Search PubMed⌕ Search

Biomedical subjects

A C Lewis

Publications and source records attributed to A C Lewis.

At least 19 recordsLinked to original sources

Structural analysis of oligomeric molecules formed from the reaction products of oleic acid ozonolysis.

The products arising from the ozonolysis of oleic acid (cis-9-octadecenoic acid) in solution have been studied using negative ion mode electrospray ionization ion trap mass spectrometry. Oleic acid is an important component of atmospheric organic aerosol and is a key model species in predicting aerosol physical and chemical characteristics. The four predicted reaction products, 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, were all observed in roughly equal yields. In addition to these products a large number of higher molecular weight compounds were detected with m/z ratios of up to 1000 Daltons. Tandem mass spectrometry of these larger ions revealed thatthey represented a complex mixture of linear alpha-acyloxyalkyl hydroperoxides, secondary ozonides, and cyclic diperoxides, formed by reactions between ozonolysis products and Criegee intermediates. These comprise the first directly elucidated structures of large oligomeric species from oleic acid ozonolysis. The degree of oligomerization and hence molecular weight distribution was observed to increase with reaction time in solution.

Aldehydes↗

An observational case study of ozone and precursors inflow to South East England during an anticyclone.

Summertime photochemical air pollution episodes within the United Kingdom have been proposed via modelling studies to be strongly influenced by regional scale inflow of air from the continental European boundary layer. We present a vertically resolved case study using measurements made from the NERC/Met Office BAe 146 research aircraft on 18th August 2005 over the South East of England and the North Sea during a weak anticyclone centred over Northern Europe. The vertical distribution of ozone, CO, NO(x), peroxyacetyl nitrate (PAN) and a wide range of both nonmethane hydrocarbons (NMHC) and oxygenated volatile organic compounds (OVOCs) were determined between 500 ft (approximately 152 m) and 7000 ft (approximately 2134 m) over the East Anglia coastline and 50 km inland. In excess of 80 ppbV ozone was observed within inflowing boundary layer air over the North Sea coast in a broad N-S sloping feature around 60 km wide. The inflowing feature of European origin was also observed further inland within the boundary layer albeit with lower, more variable, ozone mixing ratios. The increased variability in ozone over land was a product of titration by fresh surface emissions of NO via rapid upward transport in thermals, a hypothesis supported by the observed vertical wind speed component. Fast boundary layer mixing over land was further illustrated by a uniform distribution in reactive alkenes. A comparison between aircraft and surface O(3) UK AUN (Automatic Urban Network) measurements showed good agreement with the inland site, Sibton, but marked differences with the coastal monitoring site at Weybourne, potentially due to gradients established by ocean deposition in stably stratified marine air.

Air Pollutants↗

The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: a comparison of serum, synovial fluid, albumin, EDTA, and water.

Physical wear of orthopedic implants is inevitable. CoCr alloy samples, typically used in joint reconstruction, corrode rapidly after removal of the protective oxide layer. The behavior of CoCr pellets immersed in human serum, foetal bovine serum (FBS), synovial fluid, albumin in phosphate-buffered saline (PBS), EDTA in PBS, and water were studied using X-ray Photoelectron Spectroscopy (XPS) and Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS). The difference in the corrosive nature of human serum, water, albumin in PBS and synovial fluid after 5 days of immersion was highlighted by the oxide layer, which was respectively 15, 3.5, 1.5, and 1.5 nm thick. The thickness of an additional calcium phosphate deposit from human serum and synovial fluid was 40 and 2 nm, respectively. Co and Cr ions migrated from the bulk metal surface and were trapped in this deposit by the phosphate anion. This may account for the composition of wear debris from CoCr orthopedic implants, which is known to consist predominantly of hydroxy-phosphate compounds. Known components of synovial fluid including proteoglycans, pyrophosphates, phospholipids, lubricin, and superficial zone protein (SZP), have been identified as possible causes for the lack of significant calcium phosphate deposition in this environment. Circulation of these compounds around the whole implant may inhibit calcium phosphate deposition.

Albumins↗

Measurement and modelling of air pollution and atmospheric chemistry in the U.K. West Midlands conurbation: overview of the PUMA Consortium project.

The PUMA (Pollution of the Urban Midlands Atmosphere) Consortium project involved intensive measurement campaigns in the Summer of 1999 and Winter of 1999/2000, respectively, in which a wide variety of air pollutants were measured in the UK West Midlands conurbation including detailed speciation of VOCs and major component analysis of aerosol. Measurements of the OH and HO2 free radicals by the FAGE technique demonstrated that winter concentrations of OH were approximately half of those measured during the summer despite a factor of 15 reduction in production through the photolysis of ozone. Detailed box modelling of the fast reaction chemistry revealed the decomposition of Criegee intermediates formed from ozone-alkene reactions to be responsible for the majority of the formation of hydroxyl in both the summer and winter campaigns, in contrast to earlier rural measurements in which ozone photolysis was predominant. The main sinks for hydroxyl are reactions with NO2, alkenes and oxygenates. Concentrations of the more stable hydrocarbons were found to be relatively invariant across the conurbation, but the impacts of photochemistry were evident through analyses of formaldehyde which showed the majority to be photochemical in origin as opposed to emitted from road traffic. Measurements on the upwind and downwind boundaries of the conurbation revealed substantial enhancements in NOx as a result of emissions within the conurbation, especially during westerly winds which carried relatively clean air. Using calcium as a tracer for crustal particles, it proved possible to reconstruct aerosol mass from the major chemical components with a fairly high degree of success. The organic to elemental carbon ratios showed a far greater influence of photochemistry in summer than winter, presumably resulting mainly from the greater availability of biogenic precursors during the summer campaign. Two urban airshed models were developed and applied to the conurbation, one Eulerian, the other Lagrangian. Both were able to give a good simulation of concentrations of both primary and secondary pollutants at urban background locations.

Acetone↗

The effects of calcium phosphate deposition upon corrosion of CoCr alloys and the potential for implant failure.

Physical wear of orthopedic implants is inevitable. CoCr metal samples, typically used in joint reconstruction, corrode rapidly after removal of the protective oxide layer. The behavior of CoCr pellets immersed in human serum, fetal bovine serum (FBS), synovial fluid, and water were studied using time-of-flight secondary ion mass spectroscopy (ToF-SIMS). The differences in the corrosive nature of human serum, FBS, synovial fluid, and water after 5 days immersion were highlighted by the oxide/hydroxide layer, which was, respectively, 25, 10, 1.5, and 3-3.5 nm thick. The thickness of calcium phosphate deposit from human serum, FBS, and synovial fluid was, respectively, 30, 20, and 2 nm. Co and Cr ions migrated from the bulk metal surface and were trapped in the serum deposits, where chromium existed as oxides, hydroxides, and phosphates, whereas the cobalt chemistry was dominated only by phosphates and hydroxides. This may account for the composition of wear debris from CoCr orthopedic implants, which are predominantly hydroxyphosphate compounds. From the literature, proteoglycans, pyrophosphates, phospholipids, lubricin, and superficial zone protein (SZP) have been identified as possible causes for the insignificant deposit of calcium phosphate from synovial fluid. Circulation of these compounds around the whole implant may inhibit calcium phosphate deposition and therefore contribute to osteolysis.

Animals↗

Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants.

The corrosion and dissolution of high- and low-carbon CoCrMo alloys, as used in orthopedic joint replacements, were studied by immersing samples in phosphate-buffered saline (PBS), water, and synovial fluid at 37 degrees C for up to 35 days. Bulk properties were analyzed with a fine ion beam microscope. Surface analyses by X-ray photoelectron spectroscopy and Auger electron spectroscopy showed surprisingly that synovial fluid produced a thin oxide/hydroxide layer. Release of ions into solution from the alloy also followed an unexpected pattern where synovial fluid, of all the samples, had the highest Cr concentration but the lowest Co concentration. The presence of carbide inclusions in the alloy did not affect the corrosion or the dissolution mechanisms, although the carbides were a significant feature on the metal surface. Only one mechanism was recognized as controlling the thickness of the oxide/hydroxide interface. The analysis of the dissolved metal showed two mechanisms at work: (1) a protein film caused ligand-induced dissolution, increasing the Cr concentration in synovial fluid, and was explained by the equilibrium constants; (2) corrosion at the interface increased the Co in PBS. The effect of prepassivating the samples (ASTM F-86-01) did not always have the desired effect of reducing dissolution. The release of Cr into PBS increased after prepassivation. The metal-synovial fluid interface did not contain calcium phosphate as a deposit, typically found where samples are exposed to calcium rich bodily fluids.

Biocompatible Materials↗

Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty.

Previous research has shown an increase in chromosomal aberrations in patients with worn implants. The type of aberration depended on the type of metal alloy in the prosthesis. We have investigated the metal-specific difference in the level of DNA damage (DNA stand breaks and alkali labile sites) induced by culturing human fibroblasts in synovial fluid retrieved at revision arthroplasty. All six samples from revision cobalt-chromium metal-on-metal and four of six samples from cobalt-chromium metal-on-polyethylene prostheses caused DNA damage. By contrast, none of six samples from revision stainless-steel metal-on-polyethylene prostheses caused significant damage. Samples of cobalt-chromium alloy left to corrode in phosphate-buffered saline also caused DNA damage and this depended on a synergistic effect between the cobalt and chromium ions. Our results further emphasise that epidemiological studies of orthopaedic implants should take account of the type of metal alloy used.

Aged↗

Two high-speed, portable GC systems designed for the measurement of non-methane hydrocarbons and PAN: results from the Jungfraujoch High Altitude Observatory.

Near real-time measurements of light non-methane hydrocarbons (NMHCs) and peroxyacetyl nitrate (PAN) have been performed in the free troposphere using two fast gas chromatography (GC) instruments designed for use on aircraft. A GC-helium ionisation detector (HID) system measured 15 C(2)-C(5) hydrocarbons with 5 min time resolution and a dual channel GC-Electron Capture Detector (ECD) measured PAN with 90 s resolution. Both instruments had low parts per trillion by volume (pptV) detection limits and ran continuously at the remote Jungfraujoch (JFJ) research station in the Swiss Alps (46.55[degree]N, 7.98[degree]E), 3580 m above mean sea level (AMSL), during February/March 2003. Carbon monoxide, ozone, nitrogen oxide and nitrogen dioxide and all odd nitrogen species (NO(y)) were also measured continuously. Hydrocarbons and CO were strongly correlated in all air-masses whilst PAN exhibited both positive and negative correlations with respect to O(3), dependent on age and origin of the air-mass sampled. PAN was found to contribute [similar]20% to the NO(y) sampled on average. The experiment, as well as providing interesting datasets from this remote location, also demonstrated that when optimised, GC techniques have the potential to measure at a time resolution significantly greater than is traditionally considered, with high sensitivity and low uncertainty.

Air Pollutants↗

Measurements of C6-C8 hydrocarbons at a UK rural site during January 1999. Site evaluation and correlations between species.

Ambient concentrations of C6-C8 aromatic hydrocarbons and n-heptane, determined by gas chromatography with flame ionisation detection, are presented from a winter campaign during January 1999 at a rural site near Leeds. Absolute concentrations are significantly lower than those obtained from the only designated UK rural site (Harwell) in the automated UK hydrocarbon network. Both absolute and relative concentrations of hydrocarbons measured at the site have been interpreted in terms of the arriving back-trajectories. The site is subject to two main airflows during the winter months; relatively polluted air from the southwest and much cleaner air from the northwest. Ratios of hydrocarbon concentrations show evidence of significant chemical processing consistent with chemical removal by OH. Uncertainties in the ages of the trajectories prevent a reliable estimation of the average OH concentration over the trajectory. The dependence of the variance of the hydrocarbon concentrations with their lifetime with respect to removal by OH does not show the expected behaviour.

Air Pollutants↗

A note on the emission of nitrogen oxides from silage in opened bunker silos.

The evolution of NOx from grass and maize silages was measured using chemiluminescence in samples kept in airtight containers, in the silos and in a 750 kg mass removed to a mixer waggon. Measurements were made on the grass and maize silos in two consecutive years. The results show that there is continuous evolution of NOx after silos have been opened and that high concentrations persist in the mass which are rapidly released on agitation at the feed-out. The maximum recorded concentrations of NO and NO2 were 1985 and 152 ppbv respectively. These values are orders of magnitude greater than for rural background levels and exceed the maximum hourly exposure of 50 ppbv for NO2 recommended by the UK expert panel for quality standards.

Agriculture↗

Simultaneous monitoring of atmospheric methane and speciated non-methane hydrocarbon concentrations using Peltier effect sub-ambient pre-concentration and gas chromatography.

Sub-ambient trapping, used to pre-concentrate atmospheric samples for non-methane hydrocarbon (NMHC) analysis by gas chromatography, can also be used to measure ambient methane concentrations. Above a sample volume of 40 ml, a dynamic equilibrium is established between ambient and trapped methane allowing for simultaneous quantitative determinations of methane and NMHC. The temperature stability of the trap is critical for quantitative methane analysis and this can be achieved by Peltier effect cooling. Simultaneous measurements of methane and NMHC reduce the equipment required for field trips and can ease the interpretation and modelling of atmospheric data. The feasibility for deployment of the system in remote locations was demonstrated by running the apparatus virtually unattended for a 5-day period. The correlations between the concentrations of methane, ethane and ethene measured during this period are discussed.

Air Pollutants↗

Susceptibility of anaerobic bacteria to beta-lactam antibiotics and beta-lactamase production.

We examined the susceptibility of various anaerobes to four beta-lactamase susceptible (ampicillin, amoxycillin, cyclacillin, and penicillin G) and two beta-lactamase resistant (moxalactam, and N-F-thienamycin) beta-lactam antibiotics and measured beta-lactamase production. Members of the Bacteroides groups were most resistant to the six antibiotics. N-F-thienamycin was the most effective antimicrobial agent against all the test strains, moxalactam the next most effective, and penicillin G the least. Beta-lactamase production was mainly confined to Bacteroides species. Cephalosporinase was the most common beta-lactamase produced; penicillinase was detected less often. About two thirds of the penicillin-resistant isolates produced cephalosporinase. N-F-thienamycin and moxalactam were the most active agents against those anaerobes that were resistant to many beta-lactam antibiotics.

Amoxicillin↗

Single-dose cefaclor therapy of urinary tract infection. Evaluation of antibody-coated bacteria test and C-reactive protein assay as predictors of cure.

The efficacy of single-dose (cefaclor, 2 g orally) and multidose (cefaclor, 250 mg orally three times a day for 10 days) antibiotic regimens in the therapy of acute uncomplicated urinary tract infections (UTI) in nonpregnant women were compared. The patient's clinical status and results of urine cultures were compared in retrospect with the results of the antibody-coated bacteria (ACB) test and C-reactive protein (CRP) test in order to determine if either test would predict the patient's response. Overall, 10 of 30 patients (33 percent) and 18 of 22 patients (81 percent) given single doses and multidoses, respectively, had negative urine cultures four weeks after completion of therapy. A negative urine culture at four weeks correlated with a negative ACB test utilizing the less inclusive criteria for negativity (less than 5 bacteria with fluorescence in 5 minutes of search) but not with a negative ACB test utilizing the more inclusive criteria (less than 10 percent bacteria with fluorescence) or with a negative CRP test. The cure rate in the ACB-negative single-dose group (7 of 9 patients) utilizing the less inclusive criteria for negativity was similar to the cure rate in the ACB-negative multidose group (8 of 10 patients). This study suggests that the ACB test, if properly standardized, might permit identification of a population of patients with UTI who would respond to single-dose cefaclor therapy.

Adult↗

The treatment of serious anaerobic infections.

Thirty-one adult patients with infections due to anaerobic bacteria were treated with cefamandole. Bacteroides fragilis group (17) and Bacteroides melaninogenicus (13) were the most frequent anaerobes isolated. Duration of therapy varied from 2 to 49 days. Results were judged satisfactory in 26 cases, and unsatisfactory in 1 case. Four cases could not be evaluated. Adverse reactions occurred in 16 patients and included positive direct Coomb's test without hemolysis, transient liver function abnormalities, phlebitis, reversible neutropenia, fever, eosinophilia, and toxic epidermal necrolysis. The more significant reactions were associated with prolonged therapy. None was lethal. These data suggest that cefamandole is effective in treatment of most anaerobic infections.

Aerobiosis↗