Removal of eye movement artefacts from single channel recordings of retinal evoked potentials using synchronous dynamical embedding and independent component analysis.

A system is described for the removal of eye movement and blink artefacts from single channel pattern reversal electroretinogram recordings of very poor signal-to-noise ratios. Artefacts are detected and removed by using a blind source separation technique based on the jadeR independent component analysis algorithm. The single channel data are arranged as a series of overlapping time-delayed vectors forming a dynamical embedding matrix. The structure of this matrix is constrained to the phase of the stimulation epoch: the term synchronous dynamical embedding is coined. A novel method using a marker channel with a non-independent synchronous feature is employed to identify the single most relevant source estimation for reconstruction and signal recovery. This method is non-lossy, all underlying signal being recovered. In synthetic datasets of defined noise content and in standardised real data recordings, the performance of this technique is compared to conventional fixed-threshold hard-limit rejection. The most significant relative improvements are achieved when movement and blink artefacts are greatest: no improvement is demonstrable for the random noise only situation.

Artifacts↗

Strength and fatigability of selected muscles in upper limb: assessing muscle imbalance relevant to tennis elbow.

PURPOSE: The aetiology of tennis elbow has remained uncertain for more than a century. To examine muscle imbalance as a possible pathophysiological factor requires a reliable method of assessment. This paper describes the development of such a method and its performance in healthy subjects. We propose a combination of surface and fine-wire EMG of shoulder and forearm muscles and wrist strength measurements as a reliable tool for assessing muscle imbalance relevant to the pathophysiology of tennis elbow. METHODS: Six healthy volunteers participated. EMG data were acquired at 50% maximal voluntary isometric contraction from five forearm muscles during grip and three shoulder muscles during external rotation and abduction, and analysed using normalized median frequency slope as a fatigue index. Wrist extension/flexion strength was measured using a purpose-built dynamometer. RESULTS: Significant negative slope of median frequency was found for all muscles, with good reproducibility, and no significant difference in slope between the different muscles of the shoulder and the wrist. (Amplitude slope showed high variability and was therefore unsuitable for this purpose.) Wrist flexion was 27+/-8% stronger than extension (mean+/-SEM, p=0.006). CONCLUSION: This is a reliable method for measuring muscle fatigue in forearm and shoulder. EMG and wrist strength studies together can be used for assessing and identifying the muscle balance in the wrist-forearm-shoulder chain.

Adult↗

Patient stratification in the management of acute bacterial exacerbation of chronic bronchitis: the role of levofloxacin 750 mg.

This is the first prospective clinical trial in which patients with acute bacterial exacerbation of chronic bronchitis have been stratified by degree of underlying illness. Uncomplicated patients were randomised to levofloxacin 750 mg once daily (q.d.) for 3 days or azithromycin q.d. for 5 days. Complicated patients were randomised to levofloxacin 750 mg q.d. for 5 days or amoxicillin 875 mg/clavulanate 125 mg twice daily for 10 days. Regardless of therapy, complicated patients demonstrated lower clinical and microbiological success than uncomplicated patients. Clinical success for clinically evaluable patients was similar for levofloxacin and azithromycin (93.0 versus 90.1%, respectively), and levofloxacin and amoxicillin/clavulanate (79.2 versus 81.7%, respectively). For microbiologically evaluable patients, clinical response to levofloxacin for 3 days was superior to azithromycin for 5 days (96.3 versus 87.4%, respectively), and levofloxacin for 5 days was similar to amoxicillin/clavulanate for 10 days (81.4 versus 80.9%, respectively). Microbiological eradication was superior for levofloxacin for 3 days compared with azithromycin for 5 days (93.8 versus 82.8%, respectively), and similar for levofloxacin and amoxicillin/clavulanate for 10 days (81.4 versus 79.8%, respectively). In conclusion, levofloxacin 750 mg for 3 days was comparable to azithromycin for 5 days for uncomplicated patients with acute bacterial exacerbation of chronic bronchitis, while 5 days of 750 mg levofloxacin was comparable to 10 days of amoxicillin/clavulanate for complicated acute bacterial exacerbation of chronic bronchitis.

Administration, Oral↗

Neutrophil capture by selectins on endothelial cells exposed to cigarette smoke.

We used a novel perfusion system to expose cultured human umbilical vein endothelial cells (HUVEC) to water-soluble components of cigarette smoke and study subsequent adhesion of flowing neutrophils. Neutrophils did not bind to HUVEC immediately after it had been exposed to cigarette smoke, but many adhered 90-150 min after exposure. The effect was reduced if the exposed medium was made serum-free, but this reduction was partially reversed if low density lipoprotein was added. Treatment of smoke-exposed HUVEC with antibodies against E-selectin or P-selectin reduced adhesion by approximately 50% or 75%, respectively; a combination of both antibodies essentially abolished adhesion. Enzyme-linked immunosorbent assay confirmed that exposure to smoke caused HUVEC to upregulate surface expression of E- and P-selectin. Thus, water-soluble constituent(s) of cigarette smoke cause efficient selectin-mediated capture of flowing neutrophils. This pro-inflammatory response may contribute to pathology associated with smoking, especially in tissues remote from the lung.

Cell Adhesion↗

Hydrodynamic potential-modulated reflectance spectroscopy: theory and experiment.

This article describes the development and application of a new electrochemical methodology based on potential-modulated UV-vis reflectance spectroscopy (PMRS). The device configuration is based upon a thin-layer flow-through channel cell incorporating a platinum working electrode. Reagent solutions are pumped through the cell under well-defined hydrodynamic conditions and electrolyzed at the platinum working electrode. Measurements are presented for linear sweep and fixed dc potentials with a superimposed small amplitude sinusoidal potential perturbation. A UV-vis source is employed to irradiate the electrode region, and the resulting reflected signal is analyzed using a phase sensitive detector. Experimental studies using tris(4-bromophenyl) amine (TBPA) in acetonitrile are presented which quantify the relationship between the absorption spectrum and reflected light intensity as a function of the transport rate, electrolysis reactions, and the modulation frequency of the incident irradiation. The experimental results are analyzed using numerical simulations based on a finite difference strategy. These permit the quantitative prediction of the concentration distribution of reagents within the cell. A fast Fourier transform (FFT) routine was used to analyze the frequency response of the numerically predicted reflectance signal. Excellent agreement was observed between the numerical predictions and experimental observations.

Journal Article↗

Evaluation of contraceptive efficacy and cycle control of a transdermal contraceptive patch vs an oral contraceptive: a randomized controlled trial.

CONTEXT: Oral contraceptive (OC) pills are effective, but poor compliance increases rates of pregnancy during treatment. OBJECTIVE: To compare the contraceptive efficacy, cycle control, compliance, and safety of a transdermal contraceptive patch and an OC. DESIGN: Randomized, open-label, parallel-group trial conducted October 1997 to June 1999. SETTING: Forty-five clinics in the United States and Canada. PARTICIPANTS: A total of 1417 healthy adult women of child-bearing potential. INTERVENTIONS: Participants were randomly assigned to receive a transdermal contraceptive patch (n = 812) vs an OC (n = 605) for 6 or 13 cycles. Patch treatment consisted of application of 3 consecutive 7-day patches followed by 1 patch-free week. MAIN OUTCOME MEASURES: Overall and method-failure Pearl Indexes (number of pregnancies/100 person-years of use) and life-table estimates of the probability of pregnancy were calculated. Cycle control, compliance, patch adhesion, and adverse events were also assessed. RESULTS: Overall and method-failure Pearl Indexes were numerically lower with the patch (1.24 and 0.99, respectively) vs the OC (2.18 and 1.25, respectively); this difference was not statistically significant (P =.57 and.80, respectively). The incidence of breakthrough bleeding and/or spotting was significantly higher only in the first 2 cycles in the patch group, but the incidence of breakthrough bleeding alone was comparable between treatments in all cycles. The mean proportion of participants' cycles with perfect compliance was 88.2% (811 total participants, 5141 total cycles) with the patch and 77.7% (605 total participants, 4134 total cycles) with the OC (P <.001). Only 1.8% (300/16 673) of patches completely detached. Both treatments were similarly well tolerated; however, application site reactions, breast discomfort, and dysmenorrhea were significantly more common in the patch group. CONCLUSION: The contraceptive patch is comparable to a combination OC in contraceptive efficacy and cycle control. Compliance was better with the weekly contraceptive patch than with the OC.

Administration, Cutaneous↗

Comparison of a novel norgestimate/ethinyl estradiol oral contraceptive (Ortho Tri-Cyclen Lo) with the oral contraceptive Loestrin Fe 1/20.

This multicenter study compared the contraceptive efficacy, cycle control, and safety of a new triphasic norgestimate (180/215/250 microg)/ethinyl estradiol 25 microg regimen (Ortho Tri-Cyclen Lo) (n = 1,723) with that of norethindrone acetate 1 mg/ethinyl estradiol 20 microg (Loestrin Fe 1/20) (n = 1,171). Healthy women were treated for up to 13 cycles. Demographics were similar between regimens. Contraceptive efficacy was comparable for Ortho Tri-Cyclen Lo and Loestrin Fe 1/20. The overall and method failure probabilities of pregnancy through 13 cycles were 1.9% and 1.5%, respectively, with Ortho Tri-Cyclen Lo and 2.6% and 2.4%, respectively, with Loestrin Fe 1/20. Breakthrough bleeding and spotting was reported by a significantly lower percentage of participants in the Ortho Tri-Cyclen Lo group compared with the Loestrin Fe 1/20 group. At representative Cycles 1, 3, 6, 9, and 13, breakthrough bleeding and spotting rates were 16.3, 11.5, 10.3, 7.9, and 7.7%, respectively, in the Ortho Tri-Cyclen Lo group and 34.9, 22.9, 22.2, 15.9, and 13.1%, respectively, in the Loestrin Fe 1/20 group. Compliance and safety data were similar for the two regimens.

Administration, Oral↗

Efficacy and safety of a transdermal contraceptive system.

OBJECTIVES: To evaluate the efficacy, cycle control, compliance, and safety of a transdermal contraceptive system that delivers norelgestromin 150 microg and ethinyl estradiol 20 microg daily. METHODS: In this open-label, 73-center study, 1672 healthy, ovulatory, sexually active women received ORTHO EVRA/EVRA for six (n = 1171) or 13 cycles (n = 501). The treatment regimen for each cycle was three consecutive 7-day patches (21 days) followed by 1 patch-free week. RESULTS: The overall and method-failure probabilities of pregnancy through 13 cycles were 0.7% and 0.4%, respectively. The incidence of breakthrough bleeding was low throughout the study. Perfect compliance (21 consecutive days of dosing, followed by a 7-day drug-free interval; no patch could be worn for more than 7 days) was achieved in 90% of subject cycles; only 1.9% of patches detached completely. Adverse events were typical of hormonal contraception, and most were mild-to-moderate in severity and not treatment limiting. The most common adverse events resulting in discontinuation were application site reactions (1.9%), nausea (1.8%), emotional lability (1.5%), headache (1.1%), and breast discomfort (1.0%). CONCLUSIONS: The transdermal contraceptive patch provides effective contraception and cycle control, and is well tolerated. The weekly change schedule for the contraceptive patch is associated with excellent compliance and wearability characteristics.

Administration, Cutaneous↗

Transdermal contraception.

This review summarizes the clinical studies involving the once-weekly Ortho Evra/Evra contraceptive patch. The patch delivers norelgestromin (NGMN), 150 microg, and ethinyl estradiol (EE), 20 microg, daily to the systemic circulation. The contraceptive patch provided ovulation suppression and cycle control similar to that of oral norgestimate 250 microg/EE 35 microg, significantly decreased mean maximum follicular diameter following a 3-day intentional delayed dosing phase when compared with oral levonorgestrel (LNG) 50/75/125 microg/EE 30/40/30 micorg and oral LNG 100 microg/EE 20 microg, and was as effective as oral LNG 50/75/125 microg/EE 30/40/30 microg and oral desogestrel 150 microg/EE 20 microg in altering cervical mucus composition (i.e., creating a scanty, viscous consistency). The contraceptive patch provided efficacy, cycle control, and safety comparable to that seen with oral LNG 50/75/125 microg/EE 30/40/30 microg, but women were able to correctly follow the weekly dosing regimen significantly more often than the daily oral contraceptive dosing regimen. Less than 2% of patches were replaced because of complete detachment in these trials. The patch was not associated with phototoxicity or photoallergy. The contraceptive patch, the only noninvasive, weekly birth control method that a woman can self-administer, will be a valuable addition to current contraceptive options.

Administration, Cutaneous↗

Monocular and binocular depth discrimination thresholds.

BACKGROUND: Measurement of stereoacuity at varying distances, by real or simulated depth stereoacuity tests, is helpful in the evaluation of patients with binocular imbalance or strabismus. Although the cue of binocular disparity underpins stereoacuity tests, there may be variable amounts of other binocular and monocular cues inherent in a stereoacuity test. In such circumstances, a combined monocular and binocular threshold of depth discrimination may be measured--stereoacuity conventionally referring to the situation where binocular disparity giving rise to retinal disparity is the only cue present. A child-friendly variable distance stereoacuity test (VDS) was developed, with a method for determining the binocular depth threshold from the combined monocular and binocular threshold of depth of discrimination (CT). METHODS: Subjects with normal binocular function, reduced binocular function, and apparently absent binocularity were included. To measure the threshold of depth discrimination, subjects were required by means of a hand control to align two electronically controlled spheres at viewing distances of 1, 3, and 6m. Stereoacuity was also measured using the TNO, Frisby, and Titmus stereoacuity tests. BTs were calculated according to the function BT= arctan (1/tan alphaC - 1/tan alphaM)(-1), where alphaC and alphaM are the angles subtended at the nodal points by objects situated at the monocular threshold (alphaM) and the combined monocular-binocular threshold (alphaC) of discrimination. RESULTS: In subjects with good binocularity, BTs were similar to their combined thresholds, whereas subjects with reduced and apparently absent binocularity had binocular thresholds 4 and 10 times higher than their combined thresholds (CT). The VDS binocular thresholds showed significantly higher correlation and agreement with the TNO test and the binocular thresholds of the Frisby and Titmus tests, than the corresponding combined thresholds (p = 0.0019). CONCLUSION: The VDS was found to be an easy to use real depth (distance) stereoacuity test. The method described for calculating the BT provides one simple nonlinear solution for determining the respective contributions of binocular and monocular (MT) depth discrimination to the combined depth threshold.

Adolescent↗

A new capillary viscometer for whole blood viscosimetry.

A new capillary system was developed, incorporating infrared sensors, which allowed the determination of whole blood viscosity over a wide range of shear stresses. Flow conditions were defined by the geometry of the capillary and the sample pressure head. Whole blood was considered to be a power law fluid and a modified Mooney's formula was used for the calculation of the related invariants. The new viscometer proved to be very simple in use, requiring one run, had a short measuring time and utilised a small test sample volume. However it can be used for whole blood viscosity measurements only at medium and high shear stresses.

Blood Viscosity↗

Macrophage--polymer interactions.

One of the most notable and initial indications of the body's response to an implanted material is the inflammatory response, a process which is known to be largely influenced by the activation of macrophages and other cell types. Thus, the magnitude of the inflammatory response can be related to the level of activation of macrophages. As certain well defined morphological changes are known to accompany cell activation, we quantitatively evaluated the cell--substrate interactions, between a range of polymeric materials and isolated macrophages in vitro, using microscopy and image analysis. This enabled us to assess the morphology of the cells, and how the morphology of the macrophages was influenced by changes in time and substrate. This method provided detailed images which were used to evaluate cell-substrate interactions. It was found that, polyurethane (PU) and poly(dimethylsiloxane) (Si) samples displayed a similar pattern in cell behaviour, whilst macrophages placed in contact with polyvinylchloride (PVC) samples continually displayed a more activated morphology with increasing time throughout the test period. As well as providing a detailed analysis of cell-substrate interactions this study also highlighted the advantages of employing an image analysis program for a more comprehensive and reproducible form of assessment of cellular morphology.

Biocompatible Materials↗

The public release of hospital and physician mortality data in Pennsylvania. A case study.

OBJECTIVES: Using the public reports of the Pennsylvania Health Care Cost Containment Council on coronary artery bypass graft surgery for 1990 to 1992 as a case study, the authors assess the sensitivity of results to the choice of data and statistical methodology. METHODS: Using the Council's public-release data, surgical mortality and utilization were reanalyzed by standard linear models, empirical Bayes methods, Monte Carlo simulations, and hierarchical statistical models. RESULTS: Statistical power calculations demonstrate that the annual volume of bypass surgery for many hospitals and for most surgeons is too small for meaningful mortality comparisons. The number of hospitals and physicians designated as mortality "outliers" in the Council's reports results in part from a failure to adjust critical P values for multiple comparisons. Hierarchical statistical models implemented by mixed effects logistic regression, by contrast, can detect true differences in performance without producing false outliers. Mortality analyses are sensitive to the choice of comorbidities used for severity adjustment of a mortality model. Small-area analyses indicate large differences in the rates of bypass surgery across Pennsylvania, with lower population-based rates of surgery associated with higher population-based inpatient mortality. CONCLUSIONS: Analyses of mortality by operative procedure, rather than by patient diagnosis, should consider the potential for selection bias caused by the decision to elect surgery. The clinical and statistical issues of operative mortality are sufficiently complex to merit review by independent experts before public release of hospital and physician performance measures.

Cardiology Service, Hospital↗

Endothelial-borne platelet-activating factor and interleukin-8 rapidly immobilize rolling neutrophils.

The kinetics of the response of integrins to activating signal(s) must be rapid to ensure that rolling neutrophils are localized at the sites of inflammation. From video records, we analyzed the adhesion of individual neutrophils in a flow-based in vitro model of endothelial hypoxia and reoxygenation. There were numerous rolling interactions between flowing neutrophils and P-selectin on human umbilical vein endothelial cells after hypoxia, but 90% lasted for < 1 s, with approximately 30% converted to stationary attachment via beta 2-integrin(s). Interleukin-8 (IL-8) and platelet-activating factor (PAF) were responsible for neutrophil activation in this model [G. E Rainger, A. Fisher, C. Shearman, and G. B. Nash. Am. J. Physiol. 269 (Heart Circ. Physiol. 38): H1398-H1406, 1995]. In the presence of a PAF-receptor antagonist, IL-8 acting alone induced conversion of rolling to stationary adhesion in as little as 80 ms after the initial attachment of a neutrophil, with a median response time of 240 ms. In the presence of a monoclonal antibody that neutralized IL-8 activity, PAF acting alone required a minimum duration of rolling of 560 ms to promote stationary adhesion, with a significantly longer median duration of 720 ms. In a reconstituted model, treatment of endothelial cells with hydrogen peroxide induced short-lived rolling of neutrophils supported by P-selectin. Exogenously added IL-8 and/or PAF bound to the endothelial surface and successfully induced the immobilization of neutrophils. Rapid and distinct kinetics of the conversion to stationary adhesion were observed again for IL-8 or PAF. Thus although endothelial-presented signals differed in their rate of action, neutrophils could be localized within one or two endothelial cell diameters of their initial adhesive contact point.

Cell Adhesion↗

New polyurethane heart valve prosthesis: design, manufacture and evaluation.

In light of the thrombogenicity of mechanical valves and the limited durability of bioprosthetic valves, alternative designs and materials are being considered for prosthetic heart valves. A new tri-leaflet valve, made entirely from polyurethane, has been developed. The valve comprises three thin polyurethane leaflets (approximately 100 microns thick) suspended from the inside of a flexible polyurethane frame. The closed leaflet geometry is elliptical in the radial direction and hyperbolic in the circumferential direction. Valve leaflets are formed and integrated with their support frame in a single dip coating operation. The dipping process consistently gives rise to tolerably uniform leaflet thickness distributions. In hydrodynamic tests, the polyurethane valve exhibits pressure gradients similar to those for a bioprosthetic valve (St Jude Bioimplant), and levels of regurgitation and leakage are considerably less than those for either a bi-leaflet mechanical valve (St Jude Medical) or the bioprosthetic valve. Six out of six consecutively manufactured polyurethane valves have exceeded the equivalent of 10 years function without failure in accelerated fatigue tests. The only failure to date occurred after the equivalent of approximately 12 years cycling, and three valves have reached 527 million cycles (approximately 13 years equivalent). The simplicity of valve manufacture, combined with promising results from in vitro testing, indicate that further evaluation is warranted.

Biocompatible Materials↗

The prognostic significance of serum viral load, codon 215 reverse transcriptase mutation and CD4+ T cells on progression of HIV disease in a double-blind study of thymopentin.

OBJECTIVE: To determine in asymptomatic HIV-infected subjects the prognostic value of virion reverse transcriptase (RT) codon 215 mutation, serum HIV RNA level, CD4+ T-cell count and immune complex dissociated (ICD) p24 level. The retrospective evaluation of thymopentin treatment effect on subjects in high risk groups for progression was a secondary objective. PARTICIPANTS: Zidovudine (ZDV)-experienced asymptomatic HIV-infected subjects (n = 352) who had been enrolled in a 48-week placebo-controlled double-blind trial of thymopentin treatment were studied. METHODS: Post hoc analyses were conducted to determine which subjects at study entry were at greater risk for progression to AIDS-related complex (ARC), AIDS or death, and to determine the effect of treatment on these subjects. Four potential prognostic variables (virion RT codon 215 mutation, circulating HIV virion RNA copies, CD4+ T-cell count, and ICD p24) were evaluated by dichotomizing subjects for each variable based on the median of the observed values. CD4+ T-cell count was evaluated prospectively, whereas frozen samples were evaluated under blinded conditions for the other variables after the study was completed. RESULTS: The presence of the codon 215 mutation [P = 0.044; relative hazard (RH), 2.6], > or = 20,000 HIV RNA copies/ml (P = 0.002; RH, 5.5), and < 350 CD4+ cells 10(6)/l (P = 0.042; RH, 2.2) were prognostic factors, and > or = 30 pg/ml ICD p24 level (P = 0.52; RH, 1.4) was not a prognostic factor in predicting progression. Subjects were prestratified by previous ZDV use (< or = 6 or > 6 months). Across both strata thymopentin delayed treatment progression to ARC, AIDS, or death (P = 0.015; RH, 3.0). This effect was magnified in the ZDV-experienced subjects at greater risk, where thymopentin delayed progression compared to placebo in the presence of the codon 215 mutation (P = 0.007; RH, 10.1), > or = 20,000 RNA copies/ml (P = 0.012; RH, 8.9), and CD4+ T-cell count < 350 x 10(6)/l (P = 0.005; RH, 10.4). CONCLUSIONS: Codon 215 mutation, serum HIV RNA and CD4 T-cell count are independent predictors of progression in ZDV-experienced asymptomatic subjects. Furthermore, thymopentin delays HIV disease progression in the presence of a key ZDV resistance mutation as well as high viral load and low CD4+ T-cell counts.

Adjuvants, Immunologic↗

Middle latency auditory evoked potentials during repeated transitions from consciousness to unconsciousness.

We have investigated the relationship between changes in the middle latency auditory evoked potentials during alternating periods of consciousness and unconsciousness produced by propofol infusion combined with spinal anaesthesia for total knee replacement. Eleven patients completed the study, of whom two had recollection of events after the onset of the anaesthetic. There were no significant differences in heart rate or systolic arterial pressure between any conscious and unconscious period. With the first change from consciousness to unconsciousness, latencies of Na, Pa and Nb increased from mean (SD) starting values of 20.0 (1.4), 31.7 (1.0) and 42.8 (1.6) ms to 22.5 (2.0), 39.3 (2.1) and 57.8 (4.4) ms, respectively. During successive transitions from unconsciousness to consciousness, awake latencies were slightly higher than those of baseline awake, whereas anaesthetised latencies were similar to the ones obtained during the first period of unconsciousness. The consistent changes demonstrated, suggest that the auditory evoked potentials could represent a reliable indicator of potential awareness during anaesthesia.

Aged↗

In vitro function and durability assessment of a novel polyurethane heart valve prosthesis.

While flexible-leaflet, central-flow prosthetic heart valves promise relief from anticoagulation therapy, they continue to be restricted by inadequate durability. In consequence, a novel trileaflet valve, made entirely from polyurethane, has been developed. A batch of 6 consecutively manufactured polyurethane valves was subjected to hydrodynamic function and accelerated fatigue testing. Computerized data acquisition and control systems have been introduced to improve valve testing methodologies. In terms of hydrodynamic function, the polyurethane valve demonstrates transvalvular pressure gradients similar to those for a bioprosthetic valve (Carpentier-Edwards) and levels of retrograde flow significantly less than those for either the bioprosthetic valve or a bileaflet mechanical valve (St Jude Medical). The equivalent of 10 years of cycling without failure has been exceeded by all 6 polyurethane valves in accelerated fatigue tests with 2 valves remaining intact after 674 million cycles (equivalent to approximately 17 years) in continuing tests. Highspeed photography revealed considerable differences in leaflet motion between valves cycled at accelerated and physiological rates.

Biocompatible Materials↗