Retentive characteristics of different magnetic systems for dental applications.

Six magnet-keeper systems were tested to determine the relationship between an air gap and the resulting breakaway force. The maximum retention was obtained when the magnet and keeper were in apposition. However, as the air gap increased in 0.1 mm increments, the breakaway force diminished rapidly initially and, then began to taper off at 0.2 to 0.3 mm. Ideally, the preferred placement of the magnet into the denture is with a carefully controlled system to provide an air gap. Then the magnet is attached with a minimal amount of autopolymerizing acrylic resin.

Denture Design↗

Stresses induced by endodontic stabilizers.

The force transmission of tapered, smooth-sided and parallel, threaded-sided single-crystal sapphire endodontic stabilizers was studied and the conclusions were: The stabilizer designs provided substantial fixation of the periodontically compromised model teeth and reduced tooth mobility from 3 to 0. Both stabilizer designs dramatically improved the stress distribution in the supporting structures caused by applied loads. The most distinct and highest intensity of stress concentrations were observed in the models immediately after insertion of the stabilizer. Stresses were reduced with the presence of the fibrous tissue simulation. The most favorable stress distributions were demonstrated, irrespective of configuration, in the models representing full bone-stabilizer encapsulation.

Biomechanical Phenomena↗

Effect of metal surface treatment on ceramic bond strength.

This study indicates that the unaltered specimens of both alloys produced the lowest bond values; for the gold-palladium alloy, a short degassing period (manufacturer's recommendation) and a 10-minute degassing period resulted in significantly lower bond strengths than those observed with the aluminum oxide and the steam cleaning treatments; and all treatments of the silver-palladium alloy gave comparable bond strengths to that obtained with the manufacturer's recommendation for surface treatment. Because the simplified methods gave equivalent or higher bond strength values than the manufacturer's recommendations, and because of the time saving, we recommend the following procedures for the porcelain-alloy systems tested: After casting and investment removal, use an abrasive to remove casting irregularities and to modify or correct the surface that will receive porcelain. Create a uniform matte finish on the surface that is to receive porcelain by pressure blasting with 50 micron aluminum oxide particles, or steam clean the surface for 30 seconds, or both. Proceed with opaquing.

Dental Alloys↗

Photoelastic analysis of stresses in resin-bonded cingulum rest seats.

Two-dimensional photoelastic analysis of resin-bonded cingulum rest seats demonstrated improvement in stress distribution when the lingual surface of the tooth was prepared with a cingulum groove. This preparation is more important for teeth that are more vertically or lingually oriented and have flatter lingual surfaces, such as mandibular canines.

Cuspid↗

Retentive and stress characteristics for a magnetically retained partial overdenture.

The retentive and stress characteristics of a magnetically retained partial overdenture were studied. The retentive properties were compared to those of an I-bar and Zest Anchor retained overdenture. The magnetically retained partial denture uniformly distributed stress to the supporting structures and exhibited significantly greater retention than that of the I-bar, but less than that of the Zest Anchor. Based on these observations, the magnetically retained denture should be considered as an option to be used instead of or in conjunction with other types of partial overdentures.

Dental Abutments↗

Photoelastic effects of maxillary protraction on the craniofacial complex.

The conventional treatment of anterior crossbites has been the application of orthopedic force to the mandible to redirect its growth. However, in the patient with an underdeveloped maxilla, this treatment alone is not sufficient. Therefore, the purpose of this investigation was to study the orthopedic effects of maxillary protraction appliances in the treatment of anterior crossbites. A three-dimensional anatomic model of a human skull was fabricated with birefringent materials for photoelastic analysis. Three maxillary protraction appliances that utilized different anchorage units were used. The protraction forces placed on these appliances were parallel to the occlusal plane, a downward vector 20 degrees to the occlusal plane, and a combination of these two vectors. The resulting stress patterns were observed. The effects of the forces produced by the three appliances were transmitted to the maxilla and distant craniofacial structures. Both a parallel traction and a 20 degrees downward pull to the occlusal plane caused a constriction of the anterior portion of the maxilla. The parallel traction caused a counterclockwise (opening) rotation of the molar tooth and palatal plane. A 20 degrees downward force to the occlusal plane decreased this effect.

Bicuspid↗

A photoelastic study of stress distribution by a mandibular split major connector.

This investigation evaluated the stress patterns in a photoelastic model produced by three different mandibular major connectors. The results were as follows. There were minimal differences in stress generated by the rigid and the short split frameworks. When the split extended to the midline, the stress on the distal-extension abutment was in a more vertical direction and decreased in magnitude. The stress in the edentulous portion of the distal-extension side was increased with the long split when force was applied. When force was applied to the tooth-supported side of the removable partial denture, the difference in stress among the three frameworks was insignificant. The long split major connector is a viable, inexpensive alternative to manufactured stress breakers for distal-extension removable partial dentures.

Dental Abutments↗

Distribution of stresses in the human skull.

A three-dimensional photoelastic model was reproduced from a human skull. The insertions of the superficial and deep portions of the masseter muscle, the temporalis muscle, the medial pterygoid muscle and the temporalis fascia were simulated with leather bonded to the appropriate areas. The following loading conditions were employed: (i) all three muscles were bilaterally loaded without occlusal loads; (ii) all three muscles were bilaterally loaded while occlusal loads were simultaneously applied on the maxillary teeth. The stress freezing technique was used to lock the resulting stress patterns into the model skull. The stress trajectories were observed and photographed in a circular polariscope. The mandibular closing muscles and the occlusal loads produced stresses which progressed through the maxilla, following a nasal, a zygomatic and a pterygoid route, while stress concentrations were seen in the frontonasal, zygomaticomaxillary and the pterygopalatine sutures. In the malar bone area the stresses were seen to branch superiorly to the frontozygomatic suture and posteriorly along the zygomatic arch to the zygomaticotemporal suture and the temporal bone. Generally, the stresses were concentrated in those areas of the skull where architectural reinforcement had been demonstrated by other methods.

Bite Force↗

Orthodontic force characteristics of open coil springs.

Applications of open coil springs in orthodontic tooth movement are many and varied. Current descriptions of force production by open coil springs are based upon force values produced in series of discrete compression tests. It was the purpose of this study to analyze and compare open-coil-spring force production from continuous load-deflection curves, thereby assisting the clinician in the selection of the ideal spring for a given application. Load-deflection curves were generated for open coil springs of various wire diameters and lumen sizes, as well as four wire alloys from three manufactures. Testing was performed on an Instron test machine using 0.016 inch round and 0.018 by 0.022 inch rectangular arch wires. With a constant lumen size, an increase in wire size produced an increase in force at a given activation. With a constant wire size, an increase in lumen size produced a decrease in force at a given activation. The effect of the arch wire size and shape was not significantly different for the coil springs with the smaller lumen sizes. For the larger lumen sizes, the springs used with the rectangular arch wire manifested a greater linear range than those used with the smaller arch wire. The difference between the load-deflection characteristics of the coil springs from different manufacturers was attributed to the difference in the pitch of the coils.

Equipment Design↗

A photoelastic study of a split palatal major connector.

A study was made to determine if the split palatal design of maxillary major connectors used on distal-extension removable partial dentures would result in a reduction of torquing stresses on the abutment teeth when the bases were loaded. A photoelastic model to simulate the maxillary arch, abutment teeth with their periodontal ligaments, edentulous ridges, and mucoperiosteum of the palate and ridges was constructed. Two Kennedy Class II removable partial denture frameworks of chrome-nickel alloy were constructed to fit the photoelastic model. One framework had an intact palatal major connector, and the other had a split in the major connector to separate the base from the abutment tooth as a stress-breaker. The frameworks were placed on the model, loaded, and photographed with polarized light to record the stress pattern in the model. The results of this study showed that the split palatal major connector did reduce the stress delivered to the distal-extension abutment when the base was loaded on the experimental model. A significant amount of stress from loading of the framework was removed from the abutment tooth and transferred to the regions of the model underlying the base.

Acrylic Resins↗