[Aortic insufficiency from a closed chest injury treated by prosthesis].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Actis Dato.
Explore the source record for details and available documents.
From 1964 to 1979, 446 patients were treated with pace-maker implantation for a total of 730 devices. Epicardial stimulation was employed in 263 cases, endocardial in 160, and both in 23. The results, complications, treatment and indications are reported and discussed.
The results in 504 patients operated with aortic valve replacement are reported. In 153 patients other associated valvular diseases or complications were present. The mortality in non complicated case was 3%. The long term mortality (1--14 years) was 4%. The results and indications are discussed.
In 122 patients with Fallot tetralogy total correction was performed. 18 were previously operated with palliative surgery. The results were the following: hospital mortality: 8,5%; very good or good improvement: 78%; satisfactory in 13,5%.
Operation was performed in 180 patients with post-infarction ventricular aneurysm (12 cases) or akinesia (92 cases). Simultaneously in 2 cases mitral valve replacement was performed and in 2 cases ruptured ventricular septum was treated by patch. The results are reported and discussed.
Explore the source record for details and available documents.
A cold water circulation heat exchanger metal probe was used in 3 patients to treat severe hyperthermia. The probe was introduced into the caval veins by way of the sephenous vein. In 40' temperature fell from 42 degrees to 37 degrees and the patients were saved. The apparatus is simple and the technique straightforward.
22 cases of aortic valvular insufficiency treated by prosthesis and in which the acinetic areas of the left ventricle were eliminated at the same time are reported. Only one postoperative death (ventricular fibrillation) was encountered; one after 1 year (emboly as a result of endocarditis) and one as a result of an unknown cause. Emphasis is laid upon the frequency of this associated complication, its seriously negative incidence on ventricular haemodynamics, the need for surgical treatment, and its favourable immediate and long-term results.
In treating a.v. block by endocardial pacemaker, it is often necessary to remove the catheter electrode after a time. Usually this is tenaciously clamped to the endocardium. A simple modification has been made to the electrode to enable it to be removed easily, safely and completely.
Explore the source record for details and available documents.
Widening of the supravalvular aorta by means of a lozenge-shaped dacron patch was performed in 9 cases of stenosis and/or aorta insufficiency. Marked improvement was noted in the 8 patients followed up: the transvalvular gradient was not significant and neither haemolytic anaemia nor hyperhaemolysis were present. This expedient is both useful and indicated in cases where the calibre of the descending aorta is small.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.