Search PubMed⌕ Search

Biomedical subjects

A C Jackson

Publications and source records attributed to A C Jackson.

At least 91 records · Page 5Linked to original sources

Pathogenesis of experimental rabies in mice: an immunohistochemical study.

The spread of rabies virus in the central nervous system of mice was examined after hindlimb footpad and intracerebral inoculation of the CVS strain of fixed rabies virus. All mice developed paralytic rabies. After intracerebral inoculation there was early simultaneous infection of neurons in the cerebral cortex and pyramidal neurons of the hippocampus, and later there was spread to the cerebellum. After high-dose intracerebral inoculation there was early infection in ependymal cells lining the lateral ventricles and neurons adjacent to the central canal of the spinal cord, suggesting that rabies virus entry into the CNS occurs, at least in part, by a cerebrospinal fluid pathway. The sequence of involvement was different after hindlimb footpad inoculation. Infection became established in the cerebellum on day 5, in the cerebral cortex on day 6, and in the hippocampus on day 8. CA3 was initially affected, CA1 became infected 2 days later, and there was much less involvement of the dentate gyrus. Hippocampal infection occurred late relative to the rest of the brain after peripheral inoculation, but not after intracerebral inoculation. The hippocampus is not a good location for the detection of early brain infection after peripheral inoculation, although it may be involved when a natural rabies vector has the ability to transmit infection. These findings also raise questions about the mechanisms for the limbic dysfunction observed in clinical rabies.

Animals↗

Detection of rabies virus RNA in the central nervous system of experimentally infected mice using in situ hybridization with RNA probes.

Rabies virus is usually demonstrated in human or animal tissues using antigen-detection or viral isolation techniques. Rabies virus RNA can be demonstrated in paraffin-embedded tissues using in situ hybridization. Negative (-) sense 35S- and 3H-labeled RNA probes, specific for rabies virus nucleocapsid protein mRNA, were used for the detection of rabies virus RNA in the nervous system of mice experimentally infected with fixed and street strains of rabies virus. In situ hybridization signals were compared with rabies virus antigen demonstrated with immunoperoxidase staining. Rabies virus RNA and antigen were also demonstrated in the same neurons using a double-labeling technique. In situ hybridization has potential applications as a diagnostic test for rabies and in studies of rabies pathogenesis.

Animals↗

Myelopathy: an unusual presentation of toxoplasmosis.

Central nervous system toxoplasmosis is a well known disease of immunocompromised patients. Neuropathologic examinations have only rarely demonstrated spinal cord involvement. This report describes a fatal case of toxoplasmosis that presented with a subacute myelopathy. Toxoplasmosis should be considered in immuno-compromised patients, including patients with the acquired immune deficiency syndrome, that develop intramedullary lesions of the spinal cord.

Autoimmune Diseases↗

High frequency jet ventilation in horses: an experimental study.

High frequency jet ventilation (HFJV) is a recently developed mode of ventilation that delivers small tidal volumes at frequencies greater than 60 cycles per min via an injection catheter to the animal's airway. The construction of a high frequency jet ventilator suitable for use in adult horses is described. The effectiveness of this ventilator in maintaining normal arterial blood-gas tension was evaluated in five healthy adult horses. The horses were anaesthetised with intravenous acetylpromazine, guaifenesin, and thiamylal, positioned in lateral recumbency and baseline measurements were made during spontaneous ventilation. The horses were then paralysed with succinylcholine and ventilated for at least 20 mins with HFJV. Air was delivered from the ventilator to the animal by a polyethylene tube. The tip of this tube remained within and approximately 30 cm from the cuffed end of a standard 30 mm internal diameter large animal orotracheal tube. Frequency of flow interruption was 3 Hz with a constant source pressure of 275 kPa and an inspiratory to expiratory ratio of approximately 1:2.6. Gas delivery to the horse, as estimated with a resonator system was approximately 2 litres/breath. During HFJV, arterial carbon dioxide tension was significantly reduced and arterial oxygen tension significantly increased above measurements made when the horses were spontaneously breathing air.

Animals↗

Acoustic rhinometry: evaluation of nasal cavity geometry by acoustic reflection.

To study the geometry of the nasal cavity we applied an acoustic method (J. Appl. Physiol. 43: 523-536, 1977) providing an estimate of cross-sectional area as a function of distance. Acoustic areas in a model constructed from a human nasal cast, in the nasal cavity of a cadaver and in 10 normal subjects and two patients with well-defined afflictions of the nasal cavity, were compared with similar areas obtained by computerized tomography (CT) scans, a specially developed water displacement method, and anterior rhinomanometry. We found a coefficient of variation of the areas of less than 2% by the acoustic method compared with 15% for the rhinomanometric measurements. Acoustic areas correlated highly to similar areas obtained by CT scanning (r = 0.94) and by water displacement (r = 0.96). In two patients the acoustic method accurately outlined, respectively, a tumor in the nose and a septum deviation. It is concluded that this method provides an accurate method for measuring the geometry of the nasal cavity. It is easy to perform and is potentially useful for investigation of physiological and pathological changes in the nose.

Acoustics↗

Density dependence of respiratory system impedances between 5 and 320 Hz in humans.

For respiratory system impedance (Zrs), the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956) suggests three resonant frequencies (f1,f2,f3), where f1 is the result of the sum of tissue and airway inertances and tissue compliance and f2 is the result of alveolar gas compression compliance (Cg) and tissue inertance (Iti). Three such resonant frequencies have been reported in humans. However, the parameter estimates resulting from fitting this model to the data suggested that f2 and f3 were not associated with Cg and Iti but with airway acoustic properties. In the present study, we measured Zrs between 5 and 320 Hz in 10 healthy adult humans breathing room air or 80% He-20% O2 (HeO2) to gain insight as to whether airway or tissue properties are responsible for the f2 and f3. When the subjects breathed room air, f2 occurred at 170 +/- 16 (SD) Hz, and when they breathed HeO2 it occurred at 240 +/- 24 Hz. If this resonance were due to Cg and Iti it should not have been affected to this extent by the breathing of HeO2. We thus conclude that f2 is not due to tissue elements but that it is an airway acoustic resonance. Furthermore, application of the six-element model to analyze Zrs data at these frequencies is inappropriate, and models incorporating the airway acoustic properties should be used. One such model is based on the concept of equivalent length, which is defined as the length of an open-ended, cylindrical tube that has the same fundamental acoustic resonant frequency.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Molecular basis of Sindbis virus neurovirulence in mice.

We examined a variety of strains of Sindbis virus for the genetic changes responsible for differences in neurovirulence in mice. SV1A (a low passage of the AR339 strain of Sindbis virus), a neuroadapted Sindbis virus (NSV), and two laboratory strains of Sindbis virus (HRSP and Toto1101) were examined. NSV causes severe encephalomyelitis with hind-limb paralysis and high mortality after intracerebral inoculation in weanling mice. In contrast, SV1A causes only mild, nonfatal disease in weanling mice; however, in suckling mice, SV1A causes a fatal encephalomyelitis after either intracerebral or subcutaneous inoculation. The two laboratory strains used have a greatly reduced neurovirulence for suckling mice and are avirulent for weanling mice. The nucleotide sequences and encoded amino acid sequences of the structural glycoproteins of these four strains were compared. Hybrid genomes were constructed by replacing restriction fragments in a full-length cDNA clone of Sindbis virus, from which infectious RNA can be transcribed in vitro, with fragments from cDNA clones of the various strains. These recombinant viruses allowed us to test the importance of each amino acid difference between the various strains for neurovirulence in weanling and suckling mice. Glycoproteins E2 and E1 were of paramount importance for neurovirulence in adult mice. Recombinant viruses containing the nonstructural protein region and the capsid protein region from an avirulent strain and the E1 and E2 glycoprotein regions from NSV were virulent, although they were less virulent than NSV. Furthermore, changes in either E2 (His-55 in NSV to Gln in SV1A) or E1 (Ala-72 in NSV to Val in SV1A and Asp-313 in NSV to Gly in SV1A) reduced virulence. For virulence in suckling mice, we found that a number of changes in E2 and E1 can lead to decreased virulence and that in fact, a gradient of virulence exists.

Age Factors↗

Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations.

Recent studies on respiratory impedance (Zrs) have predicted that at frequencies greater than 64 Hz a second resonance will occur. Furthermore, if one intends to fit a model more complicated than the simple series combination of a resistance, inertance, and compliance to Zrs data, the only way to ensure statistically reliable parameter estimates is to include data surrounding this second resonance. An additional question, however, is whether the resulting parameters are physiologically meaningful. We obtained input impedance data from eight healthy adult humans using discrete frequency forced oscillations from 4 to 200 Hz. Three resonant frequencies were seen: 8 +/- 2, 151 +/- 10, and 182 +/- 16 Hz. A seven-parameter lumped element model provided an excellent fit to the data in all subjects. This model consists of an airway resistance (Raw), which is linearly dependent on frequency, and airway inertance separated from a tissue resistance, inertance, and compliance by a shunt compliance (Cg) thought to represent gas compressibility. Model estimates of Raw and Cg were compared with those suggested by measurement of Raw and thoracic gas volume using a plethysmograph. In all subjects the model Raw and Cg were significantly lower than and not correlated with the corresponding plethysmographic measurement. We hypothesize that the statistically reliable but physiologically inconsistent parameters are a consequence of the distorting influence of airway wall compliance and/or airway quarter-wave resonance. Such factors are not inherent to the seven-parameter model.

Adult↗

Basis of neurovirulence in Sindbis virus encephalomyelitis of mice.

Neuroadapted Sindbis virus (NSV) was selected by serial passage of wild-type Sindbis virus (SV) in mouse brain. After intracerebral inoculation of weanling mice, NSV causes a severe encephalomyelitis with hindlimb paralysis and high mortality; SV causes nonfatal mild disease. In order to determine the biologic basis of neurovirulence in vivo, these viral infections have been compared by using infectivity assays, light and electron microscopy, in situ hybridization, immunohistochemistry, and double-labeling for neural cell markers and viral RNA. More infectious virus is present in the central nervous system during NSV than during SV infection. After intracerebral inoculation, both viruses enter the central nervous system via the ependyma and spread to gray matter areas, including the ventral horns of the spinal cord. Their cellular targets are not different, and neuronal infection is prominent. NSV infects more neurons, and causes more severe injury than SV. In NSV infection, there is marked swelling of lumbar and thoracic neurons and their processes in the ventral horns. Relatively mild changes are detected in SV infection only by electron microscopy. Neuroadaptation likely occurs by increasing the efficiency of viral replication in neurons, rather than by a fundamental change in the cellular tropism or the topography of the infection in the central nervous system.

Animals↗

Reliability of parameter estimates from models applied to respiratory impedance data.

Many previous studies have fit lumped parameter models to respiratory input (Zin) and transfer (Ztr) impedance data. For frequency ranges higher than 4-32 Hz, a six-element model may be required in which an airway branch (with a resistance and inertance) is separated from a tissue branch (with a resistance, inertance, and compliance) by a shunt compliance. A sensitivity analysis is applied to predict the effects of frequency range on the accuracy of parameter estimates in this model obtained from Zin or Ztr data. Using a parameter set estimated from experimental data between 4 and 64 Hz in dogs, both Zin and Ztr were simulated from 4 to 200 Hz. Impedance sensitivity to each parameter was also calculated over this frequency range. The simulation predicted that for Zin a second resonance occurs near 80 Hz and that the impedance is considerably more sensitive to several of the parameters at frequencies surrounding this resonance than at any other frequencies. Also, unless data is obtained at very high frequencies (where the model is suspect), Zin data provides more accurate estimates than Ztr data. After adding random noise to the simulated Zin data, we attempted to extract the original parameters by using a nonlinear regression applied to three frequency ranges: 4-32, 4-64, and 4-110 Hz. Estimated parameters were substantially incorrect when using only 4- to 32-Hz or 4- to 64-Hz data, but nearly correct when fitting 4- to 110-Hz data. These results indicate that respiratory system parameters can be more accurately extracted from Zin than Ztr, and to make physiological inferences from parameter estimates based on Zin impedance data in dogs, the data must include frequencies surrounding the second resonance.

Airway Resistance↗

Modeling of respiratory system impedances in dogs.

Mechanical impedances between 4 and 64 Hz of the respiratory system in dogs have been reported (A.C. Jackson et al. J. Appl. Physiol. 57: 34-39, 1984) previously by this laboratory. It was observed that resistance (the real part of impedance) decreased slightly with frequency between 4 and 22 Hz then increased considerably with frequency above 22 Hz. In the current study, these impedance data were analyzed using nonlinear regression analysis incorporating several different lumped linear element models. The five-element model of Eyles and Pimmel (IEEE Trans. Biomed. Eng. 28: 313-317, 1981) could only fit data where resistance decreased with frequency. However, when the model was applied to these data the returned parameter estimates were not physiologically realistic. Over the entire frequency range, a significantly improved fit was obtained with the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956), since it could follow the predominate frequency-dependent characteristic that was the increase in resistance. The resulting parameter estimates suggested that the shunt compliance represents alveolar gas compressibility, the central branch represents airways, and the peripheral branch represents lung and chest wall tissues. This six-element model could not fit, with the same set of parameter values, both the frequency-dependent decrease in Rrs and the frequency-dependent increase in resistance. A nine-element model recently proposed by Peslin et al. (J. Appl. Physiol. 39: 523-534, 1975) was capable of fitting both the frequency-dependent decrease and the frequency-dependent increase in resistance. However, the data only between 4 and 64 Hz was not sufficient to consistently determine unique values for all nine parameters.

Airway Resistance↗

Inverse modeling of dog airway and respiratory system impedances.

Mechanical parameters of the respiratory system are often estimated from respiratory impedances using lumped-element inverse models. One such six-element model is composed of an airway branch [with a resistance (Raw) and inertance (Iaw)] separated from a tissue branch [with a resistance (Rt), inertance (It), and compliance (Ct)] by a shunt compliance representing alveolar gas compression (Cg). Even though the airways are known to have frequency-dependent resistance and inertance, these inverse models have been composed of linear frequency-independent elements. In this study we investigated the use of inverse models where the airway branch was represented by a frequency-independent Raw and Iaw, a Raw that is linearly related to frequency and an Iaw that is independent of frequency, and a system of identical parallel tubes the impedance of which was computed from the tube radius and length. These inverse models were used to analyze airway and respiratory impedances between 2 and 1,024 Hz that were predicted from an anatomically detailed forward model. The forward model represented the airways by an asymmetrically branched network with a terminal impedance representative of known Cg, Rt, It, and Ct. For respiratory impedances between 2 and 128 Hz, all models fit the data reasonably well, and reasonably accurate estimates of Cg, Rt, It, and Ct were extracted from these data. For data above 200 Hz, however, only the multiple-tube model accurately fitted respiratory impedances (Zrs). This model fitted the Zrs data best when composed of 27 tubes, each having a radius of 0.148 cm and a length of 16.5 cm.

Animals↗

The pathogenesis of spinal cord involvement in the encephalomyelitis of mice caused by neuroadapted Sindbis virus infection.

Weanling mice develop an acute encephalomyelitis with high mortality after intracerebral inoculation of neuroadapted Sindbis virus. The mice develop kyphoscoliosis and hindlimb paralysis. Immunohistochemical and in situ hybridization studies have demonstrated virus in the gray matter of the brain and spinal cord. Ventral horn cells are prominently infected, providing an anatomical basis for the clinical poliomyelitis. A novel route of spread of inoculated virus within the central nervous system has been found. The virus enters the ventricular system, and then travels caudally in the central canal of the spinal cord where ependymal cells are infected. The virus subsequently spreads into the gray matter. The distribution of virus in the spinal cord is likely dependent both on variations in the susceptibility of neural cells and on this route of entry and subsequent spread.

Animals↗

Linear-lumped-parameter modeling of pulmonary impedance in monkeys.

Pulmonary impedance, ZL, measured from 2 to 32 Hz in anesthetized, intubated and paralyzed bonnet monkeys (Macaca radiata) was fitted to a variety of linear-lumped parameter mechanical networks. Parameter values for each network were obtained by minimizing the average of the percent distance, Dr, between the computed network impedance and measured ZL at all frequencies. Measured resistance, RL, decreased from 2 to 8 Hz and increased from 8 to 32 Hz indicating that a single series resistance-inertance-compliance (RIC) network was not optimal (Dr approximately 19%). Networks consisting of two series RIC pathways in parallel resulted in a lower Dr (approximately 14%), but parameter values were difficult to interpret. Despite not modeling the decrease in RL with frequency below 8 Hz, an airway wall compliance, Caw, network in which the airways were separated into central and peripheral components resulted in an even lower Dr (approximately 11%). In addition, parameter values were easy to interpret, consistent among our "normal" monkeys and changed consistently and explainably with change in lung mechanics induced by decrease in lung volume. We conclude that networks containing both parallel pathways and Caw are necessary to model ZL over the entire frequency range (2-32 Hz), the effect of Caw is an important determinant of ZL above 8 Hz, and a six-parameter Caw network with the ratio of Caw to parenchymal compliance, Cp, fixed may prove useful in interpreting changes in ZL induced by alterations in lung mechanics in monkeys.

Airway Resistance↗

Neurologic disorders associated with mitral valve prolapse.

Mitral valve prolapse has been reported to be associated with a variety of neurologic disorders, including cerebral ischemia, transient global amnesia, migraine, autonomic dysfunction, and psychiatric disease. The evidence supporting these associations and possible pathogenetic mechanisms are discussed. Some neurologic disorders may be direct complications of mitral valve prolapse, while others may occur as part of an underlying genetic defect or common link.

Amnesia↗

Effect of lung volume on pulmonary mechanics in guinea pigs.

The lung volume (VL) dependence of several dynamic pulmonary mechanical properties of the guinea pig lung were determined over the range of the vital capacity (10-100% VC) with the vagi intact and sectioned. We found dynamic compliance to be strongly VL dependent, decreasing as much as 85% between functional residual capacity (FRC) and total lung capacity (TLC). Below FRC, dynamic compliance either remained unchanged or decreased, depending upon the technique used in its measurement. Pulmonary resistance (RL) decreased monotonically with increasing VL, whereas pulmonary conductance was linearly related to VL. Conductance was much less sensitive to VL than compliance, increasing only 28% between FRC and TLC. The sensitivity of pulmonary conductance to VL was substantially increased by subtracting the resistance of the tracheal cannula from RL. Specific pulmonary conductance was not independent of VL but decreased approximately 45% over the range of the VC. Pulmonary inertance was found to be unaffected by VL. Extrapolation from these data indicate that small differences in FRC, which might be expected within and between studies relying on pulmonary mechanical measurements, would most strongly affect compliance estimates and only moderately alter resistance estimates. It also indicates that the use of specific pulmonary conductance does not remove VL as an independent variable.

Airway Resistance↗