Search PubMed⌕ Search

Biomedical subjects

A C Boccara

Publications and source records attributed to A C Boccara.

6 recordsLinked to original sources

Stroboscopic ultrahigh-resolution full-field optical coherence tomography.

We present a new technique that produces en face tomographic images with a 10-micros acquisition time per image. The setup consists of an interference microscope with stroboscopic illumination provided by a xenon arc flash lamp (10-micros flashes at 15 Hz). The tomographic images are obtained from two phase-opposed interferometric images recorded simultaneously by two synchronized CCD cameras. Transverse resolution better than 1.0 microm is achieved by use of high-numerical-aperture microscope objectives. The short coherence length of the source yields an axial resolution of 0.9 microm. 3 x 3 pixel binning leads to a detection sensitivity of 71 dB. Our system is suitable for various applications, particularly in biology for in vivo cellular-level imaging.

Animals↗

Heterodyne detection of multiply scattered monochromatic light with a multipixel detector.

A new technique is presented for measuring the spectral broadening of light that has been multiply scattered from scatterers in motion. In our method the scattered light is detected by a heterodyne receiver that uses a CCD as a multipixel detector. We obtain the frequency spectrum of the scattered light by sweeping the heterodyne local oscillator frequency. Our detection scheme combines a high optical etendue (product of the surface by the detection solid angle) with an optimal detection of the scattered photons (shot noise). Using this technique, we measure, in vivo, the frequency spectrum of the light scattered through the breast of a female volunteer.

Breast↗

Pulsed acousto-optic imaging in dynamic scattering media with heterodyne parallel speckle detection.

We present a new detection scheme for acousto-optic tomography based on pulsed-wave ultrasound and illumination combined with heterodyne parallel speckle detection. This setup can perform tomographies inside several-centimeter-thick scattering samples. Test experiments confirm the suitability of this method for performing tomographies inside various types of optically scattering media, including liquids.

Acoustics↗

Three-dimensional cellular-level imaging using full-field optical coherence tomography.

An ultrahigh-resolution full-field optical coherence tomography (OCT) system has been developed for cellular-level imaging of biological media. The system is based on a Linnik interference microscope illuminated with a tungsten halogen lamp, associated with a high-resolution CCD camera. En face tomographic images are produced in real time, with the best spatial resolution ever achieved in OCT (0.7 microm x 0.9 microm, axial x transverse). A shot-noise limited detection sensitivity of 80 dB can be reached with an acquisition time per image of 1 s. Images of animal ophthalmic biopsies and vegetal tissues are shown.

Animals↗

Infra-red thermography revealed a role for mitochondria in pre-symptomatic cooling during harpin-induced hypersensitive response.

The establishment of Erwinia amylovora harpin-induced hypersensitive response (HR) in Nicotiana sylvestris was followed by infra-red thermography (IRT). Three to four hours after elicitation, the temperature decreased in the harpin-infiltrated zone associated to stomatal opening. The marked drop in temperature which reached 2 degrees C and preceded necrosis symptoms for several hours, is thus likely caused by higher transpiration. Neither of these effects was observed in a respiratory mutant, affected in complex I structure and function and over-expressing alternative oxidase, indicating that they are directly or indirectly mediated by mitochondrial function. However, as the HR establishment was similar in both wild type and mutant, cell death was either uncorrelated with the observed epidermal changes or occurred by a different signalling pathway in the two genotypes. IRT revealed a novel aspect of plant-pathogen interactions and could be applied to screen for mutants affected in elicitor signalling and/or for respiratory mutants.

Bacterial Outer Membrane Proteins↗

Apertureless scanning near-field magneto-optical microscopy of magnetic multilayers.

We imaged magnetic domains in Pt/Co/Pt multilayers using an apertureless scanning near-field optical microscope operating in reflection mode. As the magneto-optical effects are weak for this kind of structure, a polarization modulation technique with a photoelastic modulator was used to reveal the contrast between magnetic domains. In the case of a Pt/Co/Pt trilayer structure, a strong improvement in lateral resolution is observed compared with far-field magneto-optical images and good sensitivity is achieved. In the case of a Pt/[Co/Pt]Pt multilayer structure, stripe domains of 200 nm width could be resolved, in good agreement with images obtained by magnetic force microscopy on the same structure.

Journal Article↗