Photon scatter in intensity modulating filters evaluated by first Compton scatter and Monte Carlo calculations and experiments in broad beams.

High-atomic-number materials may be used as intensity modulating filters for inverse radiation treatment planning with photon beams. Such filters, when placed in a bremsstrahlung beam, attenuate the primary fluence, but also produce scattered photons that will reach the patient. To account for such effects in the optimization of photon beam intensities a semiempirical method based on narrow and broad beam transmission measurements was used to quantify the number of scattered photons produced in these filters. The method was verified by performing analytical calculations based on first scatter and a Monte Carlo simulation in 6 and 18 MV photon beams. The resultant experimental transmission ratios agree with calculations by these methods within 2 per cent under the experimental conditions investigated. The semiempirical method can thus be used as a basis for preliminary decision-making to select the proper material for intensity modulating filters and can provide a fast method to perform independent quality checks of the calculation accuracy of dose planning systems. Change in beam penetration is of less concern when treatments of target volumes at smaller depths are of interest. A 10 g cm(-2) thick filter made of low-melting-point alloy produces a change in percentage depth dose of less than 2 per cent for depths larger than 10 cm independent of field size. Similarly the scatter correction modifies the dose distribution by less than 5-10 per cent in most cases.

Models, Statistical↗

Comparative dosimetry in narrow high-energy photon beams.

A comparison of the response of different dosimeters in narrow photon beams (phi > or = 4 mm) of 6 and 18 MV bremsstrahlung has been performed. The detectors used were a natural diamond detector, a liquid ionization chamber, a plastic scintillator and two dedicated silicon diodes. The diodes had a very small detection volume and one was a specially designed double diode using two parallel opposed active volumes with compensating interface perturbations. The characteristics of the detectors were investigated both for dose distribution measurements, such as depth-dose curves and lateral beam profiles, and for output factors. The dose rate and angular dependence of the diamond and the two diodes were also studied separately. The depth-dose distributions for small fields agree well for the diamond, the scintillator and the single diode, while the measured dose maximum for the double diode is about 1% higher and for the liquid chamber about 1% lower than the mean of the others when normalized at a depth of 10 cm. The plastic scintillator and the liquid ionization chamber detect a penumbra width that is slightly broadened due to the influence of their finite size, while the double diode may even underestimate the penumbra width due to its small size and high density. When corrected for the extension of the detector volume a good agreement with Monte Carlo calculated beam profiles was obtained for the plastic scintillator and the liquid ionization chamber. Profiles measured with the diamond show an asymmetry when positioned with the smallest dimension facing the beam, while the double diode, the scintillator and the liquid chamber measure symmetric profiles irrespective of positioning. Significant differences in the output factors were obtained with the different detectors. The natural diamond detector measures output factors close to those with an ionization chamber (less than 1% difference) for field sizes between 3 x 3 and 15 x 15 cm2, but overestimates the output factors for large fields and underestimates the output factors for the smallest field sizes. The single and double diodes overestimated the output factor for large field sizes by up to 7 and 12% respectively due to the high content of low-energy photons. The double diode, and to some extent the single diode, also showed a relative increase in response compared with the more water equivalent liquid chamber and plastic scintillator at the smallest fields where there is a lack of lateral electron equilibrium. Both the plastic scintillator and the liquid chamber also show responses that deviate from the ionization chamber for larger field sizes. The major deviations can be explained based on the characteristics of the sensitive materials and the construction of the detectors.

Dose-Response Relationship, Radiation↗

Comparison of conformal radiation therapy techniques within the dynamic radiotherapy project 'Dynarad'.

The objective of the dynamic radiotherapy project 'Dynarad' within the European Community has been to compare and grade treatment techniques that are currently applied or being developed at the participating institutions. Cervical cancer was selected as the tumour site on the grounds that the involved organs at risk, mainly the rectum and the bladder, are very close to the tumour and partly located inside the internal target volume. In this work, a solid phantom simulating the pelvic anatomy was used by institutions in Belgium, France, Greece, Holland, Italy, Sweden and the United Kingdom. The results were evaluated using both biological and physical criteria. The main purpose of this parallel evaluation is to test the value of biological and physical evaluations in comparing treatment techniques. It is demonstrated that the biological objective functions allow a much higher conformality and a more clinically relevant scoring of the outcome. Often external beam treatment techniques have to be combined with intracavitary therapy to give clinically acceptable results. However, recent developments can reduce or even eliminate this need by delivering more conformal dose distributions using intensity modulated external dose delivery. In these cases the reliability of the patient set-up procedure becomes critical for the effectiveness of the treatment.

European Union↗

Optimized radiation therapy based on radiobiological objectives.

In the broad field of radiation therapy optimization, both simple and complex problems have their origins in the interaction of the radiation beams with the biological structures of normal and malignant tissues of the human body. Therefore, it is no great surprise that many treatment optimization problems are best handled by the use of well-designed radiobiological models. The classic way of quantifying dose-response relations for tumors and normal tissues as well as their cross-correlation with each other and their dependence on the underlying genetic and molecular biology of the cell are first briefly reviewed. Radiobiological objective functions, such as the probability of achieving complication-free cure and its expectation value under influence of stochastic processes during the course of treatment, are defined and shown to solve many of the problems of radiation therapy planning. Finally, it is shown through the use of these quantifiers that, simply by introducing biologically optimal intensity modulated dose delivery, the treatment outcome can be improved by about 20% or more in cases with a complex spread of the disease. Once radiobiological optimal plans have been developed, they can be approximated by ordinary physical planning, but the biological objective functions are still needed to have a figure of merit for the quality of the treatment.

Dose-Response Relationship, Radiation↗

Aspects on the optimal photon beam energy for radiation therapy.

The selection of optimal photon beam energy is investigated both for realistic clinical bremsstrahlung beams and for monoenergetic photon beams. The photon energies covered in this investigation range from 60Co to bremsstrahlung and monoenergetic beams with maximum energies up to 50 MeV. One head and neck tumor and an advanced cervix tumor are investigated and the influence of beam direction is considered. It is shown that the use of optimized intensity modulated photon beams significantly reduces the need of beam energy selection. The most suitable single accelerator potential will generally be in the range 6-15 MV for both superficially located and deep-seated targets, provided intensity-modulated dose delivery is employed. It is also shown that a narrow penumbra region of a photon beam ideally should contain low-energy photons (< or =4 MV), whereas the gross tumor volume, particularly when deep-seated targets are concerned, should be irradiated by high-energy photons. The regions where low photon energies are most beneficial are where organs at risk are laterally close to the target volume. The situation is completely changed when uniform or wedged beams are used. The selection of optimal beam energy then becomes a very important task in line with the experience from traditional treatment techniques. However, even with a large number of uniform beam portals, the treatment outcome is substantially lower than with a few optimized intensity-modulated beams.

Female↗

Biologically based treatment planning.

The classical way of quantifying dose-response relations for tumors and normal tissues and their dependence on the genetic make up of the patient is briefly reviewed. Response quantifiers such as quality of life and the probability of achieving a complication-free cure are helpful in solving many of the problems of radiation therapy planning. It is shown, through the use of these quantifiers, that by introducing radiobiologically optimized, intensity-modulated dose delivery, the treatment outcome can be improved by as much as 20%, and more in cases with a complex spread of the disease. The real strength of the radiobiological models is to serve as a scientific tool for the development of treatment optimization so that the models are modified when the clinical response systematically deviates from the predictions of the models. In this way, the biological models serve as a continuously updated historical database that later on may replace the control arm in clinical trials and allow all patients to benefit from the latest developments in radiobiologically optimized treatment techniques.

Breast Neoplasms↗

Comparison of cell survival models for mixed LET radiation.

PURPOSE: Biophysical models for predicting survival for mixed LET radiations have been investigated by comparisons with experimental results from heavy ion irradiations. The aim was to choose a model for further theoretical studies on the effects of a variable RBE for protons. METHODS AND MATERIALS: Predicted survival curves by the Katz track-structure model, the linear quadratic model, LQ model, by Kellerer and Rossi and the lesion additivity model of Lam were compared to experimental survival curves for V79 cells that were irradiated with a mixture of nitrogen ions with an LET of either 78 or 165 keV/microm and 60Co gamma-rays. RESULTS: Results showed that all three models could predict survival within the uncertainty of the measurements for the different mixed radiation schedules used in this study. CONCLUSION: The choice of model could be made on other grounds, such as the type of model parameters and the availability of biological data for these parameters. Also, the possibility of including dose-rate effects and repair functions should be considered. For the purpose of carrying out theoretical studies on the effects of a variable RBE for protons, the LQ model was preferred.

Animals↗

Optimal electron and combined electron and photon therapy in the phase space of complication-free cure.

The possibility of using intensity-modulated high-energy electrons beams alone or in combination with photon beams to treat tumours located at depths from 5 cm to 25 cm has been investigated. A radiobiologically based optimization algorithm using the probability of complication-free tumour control has been used to calculate the optimal dose distributions. Two different target volumes have been used; one advanced cervical cancer with locally involved lymph nodes and one astrocytoma in the upper brain hemisphere. Treatments with only electron beams and also combinations between electron and photon beams have been investigated. The dependence of the expected treatment outcome on the beam energy and directions was investigated, and to some extent on the number of beam portals. It is shown that the beam direction intervals resulting in a high expected treatment outcome increase with increasing electron energy and also with some electron-photon combinations. For an eccentrically placed, not too deeply situated tumour surrounded by sensitive normal tissue it is shown that the expected treatment outcome can be improved by using electron beams in combination with photon beams compared with using two photon beams, and using two electron beams results in almost as high an expected treatment outcome. The possibility of improving the dose conformity from electron beams by adding photon fields parallel or orthogonal to the electron beams is demonstrated.

Algorithms↗

Stochastic optimization of intensity modulated radiotherapy to account for uncertainties in patient sensitivity.

The aim of the present work is to better account for the known uncertainties in radiobiological response parameters when optimizing radiation therapy. The radiation sensitivity of a specific patient is usually unknown beyond the expectation value and possibly the standard deviation that may be derived from studies on groups of patients. Instead of trying to find the treatment with the highest possible probability of a desirable outcome for a patient of average sensitivity, it is more desirable to maximize the expectation value of the probability for the desirable outcome over the possible range of variation of the radiation sensitivity of the patient. Such a stochastic optimization will also have to consider the distribution function of the radiation sensitivity and the larger steepness of the response for the individual patient. The results of stochastic optimization are also compared with simpler methods such as using biological response 'margins' to account for the range of sensitivity variation. By using stochastic optimization, the absolute gain will typically be of the order of a few per cent and the relative improvement compared with non-stochastic optimization is generally less than about 10 per cent. The extent of this gain varies with the level of interpatient variability as well as with the difficulty and complexity of the case studied. Although the dose changes are rather small (<5 Gy) there is a strong desire to make treatment plans more robust, and tolerant of the likely range of variation of the radiation sensitivity of each individual patient. When more accurate predictive assays of the radiation sensitivity for each patient become available, the need to consider the range of variations can be reduced considerably.

Dose-Response Relationship, Radiation↗

Composite energy deposition kernels for focused point monodirectional photon beams.

A 3D volume overlap algorithm has been developed for converting energy deposition kernels between arbitrary 2D and 3D irradiation geometries. The kernels can be used as convolution kernels in inverse radiation therapy planning and as accurate descriptions of the dose distributions for clinically important beam geometries. The new method of dose calculation combining Monte Carlo and analytical methods has introduced an improved accuracy in dose calculation on the fractional per cent level. The comparisons are also made for a wide range of photon spectra and irradiation geometries from narrow point monodirectional pencil beams to finite uniform beams, 4pi steradians isotropically converging beams and divergent beams from isotropic point sources. It is seen that the photon scatter penumbra is highest at low photon energies whereas the secondary electron penumbra is widest at high photon energies, making low energy beams more interesting for small targets and high energy beams most useful for large deep-seated targets.

Phantoms, Imaging↗

Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV.

The absorbed dose due to photonuclear reactions in soft tissue, lung, breast, adipose tissue and cortical bone has been evaluated for a scanned bremsstrahlung beam of end point 50 MeV from a racetrack accelerator. The Monte Carlo code MCNP4B was used to determine the photon source spectrum from the bremsstrahlung target and to simulate the transport of photons through the treatment head and the patient. Photonuclear particle production in tissue was calculated numerically using the energy distributions of photons derived from the Monte Carlo simulations. The transport of photoneutrons in the patient and the photoneutron absorbed dose to tissue were determined using MCNP4B; the absorbed dose due to charged photonuclear particles was calculated numerically assuming total energy absorption in tissue voxels of 1 cm3. The photonuclear absorbed dose to soft tissue, lung, breast and adipose tissue is about (0.11-0.12)+/-0.05% of the maximum photon dose at a depth of 5.5 cm. The absorbed dose to cortical bone is about 45% larger than that to soft tissue. If the contributions from all photoparticles (n, p, 3He and 4He particles and recoils of the residual nuclei) produced in the soft tissue and the accelerator, and from positron radiation and gammas due to induced radioactivity and excited states of the nuclei, are taken into account the total photonuclear absorbed dose delivered to soft tissue is about 0.15+/-0.08% of the maximum photon dose. It has been estimated that the RBE of the photon beam of 50 MV acceleration potential is approximately 2% higher than that of conventional 60Co radiation.

Absorption↗

Mixing intensity modulated electron and photon beams: combining a steep dose fall-off at depth with sharp and depth-independent penumbras and flat beam profiles.

For application in radiotherapy, intensity modulated high-energy electron and photon beams were mixed to create dose distributions that feature: (a) a steep dose fall-off at larger depths, similar to pure electron beams, (b) flat beam profiles and sharp and depth-independent beam penumbras, as in photon beams, and (c) a selectable skin dose that is lower than for pure electron beams. To determine the required electron and photon beam fluence profiles, an inverse treatment planning algorithm was used. Mixed beams were realized at a MM50 racetrack microtron (Scanditronix Medical AB, Sweden), and evaluated by the dose distributions measured in a water phantom. The multileaf collimator of the MM50 was used in a static mode to shape overlapping electron beam segments, and the dynamic multileaf collimation mode was used to realize the intensity modulated photon beam profiles. Examples of mixed beams were generated at electron energies of up to 40 MeV. The intensity modulated electron beam component consists of two overlapping concentric fields with optimized field sizes, yielding broad, fairly depth-independent overall beam penumbras. The matched intensity modulated photon beam component has high fluence peaks at the field edges to sharpen this penumbra. The combination of the electron and the photon beams yields dose distributions with the characteristics (a)-(c) mentioned above.

Electrons↗

Target, purging magnet and electron collector design for scanned high-energy photon beams.

A new method for producing very narrow and intense 50 MV bremsstrahlung beams with a half-width as low as 35 mm at a distance of 1 m from the target is presented. Such a beam is well suited for intensity modulation using scanned photon beams. An algorithm has been developed to minimize the width of the bremsstrahlung beam generated in a multilayer target by varying the individual layer thicknesses and atomic numbers under given constraints on the total target thickness and the mean energy of the transmitted electrons. Under such constraints the narrowest possible bremsstrahlung beam is obtained with a target composed of layers of monotonically increasing atomic number starting with the lowest possible value at the entrance side where the electrons impinge. It is also shown that the narrowest photon beam profile is associated with the highest possible forward photon yield. To be able to use the optimized target clinically it is desirable to be able to collect and stop all the electrons that are transmitted through the target. The electrons are most efficiently collected if they are kept close together, i.e. by minimizing the multiple scatter of the electrons and consequently the half-width of the generated bremsstrahlung beam. This is achieved by a thin low-atomic-number target. A dedicated electron stopper has been developed and integrated with the purging magnet. When the electron stopper is combined with a purging magnet, a primary photon collimator and a multileaf collimator, almost all of the transmitted electrons and their associated bremsstrahlung contamination can effectively be collected. The narrow photon beams from thin low-atomic-number targets have the additional advantage of producing the hardest and most penetrative photon spectrum possible, which is ideal for treating large deep-seated tumours.

Algorithms↗

An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion.

A new general beam optimization algorithm for inverse treatment planning is presented. It utilizes a new formulation of the probability to achieve complication-free tumour control. The new formulation explicitly describes the dependence of the treatment outcome on the incident fluence distribution, the patient geometry, the radiobiological properties of the patient and the fractionation schedule. In order to account for both measured and non-measured positioning uncertainties, the algorithm is based on a combination of dynamic and stochastic optimization techniques. Because of the difficulty in measuring all aspects of the intra- and interfractional variations in the patient geometry, such as internal organ displacements and deformations, these uncertainties are primarily accounted for in the treatment planning process by intensity modulation using stochastic optimization. The information about the deviations from the nominal fluence profiles and the nominal position of the patient relative to the beam that is obtained by portal imaging during treatment delivery, is used in a feedback loop to automatically adjust the profiles and the location of the patient for all subsequent treatments. Based on the treatment delivered in previous fractions, the algorithm furnishes optimal corrections for the remaining dose delivery both with regard to the fluence profile and its position relative to the patient. By dynamically refining the beam configuration from fraction to fraction, the algorithm generates an optimal sequence of treatments that very effectively reduces the influence of systematic and random set-up uncertainties to minimize and almost eliminate their overall effect on the treatment. Computer simulations have shown that the present algorithm leads to a significant increase in the probability of uncomplicated tumour control compared with the simple classical approach of adding fixed set-up margins to the internal target volume.

Algorithms↗

Beam characteristics and clinical possibilities of a new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation.

Not until the last decade has flexible intensity modulated three-dimensional dose delivery techniques with photon beams become a clinical reality, first in the form of heavy metal transmission blocks and other beam compensators, then in dynamic and segmented multileaf collimation, and most recently by scanning high-energy narrow electron and photon beams. The merits of various treatment unit and bremsstrahlung target designs for high-energy photon therapy are investigated theoretically for two clinically relevant target sites, a cervix and a larynx cancer both in late stages. With an optimized bremsstrahlung target it is possible to generate photon beams with a half-width of about 3 cm at a source to axis distance (SAD) of 100 cm and an initial electron energy of 50 MeV. By making a more compact treatment head and shortening the SAD, it is possible to reduce the half-width even further to about 2 cm at a SAD of 70 cm and still have sufficient clearance between the collimator head and the patient. One advantage of a reduced SAD is that the divergence of the beam for a given field size on the patient is increased, and thus the exit dose is lowered by as much as 1%/cm of the patient cross section. A second advantage of a reduced SAD is that the electron beam on the patient surface will be only about 8 mm wide and very suitable for precision spot beam scanning. It may also be possible to reduce the beamwidth further by increasing the electron energy up to about 60 MeV to get a photon beam of around 15 mm half-width and an electron beam as narrow as 5 mm. The compact machine will be more efficient and easy to work with, due to the small gantry and the reduced isocentric height. For a given target volume and optimally selected static multileaf collimator, it is no surprise that the narrowest possible scanned elementary bremsstrahlung beam generates the best possible treatment outcome. In fact, by delivering a few static field segments with individually optimized scan patterns, it is possible to combine the advantage of being able to fine tune the fluence distribution by the scanning system with the steeper dose gradients that can be delivered by a few static multileaf collimator segments. It is demonstrated that in most cases a few collimator segments are sufficient and often a single segment per beam portal may suffice when narrow scanned photon beams are employed, and they can be delivered sequentially with a negligible time delay. A further advantage is the increase of therapeutically useful photons and improved patient protection, since the pencil beam is only scanned where the leaf collimator is open. Consequently, some of the problems associated with dynamic multileaf collimation such as the tongue and groove and edge leakage effects are significantly reduced. Fast scanning beam techniques combined with good treatment verification systems allow interesting future possibilities to counteract patient and internal organ motions in real time.

Algorithms↗

Quantification of mean energy and photon contamination for accurate dosimetry of high-energy electron beams.

The scientific background of the standard procedure for determination of the mean electron energy at the phantom surface (E0) from the half-value depth (R50) has been studied. The influence of energy, angular spread and range straggling on the shape of the depth dose distribution and the R50 and Rp ranges is described using the simple Gaussian range straggling model. The relation between the R50 and Rp ranges is derived in terms of the variance of the range straggling distribution. By describing the mean energy imparted by the electrons both as a surface integral over the incident energy fluence and as a volume integral over the associated absorbed dose distribution, the relation between E0 and different range concepts, such as R50 and the maximum dose and the surface dose related mean energy deposition ranges, Rm and R0, is analysed. In particular the influence of multiple electron scatter and phantom generated bremsstrahlung on R50 is derived. A simple analytical expression is derived for the ratio of the incident electron energy to the half-value depth. Also, an analytical expression is derived for the maximum energy deposition in monoenergetic plane-parallel electron beams in water for energies between 2 and 50 MeV. Simple linear relations describing the relative absorbed dose and mass ionization at the depth of the practical range deposited by the bremsstrahlung photons generated in the phantom are derived as a function of the incident electron energy. With these relations and a measurement of the extrapolated photon background at Rp, the treatment head generated bremsstrahlung distribution can be determined. The identification of this photon contamination allows an accurate calculation of the absorbed dose in electron beams with a high bremsstrahlung contamination by accounting for the difference in stopping power ratios between a clean electron beam and the photon contamination. The absorbed dose determined using ionization chambers in heavily photon contaminated (10%) electron beams may be too low--by as much as 1.5%--without correction.

Electrons↗