered ('metal sheets') for each element in each matrix. For instance 27 factors for Cr in serum have been suggested.

Air Pollutants, Occupational