Radiation induced failures of complementary metal oxide semiconductor containing pacemakers: a potentially lethal complication.

New multi-programmable pacemakers frequently employ complementary metal oxide semiconductors (CMOS). This circuitry appears more sensitive to the effects of ionizing radiation when compared to the semiconductor circuits used in older pacemakers. A case of radiation induced runaway pacemaker in a CMOS device is described. Because of this and other recent reports of radiation therapy-induced CMOS type pacemaker failure, these pacemakers should not be irradiated. If necessary, the pacemaker can be shielded or moved to a site which can be shielded before institution of radiation therapy. This is done to prevent damage to the CMOS circuit and the life threatening arrythmias which may result from such damage.

Aged↗

Enhanced survival of ultraviolet-irradiated herpes simplex virus in cells exposed to antiviral agents.

Enhanced survival of UV-irradiated HSV-1 is demonstrated in monkey cells exposed to inhibitors of viral DNA synthesis. Phosphonoacetic acid (PAA), adenine arabinoside (ara-A), and cytosine arabinoside (ara-C) pretreatment of infected cells is associated with concentration-dependent reactivation of UV-HSV-1. At concentrations that result in enhanced virus survival, inhibition of cell DNA synthesis is observed by either ara-A or ara-C, but not by PAA. Pretreatment of uninfected cells with acycloguanosine (ACG) is not associated with reactivation of irradiated HSV-1, and this is probably due to insufficient generation of ACG-triphosphate, the active inhibitor of viral and cell DNA synthesis.

Acyclovir↗

Mechanisms of photodynamic inactivation of herpes simplex viruses: comparison between methylene blue, light plus electricity, and hematoporhyrin plus light.

Herpes simplex virus (HSV) types 1 and 2 have been inactivated in vitro using low concentrations of methylene blue (MB), light (lambda) plus electricity (E), or hematoporphyrin derivative (HPD) plus lambda. Both techniques introduce single strand interruptions into viral DNA, but do not make double strand ruptions into viral DNA, but do not make double strand breaks. MB, lambda plus E-treated virions adsorb normally to and penetrate susceptible cells, whereas HSV inactivated with HPC and light does not. This difference is emphasized by the induction of new viral and cell DNA synthesis after infection with MB, lambda plus E-treated virions, whereas only cell, DNA but no HSV DNA, is made subsequent to HPD and lambda exposure. These observations reflect disparate mechanisms of viral inactivation. A block(s) in viral maturation, subsequent to viral DNA synthesis, occurs as a result of treatment with MB, lambda and E, whereas HPD plus lambda-treated particles fail to enter a susceptible cell, and therefore do not initiate an infection.

Cell Survival↗

Scattering effects on the dosimetry of iridium-192.

Dosimetry calculations for iridium-192 sources generally assume that a sufficient medium surrounds both the iridium source(s) and the point of calculation so that full scattering conditions exist. In several clinical applications the iridium sources may be anatomically located so that the full scattering requirement is not satisfied. To assess the magnitude of this problem, relative measurements were made with a small ionization chamber in phantoms near air and lung-equivalent interfaces. Dose reduction caused by decreasing the volume of scattering material near these interfaces was then evaluated for a few clinical applications. The results show that reductions on the order of 8% may be expected at the interface with minimal dose reduction within the volume of the implant itself. In addition, the results indicate the verification of source strength of iridium sources in phantom require phantom dimensions determined by the source-chamber separation distance.

Brachytherapy↗

Stereotactic radiosurgery: dose-volume analysis of linear accelerator techniques.

Stereotactic radiosurgery of the brain may be accomplished with a linear accelerator by performing several noncoplanar arcs of a highly collimated beam focused at a point. The shape of the radiation distribution produced by this technique is affected by the beam energy, field size, and the number and size of the arcs. The influence of these parameters on the resulting radiation distributions was analyzed by computing dose volume histograms for a typical brain. Dose volume functions were computed for: (a) the energy range of 4-24 MV x rays; (b) target sizes of 1-4 cm; and (c) 1-11 arcs and dynamic rotation. The dose volume histograms were found to be dependent on the number of arcs for target sizes of 1-4 cm. However, these differences were minimal for techniques with 4 arcs or more. The influence of beam energy on the dose volume histogram was also found to be minimal.

Brain↗

Interstitial microwave hyperthermia applicators having submillimetre diameters.

Using microscopic techniques we have fabricated interstitial hyperthermia applicators having diameters of 0.20, 0.33 and 0.58 mm, which will fit through catheters of 30, 26 and 22 gauge, respectively. Existing commercial applicators having a diameter of 1.1 mm required 17 gauge (or larger) catheters. Our new applicators, which operate at 915 MHz, are a smaller version of a design used by others. We have characterized our applicators by determining the energy deposition patterns (SAR) in muscle-simulating phantoms. These patterns were determined by measuring the electric field intensity using a miniature implantable isotropic probe having a diameter of 3 mm. Contours of the SAR data for our applicators, as well as a larger commercial applicator, show that all of these applicators exhibit similar heating patterns. Test results suggest that the durability and power handling capability of our submillimetre applicators are adequate for use in patients. Our new applicators should be useful in the percutaneous treatment of deep-seated tumours, intraoperative treatments, and also permit intraluminal or intravascular access to tumours.

Biomedical Engineering↗

Evaluation of heating patterns of microwave interstitial applicators using miniature electric field and fluoroptic temperature probes.

The SAR patterns were determined for four commercially available microwave (915 MHz) interstitial applicators. Values of SAR were determined using a miniature (3 mm diameter) implantable isotropic electric field probe or a custom 0.25 mm diameter fluoroptic temperature probe. These are the smallest such probes that are currently available. Similar radial variation of SAR was found at the axial position of the gap in the outer conductor for each applicator. Electric field probe measurements are much faster and avoid some of the errors caused by the rapid spatial variation of SAR with interstitial applicators. The major limitation on the electric field probe is its size; it is larger than the applicators being tested.

Electronics, Medical↗