Impact of ECG gating in contrast-enhanced MR angiography for the assessment of the pulmonary veins and the left atrium anatomy.

PURPOSE: Implementation of ECG gating in contrast-enhanced MR angiography (ceMRA) for improved visualization of the pulmonary veins, the left atrium, and the thoracic vessels. MATERIALS AND METHODS: CeMRA was performed on twelve patients with a history of recurrent atrial fibrillation for the purpose of an intra-individual comparison with and without ECG gating on a 1.5 Tesla MR system (Gyroscan Intera, Philips Medical Systems, Best, NL). Objective image quality parameters such as the signal-to-noise ratio (SNR) of the blood and the contrast-to-noise ratio (CNR) between the blood and myocardium or lung parenchyma were analyzed. The contour sharpness of the pulmonary veins, left atrium, ascending aorta, and pulmonary trunk was also measured. In addition, the artifact level was subjectively assessed by two observers blinded with respect to the sequence parameters. Statistically significant differences (p < 0.05) between the procedures were analyzed using the Wilcoxon test and Pearson Chi-square test. RESULTS: The use of ECG gating in ceMRA significantly reduced artifacts caused by cardiac motion and vessel pulsation. This in turn lead to a significant increase in the contour sharpness of the left atrium and the thoracic vessels. In addition, higher SNR and CNR were found using ECG-gated ceMRA compared to standard ceMRA. CONCLUSION: The use of ECG gating in ceMRA results in artifact-free and sharper delineation of the structures of the heart and thoracic vessels.

Artifacts↗

Effects of orthodontic treatment with fixed functional orthopaedic appliances on the condyle-fossa relationship in the temporomandibular joint: a magnetic resonance imaging study (Part I).

OBJECTIVES: This study aimed to verify the effects that corrective treatment for skeletal Class II malocclusions with fixed functional orthopaedic appliances has on the positions of the condyle within the glenoid fossa. METHODS: Orthodontic treatment progress was monitored in 20 patients by magnetic resonance imaging (MRI) at four defined points in time. Metric analysis of the temporomandibular joints was performed on the central slices of the images obtained in the closed-mouth position. To assess the positional relationship between condyle and fossa, the width of the joint spaces was measured. To compensate for individual variation of the condyle sizes, the Joint Space Index was calculated. The displacement of the condyle from the fossa was measured in the ventral and in the caudal dimension and the effective condyle reposition was computed. RESULTS: Upon adoption of the therapeutic position, the condyles were displaced from the centric position within the fossa toward caudal and ventral. At the end of treatment, they returned to their original position. No significant differences compared with initial findings were found in the width of the anterior or posterior joint spaces. CONCLUSION: For patients who received functional orthopaedic treatment for skeletal Class II correction with a fixed functional appliance, reduction to a physiological condyle-fossa relationship occurred bilaterally in the region of the joints. Our study suggests that the improved dental occlusion was not achieved at the price of a change to an unphysiological position in the temporomandibular joints.

Adolescent↗

Effects of orthodontic treatment with fixed functional orthopaedic appliances on the disc-condyle relationship in the temporomandibular joint: a magnetic resonance imaging study (Part II).

OBJECTIVES: This study aimed to verify the effects that corrective treatment for skeletal Class II malocclusions with fixed functional orthopaedic appliances has on the relative positions of the articular disc and the mandibular condyle. METHODS: Orthodontic treatment progress was monitored in 20 patients by magnetic resonance imaging (MRI) at four defined points in time. Visual inspection of the temporomandibular joints (TMJs) was performed on three slices each (lateral, central, medial) of closed-mouth and maximum-open parasagittal MRI. Metric analysis was performed on the central slices of the images obtained in the closed-mouth position. To assess the positional relationship in the sagittal dimension between the articular disc and the mandibular condyle, both methods were used. RESULTS: The comparison of pre-treatment and post-treatment findings revealed in none of the joints that the disc-condyle relationship had been adversely affected as a consequence of the treatment. Rather, the outcome was an improved relationship in a total of eight joints. After groups of joints had been defined by disc position, metric analysis revealed a significantly improved positional relationship in those joints in which an anterior disc displacement had been found initially. CONCLUSION: Orthodontic treatment with a rigid, fixed functional appliance to correct skeletal distoclusion results in the following side effects on the disc-condyle relationship in the TMJ: the treatment does not have adverse effects on initially physiological disc-condyle relationships; in TMJs with initial partial or total anterior disc displacement, improved disc position can be achieved.

Adolescent↗

Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular function.

OBJECTIVE: To evaluate whether myocardial strain and strain rate calculated from two dimensional echocardiography by automatic frame-by-frame tracking of natural acoustic markers enables objective description of regional left ventricular (LV) function. METHODS: In 64 patients parasternal two dimensional echocardiographic views at the apical, mid-ventricular and basal levels were obtained. An automatic frame-by-frame tracking system of natural acoustic echocardiographic markers was used to calculate radial strain, circumferential strain, radial strain rate and circumferential strain rate for each LV segment in a 16 segment model. Cardiac magnetic resonance imaging (cMRI) was performed to define segmental LV function as normokinetic, hypokinetic or akinetic. RESULTS: Image quality was sufficient for adequate strain and strain-rate analysis from two dimensional echocardiographic images obtained from parasternal views in 88% of segments. Obtained radial strain data were highly reproducible and analysis was affected by only small intraobserver (mean 4.4 (SD 1.6)%) and interobserver variabilities (7.3 (2.5)%). Each of the analysed strain and strain-rate parameters was significantly different between segments defined as normokinetic, hypokinetic or akinetic by cMRI (radial strain 36.8 (10.5)%, 24.1 (7.5)% and 13.4 (4.8)%, respectively, p < 0.001). Peak systolic radial strain enabled detection of hypokinesis or akinesis with a sensitivity of 83.5% and a specificity of 83.5% (cut off value 29.1%, receiver operating characteristic (ROC) curve area 0.905, 95% CI 0.883 to 0.923). Peak systolic radial strain analysis also enabled detection of akinesis versus hypokinesis with a sensitivity of 82.7% and a specificity of 94.5% (cut off value 21.0%, ROC curve area 0.946). Peak systolic radial strain-rate analysis was less accurate than peak systolic radial strain analysis to detect cMRI-defined segmental function abnormalities. The accuracy of peak systolic circumferential strain and strain rate was similar to that of corresponding radial parameters. CONCLUSIONS: Frame-by-frame tracking of acoustic markers in two dimensional echocardiographic images enables accurate analysis of regional systolic LV function.

Adult↗

New optional IVC filter for percutaneous retrieval--in vitro evaluation of embolus capturing efficiency.

PURPOSE: In-vitro evaluation of a new caval filter (Cook Celect Filter) developed for delayed percutaneous retrieval in comparison to the Gunther Tulip filter. MATERIALS AND METHODS: The new Celect filter is constructed on the basis of the Tulip filter and consists of 4 primary anchoring legs and additional 8 thinner secondary wires to stabilize the filter and to guarantee adequate filtering efficiency. The filtering wires are of the same amount and equal distribution as the filtering wires of the Tulip filter. The secondary wires are arranged in such a way that percutaneous filter retrieval should be possible even if the wires are incorporated into the caval wall. In a flow model (tube size ø15-, ø22- and ø30 mm), the filter was exposed to single and multiple emboli (blood clots) of different sizes (3 x 5, 3 x 10, 5 x 10, 3 x 20, 5 x 20, 7 x 10, 7 x 20 to 10 x 24 mm) to analyse the embolus capturing efficiency under different conditions including eccentric and concentric, horizontal and vertical positions in comparison to the Tulip filter. All testing was carried out in SPSS analytic software; statistical significance was assumed for p-values < 0.05. RESULTS: The in-vitro embolus capturing efficiency of the Celect filter proved to be equivalent to the Tulip filter. In the single-embolus test, 91.6 % of the clots were captured by the Celect filter and 87.2 % by the Tulip filter (p = 0.042). Large clots ranging from 7 x 10 to 10 x 24 mm were captured in all cases, whereas the capture rates for the 3 x 5-mm and 3 x 10-mm clots were lower. The filters captured significantly more clots in the concentric than in the eccentric location. There was no significant difference between the overall capture rates of the two filters in the multi-clot test (72.2 % vs. 75.1 %), which showed deterioration of filter function during multiple clot exposure. With the 15-mm tube, the Celect filter had a significantly higher capture rate than the Tulip filter, whereas it was lower with the ø30-mm tube. There was no significant difference between the filters in a ø22-mm tube. The pressure gradient across the filters when exposed to blood clots ranged from 4.9 - 7.4 mm Hg for the Celect filter and 5.7 - 6.8 mm Hg for the Tulip filter in the single-embolus testing. There was no significant difference in the multi-clot tests. CONCLUSION: The new Celect filter showed similar in-vitro capture properties as the Gunther Tulip filter and deserves further in-vivo testing.

Blood Flow Velocity↗

[High-resolution T1-weighted MR-lymphography of inguinal lymph nodes after interstitial application of Gadomer-17 in animal experiments].

PURPOSE: To evaluate the microstructural anatomy of inguinal lymph nodes in pigs after interstitial MR-lymphography with the dendritic contrast agent Gadomer-17. MATERIAL AND METHODS: High-resolution T1-weighted MR-lymphography was performed in inguinal lymph nodes of 10 domestic pigs (39 - 46 kg) after subcutaneous injection of 10 mumol/kg body weight Gadomer-17 in the hind legs of the animals. A 1.5T MR scanner and a ring-shaped surface coil were used. Two different high-resolution gradient-echo sequences with additionally reconstructed maximum-intensity projections were evaluated in a total of 20 lymph nodes. The high-resolution MR-findings were correlated with the histologic sections of the excised inguinal lymph nodes. RESULTS: Coronal T1-weighted 3D gradient-echo images (TR = 20 msec, TE = 6.1 - 8.3 msec, FA = 20 degrees ) with a slice thickness of 1 mm, a field-of-view of 120 mm and a matrix size of 256 x 256 (reconstructed to 1024 x 1024 voxels) yielding a reconstructed in-plane resolution of 117 x 117 microm (2) were best suited for the high-resolution MR lymphography of inguinal lymph nodes and enabled the differentiation of the hyperintense lymph node sinuses and hypointense lymphoid parenchyma of each lymph node (100 %). Even dilated lymphatic vessels evident in the histologic specimen were best demonstrated on the MIP images. CONCLUSION: High-resolution interstitial MR lymphography with Gadomer-17 allows the visualization of different tissue compartments of inguinal lymph nodes. This new technique is feasible on a routine 1.5T scanner and may offer potential for the detection of micrometastases in lymph nodes of cancer patients.

Animals↗

[Local lysis with alteplase for the treatment of acute embolic leg ischemia following the use of the duett closure device: preliminary results].

PURPOSE: To analyze retrospectively the result of the alteplase lysis therapy of embolic complications following the use of the Duett closure device. METHODS AND MATERIALS: For 3.5 years, the Duett closure device was used in 1,398 angiographies to close the femoral puncture site. The Duett device consists of a balloon and a liquid procoagulant containing collagen and thrombin, which is injected into the puncture tract under endovascular balloon protection of the arterial puncture site. In 9 patients (0.64 %), the procoagulant was incidentally injected into the femoral artery causing acute leg ischemia. Eight patients received local lysis therapy with alteplase via a contralateral femoral access. One patient underwent surgery. On average, 21 mg alteplase (4 - 35 mg) were administered within 14 h (4 - 21 h). The course of the lysis was followed angiographically and clinically. All patients were interviewed by telephone 23 months (4 - 35 months) later. RESULTS: In 3 patients, lysis was complete. In 5 patients, only little thrombotic material remained. In all patients, symptoms of ischemia resolved completely within the first hours after initiation of lysis. In 5 cases, bleeding occurred at the puncture site closed with the Duett device during lysis, including development of a false aneurysm in 2 cases. Complications led to premature termination (n = 2) or interruption of the lysis (n = 3). All complications were treated conservatively. Clinically, long-term sequelae were paresthesia and hypoesthesia in the lower leg and foot in 2 patients treated with lysis, and in the patient who underwent surgery. CONCLUSION: Very rarely occurring embolic complications after use of the Duett closure device can be effectively treated with alteplase lysis. A high rate of complications is to be expected at the puncture site closed with the Duett device.

Acute Disease↗

[Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI].

PURPOSE: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. MATERIALS AND METHODS: In 16 patients (14 males, 2 females, mean age 56.8 +/- 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5 % of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. RESULTS: All parameters were found to have an excellent correlation between MSCT and MRI data (Pearson's correlation coefficient 0.95 - 0.99), without clinically relevant differences between both modalities. On average, the difference between both methods was 0.5 ml for ESV, 0.8 ml for EDV, 1.3 ml for SV, 0.9 % for EF and 2.3 g for MM. Image quality was slightly better for MRI (1.5 +/- 0.65) than for MSCT (1.64 +/- 0.74). CONCLUSION: Retrospectively ECG-gated MSCT angiography can not only visualize the coronary arteries but also enables precise quantification of the left ventricular function from the same MSCT data set.

Aged↗

[MR-guided coil embolisation of renal arteries in an animal model].

PURPOSE: To test the feasibility of MR-guided coil embolization with passive visualization in an animal model. MATERIALS AND METHODS: All experiments were performed on a 1.5 T interventional MR-scanner (Gyroscan ACS-NT, Philips, Netherlands). A gradient echo sequence was combined with radial k-space acquisition and sliding window reconstruction technique to calculate the raw data with a specially designed back projector, yielding a frame rate of 20 images per second. The images were directly displayed on LCD-screens next to the MR scanner. A multipurpose catheter with dysprosium markers was placed into the renal arteries of two pigs under MR guidance, and a nitinol coil and platinum coil each were deployed. The position of the coils was verified with magnetic resonance angiography and conventional angiography. RESULTS: MR-guided catheterization of renal arteries with subsequent coil embolization was successfully carried out but the configuration of the coils could not be visualized on the MR images. CONCLUSION: MR-guided coil embolization of renal arteries is feasible. Exact guidance of coil deployment is not attainable with passive visualization.

Angiography, Digital Subtraction↗

[Interstitial T1-weighted MR lymph fistulography with Gadomer-17 in an experimental animal model].

PURPOSE: To visualize and localize fistulas of the thoracic duct with interstitial T 1 -weighted MR lymphography using Gadomer-17. MATERIALS AND METHODS: In 10 domestic pigs, leaks of the thoracic duct were created surgically or interventional-radiologically. The lymphatic leakage was located within the abdominal portion of the thoracic duct in 5 pigs, within the thoracic portion of the thoracic duct in 3 pigs, and in both, abdominal and thoracic portions of the thoracic duct, in 2 pigs. Subsequently, 10 micro mol/kg KG Gadomer-17 (1.5-1.8 ml) was administered interstitially in both hind legs of the animals. MR lymphography was performed with a 1.5 T MR unit using two different 3D gradient echo sequences before and 10 - 90 minutes after administration of contrast material. RESULTS: Leaks within the abdominal portion of the thoracic duct were directly visible as opacified fistulas. Indirect signs of active lymphatic fistulas were increasing extravasations of contrast material and free abdominal fluid. The 3D gradient echo sequence with the highest planar resolution (TR = 8,7 - 8,8 ms, TE = 4,2 - 4,3 ms, FA = 40 degrees, matrix size = 327 x 512) was best suited for distinct delineation of the lymphatic system and detailed demonstration of the thoracic duct fistulas. Intrathoracic leaks could not be demonstrated by MR lymphography due to reduced lymphatic flow or extravasated contrast medium at the abdominal puncture site. CONCLUSION: Interstitial MR lymphography with Gadomer-17 allows sensitive detection and localization of abdominally located leaks of the thoracic duct.

Animals↗

Aneurysmal bone cyst: value of MR imaging and conventional radiography.

Our objective was to investigate the accuracy and the diagnostic value of different imaging features of primary aneurysmal bone cysts (ABC) in conventional radiographs and MRI. Conventional radiographs and MR images of 34 patients with a suspected aneurysmal bone cyst were reevaluated by six independent radiologists in a blinded fashion. Morphological features, MR signal characteristics, and contrast enhancement patterns were assessed. Diagnoses were correlated with histology. Sensitivity and specificity of the different imaging findings for each imaging technique were calculated. In 24 patients ABC was histologically proven. In 10 cases diagnoses other than ABC were established. Conventional radiography and MRI each demonstrated a sensitivity of 76.4 and 77.8% with a specificity of 55.0 and 66.7%, respectively. With combined use of both imaging modalities sensitivity and specificity increased to 82.6 and 70%, respectively. The ABC was significantly more often seen as circumscribed lesion with bone expansion, lobulation, septa, and pathological cortical bone reaction than those cases with different diagnoses. Septal contrast enhancement proved to be a useful MR imaging finding in suspected ABC. The combined use of conventional radiographs and MRI revealed the highest sensitivity in the diagnosis of ABC in relation to histology. Magnetic resonance imaging provides improved diagnostic specificity and valuable information on soft tissue changes.

Adolescent↗

[Percutaneous radiofrequency ablation of liver malignancies: first experience with a 200-W radiofrequency generator].

PURPOSE: To evaluate the effectiveness of a percutaneous radiofrequency ablation device, consisting of a LeVeen probe and a newly developed 200-W radiofrequency generator. MATERIAL AND METHOD: In 20 patients (9 male, 11 female), 30 primary and secondary liver malignancies were treated by CT-guided percutaneous radiofrequency ablation. The patients were separated in a potentially curable (n = 10) and a palliative (n,= 10) treatment group. The treatment was performed using an umbrella-shaped LeVeen probe with a diameter of 3.5 cm or 4 cm and a 200-W generator (Radiotherapeutics, Mountain View, CA, USA). All interventions were performed under general anesthesia by a standardized treatment protocol. The size of the lesions treated ranged from 2.2 x 2 x 2 cm to 10.8 x 10.1 x 10.5 cm. RESULTS: In all patients, the correct placement of the probe and radiofrequency ablation was technically successful. In two patients more than one treatment session was necessary to achieve the intended treatment result. In all patients of the potentially curable group a complete tumor necrosis could be achieved, whereas in the palliative treatment group complete tumor necrosis was only achievable in one patient. The achieved necrosis size ranged from 2.4 x 2.8 x 2.5 cm to 9.2 x 8 x 10.5 cm. In one patient a colon fistula was observed 4 weeks after treatment. No further complications were observed. The follow-up period ranges from 1 to 15 months (mean 4.5 months). CONCLUSION: By use of a powerful generator in combination with a LeVeen probe percutaneous treatment of even large liver tumors is possible. Radiofrequency ablation is a safe procedure for the minimal-invasive therapy of non resectable liver neoplasms.

Adult↗

[Selective CT mesentericography in the diagnostics of obscure overt intestinal bleeding: preliminary results].

AIM: To evaluate intra-arterial CT mesentericography (CTM) in the diagnostics of severe obscure overt intestinal bleeding in comparison with conventional mesentericography (MG) and surgery. METHODS: In 8 patients (23 - 82 years, mean 59 years), CTM was performed via the catheter left in the superior mesenteric artery after MG to detect the source of bleeding. Early and late-phase spiral CT scans were acquired after administration of contrast medium. Active bleeding was considered to be present if extravasation of contrast medium into the bowel was found. The results of MG and CTM were compared with the results of surgery. RESULTS: With MG active bleeding was found in one patient, with CTM in five patients. In three patients, both MG and CTM were negative. Six patients underwent surgery. Five cases of bleeding detected with CTM were confirmed by surgery. In one case, bleeding found with CTM was not confirmed by surgery. One patient underwent surgery although all imaging procedures were negative. The source of bleeding remained unknown. Surgically, the site of bleeding was located in the jejunum in 3 patients (jejunitis, jejunal ulcers, carcinoid), one patient had a diverticulum in the ascending colon. The colonic bleeding site was correctly localized with CTM, whereas the small bowel bleeding could only roughly be assigned to the proximal or distal jejunum or jejunoileal transition area. CONCLUSION: Preliminary results indicate that selective CTM is superior to MG in the evaluation of severe obscure overt intestinal bleeding.

Adult↗

Real-time MR Guidance for inferior vena cava filter placement in an animal model.

It was the aim of this study to examine the feasibility of real-time magnetic resonance (MR) imaging for MR-guided placement of inferior vena cava (IVC) filters, which were placed in five pigs via a femoral approach. The introducer sheath and dilator were marked with Dysprosium rings. The procedures were performed under MR guidance with use of a 1.5-T ACS-NT imager. Radial filling of k-space in conjunction with the sliding window reconstruction technique achieved real-time MR imaging with a frame rate of 20 images/sec. Simultaneous real-time visualization of the vascular anatomy and interventional instruments was achieved under real-time conditions and allowed correct placement of IVC filters in all five cases as confirmed by radiographic angiography.

Animals↗

[Differentiation of serous and purulent fluids in vitro and in vivo by means of diffusion-weighted MRI].

AIM: The aim of this study was to test the feasibility for differentiation of serous fluid collections and abscess fluid with diffusion-weighted imaging and to compare three different diffusion sequences. MATERIAL AND METHODS: Thirteen puncture samples (6 serous, 7 purulent) and 19 patients with either serous fluid collections (n = 12) or abscesses (n = 7) were examined with diffusion-weighted spin-echo (SE), stimulated-echo (STE), and fatsuppressed SE (SE-SPIR) sequences. For in vitro studies 4 different b-factors (0, 87, 355, 798 s/mm2 in SE and SE-SPIR and 0, 51, 204, 460 s/mm2 in STE) were chosen and the apparent diffusion coefficient (ADC) was calculated. For in vivo measurements identical sequences with two b-factors (0.598 s/mm2 in SE and SE-SPIR and 0.360 s/mm2 in STE) were applied and the normalized signal attenuation was calculated. A navigator-echo technique and peripheral pulse triggering was used for motion artifact reduction. RESULTS: The in vitro study yielded an ADC of serous fluid, which was close to that of free water, whereas for purulent fluid a significantly lower ADC was calculated. During in vivo examinations, serous fluids showed a strong signal attenuation (down to 22-32% of basic value) compared to a minor signal attenuation in purulent fluids (down to 86-94% of basic value) (p < 0.05). CONCLUSIONS: In summary, with all three investigated diffusion schemes serous and purulent fluids can be clearly differentiated.

Abscess↗

Implantation of a new access device for hemodialysis (Dialock): initial experience in 5 patients.

PURPOSE: A new hemodialysis access port system was implanted. METHODS: The Dialock consists of a port-like double-valve, implanted subcutaneously below the clavicle, which is attached to two catheters, placed in the right atrium via the jugular vein. The device has been implanted in 5 patients (4 female, 1 male). RESULTS: In all 5 patients the implantation of the catheters and the port was technically successful. Total average duration of dialysis was 3.6 months. Two patients developed a port pocket hematoma 10-14 days post implantation, one of them required surgical revision. One port was explanted due to septicemia, whereas a port infection was not confirmed. One patient showed a thrombotic occlusion of both catheter tips 8 days after implantation, fixed by catheter exchange. Another patient presented with slight migration of the port catheters, which was managed by refixation of the port within the pocket. Beside these complications, the devices were working well. CONCLUSION: The Dialock system offers an interesting alternative to external catheters for hemodialysis. With respect to the complications it deserves further studies to determine its future role in the field of vascular access.

Catheters, Indwelling↗