Search PubMed⌕ Search

Biomedical subjects

A C Groenewegen

Publications and source records attributed to A C Groenewegen.

5 recordsLinked to original sources

High-speed photodamage cell selection using a frequency-doubled argon ion laser.

A flow cytometer was developed for the high-speed "sorting" of desired cells by selectively irradiating (zapping) the undesired cells from a population. After previous efforts to photoinactivate cells with photosensitizers had failed, it was decided to exploit the photosensitivity of the cell's DNA at 257 nm. It was shown that a 257 nm laser output power of 20-100 mW was sufficient to induce a 4.5 log cell kill after the cells were processed through a focused 257 nm laser beam. Experiments proved that the photodamage flow cytometer (ZAPPER) could selectively photoinactivate cells at rates over 22,000 events/s, and selection purities ranged from 81% to 100%. The yields of the desired cells depended on the selection mode. In the Enrichment mode, the zap laser was not aimed at the jet, and only undesired cells were exposed to a brief ultraviolet (UV) pulse after modulation of the UV laser beam. The yields of desired cells ranged from 95% to 105%. In the Purge mode, the zap laser beam was aimed onto the jet, and only desired cells were allowed to pass after deflection of the UV laser beam; the yields of desired cells ranged from 12% to 52%. The cause of the reduced yields in the PURGE mode was traced to the fact that the Electro-Optic Modulator was used to modulate the zap laser proved too slow for the intended application. The lifetime of the frequency-doubling crystal used for the generation of the 257 nm beam was found to be limited to several days.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Classmode: a new data format for real-time multiparameter data analysis and data compression.

A new data acquisition and analysis format (classmode) was developed that allows real-time data classification in a flow cytometer. In our cytometer, detected events were classified in real time by their presence or absence in a set of look-up tables (LUT). A modification of the cytometer hardware allows the exclusive transfer of the LUT data to the acquisition/storage computer. Using a combination of 8 LUTs, the analyzed events can be classified into 256 subpopulations. Real-time data classification results in an increased data transfer rate and a significant compression of the data.

Cells, Cultured↗

Coincidence in high-speed flow cytometry: models and measurements.

In flow cytometry, the coincident arrival of particles becomes a major problem when high sample rates are required. For the development of our high-speed photodamage flow cytometer (ZAPPER), it was of importance to understand the behavior of cells at flow rates of around 50,000-250,000 event/s. We developed and compared two models that describe the relation between the real cell rate and the detectable single cell rate. Both the Computer Simulation model and the Input/Output Device model show distinct optima for the cell rate. The models were compared to measurements performed on the ZAPPER-prototype. Fits of the two models to the experimental data were excellent for cycle times of 4 and 15 microseconds and acceptable for a 2 microseconds cycle time. A third model (Mercer WB, Rev. Sci. Instr. 37:1515-1521,1966) could be fitted to the experimental data, after the proportionality constant k was adapted to the experimental data. At a yield of detectable single cells of 70%, the maximum cell rates are 180,000, 100,000, and 40,000 cells/s for cycle times of 2, 4, and 15 microseconds, respectively. Based on these results we can now select an optimal cell rate for analysis and sorting based on criteria such as accepted cell loss. In addition, the advantages of reducing the cycle time can now be evaluated with respect to the costs of that modification.

Cell Separation↗

Optical plankton analyser: a flow cytometer for plankton analysis, II: Specifications.

An analysing flow cytometer, the optical plankton analyser (OPA), is presented. The instrument is designed for phytoplankton analysis, having a sensitivity comparable with commercially available flow cytometers, but a significantly extended particle size range. Particles of 500 microns in width and over 1,000 microns in length can be analysed. Sample flow rates of up to 55 microliters/s can be used. Also, the dynamic range of the instrument is significantly increased for particles larger than about 5 microns. The optics, hydraulics, and electronics of the instrument are described, including the best form for a low fluid shear cuvette. The new pulse quantification technique we call digital integration is presented. This technique is essential for the instrument to handle both short and very long particles with a large dynamic range. Test measurements demonstrating particle size range and dynamic range are presented. Dynamic ranges of 10,000 and 100,000 were typically observed, measuring field samples with Microcystis aeruginosa colonies, whereas one sample showed a dynamic range of 10(6). A simple method for interpretation of time of flight (TOF) data in terms of particle morphology is presented. The specifications of the instrument are given.

Electronic Data Processing↗