[Methods for evaluation of perimodiolar ci electrode arrays in human temporal bones].

BACKGROUND: Cochlear implants (CI) are the established treatment for cochlear deafness. Recently, indications for cochlear implantation have been expanded to include severely hearing-impaired patients. The use of bilateral implants seems to provide additional benefit. Moreover, new electrode designs, i. e. perimodiolar electrode arrays, aim at improving benefit for patients. However, in addition to providing functional improvements, modern electrode array development must also address safety aspects, because damage to the cochlear morphology (especially the osseous spiral lamina) may lead to degeneration of residual neuronal structures and bony obliteration or scarring within the cochlear ducts. METHODS: Therefore, insertion trauma of the newly developed electrode arrays in human temporal bones must be evaluated before applied to patients. Several methods for testing electrode location and intracochlear trauma are described. RESULTS: Combining cross-sectional imaging, histological analysis and elements of risk-assessment valid information about trauma and possible consequences for use in patients can be determined, based on our experience in 57 temporal bones. CONCLUSIONS: Following our results, safety studies with prototype electrode arrays should, in addition to radiological examination, always include careful histomorphological evaluation.

Adult↗

[The influence of insertion depth on the preservation of residual hearing after cochlear implantation].

BACKGROUND: Cochlear implantation may be indicated in patients with bilateral severe sensory hearing loss. Patients with minimal residual hearing have more benefit from cochlear implantation than from optimal fitted hearing aids. However, it has to be considered that inner ear structures might be damaged during electrode insertion. METHODS: We analysed the influence of insertion depth on the preservation of residual hearing in 47 cochlear implant patients (type of implant: Nucleus 22 M or 24 M) by using the pure tone audiometry. Frequency-specific analyses of pre- and postoperative audiograms on the implanted side were performed, evaluating only frequencies above 500 Hz. The insertion depth was documented by stiffening rings outside the cochlea. RESULTS: Residual hearing was more obtained in cases with complete insertion of the electrode array than in those cases with incomplete insertion. In the frequencies 1000 and 4000 Hz these results are significant. CONCLUSION: In our opinion, the perceived resistance producing intracochlear damages and preventing the complete electrode-insertion at the same time is an explanation for the significantly poorer results of the patients with incomplete insertion.

Audiometry, Pure-Tone↗

[The freiburg incision for cochlear implantation -- initial results].

BACKGROUND: Cochlear implant surgery is a well standardized therapy for rehabilitation of congenital or acquired deafness at all ages. Mastoidectomy, posterior tympanotomy, cochleostomy and electrode insertion are performed consistently worldwide. Recently newly developed types of incision are taken into account. In our experience over more than 15 years the extended endaural incision has proven to be reliable with a low complication rate. OBJECTIVE: To evaluate a modified retroauricular incision for clinical use and complication rate in cochlear implant surgery with devices of different manufacturers. MATERIAL AND METHODS: We performed a prospective analysis of cochlear implant surgeries between 03/2003 and 03/2004. In all cases a modified retroauricular incision was used. Necessary adaptations of incision, depending on the device used, and postoperative complications were evaluated. RESULTS: In 76 ears a retroauricular incision was performed. Depending on the shape and size of receiver/stimulator an extension of the incision was necessary. The mean observation time was 6.3 months. Intra- or postoperative complications were not observed. In one case a skin dehiscence following trauma 28 days after surgery was reported without dehiscence of fascia or implant failure with uneventful healing after secondary suture. CONCLUSIONS: With regard to the results with the extended endaural incision the modified retroauricular incision allows a safe access for cochlear implant surgery. Observation of long term results and outcomes in revision surgery is mandatory.

Adolescent↗

[Endoscopic assisted endoluminal stapler-diverticulotomy of Zenker diverticulum].

INTRODUCTION: One of the advantages of endoluminal diverticolotomy in Zenker's diverticulum with the staple is the possibility of early rehabilitation. As the stapler allows to close the cut wound margins of the diverticulum threshold simultaneously with a clip suture, the patient can start oral food intake as early as 24 hours after surgery. The overview for the surgeon for correct placement of the clip device is limited due to the physiological narrowness of the pharyngeal tube. PATIENTS AND METHODS: We reduced the danger of malplacement by placing a temporary stomach tube as well as endoscopic control of the position of the stapler at the diverticulum threshold. RESULTS: 61 patients with Zenker's diverticulum stage Brombart I - IV have been successfully treated with this surgery technique since 1998. In two other patients a transcervical diverticulotomy was done because the diverticulum threshold could not be exposed clearly with the spread laryngoscope. In 10 patients a clinically symptomatical recurrent diverticulum (Brombart stage II) could be safely removed by a repeated endoscopically assisted stapler diverticulotomy. CONCLUSION: The advanced endoscopically assisted endoluminal stapler diverticulotomy in Zenker's diverticulum is convenient for the patient allowing prompt food intake and showing low morbidity and no mortality.

Adult↗

Influence of ionizing radiation on nucleus 24 cochlear implants.

HYPOTHESIS: To evaluate the influence of conventional or hyperfractionated radiotherapy on Nucleus CI24M or CI24R(CS) implant systems. BACKGROUND: As a consequence of more than 70,000 cochlear implant recipients worldwide, the potential need for radiotherapy is an issue requiring consideration by both implantees and implantation centers. Conditions requiring radiotherapy of the head may include head, neck, or brain tumors. METHODS: The study examines the effect of ionizing radiation on cochlear implant function. The implanted devices examined were the Nucleus CI24M and Nucleus CI24R(CS). In a modeled study, two implants of each type were treated with fraction schemes most frequently used in clinical routine (e.g., conventional fractionation [total dose, 120 Gy] and hyperfractionation [total dose, 116 Gy]). Parameters quantified were the implant output amplitude changes at high and low current level (current levels 255 and 100, respectively), the charge balance of the biphasic pulse, and the accuracy of the impedance telemetry function. RESULTS: Within the clinically relevant dose range (< 80 Gy), implant function in all four devices was normal. Failure occurred in one Nucleus CI24R(CS) device treated with hyperfractionation. A dramatic drop in the output amplitude at 106 Gy was observed, and the impedance measurement failed at a total dose of 111 Gy. CONCLUSION: The results suggest that conventional or hyperfractionated radiotherapy can be applied safely at Nucleus CI24M or CI24R(CS) implant systems in a patient-like setting. Therefore, the authors propose that the results of the study can be applicable in clinical practice.

Cochlear Implants↗

[Current developments in cochlear implantation].

Over the last 20 years, cochlear implantation has become a well accepted treatment in patients suffering from hearing loss or congenital deafness. Results have been impressive,and indications for a cochlear implant have been extended continuously. Thanks to a sophisticated diagnostic procedure, optimization of the surgical technique, and the progression of interdisciplinary cooperation in the field of rehabilitation, the acceptance of cochlear implantation is growing significantly. The manufacturers of the devices are making great efforts to miniaturize the external components of the system, and new developments in electrode arrays, combined with new speech coding strategies, result in better speech understanding. The new developments in electrode design, however, are not necessarily improvements over recent years. Nevertheless, a very well functioning network of physicians, scientists, and manufacturers has acted and reacted in an outstanding manner to identify possible causes of post-implantation meningitis, have taken immediate counter measures and presented possibilities of prevention.

Cochlear Implantation↗

[Navigation-controlled cochleostomy. Is an improvement in the quality of results for cochlear implant surgery possible?].

BACKGROUND: The correct positioning of the electrode, which is the limiting factor for the functional integrity of cochlear implants, is decisively influenced by the cochleostomy. Localisation and form of the drilling canal have been solely defined by the surgeon during the operation and an enlargement of the drilling canal is often necessary. Thanks to the improved resolution of new slice imaging techniques, computed tomography allows an exactly defined optimal point for cochleostomy. MATERIAL AND METHODS: In a cadaver study, we examined whether the target defined with computed tomography can be reached in a reproducible way with the help of navigated computer assisted surgery. We chose titanium screw markers as the gold standard for referencing. RESULTS: There was a real deviation of 1.6 mm in the target field. Thus, in a cochleostomy with a diameter of 0.5 mm the goal was not reached in a reproducible way. With this deviation a target of 2.56 mm(2) is defined. CONCLUSIONS: A target assessed by navigation is better than one reached without navigation in view of reproducibility and accuracy. With further technical progress navigated cochleostomy will be possible.

Cadaver↗

[Does computer-aided navigation of endonasal sinus surgery improve process quality and outcome quality?].

BACKGROUND: Ever since navigation technology was introduced into endonasal surgery, its impact on process and result of surgery has been debated. In this respect, factors of investment costs and additional costs for time exposure will be discussed as well. PATIENTS AND METHODS: In a retrospective analysis of quality assurance, the results of endonasal surgery by surgeons of different experience in 56 patients were evaluated. Preparation time, preoperative setup time as well as time of actual surgery were analysed and compared with possible indications for navigation. RESULTS: From our analysis a classification resulted dividing the indications for navigation into the following four different categories: redundant, reasonable, helpful, necessary. Navigation was redundant when it was dispensable and did not result in a clear improvement of process or outcome quality. Navigation has been proved reasonable when it helped to obtain additional information for improving process quality. It was considered helpful when the information obtained by navigation had an influence at least on the course and/or result of surgery. Navigation was necessary from the surgeon's point of view when the intervention in regard to the benefit-risk-ratio could not be justified without navigation, or only intraoperative slice imaging would allow surgery. CONCLUSION: Not only redundant, but also facultative and obligatory indications for navigation in endonasal surgery result from careful consideration of the risk-benefit-cost ratio. In standardized endonasal sinus surgery, like infundibulotomy or ethmoidectomy, however, navigation can be a hindrance to process quality and does not result in any advantage for outcome quality.

Adult↗

[Results with the Contour cochlear implant in patients with cochlear otosclerosis].

BACKGROUND: Results after cochlear implant surgery may be complicated by postoperative facial nerve stimulation. Aim of the study presented was to evaluate postoperative results in implanting the straight Nucleus electrode array and the preformed Contour array in patients with deafness due to cochlear otosclerosis. METHODS: A retrospective analysis of intra- and postoperative reports of all patients with cochlear otosclerosis was carried out. Results with the Nucleus straight electrode array and the Contour array were compared with regard to postoperative facial nerve stimulation. RESULTS AND CONCLUSION: None of the Contour patients (n = 7) presented with postoperative facial nerve stimulation. This is in contrast to the majority (4 of 6) of patients being implanted with the straight electrode array. Our results indicate that the use of the Contour array is advantageous in patients being at risk for facial nerve stimulation. In addition intraoperative reports suggest a more reliable insertion of the Contour electrode array in cochlear otosclerosis with partial obliteration.

Cochlear Implants↗

[Caloric stimulation of the vestibular organ after cochlear implant surgery].

BACKGROUND: Alterations of the vestibular organ after intracochlear insertion of the electrode array in cochlear implant (CI) surgery are estimated in the literature to be more than 30 % . By performing a most atraumatic electrode insertion following the "soft surgery technique" as described by Lehnhardt , the risk of postoperative vestibular dysfunction should be minimised. METHODS: In the present study we compared pre- and postoperative results of the caloric stimulation test in cochlear implant patients and analysed the influence of untimely opening of the perilymphatic space under cochleostomy. In addition we used a non-validated questionnaire, asking for continuous postoperative vertigo after cochlear implant surgery. RESULTS: From patients with preoperative normal or hyperfunction on the implanted ear (n = 32) approximately 16 % showed a hypofunction or nonfunction on the implanted side postoperatively, independent of the technique of the cochleostomy. Only 12 % (n = 98) of the patients who were without vestibular problems preoperatively described postoperative vertigo longer than two days in the questionnaires. CONCLUSIONS: Although we found no significant difference regarding the influence of the technique of the cochleostomy on the preservation of vestibular function, we conclude that the concept of an atraumatic electrode insertion reduces the risk of vestibular dysfunction after CI-surgery.

Adolescent↗

[Identification of two heterozygous mutations in the SLC26A4/PDS gene in a family with Pendred-syndrome].

BACKGROUND: Pendred-syndrome is an autosomal recessive disease that is classically characterised by sensorineural hearing loss and enlargement of the thyroid gland. The gene SLC26A4/PDS for the pendred-syndrome has been localised by linkage analysis on chromosome 7q31. This protein is expressed in the inner ear, thyroid gland, kidney and placenta. Functional analysis in Xenopus laevis oocytes revealed that it acts as an iodide/chloride and chloride/formate exchanger. METHOD: Each of the exons and flanking splice regions of the SLC26A4/PDS gene was analysed by direct sequencing. RESULTS: In the involved family two heterozygous mutations could be detected which results by combination in hearing loss and deafness. CONCLUSION: By evidences of familial background in hearing loss and thyroid disorder it is reasonable to analyse the PDS gene for mutation to have early the possibility for medical care of linguistic development through hearing aid or CI-implantation.

Child↗

[Obliterated cochlea in Cogan's syndrome -- implications for cochlear implant surgery].

BACKGROUND: Acute, often bilateral deafness in Cogan's syndrome or other autoimmune diseases is caused by autoimmune mediated inflammatory attack on the membranous labyrinth. Auditory rehabilitation in case of bilateral deafness can be achieved by cochlear implant surgery. METHODS: A retrospective analysis of all patients suffering from Cogan's syndrome that had received a cochlear implant, was carried out. RESULTS: 6 of 295 adult patients (2.6 %) that had received a cochlear implant, had become deaf due to Cogan's syndrome. Partial obliteration or ossifikation was encountered in all cases and influenced surgical procedure. In one case a fibrous obliteration of the scala tympani was found 8 weeks after acute onset of complete deafness. CONCLUSIONS: The course of obliteration is unknown. With regard to our results a fibrous obliteration may occur as early as 8 weeks after complete deafness. This has to be considered in counseling of patients. Only early cochlear implant surgery facilitates best possible rehabilitation results.

Adult↗

[Electrophysiologic examinations in low frequency hearing impairment: clinical and prognostic aspects].

INTRODUCTION: Low-frequency hearing impairment (LFHI) is mainly associated to endolymphatic hydrops and shows a high variety of possible outcomes. Electrophysiologic examinations are widely recommended in diagnostics of LFHI, wheras up to now no data exist about the prognostic value of these examinations in a conservative therapeutic regimen. METHODS: In a quality assessment, we retrospectively evaluated the records of 90 patients, and performed an audiometric follow-up for analysis of long-time hearing data. All patients had undergone diagnostic electrocochleographic examination (ECochG) and then had been treated with rheologic infusions, followed by dehydrating infusions in patients lacking complete remission. The results of both therapeutic strategies and of long-time results were correlated to electrophysiologic findings. RESULTS: The prognosis of LFHI is significantly reflected by pretherapeutic electrocochleographic data. All significant parameters were associated to compound action potential (CAP) whereas parameters associated to cochlear microphonics (CM) did not include any utilizable prognostic value. In patients with a good outcome, the latency of CAP complex was significantly shorter, and the width of CAP complex significantly smaller than in patients with poor hearing outcome after rheologic and after dehydrating therapy and in long time assessment. The relation of summating potential (SP) und CAP was significantly smaller when the outcome was sufficient or good for either therapy and in long time analysis. Steep CAP-input-output-curves were associated to insufficient outcome after rheologic therapy and in long time assessment, but not for dehydrating therapy. CONCLUSIONS: The results indicate that ECochG is of significant prognostic value concerning hearing outcome after conservative therapy in patients suffering from LFHI. It can help the physician to counsel the patient and perform an effective management of the disease. We conclude that ECochG should be performed before the onset of therapy, including collection of SP and CAP data whereas CM parameters may be omitted.

Action Potentials↗

[Evaluation of the insertion-trauma of the Nucleus Contour Advance electrode-array in a human temporal bone model].

BACKGROUND: The development of intracochlear electrode arrays is aiming at a placement close to the modiolus with an insertion as atraumatic as possible. A new perimodiolar electrode model the Nucleus Contour Advance was to be evaluated regarding the possible intracochlear trauma. METHODS: The implantation of the Contour Advance electrode was performed in 11 frozen native temporal bones. Beneath a regular insertion in 5 temporal bones in 6 cases the insertion was carried out using the "advance-off-stylett" technique with a fixed stylett. The temporal bones were embedded in metacrylate based resin for histomorphological evaluation. The evaluation was performed regarding to the intracochlear placement close to the modiolus and the damage to intracochlear fine structures (basilar membrane, osseus spiral lamina). RESULTS: In 2 out of 11 cases we found a perforation from the scala tympani to the scala vestibuli independent of the insertion-technique. A severe intracochlear trauma was observed in one case with fracture of osseus spiral lamina using the AOS-technique. A close position to the modiolus could be achieved by insertion the scala tympani without perforation of the basilar membrane. CONCLUSIONS: The Nucleus Contour Advance electrode array showed minimal trauma in human temporal bones by using a standard insertion technique. By using the freehand AOS-technique a severe cochlear trauma is possible. Therefore further development in electrode design and the use of an insertion-tool is recommended.

Basilar Membrane↗

Imaging procedures in cochlear implant patients--evaluation of different radiological techniques.

The purpose of this study was to evaluate the feasibility and usability of different radiologic methods (single-slice computed tomography (CT), multi-slice CT and rotational tomography (RT)) for assessment of the position of cochlear implant electrodes. Cochlear implants in an isolated human temporal bone and in a complete formalin-fixed cadaver head were examined and the electrode position was determined. Subsequently, the labyrinth bone was isolated out of the cadaver head and histologically examined to compare the results of histology with imaging. Single-slice CT reliably identifies the electrode inside the human cochlea; however, due to the technically based large electrode artifact its position inside the cochlear spaces (e.g. electrode position in scala tympani or scala vestibuli) cannot be detected. Multi-slice CT of the cadaver head also showed artifacts that complicate the assessment of electrode position. Using RT the electrode artifact is small and therefore the electrode position within the cochlear spaces, scala tympani versus scala vestibuli, can be assessed. This technique was also applicable in a complete cadaver head, which is in contrast with former studies. In conclusion, CT allows the identification of electrode arrays inside the human cochlea. Multi-slice CT permits a much more precise depiction of the electrode inside the cochlea. RT alone has minimized electrode artifacts to a high extent and permits the assessment of the electrode position within the scala tympani or scala vestibuli. As RT was performed successfully in a complete cadaver head, further studies for evaluation of the intracochlear electrode position can now be performed in patients.

Angiography, Digital Subtraction↗

The Nucleus Contour electrode array: a radiological and histological study.

OBJECTIVES: To evaluate the handling and insertion trauma of the recently developed Nucleus perimodiolar Contour electrode array (Cochlear Ltd., Pty, Lane Cove, New South Wales, Australia) in human temporal bones compared with the Nucleus standard straight electrode array. STUDY DESIGN: E-perimental control group. METHODS: Twenty-nine fresh-frozen bones were implanted with different electrode arrays by an experienced cochlear implant surgeon, and evaluated both radiologically and histologically. RESULTS: Intracochlear insertion of the standard Nucleus straight electrode array was found to be atraumatic, confirming previous findings in the literature. Insertion of the Nucleus Contour electrode array resulted in instances of localized basilar membrane penetration causing the electrode array to move from the scala tympani into the scala vestibuli. However, this trauma did not result in any observable damage to the osseous spiral lamina or the modiolus. Basilar membrane penetration was observed in six of eight cochlear bones when a standard cochleostomy size (approximately 0.8 mm) and site (anterior and superior to the round window) were used. However, when the surgical technique was modified to use a slightly larger cochleostomy ( approximately 1.8 mm) situated closer to the round window and employ a partial stylet withdrawal technique during electrode insertion, the frequency of penetrations was restricted to two of seven bones. This trauma rate is comparable to that observed with other cochlear implants designs. CONCLUSIONS: Following our results, the design of the Nucleus Contour electrode appears to fulfill the safety requirements for an intracochlear electrode array, provided that the surgical insertion technique is modified in the manner outlined.

Basilar Membrane↗

Cochlear structures after implantation of a perimodiolar electrode array.

OBJECTIVE: A perimodiolar prototype electrode array has been evaluated on 12 human temporal bone specimens. To achieve modiolar proximity, a fine Teflon positioner is attached to the tip and base of a conventional Nucleus 22 electrode array. METHODS: Intracochlear electrode position was examined by macroscopic preparation and confirmed by a cochlear view x-ray after insertion into human temporal bones. The temporal bones were examined with light microscopy for intracochlear trauma after insertion, explantation, and re-implantation of the perimodiolar array. RESULTS: Macroscopic preparation and x-ray confirmed close proximity of the intracochlear electrodes to the modiolar wall. In some bones, electrode insertion and positioning was performed without significant damage to intracochlear structures, but explantation caused varying degrees of trauma depending on the explantation technique used. Re-implantation and repeat explantation appeared to destroy most of the intracochlear architecture. CONCLUSIONS: The perimodiolar electrode array prototype with Teflon positioner cannot be recommended for clinical use, especially in children in whom the possibility for re-implantation is high.

Child↗

A new method for extracting wooden foreign bodies from the upper esophagus.

A foreign body impacted in the esophagus is an emergency case that requires immediate treatment. Often the foreign body can be removed easily using forceps or loops. Sometimes, however, safe grasping and extraction may become very difficult. A patient swallowed a chestnut which then stuck in the upper esophagus. The chestnut was removed with a gynecological instrument with a spiral tip used for myoma fixation. Thereafter this technique was applied to in vitro tests with various kinds of meat and wood. In the clinical case, the chestnut could be removed with the spiral tip of the instrument for myoma fixation, whereas in the in vitro tests it was impossible to grasp meat or cut it into pieces. The removal of foreign bodies, such as wood, with the spiral tip of the instrument for myoma fixation during rigid esophagoscopy is an alternative to extraction with forceps or loops. This method is ineffective for the removal of pieces of meat.

Esophagoscopy↗