Osseointegration of composite calcium phosphate bioceramics.

The resistance of macroporous calcium phosphate ceramics to compressive strength generally is low and depends on, among other factors, porosity percentage and pore size. A compromise always is adopted between high porosity, required for a good integration, and mechanical strength, which increases with material density. We improved the strength of macroporous calcium phosphate ceramics of interconnected porosity by filling the pores with a highly soluble, self-setting calcium phosphate cement made of TCP and DCPD. Cylinders of the resulting material were implanted in sheep condyles and subjected to histological analysis after 20, 60, and 120 days. Microradiographs were made of the histological sections. The control material consisted of ceramic that had not been loaded with cement. Progressive ingrowth of bone into the ceramic pores occurred as the cement was degraded during the first implantation period. Marked degradation of the cement was apparent after 2 months, with fragmentation of the cement in most of the pores and the presence of bone tissue between the fragments. All the cement had been replaced by bone after 4 months. Some fragments of cement still were embedded in the newly formed bone. There was no significant difference between the integration of loaded and nonloaded ceramics. Filling the macroporous ceramic pores with a calcium phosphate cement significantly improved the mechanical strength of these ceramics without modifying their integration in the healing bone.

Animals↗

Accuracy and precision of in vivo bone mineral measurements in sheep using dual-energy X-ray absorptiometry.

We evaluated the precision and accuracy of in vivo measurements of spine bone mineral density (BMD) and bone mineral content (BMC) in five ewes using dual-energy X-ray absorptiometry (DXA, Lunar DPX-L). The short-term in vivo reproducibility expressed as the coefficient of variation (CV) varied from 0.9 to 1.6% for spine BMD and from 1 to 3.1% for spine BMC. The ex vivo measurements, performed in 20 cm of water to simulate soft tissue thickness, correlated closely with the in vivo measurements, yielding an r value of 0.98 and 0.97 for spine BMD and BMC, respectively. The accuracy was determined by comparing the total BMC of each vertebra measured in vivo with the corresponding ash weight. The correlation coefficient between the two measurements was r = 0.98, with an accuracy error of 5.6%. We concluded that the DXA allows a precise and accurate measurement of spine bone mineral in live ewes using the methodology designed for humans.

Absorptiometry, Photon↗

The point of view of the veterinary surgeon: bone and fracture.

It is important to understand the biomechanics of fractures if the morphological characteristics of fracture, fracture treatment and fracture healing are to be understood. Because of the mechanical properties of bone, which is stronger in compression than in tension, a fracture line is initiated perpendicular to the direction of tension or in shear. The mechanical properties of bone are also time-dependent (viscoelasticity). Subsequently, when the load is applied at a higher load range, a greater amount of energy is stored within the bone, resulting in a more severe fracture (high energy fractures). There are five types of fracture: tension, compression, torque, bending, and shear, with typical morphologies: transverse fractures in tension, fracture line at 45 degrees to the long axis of the bone in compression, spiral fracture in torsion, combined transverse and butterfly fracture in bending, shear line when the overload is applied eccentrically. These different morphological types are shown on radiographs.

Animals↗

Histological integration of allogeneic cancellous bone tissue treated by supercritical CO2 implanted in sheep bones.

UNLABELLED: Different chemical or physical methods of bone processing have been developed to decrease the antigenicity of allogeneic bone which may delay or prevent graft integration. We have developed a method based on delipidation and deproteination of the bone with a supercritical fluid and hydrogen peroxide. Cylinders of cancellous allogeneic bone treated in this way were implanted for four weeks, four months or eight months in holes drilled in sheep condyles or tibial plateau. Histological sections were then processed and analysed qualitatively and quantitatively using an image analysis software coupled to a light microscope. Measurements were made of the trabecular bone surface (BS/TS), the relative osteoid surface (OS/BS), the active osteoid surface (OS/BS), active resorption surface (Oc.S/BS) and the relative surface of newly formed bone. After four weeks, the control cylinders (non-treated allogeneic bone) had been invaded by cellular tissue composed of lymphocytes and plasmocytes surrounding remnants of the donor bone marrow tissue. The processed cylinders showed osteoid apposition at the surface of their external trabeculae. The trabecular bone and osteoid surfaces were significantly higher in the processed bone sections than in the control bone sections. After four months, most of the control material had been osteolysed and replaced by connective tissue containing lymphocyte islets, while the processed materials showed a large amount of bone synthesized at the surface of implant trabeculae which appeared fragmented and disseminated within the newly formed bone. All the histomorphometric parameters measured were significantly different from those of the control. By eight months, most of the control material had been totally osteolysed with very little bone ingrown in the implantation site. Only one control implant had been integrated. The processed cylinders were difficult to discern from the bone in which they were implanted. The parameters measured on the processed cylinders were significantly higher than those measured on the control sections. IN CONCLUSION: the treatment applied to the bone enhanced allogeneic bone integration and could provide a new kind of tissue treatment for bone banking.

Animals↗

Prevention of surgical infections in dogs with a single intravenous injection of marbofloxacin: an experimental model.

Eighteen healthy beagle dogs of both sexes were each given 0, 2 or 4 mg/kg marbofloxacin intravenously before the subcutaneous implantation of a silicon tissue cage. Two millilitres of a suspension containing 1.3 x 10(4) colony forming units (CFU)/ml of Staphylococcus intermedius were then injected into the cage 15 minutes after the intravenous injection. The dogs were clinically assessed immediately, and then two, four, eight and 24 hours after the challenge. Samples of inflammatory fluid were harvested at the same times in order to count staphylococci and to assay marbofloxacin concentrations. Blood samples were taken in order to assay plasma marbofloxacin levels. The staphylococcal counts were lower in both treated groups than in untreated dogs (P < 0.01). All the clinical criteria were similar in the three groups. The concentration of marbofloxacin was similar in plasma and inflammatory fluid. Both doses were well tolerated and no adverse reactions were observed.

Animals↗

In vivo quantification of muscle damage in dogs after general anaesthesia with halothane and propofol.

Muscle damage in dogs anaesthetised with halothane and propofol was quantified by measurement of the area under the curve of plasma creatine kinase (CK) versus time. Plasma CK remained unchanged during anaesthesia for two and a half and five hours. Following halothane anaesthesia of dogs (resting on one side directly on the surgical table or on cushions, and with or without rotation of the body every 30 minutes), plasma CK was elevated in some animals to 10,000 U/litre by the 12th hour (baseline value < or = 100 u/litre), whereas it remained almost unchanged in other animals. Plasma CK then returned to reference values on day 2 or 3. The mean equivalent of muscle damaged ranged from 0.6 to 0.9 g/kg bodyweight. No muscle damage could be demonstrated in animals anaesthetised with propofol. It is therefore concluded that plasma CK should not be used as a diagnostic aid following halothane anaesthesia because of false positives due to the halothane anaesthesia itself and that propofol is best suited for the investigation of muscle damage due to surgical procedures.

Anesthesia, General↗

Plasma concentrations and therapeutic efficacy of phenylbutazone and flunixin meglumine in the horse: pharmacokinetic/pharmacodynamic modelling.

The purpose of the present study was to establish in the horse the relationship between plasma concentration profiles of phenylbutazone (PBZ) and flunixin meglumine (FM) and their pharmacological effects in order to build a predictive pharmacokinetic/pharmacodynamic (PK/PD) model. In five horses, an experimental arthritis was induced by injecting Freund's adjuvant into a carpal joint. PBZ (4 mg/kg) and FM (1 mg/kg) were injected by the intravenous route as a single intravenous dose in two different trials. Five pharmacodynamic end-points were regularly measured after test article injection using standardized procedures: local skin temperature, stride length, the rest angle flexion and the maximal carpal flexion of the injured leg and circumference of the inflamed joint. Plasma drug concentrations and pharmacodynamic data were analysed according to an integrated PK/PD model; for the stride length, the PBZ EC50, i.e. the plasma concentration for which half the maximum effect could be obtained, was 3.6 +/- 2.2 micrograms/ml and the maximum potential effect was 10.7 +/- 9.4% above the control value. For FM, the corresponding values were 0.93 +/- 0.35 micrograms/ml and 16.3 +/- 4.6%. EC50 values for rest angle flexion and local skin temperature were similar to that obtained for stride length. Maximal carpal flexion was an unreliable end-point, and circumference of the joint did not display significant response to the drugs. Using these experimental parameters, a dose-effect relationship was simulated for both drugs; it was shown for PBZ that the model predicts an absence of effect for a 1 mg/kg dose and a maximum effect at about 2 mg/kg; at higher PBZ doses, the maximum effect was not modified, but its duration was increased from 8 h with a 2 mg/kg dose to about 24 h with an 8 mg/kg dose. For FM the model predicts that a dose of 0.5 mg/kg will be without significant effect, whereas a 1 mg/kg dose allows a nearly maximal effect with a return to the control value after a delay of 16 h. A 2 mg/kg dose allows the effect to be maintained for 24 h. It is concluded that PK/PD is a tool of potential value for the preclinical screening of a dosage regimen.

Animals↗

Osseointegration of macroporous calcium phosphate ceramics having a different chemical composition.

Calcium phosphate macroporous ceramics are biocompatible for bone surgery. Their osseointegration is, however, sometimes very poor. To measure the effect of the calcium phosphate content of the ceramic on its osseointegration, macroporous ceramics, differing in their chemical composition, were implanted into sheep femurs. The ceramics were composed of different percentages of hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP). All other characteristics were the same. Results were assessed histologically with image analysis and showed significant differences in the amount of bone formed at the contact of the different ceramics. Ceramics containing beta-TCP induced better osseointegration than pure HA ceramics.

Animals↗

[Hybrid substitute materials for bone. Initial results and perspectives].

Hybrid materials for use as bone substitutes are composed of a synthetic substance to which autologous osteogenic cells are bound. Identification of osteogenic stem cells among bone marrow stromal cells was followed by the demonstration that a host of growth factors, hormones, and cytokines have effects on cultured osteoblasts. Porous ceramics have been developed as vectors for osteogenic cells previously grown in vitro. Porous hydroxyapatite beads bearing stromal cells were used to fill experimental ulnar defects in dogs. The cells were first grown on flat supports then on the three-dimensional hydroxyapatite network. Invasion by histologically identifiable bone tissue was seen in the stroma cell-bearing implants but not in control implants without stromal cells. Materials containing osteogenic cells may prove extremely useful since bone substitutes including hydroxyapatite ceramics are implanted in sites where osteogenic cells are scarce.

Animals↗

Intra- vs intermuscular injections in swine.

In order to determine the exact localization (intra- vs intermuscular) in which a drug is injected when administered by a so-called intramuscular injection technique, a radiopaque test article (2 ml) was injected into the cervical musculature (2 sites), the loins and the gluteal mass in anaesthesized pigs. Immediately after this, the pigs were euthanized and deep-frozen. Then they were cut into slices, which were X-rayed to determine the exact localization of the test material. Semi-quantitative scores were given to each injection site according to the amount of test article found in or out of muscle mass and also to the absence or the presence of test article subcutaneously. The loins area obtained the highest score for intramuscular location, but in this site, injections were almost always followed by a flowing back of the test article to the subcutaneous' area. It was shown that an injection in the neck perpendicular to the skin surface just behind the base of the ear was the most appropriate site for intramuscular injection in pigs.

Analysis of Variance↗

Bone cutting.

Bone cutting has always been a problem for surgeons because bone is a hard living material, and many osteotomes are still very crude tools. Technical improvement of these surgical tools has first been their motorization. Studies of the bone cutting process have indicated better features for conventional tools. Several non-conventional osteotomes, particularly ultrasonic osteotomes are described. Some studies on the possible use of lasers for bone cutting are also reported. Use of a pressurised water jet is also briefly examined. Despite their advantages, non-conventional tools still require improvement if they are to be used by surgeons.

Bone and Bones↗

Distribution of material injected intramuscularly in dogs.

A radiopaque marker was injected, using needles of various lengths, into the cervical musculature, the lumbar epaxial musculature, and the cranial and caudal muscular masses of the thighs of anesthetized dogs. After this procedure, the dogs were euthanatized and deep-frozen. The bodies were then sectioned, and the slices were radiographed to determine the fate of the injected material. Material that was injected into the neck or caudal region of the thigh was determined to be located in the muscle bellies or dispensed throughout the intermuscular fascial sheaths. In contrast, material injected into the lumbar area and cranial region of the thigh was located entirely in the muscle bellies. It was concluded that the best sites for injection in dogs are the lumbar epaxial musculature or the quadriceps femoris muscle when IM administration is imperative.

Animals↗

Diurnal and episodic variations of plasma hydrocortisone concentrations in horses.

Using a specific high-performance liquid chromatographic technique, plasma hydrocortisone values were measured hourly in 6 horses and every 10 minutes in 4 horses over 24 hours. Both circadian and episodic variation was observed. The mean plasma hydrocortisone concentration was a maximum of 58.8 +/- 9.54 ng/ml at 9.19 +/- 0.59 hr and a minimum of 27.85 +/- 6.85 g/ml at 21.19 +/- 0.59 hr. The number of episodes of secretion was 10.0 +/- 1.41; the mean amplitude and duration of peak were 26.21 +/- 3.71 ng/ml and 105.25 +/- 21.24 min respectively.

Animals↗

Hydrocortisone secretion: production rate and pulse characterization by numerical deconvolution.

Based on serial blood sampling over 24 h, hydrocortisone was shown to be secreted episodically in the horse. The purpose of the present experiment was to characterize peaks and troughs by analyzing the instantaneous secretion rate profile obtained by a deconvolution technique rather than from the plasma concentration time profile. Kinetic parameters of hydrocortisone were determined following intravenous bolus and intravenous perfusion of hydrocortisone. Stationary and nonlinearity of hydrocortisone disposition were demonstrated. With the use of clearance values calculated from constant perfusion administration, the 24-h hydrocortisone production rate was estimated at 0.46 +/- 0.08 mg.kg-1.24 h-1. The instantaneous secretory profile was reconstituted by deconvoluting the plasma concentration profile using structural parameters determined from the bolus hydrocortisone administration. When this secretory profile was subjected to a pulse analysis program, the number of detected peaks was found to be 17.25 +/- 1.26 and the mean peak duration 34.01 +/- 5.52 min. The total duration of secretory activity was estimated at 582.5 +/- 63.97 min. By comparison, when the plasma concentration profile was analyzed directly, the number of peaks was only 10.0 +/- 1.41 but their mean duration was much longer, i.e., 105.25 +/- 21.24 min. The origin of these differences and the advantages and limits of deconvolution analysis are discussed.

Animals↗

Pharmacokinetics of methylprednisolone succinate, methylprednisolone, and lidocaine in the normal dog and during hemorrhagic shock.

Pharmacokinetics of methylprednisolone succinate and methylprednisolone following methylprednisolone sodium succinate administration were studied in five dogs under normal conditions and then during a severe hemorrhagic shock. In order to evaluate hepatic blood flow, lidocaine clearance was simultaneously measured. In the normal state, the clearance of methylprednisolone succinate was 1.64 +/- 0.499 L/h/kg and its half-life was 15.33 +/- 3.84 min. The systemic availability of methylprednisolone from methylprednisolone succinate was 59.9 +/- 8.3%, and the maximal methylprednisolone concentration was observed after a delay of 7.68 +/- 6.31 min. Using a reservoir technique in anesthetized dogs, severe hemorrhagic shock was obtained. Changes in lidocaine clearance indicated a subsequent reduction of hepatic blood flow. The clearance of methylprednisolone succinate decreased to 0.488 +/- 0.240 L/kg/h, and the half-life increased to 40.66 +/- 23.48 min. The exact availability of methylprednisolone from methylprednisolone succinate during shock was not calculable because methylprednisolone kinetics were time dependent. The plasma methylprednisolone concentration was relatively high and persistent during the shock. It was concluded that methylprednisolone sodium succinate is a prodrug which can be released in sufficient quantities as its active moiety (i.e., methylprednisolone) during severe hemorrhagic shock in the dog. In addition, after a single intravenous administration, the slow process of methylprednisolone elimination may give sustained methylprednisolone concentrations for several hours.

Animals↗

Synovial fluid and plasma kinetics of methylprednisolone and methylprednisolone acetate in horses following intra-articular administration of methylprednisolone acetate.

Synovial fluid and plasma kinetics of methylprednisolone acetate (MPA) and methylprednisolone (MP) after a single intra-articular administration of MPA at a therapeutic dose (111 mg in toto) was measured in five horses. MPA was detected in synovial fluid for two to six days post injection and MP, which results from synovial MPA hydrolysis, was present in pharmacologically significant concentrations for 4.8 to 39 days, depending on the horse. MPA synovial concentration was maximal (289 +/- 284 micrograms/ml) at the first sampling time (2 h after administration) and MP synovial concentration was maximal (from 58.9 to 379.5 micrograms/ml) at the first or second sampling time (2 to 10 h after administration). Thereafter, both MP and MPA declined rapidly. From time of administration to about five days later, MP synovial fluid concentration fell progressively with a half-time of 9.95 h. Subsequently, the MP synovial fluid concentration decreased more slowly with an apparent half-time of 115 h. During the first 24 h following MPA administration, trace amounts of MP (less than 5 ng/ml) were detected in plasma. Plasma hydrocortisone levels were depressed for three to four days after administration but adrenal responsiveness to adrenocorticotrophic hormone tests remained unaffected.

Adrenal Glands↗

Exaggerated femoral anteversion and acetabular development: experimental study in growing dogs.

Femoral excessive anteversion caused by femoral osteotomy in growing dogs is an accurate dynamic model of experimental acetabular dysplasia. Radiographic and CT scan examinations were performed throughout the growing period. Evolution showed an incomplete femoral detorsion. It induced acetabular developmental modification leading to an anterior and superior acetabular dysplasia. At the end of the growing period, hips were not dislocated, but signs of femoral and acetabular osteoarthritis were obvious, which shows the importance of mechanical force modification in the creation of experimental osteoarthritis. The links between hip osteoarthritis and exaggerated femoral anteversion are discussed. Might acetabular dysplasia be secondary to femoral anteversion, which could justify a corrective osteotomy during childhood? Our experiment leads to a better comprehension of this phenomenon.

Acetabulum↗