A B Froese

Publications and source records attributed to A B Froese.

At least 37 records · Page 2Linked to original sources

Lung volume maintenance prevents lung injury during high frequency oscillatory ventilation in surfactant-deficient rabbits.

Controversy exists whether high frequency oscillatory ventilation with an active expiratory phase (HFO-A) should be used at low ventilator pressures or high alveolar volumes to minimize lung injury in the atelectasis-prone lung. We therefore ventilated 20 anesthetized, tracheostomized rabbits made surfactant-deficient by lung lavage in 1 of 3 ways: HFO-A at a high lung volume (HFO-A/HI), HFO-A at a low lung volume (HFO-A/LO), or conventional mechanical ventilation (CMV); all received 100% oxygen for 7 h. We examined oxygenation, lung mechanics, and lung pathology. Arterial oxygenation in the HFO-A/HI rabbits was kept greater than 350 mm Hg. Mean lung volume above FRC in these animals was 23.4 ml/kg. In rabbits ventilated with HFO-A/LO and CMV, arterial oxygen tensions were 70 to 100 mm Hg. Mean lung volumes were 7.8 and 4.3 ml/kg, respectively. Total respiratory system pressure-volume curves (P-V curves) showed no change from baseline in the HFO-A/HI group after 7 h of ventilation. The low lung volume groups (HFO-A/LO and CMV) showed a diminution in hysteresis of their P-V curves, lower total respiratory system compliance, more hyaline membranes and severe airway epithelial damage. (All changes significant with p less than 0.05). We conclude that maintenance of alveolar volume is a key mechanism in the prevention of lung injury during mechanical ventilation of the atelectasis-prone lung. For optimal outcome using high frequency oscillatory ventilation, alveoli must be actively reexpanded and then kept expanded using appropriate mean airway pressures.

Airway Resistance↗

High-frequency oscillatory ventilation in premature infants with respiratory failure: a preliminary report.

High-frequency ventilation has been used successfully to manage life-threatening complications in premature infants with lung disease. Here we report a preliminary assessment of the efficacy and safety of high-frequency oscillatory ventilation-(HFO-A, A = active expiratory phase) when used as a primary ventilator in 11 infants of 24-34 weeks gestation who required ventilatory support. HFO-A was initiated after no more than 5.5 hr of conventional mechanical ventilation (CMV). HFO-A at 15 Hz was used for 12-203 hr following a protocol designed for rapid reduction of FI02 requirements. CO2 elimination was easily achieved in all infants. Oxygenation was satisfactory, except in one infant with congenital pneumonia. There were four deaths during HFO-A: two pulmonary (one congenital pneumonia; one pulmonary hemorrhage) and two nonpulmonary. The HFO-A protocol utilized lung volume recruitment maneuvers plus mean airway pressures (MAwP) greater than those generally used early in the course of CMV. Therefore, in a subset of infants less than or equal to 29 weeks' gestation with respiratory distress syndrome (RDS), ventilator pressures and gas exchange were compared in infants treated with either HFO-A or CMV. Maximum MAwP levels were reached earlier in six infants on HFO-A (5.2 +/- 2.5 hr; mean +/- SD) than in a comparable group of 9 CMV-treated infants (36 +/- 1 hr). This earlier use of high MAwP lowered the FI02 to less than 0.4 by 18.9 +/- 11 hr with HFO-A as compared with 64 +/- 6 hr using CMV, without any evidence of an increase in pulmonary complications. There were 17 complications in the nine CMV-treated infants; and four in the six HFO-A treated ones. We conclude that HFO-A, instituted early and used with a protocol designed for early reduction in FI02 requirements, demonstrates sufficient efficacy and safety to warrant further clinical trials in the routine management of infant RDS.

Evaluation Studies as Topic↗

Effect of graded erythrocythemia on cardiovascular and metabolic responses to exercise.

The effects of graded induced erythrocythemia on cardiovascular and metabolic responses to intense treadmill running were studied in four highly trained endurance runners. Three autologous infusions of 1 unit (U) whole blood (450 ml/U) were administered sequentially 2-7 days apart. Maximal O2 consumption (VO2max) increased from 5.04 l/min at control (C) to 5.24 l/min after 2 U (R2) and 5.38 l/min after 3 U (R3). Cardiac output during treadmill running at 91% control VO2max was 28.2 l/min at C, 29.8 l/min at R2, and 33.1 l/min at R3. Corresponding heart rates were unchanged, and stroke volume was increased at R3. Peak lactate concentration was reduced, and arterial acid-base status improved at R2 and R3 after standardized bouts of intense exercise. Arterial blood pressures and electrocardiograms during exercise were not affected by erythrocythemia. We conclude that the reinfusion of up to 3 U of autologous blood into highly trained endurance runners who have normal hematology does not adversely affect their cardiovascular response to maximal exercise. In addition, the increases in VO2max following reinfusion of 2 U, and again after 3 U, suggest that the aerobic power of the working muscles was not surpassed at these levels of erythrocythemia.

Acid-Base Equilibrium↗

Validation of noninvasive maximal cardiac output measurement.

Due to the invasiveness of direct techniques and problems that constrain the use of popular indirect techniques during very heavy (non-steady-state) exercise, measurements of maximal cardiac output are seldom included in studies of exercise. The acetylene-rebreathing technique is well-suited for maximal exercise; however, until recent technological advances, difficulties involved in collecting and measuring alveolar acetylene samples have restricted its use. We compared cardiac output values measured via the acetylene-rebreathing technique (QA) (modified for use with a mass spectrometer) and the dye-dilution technique (QD) at rest and during light to maximal exercise in six moderately active males. Although QA consistently underestimated QD, the two techniques showed a significant correlation of 0.87 throughout all levels of exercise. During maximal exercise, QA and QD values were not significantly different (24.7 and 26.7 l X min-1, respectively). Modifications in the QA technique that reduce potential sources of error were also examined. We conclude that the acetylene-rebreathing technique, modified for use with a mass spectrometer, is a simple and valid procedure for measuring maximal cardiac output.

Adult↗

High-frequency oscillation compared with standard ventilation in pulmonary injury model.

Hemorrhagic pulmonary edema was induced by intra-atrial infusion of 0.04--0.1 ml/kg of oleic acid into six anesthetized dogs. Gas exchange and cardiac outputs were then compared at identical mean airway pressures during randomized ventilation with either a volume-cycled ventilator with positive end-expiratory pressure (conventional positive-pressure ventilation, tidal volume 16--21 ml/kg, frequency 15--20 cycles/min) or a variable volume piston pump operating at 15 Hz (high-frequency oscillation). The fractional inspired oxygen concentration was maintained at 0.5 throughout. During 17 data sets matched for intratracheal mean airway pressures over a range of 7.5--27 cmH2O, measurements of systemic arterial pressure, arterial blood gas tensions, thermodilution cardiac outputs, and pulmonary arterial and capillary wedge pressures were identical (P less than 0.05) during ventilation with conventional positive-pressure ventilation and high-frequency oscillation. With both forms of ventilation, arterial oxygen tension progressively improved as mean airway pressure increased. In a shunt model of acute lung injury we were unable to show significant differences in oxygenation or cardiac output when high-frequency oscillation was compared with conventional positive-pressure ventilation with positive end-expiratory pressure at equivalent mean airway pressures.

Animals↗

Oxygenation during high-frequency ventilation compared with conventional mechanical ventilation in two models of lung injury.

Oxygenation and mean lung volume were investigated during high frequency oscillation (HFO) and conventional mechanical ventilation (CMV) in two models of lung disease and related to the lung mechanics of the lesions. Oleic acid (n = 10) or lung lavage (n = 12) pulmonary injury was induced in a series of rabbits. Each animal was alternately ventilated with HFO (15 Hz sinusoidal wave form) and CMV (flow generator I:E, 1:2; f, 30 breaths/min; VT, 10 to 15 ml/kg) at matched mean airway pressure. Pao2 was measured 5 minutes after onset of ventilation. In the lung lavage model Pao2 was significantly greater during HFO than CMV (Pao2 228 +/- 116 torr vs 71 +/- 42 torr) provided that mean airway pressure was greater than the distinct opening pressure characteristic of this lesion. In the oleic acid model oxygenation was again superior during HFO (Pao2 269 +/- 116 torr vs 110 +/- 83 torr), but only if HFO was preceded by a sustained inflation. Plethysmography in a subset of six rabbits from each group revealed that the improvements in oxygenation were associated with significantly higher mean lung volumes during HFO than CMV (58 +/- 30 ml vs 29 +/- 14 ml lung lavage model, 45 +/- 15 ml vs 30.9 +/- 13 ml on the oleic acid model). The importance of a sustained inflation in rapidly optimizing gas exchange during HFO but not CMV was demonstrated. A sustained inflation resulted in immediate and sustained increases in Pao2 (from 134 +/- 102 torr to 274 +/0 124 torr in the oleic acid model; from 115 +/- 105 torr to 291 +/- 143 torr in the lung lavage model) and mean lung volume (41.8 +/- 11 to 53.8 +/- 9.7 ml in the oleic acid model, 30.9 +/- 7.7 ml to 42.8 +/- 5 ml in the lung lavage model). It is suggested that in these two particular models of lung disease, HFO, when combined with a sustained inflation (to provide opening forces), can more fully exploit the pressure volume hysteresis of unstable lung units than CMV, thereby resulting in the larger mean lung volumes and better oxygenation observed during HFO.

Animals↗

Treatment of RDS by high-frequency oscillatory ventilation: a preliminary report.

The feasibility of high-frequency oscillatory ventilation was investigated in eight neonates with severe RDS. Low-volume, high-frequency flow oscillations were generated by a piston pump and delivered through standard endotracheal tubes. Oscillatory frequencies ranged from 8 to 20 Hz and mean airway pressure from 9 to 20 cm H2O. Heart rate, airway pressures, and arterial blood gases and blood pressure were monitored during both continuous positive pressure ventilation and HFO. During HFO mean PaCO2 was 44.0 +/- 4.8 mm Hg. During CPPV immediately prior to oscillation an FIO2 of 0.66 +/- 0.15 resulted in a PaO2 of 59.6 +/- 17.0 mm Hg. Oxygenation improved during HFO such that a mean FIO2 of only 0.41 +/- 0.11 was needed for similar oxygenation. Improvements in oxygenation correlated directly with increases in mean airway pressure. Based on an animal model the phasic pressure swings during HFO are estimated to be 5 to 7 cm H2O in the trachea, much less than conventional ventilation. We conclude that HFO shows great promise in the support of gas exchange in infants with RDS. The use of small phasic volume and pressure swings should minimize pulmonary barotrauma. HFO should also permit the use of lower inspired oxygen fractions.

Humans↗

Vagotomy reverses apnea induced by high-frequency oscillatory ventilation.

Apnea has been observed in both animals and patients during high-frequency oscillatory ventilation. The effects of vagotomy were studied during periods of oscillator-induced apnea in 11 pentobarbital-anesthetized dogs. The animals were intubated and breathing spontaneously. An arterial cannula was inserted for monitoring blood pressure and blood gases. Intratracheal airway pressure was measured, and respiratory activity was assessed using either an intrapleural catheter or esophageal balloon. The dogs then underwent high-frequency ventilation at 15 Hz. Apnea was induced by appropriate selection of volume displacement of the piston pump and the distal airway pressure in eucapnic animals. Segments of right and left vagus nerves were exposed in the neck, bathed in local anesthetic, and transected. Spontaneous ventilation resumed immediately in nine animals and could not be suppressed at the same CO2 partial pressure despite continuation of oscillation. We conclude that the apnea observed during high-frequency ventilation is mediated by active vagal inhibition of central respiratory activity and is usually reversed by vagotomy.

Animals↗

Effect of induced erythrocythemia on aerobic work capacity.

The aerobic work capacity of 11 highly trained runners was studied employing a double-blind design 1) before phlebotomy (C1), 2) following restoration of normocythemia (C2), 3) after a sham reinfusion of 50 ml of saline (sham), 4) following autologous reinfusion of approximately 900 ml of freeze-preserved blood (reinfusion), and 5) upon reestablishment of control hematologic levels after erythrocythemia (C3). There were no hematologic differences among C1, C2, sham, and C3, but following reinfusion, hemoglobin was significantly elevated (15.7-16.7 g . 100 ml-1). Maximum O2 consumption (VO2max) and running time to exhaustion were significantly increased 24 h postreinfusion (5.11-5.37 l . min-1 and 7.20-9.65 min, respectively) and 7 days postreinfusion. When sham preceded reinfusion, VO2 max and time to exhaustion were the same as control. However, 16 wk postreinfusion, despite the return to normal hematologic values, VO2max remained significantly above control levels at sham and C3. These findings indicate that there is a distinct increase in VO2max following induced erythrocythemia and suggest that oxygen transport limits maximal aerobic capacity.

Adult↗

Ventilation by high-frequency oscillation.

The effect of applying a high-frequency small-volume sinusoidal oscillation at the airway was investigated in anesthetized apneic beagle dogs (mean wt 11 kg, mean VDphys 6.6 +/- 0.6 ml/kg). Oscillations generated by a piston in a cylinder were transmitter to the lungs through an uncuffed endotracheal tube (4.5 mm ID, 6.0 mm OD), which allowed a substantial leak back through the vocal cords. A bias flow of fresh gas presented inspired air to the midtracheal level. The minimum distal airway pressure (measured at the end of the endotracheal tube) was maintained between 0 and 2 cmH2O. Peak airway pressures were 4-8 cmH2O. The optimal frequency for CO2 elimination was 15 Hz. Using volumes of 1.9 ml/kg (range 1.7-2.3) at this frequency the mean PaCO2 was 33.1 +/- 0.5 Torr. In four dogs breathing 100% O2 the PaO2 was 594 +/- 9 Torr during spontaneous ventilation and 580 +/- 9 Torr after 5 h of uninterrupted oscillation. In four experiments using room air the PaO2 was 95 +/- 5 Torr during spontaneous respiration and 106 +/- 1 Torr after 5 h of oscillation. In an additional seven studies there was no difference in mean cardiac output between oscillation and conventional mechanical ventilation. This study demonstrates that high-frequency small-volume oscillations can maintain gas exchange for many hours presumably by markedly enhancing the diffusivity of gases in the lung.

Animals↗